• 제목/요약/키워드: Insulating performance

검색결과 242건 처리시간 0.032초

고압용 XLPE의 유전특성에 관한 연구 (A Study on Dielectric Properties of XLPE for High Voltage)

  • 이용성;이경용;이관우;최용성;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1561-1563
    • /
    • 2004
  • In this paper, we researched the dielectric properties and voltage dependence on slice XLPE sheet from 22[kV] and 154[kV] power cable. We studied effects for impurities and water for semiconductor shield through a dielectric properties experiment to estimate performance of insulating materials in power cable. Capacitance and tan${\delta}$ of 22[kV], 154[kV] were 53/43[pF] and $7.4{\times}10^{-4},\;2.1510^{-4}$. In these results, the trend was increased with the increase of temperature. The tan${\delta}$ of XLPF/ semiconductor layer was increased as compared with that of XLPE. Dielectric properties reliability of tan${\delta}$ was small.

  • PDF

환경분석기반 한옥 시공 시뮬레이션에 관한 연구 (Han-ok Construction Simulation based on Environmental Analysis)

  • 김미경;전한종
    • 한국CDE학회논문집
    • /
    • 제16권4호
    • /
    • pp.292-299
    • /
    • 2011
  • Han-ok has a long history and cultural traditions. It has green and healthy and culture but high construction costs, thermal insulation performance of residential and vulnerable to fires and have a weakness for maintenance. However, modernized resident housing, Han-ok is required to improve in terms of environmental aspect due to its weakness for insulating and inconvenience for modem era. Also Han-Ok's building is criticized as a huge dependence on subjective building experiences. This is pointed to be the biggest problem, Han-ok has. Traditionally it does not have a scientific and specific manual for construction. In this research, process simulation was adopted to develop Han-Ok's environmental improvements. In terms of LCC (Life Cycle Cost) aspect, however, Han-Ok's environmental characteristics are examined to suggest an appropriate Han-Ok construction method. Also the result of this research would be utilized to base the information database for efficient constructing and its management in new Han-Ok constructing industry.

평행평판의 전극형상에 따른 ER 유체의 유동특성 I (The Flow Characteristics of ER Fluids According to the Electrode Shape of Two Parallel-Plate)

  • 장성철;염만오;김도태;김태형;배태열
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.207-212
    • /
    • 2001
  • Electro-Rheological(ER) fluid are suspensions which show an abrupt increase in rheological properties under electric fields. ER effects arise from electrostatic forces between the starch particles dispersed in the electrically insulating silicone oil, induced when an electric field is applied. Yield stress of the fluids were measured on the couette cell type rheometer as a function of electric fields. This paper presents performance analyses of four types of the two parallel-plate. Which have different electrode length and width but same electrode area. On the basis of the pressure drop and flow rate analysis. Four types of the two parallel-plate are designed and manufactured. Using ER fluid, it is possible to directly interface between electric signals and fluid power without moving parts.

  • PDF

170 kV GIS용 Composite Hollow Insulator 특성 평가 (Characteristices of Composite Hollow Insulator for 170 kV GIS)

  • 장윤기;정용수;이동원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1534-1535
    • /
    • 2011
  • Composite hollow insulator consist of an insulating tube bearing the mechanical load protected by an elastomer housing the loads being transmitted to the tube by metal fittings. The core processes are comprised briefly and the electrical and mechanical performance were examined according to the IEC standards. In this study, we have manufactured the composite hollow insulator, and carry out the insulator and busing type test according to the IEC standards. Comprehensive approach followed by the test results would give feasible hollow composite insulator compliable to the IEC standards.

  • PDF

옥외용 고분자 절연물의 표면 열화진단을 위한 아크파형 분석 (The Analysis of Arc Waveform for determing Surface Ageing of Polymeric Insulator for Out Door)

  • 문중섭;서광석;김정호;이재형;송우창;박용관
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2405-2407
    • /
    • 1999
  • In recent, the application of polymeric insulators for outdoor is significantly increasing. These materials have shown good performance in service, but had disadvantages under long-term exposure to contamination and moisture, resulting in some problems. Thus, this study concentrated on the development of technique evaluating the insulating status. Experiment was referred to lEC publ. 587, with data aquisition system to monitor leakage current. The components of leakage current investigated were waveform and 3rd harmonic. FFT was conducted for the analysis of harmonic components. The distortion of waveform with application time of voltage was evident, and so the 3rd harmonic component.

