Using MZIs for Optical PSBT Transmissions: Requirements for Thermal Stabilization

  • Ducournau, Guillaume;Latry, Olivier;Ketata, Mohamed
    • ETRI Journal
    • /
    • 제28권5호
    • /
    • pp.615-620
    • /
    • 2006
  • In this paper, we discuss the quantification of Mach-Zehnder interferometer (MZI) thermal stabilization which is needed in optical phase shaped binary transmission (PSBT) links. Considering the thermo-optic and thermal expansion effects, we revisit the analytical expression for the thermal drift (GHz/$^{\circ}C$) of the MZI center frequency (denoted here by the 'MZI spectral drift'). An MZI is then used in an experimental transmission system using the optical PSBT format. We study the effect of spectral MZI drift by using a thermally stabilized interferometer and applying a frequency shift to the optical carrier. By using the thermal drift coefficient of the MZI, we find that to ensure low bit error rate fluctuations due to the MZI drift, the thermal stabilization of the device must have an accuracy of $0.5^{\circ}C$.

  • PDF

무선 전자청진 심음을 이용한 심장질환 분류 (Cardiac Disorder Classification Using Heart Sounds Acquired by a Wireless Electronic Stethoscope)

  • 곽철;이윤경;권오욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.101-102
    • /
    • 2007
  • Heart diseases are critical and should be detected as soon as possible. A stethoscope is a simple device to find cardiac disorder but requires keen experiences in heart sounds. We evaluate a cardiac disorder classifier by using heart sounds recorded by a digital wireless stethoscope developed in this work. The classifier uses hidden Markov models with circular state transition to model the heart sounds. We train the classifier using two kinds of data: One recorded by using our stethoscope and the other sampled from a clean heart sound database. In classification experiments using 165 sound clips, the classifier shows the classification accuracy of 82% in classifying 6 cardiac disorder categories.

  • PDF

컴퓨터 인터페이스를 위한 Hand Gesture 인식에 관한 연구 (A Study of Hand Gesture Recognition for Human Computer Interface)

  • 장호정;백한욱;정진현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.3041-3043
    • /
    • 2000
  • GUI(graphical user interface) has been the dominant platform for HCI(human computer interaction). The GUI-based style of interaction has made computers simpler and easier to use. However GUI will not easily support the range of interaction necessary to meet users' needs that are natural, intuitive, and adaptive. In this paper we study an approach to track a hand in an image sequence and recognize it, in each video frame for replacing the mouse as a pointing device to virtual reality. An algorithm for real time processing is proposed by estimating of the position of the hand and segmentation, considering the orientation of motion and color distribution of hand region.

  • PDF

AIN 체적탄성파 소자의 주파수 응답특성에 대한 전극재료의 영향 (Effect of electrode material under frequency response characteristics of AIN based FBAR devices)

  • 김보현;;박진석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.1865-1867
    • /
    • 2005
  • Film bulk acoustic resonator (FBAR) devices which adopt an air-gap type (metai/AlN/metal/air/substrate) configuration are fabricated by a novel process. The newly fabricated resonator doesn't employ any supporting layer below it. FBAR devices with the air-gap type are also fabricated using the conventional method. The frequency response characteristics of all the devices fabricated are measured and compared, in terms of the kinds of top and bottom electrode materials. The results show that the better device performance of FBAR devices can be achieved by employing the proposed process.

  • PDF

RC 기술의 자동화 장치 개발에 관한 연구(II) -위치 제어기의 개선- (A Study on the Automation Equipment Development of RC Technology(II) -Improvement of Position Controller-)

  • 김기준;김상진;송자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 추계학술대회 논문집 학회본부
    • /
    • pp.314-316
    • /
    • 1994
  • The operation of RC(Rod Consolidation) technology carry out highly radiation environment. It requires remote operation and automation for efficient handling and for minimizing radiation exposure to the operator. So we investigated up and down position control of shock absorber device in RC system. To verify the research experimentally, a RC system was set up and PI control method was applied. Fuzzy control method was also tested to further improve control behavior.

