• 제목/요약/키워드: Insulation Diagnosis

검색결과 266건 처리시간 0.027초

GIS 절연진단 센서 설계 (A Design of Insulted Diagnosis Sensor for GIS)

  • 최은혁;김기채;이광식
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2005년도 종합학술발표회 논문집 Vol.15 No.1
    • /
    • pp.381-384
    • /
    • 2005
  • If obstacle in GIS(Gas Insulted Switchgear), its affects are great are on the community and it is consequently demanded lots of difficulties to recover and repair. Accordingly, diagnosis techniques, that are able to prevent from accidents before they happen by providing more stable and highly reliable power effectively and finding sign of the accidents is very important A novel UHF(Ultra High Frequency)-microstrip antenna is presented. The measured impedance bandwidth of the proposed antenna is from 0.5[GHz] to 15[GHz] with the stop band from 0.5[GHz] to 10.7 [GHz] for VSWR<2. Form results of this study, The antenna is will play an important role for the sensor for insulation diagnosis system by UHF method of real site GIS and power equipment using SF$_6$ gas.

  • PDF

철도차량 견인전동기의 상태진단 및 상시감시 기술 (Condition Diagnosis & On-line Monitoring Technology on the Traction Motor for Railway Rolling Stock)

  • 왕종배;변윤섭;백종현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 제2회 학술대회 논문집 일렉트렛트 및 응용기술전문연구회
    • /
    • pp.36-39
    • /
    • 2000
  • This paper presents the technology of condition diagnosis & life estimation on insulation system of the traction motor. In the non-destructive methods for diagnosis of coil insulation state, residual dielectric strength is estimated by the D-map which consist of the partial discharge quantity Q and average degradation degree $\Delta$. In the operating history of machine, the N-Y life estimation method is based on the stop-starting numbers and operating times with considering each degradation factor by the thermal, electrical and heat-cycle stress. With the on-line conditioning monitoring on the currents of traction motors, detecting the abnormal operating state due to bearing faults, stator or armature faults, eccentricity related faults and broken rotor bars can be performed.

  • PDF

배전용 CV케이블의 현장 열화진단 결과의 고찰 (A Study on the Results of the diagnosis of Insulation Deterioration in Live-Line Distribution Power Cables at the Field)

  • 유성종;전승익;정석윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1831-1834
    • /
    • 1996
  • Diagnosis of cable insulation degradation has important meaning from a viewpoint of reliability enhancement of CV cable systems. So, we diagnosed 3.3kV & 6.6kV CV distribution cable on live-line which is judged to a most poor installation condition because they have been used in water condition after installation at the Yeochon chemical complex. The paper describes the analysis of the measured data, the problems at diagnosis, and the items which are considered at the development of diagnosis technology and equipment hearafter.

  • PDF

발전기 고정자 권선 절연상태의 상시 감시 시스템 개발 (Development of Continuous Monitoring System for Generator Stator Insulations)

  • 신병철;황돈하;김용주;김정우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2212-2214
    • /
    • 1999
  • In this paper, a novel Generator On-line Diagnosis System (GODS) is proposed. This system monitors the insulation condition of the stator winding by on-line measurements of partial discharge (PD). Sensor, such as SSC (Stator Slot Coupler) and RFCT (Radio Frequency Current Transformer) are used for PD measurement. PD signals are continuously measured and digitized with a high speed A/D converter to build the database of the generator's insulation condition. Also this system can communicate with the central monitoring system via RS-485. This helps more efficient operation and maintenance of the generator.

  • PDF

견인전동기의 고장예측 및 신뢰성 평가를 위한 복합가속열화 상태진단 - 절연저항 및 성극지수 특성 연구 (Condition Diagnosis by the Complex Accelerating Degradation for fault Prediction & estimation of reliability on the traction motor - Insulation Resistance & Polarization Index Properties)

  • 왕종배;변윤섭;백종현;박현준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.1374-1376
    • /
    • 2000
  • In this paper, sample coils for stator form-wound winding of traction motor were tested by the accelerative thermal degradation, which composed of heat, vibration, moisture and overvoltage applying. Reliability and expected life were evaluated on the insulation system for 200 class traction motor. After aging of 10 cycles, insulation resistance and PI properties were investigated as diagnosis tests in the range of $20{\sim}160^{\circ}C$. Analysis of polarization properties was performed on the base of do current-time change.

