• Title/Summary/Keyword: Instrument procedures

Search Result 147, Processing Time 0.025 seconds

Radiosonde Observation Using General Purpose Radio Receiving Instruments (범용 라디오 수신장비를 활용한 라디오존데 관측)

  • Hyungyu Kang;Joowan Kim;Minseong Park;Sanghyun An
    • Atmosphere
    • /
    • v.34 no.3
    • /
    • pp.325-336
    • /
    • 2024
  • Radiosonde is an important in-situ profiling instrument that measures atmospheric temperature, moisture, and wind structure from the surface to the middle stratosphere. The operational radiosonde measurements are carried out more than twice (at 0000 UTC and 1200 UTC) daily at approximately 1,300 World Meteorological Organization (WMO) stations and play a pivotal role in daily weather forecasts. It also contributes to the monitoring of atmospheric structure by providing the key physical information like temperature and pressure, forming the backbone of atmospheric (re)analyses and numerical weather forecasts. Additionally, high-resolution radiosonde profiles are used for calibration and evaluation of satellite products. Despite these advantages, radiosonde measurements are mostly limited to operational uses due to the high initial cost of ground instrument setup required for data transmission and reception. This study outlines a cost-effective (roughly one-tenth of the operational cost) method for establishing the ground station and the necessary radiosonde measurement procedures, offering guidance for individual researchers or university-level instructors.

Compositional analysis by NIRS diode array instrumentation on forage harvesters

  • Andreashaeusler, Michael Rode;Christian, Paul
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1619-1619
    • /
    • 2001
  • Ourwork aims to assess the content of dry matter, protein, cell wall parameters and water soluble carbohydrates in forages without having to handle samples, transport them to a laboratory, dry, grind and chemically analyze them. for this purpose, the concept of fresh forage analysis under field conditions by means of compact integrated NIRS InGaAs-diode array instruments on small plot harvesters is being evaluated for plant breeding trials. This work was performed with the world first commercial experimental forage plot harvester equipped with a NIRS module for the collection, compression, and scanning of forage samples (including automatic referencing and dark current measure ments). It was used for harvesting and analyzing a number of typical forage grass and forage legume plot trials. After NIRS measurements in the field each sample was again analyzed in the laboratory by means of a conventional grating spectrometer equipped with Si-and PbS-detectors. Conventional laboratory analysis of the samples was restricted to dry matter (DM) content by means of oven drying at 105. Routine chemometric procedures were then employed to assess the comparative accuracy and precision of the DM assessments in the spectral range between 950 and 1650nm by the NIRS diode array as well as by the conventional NIRS scanning instrument. The results of this study confirmed that the type of NIRS diode array instrument employed here functioned well even in rugged field operations. further refinements proved to be necessary for optimizing the automatic filling of the sample compartment to adjust for the wide variation in forage material under conditions of extremely low or high harvest yields. The error achieved in calibrating the apparatus for forages of typical DM content proved to be satisfactory (SECV < 1.0). Possibly as a consequence of higher sampling errors, its performance in atypical forages with elevated DM contents was less satisfactory. The error level obtained on the conventional grating NIR spectrometer was similar to that of the diode array instrument for both types of forage.

  • PDF

MANAGEMENT OF SEPARATED FILE IN THE ROOT CANAL (근관 내 File의 파절 시 대처 방안)

  • Kim, Hye-Jeong;Jang, Hoon-Sang;Park, Se-Hee;Cho, Kyung-Mo;Kim, Jin-Woo
    • Restorative Dentistry and Endodontics
    • /
    • v.31 no.3
    • /
    • pp.161-168
    • /
    • 2006
  • During root canal preparation procedures, the potential for instrument separation is always present. Files, a lentulo, a Gates-Glidden (GG) bur or any manufactured obstruction can be left behind in the canal Nickel-titanium (NiTi) rotary files are in common usage in these days. Despite their undeniable advantages, there is a potential risk of separation within the canals. It is very rapid, unpredictable, and creates a great deal of stress for the practitioner. When an endodontic instrument separates, the best option is to remove it. Ultrasonic instruments and microscopes have improved the success rate for removing separated instruments. But It is difficult and not always possible. Therefore prevention is the key. In this case report, several management methods of separated file in the canal are presented.