  • PDF

파이프 순환수의 수치해석 모사를 통한 수직 밀폐형 지중열교환기 단면의 열전달 효율 평가 (Numerical Evaluation of Heat Transfer un Ground Heat Exchanger Considering Flow through U-loop)

  • 길후정;이강자;이철호;최항석
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.583-587
    • /
    • 2009
  • This paper presents a series of numerical simulations on the thermal performance and sectional efficiency of a closed-loop vertical ground heat exchanger (U-loop) equipped in a geothermal heat pump system (GHP). A 3-D finite volume analysis (Fluent) was used to simulate the operating process of the closed-loop vertical ground heat exchanger by considering the effect of the thickness of HDPE pipe and grout thermal properties, distance between the inflow and outflow pipes, and the effectiveness of the latticed HDPE pipe system. It was observed that the thermal interference between the two strands of U-loop is of importance in determining the efficiency of the ground heat exchanger, and thus it is highly recommendable to modify the cross section configuration of the conventional U-loop system by including a thermally insulating latice between the two strands.

  • PDF

천장구조를 이용한 공동주택 바닥충격음 차단성능 개선에 관한 연구 (A Study on the Improvement Floor Impact Sound Insulation by Ceiling Structure in Apartment Houses)

  • 기노갑;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.1038-1042
    • /
    • 2007
  • The factors influencing the floor impact sound insulation include floor finishing materials, shock absorbing floors (slabs included), and ceiling structures. The ceilings of the apartment houses, currently built in Korea, are set up with lower parts of slabs and paper finishing, or with double floors for protecting against floor impact sounds in order to improve the sound insulating performance. The most common the method of ceiling structure construction consists of 'wood boarded frames + Gypsum boards + ceiling papers', which is called the wood boarded frame method. This study aimed to measures and evaluates floor impact sound insulation by which the ceiling space are widened according to suppression system is added in apartment house ceiling structure.

  • PDF

불평등전계에서의 건조공기/에폭시 복합절연물의 에폭시 두께에 따른 AC 파괴전압 분석 (Analysis of AC Breakdown Voltage accoding to epoxy thickness of Composite Insulation for Dry-Air/Epoxy under non-uniform electric field)

  • 허준;이승수;임기조;정해은;강성화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.113-114
    • /
    • 2008
  • The purpose of this paper is to analyze AC Breakdown of solid/air composite insulation depending on the thickness and the pressure of dry air for eco-friendly insulation. SF6 gas has been widely used in electric equipment as gas insulation because of high dielectric strength and arc extinguishing performance. However, because SF6 gas is one of the green house effect gases, alternative insulation such as SF6 mixture, extremely low temperature gas, vacuum, liquid and solid insulating are being investigated.

  • PDF

UPS용 절연재료의 부분방전 특성 (Partial discharge properties of insulating materials for UPS)

  • 이덕진
    • 한국컴퓨터산업학회논문지
    • /
    • 제4권12호
    • /
    • pp.1013-1020
    • /
    • 2003
  • 본 논문에서는 소형변압기에 적용되는 절연재료의 전기적 신뢰성을 평가하기 위하여 시간변화에 따른 방전전하량 특성을 조사하였다. 10[kV]의 교류전압을 인가한 후 $\pm$5[V]의 전압으로 변환시켜 A/D변환기를 통해 컴퓨터로 데이터를 저장하였으며 인가된 파형의 한주기 및 방전전하량 값을 64개로 분할하고 10초 동안 발생한 전하량을 위상별로 누적하였다. 이 값들을 분석한 결과, 전압인가시간이 증가함에 따라 방전발생빈도수 및 총 방전전하량은 감소하였으며 평균 방전전하량의 변화폭이 완만해짐을 알 수 있었다.

  • PDF

에폭시 수지의 전기 특성에 미치는 습도의 영향에 관한 연구 (A study on Effect of humidity on Electric Properties in Epoxy Resin)

  • 이성일;박일규
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.303-306
    • /
    • 2001
  • Composite insulating materials used in outdoor high voltage equipment are required to have high electric performance because of the miniaturization. The frequence dependence of the permittivity and the loss tangent have important information. In this paper we describe the frequency dependence of the permittivity and the loss tangent for epoxy resin filled with silica and the influence of filler shape on the dielectric properties. The increment of tan $\delta$ in the low frequency region is caused by the increment of both of the electrical conductivity and the polarization due to the shape of filler and water sbsorbed in and near the interface between the fillers and resins. Result of charge current and discharge measure, electric conduction increased according to voltage.

  • PDF