  • PDF

고압회전기 절연열화진단의 현장적용기술연구 (A Study on Site Application Techniques for Insulation Reliability of Rotating Machine)

  • 김길용;조경해;김택수;한상욱;이현수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.286-291
    • /
    • 1991
  • Most of the failures of rotating machine are stator coil insulation failures. The insulation diagnostic testing for high voltage motors and generators are only megger test and P. I Test which is applied DC voltage until now. But it was impossible to judge insulation deterioration status of high voltage rotating machinery by above testing. In other words, even though the megger measurement values are fairly high, they used to be failed from time to time. Therefore in order to excute reliable and detailed diagnosis of insulation deterioration for rotating machinery, the tangent delta test, the alternating current test and the partial discharge test shall be applied to the insulation diagnostic testing on site.

  • PDF

인버터 전원에 의한 견인전동기 고정자 코일의 절연특성 변화 (Change of Insulation Properties of Stator Coil fed by Inverter Source on Traction Motor)

  • 장동욱;박현준;이길헌;최종선;김정수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.420-422
    • /
    • 2003
  • Aging and failure of motor insulation depend on the stresses imposed on it. The insulation life time depends on the severity of the stresses. The electrical aging by transient surge is very important to traction motor in EMU(electric multiple unit). This paper Presents the insulation characteristics of stator coil by transient surge from inverter. There are several nondestructive tests available for checking the condition of motor insulation, the probable extent of aging,. and the rate of which aging is taking pace. So the insulation characteristics of stator coil were each analyzed by measurement of leakage current, dielectric loss($tan{\delta}$), capacitance, polarization index(PI) and partial discharge. The method of diagnosis is able to analyze the aging condition and Predict the life of the traction motor in EMU.

  • PDF

인버터 서지에 의한 견인전동기 고정자 권선의 전기적 특성 변화 (Properties of Electrical Performance by Inverter Surge on Stator Coil of Traction Motor)

  • 박현준;장동욱;최남호;최종선;김종수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1285-1287
    • /
    • 2003
  • The aging of the insulation reduces the electrical and mechanical strength of the insulation. At same point, a voltage surge or mechanical shock from a traction motor start will fracture or break down the insulation. To achieve the expected life usually requires extensive laboratory evaluation of the insulation systems and the use of accelerated aging tests. There are several nondestructive test available for checking. the condition of motor insulation, the probable extent of aging, and the rate of which aging is taking place. So the insulation characteristics of stator coil were each analyzed by measurement of dielectric loss($tan{\delta}$), capacitance and partial discharge. The method of diagnosis is able to analyze the aging condition and predict the life of the traction motor.

  • PDF

전동기 안전진단시스템 개발에 관한 연구 (Development of Intelligent safety diagnosis system of motor)

  • 강대규;이성근
    • 한국정보통신학회논문지
    • /
    • 제5권1호
    • /
    • pp.125-132
    • /
    • 2001
  • 본 논문에서는 선박에서 사용되고 있는 전동기의 절연저항 및 전류를 검출하여 안전진단을 행하는 안전진단시스템을 제안한다. 선박용 전동기는 상시 해풍·기름 등의 오염물질에 노출되어있기 때문에 절연저항의 감소, 과전류 등의 문제점이 야기될 수 있다. 이러한 문제는 선박의 안전항해에 막대한 영향을 주어 크나큰 인명과 재산상의 손실을 초래하게 된다. 제안된 시스템은 전동기의 절연저항 및 전류를 검침하여 이를 현장에서는 물론 제어실에서 확인 관리함으로서 사고가 발생하기 전에 전통기의 이상여부를 확인 할 수 있도록 한다. 제안된 방법의 타당성을 3상 유도전동기를 대상으로 확인한다.

  • PDF

선박용 전동기 진단장치 개발에 관한 연구 (Development of diagnosis system of motor for a ship.)

  • 강대규;김종윤;이성근;김윤식
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2001년도 춘계종합학술대회
    • /
    • pp.474-478
    • /
    • 2001
  • 본 논문에서는 선박에서 제공하는 전동기의 절연저항 및 전류를 상시 검출하여 진단을 행하는 진단 시스템을 제안한다. 선박공 전동기는 상시 해풍ㆍ기름 등의 오염물질에 노출되어있기 때문에 절연저항의 감소, 과전류 등의 문제점이 야기될 수 있다. 이러한 문제는 선박의 안전항해에 막대한 영향을 주어 크나큰 인명과 재산상의 손실을 초래하게된다. 제안된 진단장치는 전동기의 절연저항 및 전류를 연속적으로 감시할 뿐만 아니라 제어실에서도 데이터를 획득찬 수 있도록 설계한다. 제안된 방법의 타당성을 3상 유도전동기를 대상으로 확인한다.

  • PDF