A Study on Standards for Establishing ATS Routes Defined by VOR in Korea (한국의 항공로 설계의 법적 근거에 관한 연구)

  • Yang, H.M.;Kim, B.J.
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.9 no.1
    • /
    • pp.31-44
    • /
    • 2001
  • This paper addresses legislation status of air route design standard of Korea. Korea Ministry of Construction and Transportation's Order Number 300 (March 28, 2001) prescribes that firstly, the design of air routes in Korea should be in accord with International Civil Aviation Organization(ICAO)'s recommendations published in Annex 11: Air Traffic Service and Procedures for Air Navigation Services: Aircraft Operations (ICAO Doc 8168-OPS, 1986), and secondly, United States Federal Aviation Administration(FAA)'s Terminal Instrument Procedures (FAA, 1976). An investigation on the current air route specifications of Korea reveals that they are in accord with neither ICAO's recommendations nor FAA's standards in that the width of Korea's air routes are narrower that the international recommendations and standards. As a member state of ICAO, it is imperative for Korea to follow the international standards. In that purposes, Korea should legislate and regulate the detail standard for air route design. For the legislation, FAA regulations are to be followed because FAA rules contains more detail specifications while ICAO recommendations includes allows a range of policy decisions, which may result in a confusion in practice.

  • PDF

A Study on GBAS Curved Approach Flight Test in Taean Airport (태안비행장 GBAS Curved Approach 비행시험에 관한 연구)

  • Kim, Woo-Ri-Ul;Hong, Gyo-Young
    • Journal of Advanced Navigation Technology
    • /
    • v.19 no.1
    • /
    • pp.1-6
    • /
    • 2015
  • Due to the rapid increase in air traffic worldwide, ICAO has replaced the existing navigation equipment with equipment based on satellite navigation. As a part of that work, ICAO was planning to replace conventional takeoff and landing service using ILS with GBAS. Unlike ILS, GBAS which uses precision approach service inducing aircraft to airport and satellite based augmentation system providing precise position information service surrounding airport is capable of providing a required performance by only a system, regardless of the number of systems, and has an advantage that it is possible curved approach. In this paper, fuel reduction of ILS approach procedures and GBAS curved approach procedures is estimated and determined by flight test in Taean Airport.

A Study on the Risk Assessment Criteria to be applicable for Establishing Flight Procedure Design Process (비행절차설계과정에서 적용 가능한 위험평가기준 연구)

  • Kim, Dohyun;Kim, W.Y.;Jie, M.S.
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.21 no.1
    • /
    • pp.51-56
    • /
    • 2013
  • Risk assessment should be processed when physical circumstances of airspace such as establishment of new flight procedures or reconstruction of existing airspace are planned to change and one of the alternatives for the change have to be selected. This is an effort to find the best alternative which is able to maintain at or above the acceptable risk level. ICAO and its contracting states provide specialized guidance material for 'Safety Management System' relating to handing airspace matters. These manuals include a conceptual framework for managing safety as well as some of the systemic processes and criteria used to meet the objectives of a State's safety programme. This criteria must be established in compliance with the State's laws and regulations for air safety and for the fulfillment of the State's safety goals. This study is to carry out the risk assessment criteria through literature reviews relevant to the safety management, and to propose the results of criteria to be applicable for establishing flight procedure design process.

Optimal Design of Stator of Permanent Magnet Motors Having Closed Slot For The Cogging Torque Reduction (폐슬롯 형상을 가진 영구 자석형 동기 전동기의 코깅 토크 저감을 위한 고정자 치수 최적화)

  • Chun, J.S.;Hong, S.K.;Yoon, J.S.;Jung, H.K.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07a
    • /
    • pp.59-61
    • /
    • 1995
  • This paper presents the cogging torque analysis of the permanent magnet type AC servo motor which have the closed slot structure. Generally, existence of the slot opening causes the cogging torque. But the cogging torque exists in this type motor(having closed slot structure) because the bridge part is saturated by the rotor flux. In this paper, the finite element analysis is used to calculate the cogging torque and the rated torque. As the size of the bridge part-the thickness and the width-changes, the cogging torque and the rated torque are obtained repeatedly like as upper procedures. Finally, the trends of the cogging torque and the rated torque versus the size of the bridge part are obtained from this analysis procedures. By this approach, the optimal geometry of the bridge part can be found which minimize the cogging torque satisfying the required value of the rated torque.