  • PDF

전자식 엔진냉각제어 시스템을 위한 팬 클러치 특성 분석 (Analysis of fan clutch characteristics for electronic engine cooling control system)

  • 류혜연;김현희;정성민;고영호;이경창
    • 한국산업융합학회 논문집
    • /
    • 제21권5호
    • /
    • pp.241-246
    • /
    • 2018
  • The engine cooling system is a device that keeps the temperature of the engine room at a proper level by driving the cooling fan when the engine room temperature that occurs during driving is above a certain temperature. Recently, the vehicle cooling system has been changed to electronic system. Therefore, in this paper, we will analyze the clutch operation characteristics for designing a superior electronic fan clutch. For this purpose, an electronic fan clutch was designed and a test bed for performance evaluation was constructed and analyzed.

블루투스를 이용한 거주환경 개선에 관한 연구 (A Study on Improvement of Living Environment using Bluetooth)

  • 최재호;김분도;주형열;김남호
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2015년도 추계학술대회
    • /
    • pp.545-548
    • /
    • 2015
  • 사회가 고도의 스마트 시대로 발전함에 따라, 편리하고 안전한 거주환경에 대한 수요가 증가되고 있으며 거주의 편리성, 안전성 및 안락함을 추구하는 방향으로 많은 연구가 진행되고 있다. 따라서 본 논문에서는 거주환경의 편의성과 안전성을 제공하기 위해, 블루투스 통신을 이용하여 온도, 습도, 가스 등의 다양한 센서에 의해 측정된 정보를 스마트 기기에 전송하고, 스마트 기기를 이용하여 거주지 내의 기기를 제어하는 방법을 제안하였다.

  • PDF

Generation of Water Droplet Ion Beam for ToF-SIMS Analysis

  • Myoung Choul Choi;Ji Young Baek;Aram Hong;Jae Yeong Eo;Chang Min Choi
    • Mass Spectrometry Letters
    • /
    • 제14권4호
    • /
    • pp.147-152
    • /
    • 2023
  • The increasing demand for two-dimensional imaging analysis using optical or electronic microscopic techniques has led to an increase in the use of simple one-dimensional and two-dimensional mass spectrometry imaging. Among these imaging methods, secondary-ion mass spectrometry (SIMS) has the best spatial resolution using a primary ion beam with a relatively insignificant beam diameter. Until recently, SIMS, which uses high-energy primary ion beams, has not been used to analyze molecules. However, owing to the development of cluster ion beams, it has been actively used to analyze various organic molecules from the surface. Researchers and commercial SIMS companies are developing cluster ion beams to analyze biological samples, including amino acids, peptides, and proteins. In this study, a water droplet ion beam for surface analysis was realized. Water droplets ions were generated via electrospraying in a vacuum without desolvation. The generated ions were accelerated at an energy of 10 keV and collided with the target sample, and secondary ion mass spectra were obtained for the generated ions using ToF-SIMS. Thus, the proposed water droplet ion-beam device showed potential applicability as a primary ion beam in SIMS.

EOG(Electro-oculogram) 신호를 이용한 Interface 장치 개발 (Development of Interface device with EOG Signal)

  • 김수종;유호선;김영철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.1821-1823
    • /
    • 2006
  • This paper presents a development of interface device for electro-oculogram(EOG) signal and it's application to the wireless mouse of wearable PC. The interface device is composed of five bio-electrodes for detecting oculomotor motion, several band-pass filters, instrumentation amplifier and a microprocessor. we have first analyzed impedance characteristics between skin and a bio-electrode. since the impedance highly depends on human face, it's magnitude differs from person. this interface device was applied to develop a wireless mouse for wearable PC, as a Bio Machine Interface(BMI). Where in the prompt on PC monitor is controlled by only EOG signals. this system was implemented in a Head Mount Display(HMD) unit. experimental results show the accuracy of above 90%.