Kim, Moon-Soon;Jung, Eui-Han;Jeong, Gi-Ho;Shim, Yoon-Bo
Analytical Science and Technology
/
v.5
no.1
/
pp.91-96
/
1992
A simple and cheap AC voltammeter was manufactured in our lab. This instrument consists of a DC function generator and a lock-in amplifier. We tested this instrument in some chemical systems. Our data, CV voltammogram and AC voltammogram, obtained form using a Pt working electrode in 1M $H_2SO_4$ and a reversible system of $1{\times}10^{-3}M$${Fe(CN)_6}^{3-}$ proved our system works well. The quantitative result of iodine is also obtained.
Journal of the Korea Academia-Industrial cooperation Society
/
v.9
no.5
/
pp.1130-1133
/
2008
In this paper, a mini-Electrocardiograph(ECG) system operated by a general 9V alkaline battery is designed and implemented. The manufactured ECG consists of the instrumentation amplifier stage for detecting and amplifying the heart signal, the high pass filter(HPF), the low pass filter(LPF), the differentiator cirduit, and the peak detector. The detected heart signal through three leads is displayed cleanly on the oscilloscope, which shows the good operation of our ECG. As the detected heart signal is digitalized and displayed on the small LCD unit, the convenience of easy checkup and portability of the implemented ECG can be largely improved. Therefore, whenever and wherever anyone may checkup his/her cardiac state with ease.
This paper presents a stator winding fault diagnosis technique of induction motor on the PC - based virtual instrumentation system designed using the graphical programming language LabVIEW. This method collects the 3-phase current signals using the current probe amplifier and PXI/DAQ system then the preprocessing removes the noise using LPF, after then this method transforms the stator current to Park's vector and obtains the each Park's Vector pattern and detects stator winding fault by comparing the obtained faulted pattern with the healthy pattern. This proposed LabVIEW based diagnosis system is applied to the 3 phase 1 hp induction motor and obtained the reasonable results under no load condition. The test results give us the possibility a simple and realistic on-line winding fault diagnosis system.
Journal of Institute of Control, Robotics and Systems
/
v.15
no.4
/
pp.406-412
/
2009
ECG is used on purpose to keep good health or monitor cardiac function of aged person as well as on purpose to diagnose the disease of heart patients. The ambulatory ECG monitoring system under guarantee of safety and accuracy is very efficient to prevent the progress of heart disease and sudden death. These systems can detect the temporary change of ECG that is very significant to diagnose heart disease such as myocardial ischemia, arrhyamia and cardiac infarction. In this paper, we describe the ECG signal analysis algorithm and measurement device for ECG monitoring. The authors designed a small-size portable ECG device that consisted of instrumentation amplifier, micro-controller, filter and RF module. The device measures ECG with four electrodes on the body and detects QRS complex and ST level change in realtime. Also it transmits the measured signals to the personal computer. The developed software for ECG analysis in personal computer has the function to detect the feature points and ST level changes.
Sin, Yu-Yeong;Kim, Seul-Ki;Lee, Ju-Kyoung;Lee, Suk;Lee, Kyung-Chang
Journal of the Korean Society of Manufacturing Process Engineers
/
v.14
no.5
/
pp.28-35
/
2015
This paper introduces a resistance scanning-type flexible tactile sensor for intelligent robots and presents the output characteristics of the sensor via signal processing. The sensor was produced via the lamination method using multi-walled carbon nanotubes (a conductive material), an insulator, and Tango-plus (an elastic material). Analog and digital signal processing boards were produced to analyze the output signal of the sensor. The analog signal processing board was made up of an integrator and an amplifier for signal stability, and the digital signal processing board was made up of an IIR filter for noise removal. Finally, the sensor output for the contact force was confirmed through experiments.
An improved derivative thermometric titration apparatus designed around operational amplifiers is described which is capable of monitoring the small temperature change and of computing the derivatives for accentuation of the titration end point that is difficult to locate by extrapolation methods. The instrument is constructed of four commercial operational amplifiers. A use of dummy cell provides the subtraction means for compensation of the initial temperature and random temperature fluctuations with a resultant gain in signal-to-noise ratio. The successive differentiation action of the computer has been nearly "perfect," so that the two breaks (blank or starting and end point of the titration curve can be located with the precision of 0.2% by observing two peak points on the second derivative curve. Arrangements useful in obtaining such a good derivative response that is exactly proportional to the input signal are discussed. Plots of the enthalphogram and its derivatives are presented, with the results of several titrations used to evaluate the performance of the apparatus.