  • PDF

Endoscopic Spinal Surgery for Herniated Lumbar Discs

  • Shim, Young-Bo;Lee, Nok-Young;Huh, Seung-Ho;Ha, Sang-Soo;Yoon, Kang-Joan
    • Journal of Korean Neurosurgical Society
    • /
    • v.41 no.4
    • /
    • pp.241-245
    • /
    • 2007
  • Objective : So called "minimally invasive procedures" have evolved from chemonucleolysis, automated percutaneous discectomy, arthroscopic microdiscectomy that are mainly working within the confines of intradiscal space to transforaminal endoscopic technique to remove herniated epidural disc materials directly. The purpose of this study is to assess the result of endoscopic spinal surgery and favorable indication in the thoracolumbar spine. Methods : The records of 71 patients, 73 endoscopic procedures, were retrospectively analysed. Yeung Endoscopic Spine Surgery system with 7 mm working sleeve and $25^{\circ}$ viewing angle was used. The mean follow up period was 6 months [range, 3-9]. Results : Operated levels were from T12-L1 disc down to L5-L6 of S1 disc. Of 71 cases, 2 patients underwent transforaminal endoscopic surgery twice due to recurrence after initial operation. MacNab's criteria was used to assess the outcome. Favorable outcome, excellent of good, was seen in 78% [57 procedures] of the patients. Among 11 fair outcomes, only 1 procedure was followed by secondary open procedure, laminectomy with discectomy. Two of 5 poor outcomes were operated again by same procedure which resulted in fair outcomes. One patient with aggravated cauda equina syndrome remained poor and a lumbar fusion procedure was performed in other patient with poor outcome. There were 2 postoperative discitis that were treated with conservative care in one and anterior lumbar interbody fusion in the other. Conclusion : Evolving technology of mechanical, visual instrument enables minimal invasive procedure possible and effective. The transforaminal endoscopic spinal surgery can reach as high as T12-L1 disc level. The rate of favorable outcome is mid-range among reported endoscopic lumbar surgery series. Authors believe that the outcome will be better as cases accumulate and will be able to reach the fate of standard open microsurgery.

The complexity of opt-in procedures in mobile shopping: Moderating effects of visual attention using the eyetracker (모바일 쇼핑에서 옵트인의 절차적 복잡성 연구: 아이트래커(eyetracker) 기반 시각적 주의의 조절효과)

  • Kim, Sang-Hu;Kim, Yerang;Yang, Byunghwa
    • Journal of Digital Convergence
    • /
    • v.15 no.8
    • /
    • pp.127-135
    • /
    • 2017
  • Consumers tend to feel concern about disclosure of personal information and, at the same time, to avoid inconvenience of procedural complexity caused by the privacy protections. The purpose of current paper is to investigate relationships between opt-in procedural complexity and shopping behavior using smart phones, moderating by the amount of visual attentions using eyetrackers. Therefore, we created a virtual mobile Web-site in which the complexity of opt-in procedures in our experiment is manipulated and measured. Also, we measured the dwell-time of area of interest using SMI-RED 250 instrument for tracking the real eye movement. Results indicated that the levels of procedural complexity are related to repurchase, indicating a moderating effect of the amount of visual attentions. Finally, we discussed several theoretical and practical implications of management for mobile commerce.

The Standard Processing of a Time Series of Imaging Spectral Data Taken by the Fast Imaging Solar Spectrograph on the Goode Solar Telescope

  • Chae, Jongchul;Kang, Juhyeong;Cho, Kyuhyoun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.2
    • /
    • pp.46.1-46.1
    • /
    • 2018
  • The Fast Imaging Solar Spectrograph (FISS) on the Goode Solar Telescope (GST) at Big Bear Solar Observatory is the imaging Echelle spectrograph developed by the Solar Astronomy Group of Seoul National University and the Solar and Space Weather Group of Korea Astronomy and Space Science Institute. The instrument takes spectral data from a region on the Sun in two spectral bands simultaneously. The imaging is done by the organization of intensity data obtained from the fast raster scan of the slit over the field of view. Since the scan repeats many times, the whole set of data can be used to construct the movies of monochromatic intensity at arbitrary wavelengths within the spectral bands, and those of line-of-sight velocity inferred from different spectral lines. So far there are two standard observing configurations: one recording the $H{\alpha}$ line and the Ca II 8542 line simultaneously, and the other recording the Na I D2 line and Fe I 5435 line simultaneously. We have developed the procedures to produce the standard data for each observing configuration. The procedures include the spatial alignment, the correction of spectral shift of instrumental origin, and the lambdameter measurement of the line wavelength. The standard data include the movie of continuum intensity, the movies of intensity and velocity inferred from a chromospheric spectral line, the movies of intensity and velocity inferred from a photospheric line. The processed standard data will be freely available online (fiss.snu.ac.kr) to be used for research and public outreach. Moreover, the IDL procedures will be provided on request as well so that each researcher can adapt the programs for their own research.

  • PDF