This paper presents a design of 1-channel active dry electrode module for EEG from one's forehead. The IA(instrumentation amplifier) circuit inside the module is based on the configuration sown on the paper MettingVanRijn et al. We analyze the IA circuit to find out the related equation, and then compare its simulated characteristic with the result obtained from the real active dry electrode circuit. With the active dry electrode and the wet(Ag/AgCI) electrode connected to the separated analog processing module on one's forehead at the same time, their real time and FFT outputs of EEG are examined for comparison. The active dry electrode module has advantages over the wet electrode and its analog processing module: 1) The size of the analog processing circuit of the active dry electrode module is smaller than that of existing EEG analog processing module; 2) the total cost required to make the proposed analog processing circuit is much lower than that of the existing circuit, since the designed circuit needs smaller parts; 3) the electrical characteristic is comparable to the general EEG analog processing module even if the designed module has simpler circuit configuration.
A novel inductance simulation circuit employing only two dual-output voltage-differencing buffered amplifiers (DO-VDBAs) and a single capacitance (grounded) is proposed in this paper. The reported configuration is a purely resistor-less realization that provides electronically controllable realized inductance through biasing quantities of DO-VDBAs and does not rely on any constraints related to matched values of parameters. This structure exhibits excellent behavior under the influence of tracking errors in DO-VDBAs and does not exhibit instability at high frequencies. The simple and compact metal-oxide semiconductor (MOS) implementation of the DO-VDBAs (eight MOS per DO-VDBA) and adoption of grounded capacitance make the proposed circuit suitable for on-chip realization from the perspective of chip area consumption. The function of the pure grounded inductance is validated through high pass/bandpass filtering applications. To test the proposed design, simulations were performed in the PSPICE environment. Experimental validation was also conducted using the integrated circuit CA3080 and operational amplifier LF-356.
Im, Myung-Shin;Ko, Jong-Wan;Cho, Yun-Seok;Choi, Chang-Su;Jeon, Yi-Seul;Lee, In-Duk;Ibrahimov, Mansur
Journal of The Korean Astronomical Society
/
v.43
no.3
/
pp.75-93
/
2010
We present the characteristics of the Seoul National University 4k Camera (SNUCAM) and report its performance on the 1.5m telescope at the Maidanak observatory in Uzbekistan. SNUCAM is a CCD camera with a pixel scale of 0.266" in $4096{\times}4096$ format, covering $18.1'{\times}18.1'$ field of view on the 1.5m. The camera is currently equipped with Bessell UBVRI, $H{\alpha}$, SDSS ugriz, and Y-band filters, allowing us to carry out a variety of scientific programs ranging from exoplanet studies to survey of quasars at high redshift. We examine properties of SNUCAM such as the bias level and its temporal variation, the dark current, the readout noise, the gain, the linearity, the fringe patterns, the amplifier bias, and the bad pixels. From our observations, we also constructed the master fringe frames in I-, z-, and Y-band. We outline some of the current scientific programs being carried out with SNUCAM, and demonstrate that SNUCAM on the 1.5m can deliver excellent images that reach to the $5-{\sigma}$ detection limits of R~25.5 mag and z~22.7 mag in 1 hour total integration.
The polymerization shrinkage of composite resins is an important drawback although the composites have many advantages-more esthetic and conservative than metallic restoratives etc. The purposes of this research were to develop a new measurement method and to manufacture an instrument that can measure the initial dynamic volumetric shrinkage of composite resins during polymerization. The instrument was basically an electromagnetic balance that constructed with a force transducer using position sensitive photo detector(PSPD) and a negative feedback servo amplifier of proportional-derivative(PD) controller. The volumetric change of composites during polymerization was detected continuously as buoyancy change in distilled water by means of Archimedes's principle. It was converted to continuous electrical voltage signal in real time. The signal was properly conditioned and filtered and then it was stored in computer by a data acquisition(DAQ) board. By using this electronic instrument. the dynamic patterns of the polymerization shrinkage of eight commercial(Z-100, DenFil, AeliteFil, Z-250, P-60, SureFil, Synergy compact, and Tetric ceram) composite resins were measured and compared. The results were as follows. 1. From this project of developing instrument, the ability has been achieved that can acquire and process data of electrical signal transformed from various physical phenomenon by using temperature, displacement. photo. and force transducer. As a consequence, the instrumentation and measurement system used to analyze the physical characteristics of various dental materials in dental research field can be designed, manufactured and implemented in lab. 2. This instrument has some advantages. It was insensible to temperature change and could measure true dynamic volumetric shrinkage in real time without complicated process. It showed accuracy and high precision results with small standard deviation. 3. The polymerization shrinkage of composites was significantly different between brands and ranged from 2.47% to 3.89%, The order of polymerization shrinkage was as follows, in order of increasing shrinkage, SureFil, P60, Z250, Z100, Synergy compact. DenFil, Tetric ceram, and AeliteFil. 4. The polymerization shrinkage rate per unit time, dVol%/dt, showed that the instrument can provide an indirect research method for polymerization reaction kinetics.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.