• Title/Summary/Keyword: Instrument Error

Search Result 277, Processing Time 0.024 seconds

A Study on Engine Health Monitoring using Linear Gas Path Analysis for Turboprop Engine (선형 GPA 기법을 이용한 터보프롭 엔진의 성능진단에 관한 연구)

  • 공창덕;신현기;기자영
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.3 no.4
    • /
    • pp.93-103
    • /
    • 1999
  • The steady-state performance analysis program for turboprop engine which was used for a small, middle industrial aircraft and a basic trainer aircraft was developed and linear Gas Path Analysis method was applied to Engine Health Monitoring for Turboprop engine. This program was compared with TURBOMARCH program which is well known with performance and power according to flight Mach No. at the standard atmospheric condition to prove a steady-state performance analysis program. From the result, inlet, exit temperature and pressure of each component had error within 3% and especially power according to flight Mach No. had error within 2.4% so that this program could be assured. To make sure if linear Gas Path Analysis is reasonable four cases were selected. The first is the case that fouling is occurred in compressor only. The second is the case that fouling is occurred in compressor and erosion is occurred in turbine. The third is the case that erosion is occurred in both compressor and turbine and power turbine at the same time. Finally, the case that fouling and erosion are occurred in compressor, compressor turbine and power turbine was selected. Different parameters were selected impartially among the independent parameters so that the effect of measurement parameter selection was observed. From the result, the more measurement parameters the smaller RMS error and even though the number of measurement parameters was the same, the RMS error was obtained differently according to which measurement parameters were selected. The case using eight instrument parameters of case IV-4 had small error comparably and was economic and it was important to select optimal number of measurement and optimal measurement parameters.

  • PDF

Comparison of Wind Vectors Derived from GK2A with Aeolus/ALADIN (위성기반 GK2A의 대기운동벡터와 Aeolus/ALADIN 바람 비교)

  • Shin, Hyemin;Ahn, Myoung-Hwan;KIM, Jisoo;Lee, Sihye;Lee, Byung-Il
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.6_1
    • /
    • pp.1631-1645
    • /
    • 2021
  • This research aims to provide the characteristics of the world's first active lidar sensor Atmospheric Laser Doppler Instrument (ALADIN) wind data and Geostationary Korea Multi Purpose Satellite 2A (GK2A) Atmospheric Motion Vector (AMV) data by comparing two wind data. As a result of comparing the data from September 2019 to August 1, 2020, The total number of collocated data for the AMV (using IR channel) and Mie channel ALADIN data is 177,681 which gives the Root Mean Square Error (RMSE) of 3.73 m/s and the correlation coefficient is 0.98. For a more detailed analysis, Comparison result considering altitude and latitude, the Normalized Root Mean Squared Error (NRMSE) is 0.2-0.3 at most latitude bands. However, the upper and middle layers in the lower latitudes and the lower layer in the southern hemispheric are larger than 0.4 at specific latitudes. These results are the same for the water vapor channel and the visible channel regardless of the season, and the channel-specific and seasonal characteristics do not appear prominently. Furthermore, as a result of analyzing the distribution of clouds in the latitude band with a large difference between the two wind data, Cirrus or cumulus clouds, which can lower the accuracy of height assignment of AMV, are distributed more than at other latitude bands. Accordingly, it is suggested that ALADIN wind data in the southern hemisphere and low latitude band, where the error of the AMV is large, can have a positive effect on the numerical forecast model.

A study on the Analysis Method of Interference using SEAMCAT in UHF band (UHF대역에서의 SEAMCAT을 이용한 간섭 분석기법에 관한 연구)

  • Cho, Seung-Il;Jang, Kyoung-Seung;Kang, Sung-Chul;Lee, Joo-Hwan;Kang, Jeong-Jin;Choi, Gyoo-Seok;Cha, Jae-Sang;Kim, Seong-Kweon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.8 no.6
    • /
    • pp.119-125
    • /
    • 2008
  • In this paper, we proposed the modeling of UHF frequency environment in a random mountainous area with line of sight. A transmitting station is defined as wanted transmitter(Wr) and a receiving station is defined as victim receiver(Vr). These set up victim link. A interference transmitter(It) and wanted receiver(Wr) set up interference link. We compared measured data at random mountainous area with data of the result using spectrum engineering advanced monte calo analysis tool(SEAMCAT), interference simulation based on the monte-carlo method. The desired received signal strength(dRSS) of SEAMCAT had the calculated error of 70% from the measured received signal strength because there was a topographical effect. Therefore, the effect of diffraction interference was included to lessen the power of transmitter in the proposed simulation. The cause of received power error are cable loss and errors of a measuring instrument. The proposed simulation modeling in UHF frequency environment expect that is the useful study on interference analysis and reassignment of broadcasting frequency.

  • PDF

Quantitative analysis of the errors associated with orbit uncertainty for FORMOSAT-3

  • Wu Bor-Han;Fu Ching-Lung;Liou Yuei-An;Chen Way-Jin;Pan Hsu-Pin
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.87-90
    • /
    • 2005
  • The FORMOSAT-3/COSMIC mission is a micro satellite mission to deploy a constellation of six micro satellites at low Earth orbits. The final mission orbit is of an altitude of 750-800 lan. It is a collaborative Taiwan-USA science experiment. Each satellite consists of three science payloads in which the GPS occultation experiment (GOX) payload will collect the GPS signals for the studies of meteorology, climate, space weather, and geodesy. The GOX onboard FORMOSAT -3 is designed as a GPS receiver with 4 antennas. The fore and aft limb antennas are installed on the front and back sides, respectively, and as well as the two precise orbit determination (POD) antennas. The precise orbit information is needed for both the occultation inversion and geodetic research. However, the instrument associated errors, such as the antenna phase center offset and even the different cable delay due to the geometric configuration of fore- and aft-positions of the POD antennas produce error on the orbit. Thus, the focus of this study is to investigate the impact of POD antenna parameter on the determination of precise satellite orbit. Furthermore, the effect of the accuracy of the determined satellite orbit on the retrieved atmospheric and ionospheric parameters is also examined. The CHAMP data, the FORMOSAT-3 satellite and orbit parameters, the Bernese 5.0 software, and the occultation data processing system are used in this work. The results show that 8 cm error on the POD antenna phase center can result in ~8 cm bias on the determined orbit and subsequently cause 0.2 K deviation on the retrieved atmospheric temperature at altitudes above 10 lan.

  • PDF

Implementation of Precise Level Measurement Device using Zoom FFT (Zoom FFT를 이용한 정밀 레벨 측정 장치의 구현)

  • Ji, Suk-Joon;Lee, John-Tark
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.504-511
    • /
    • 2012
  • In this paper, level instrument is implemented using beat frequency for distance measurement which means the difference between Tx and Rx signal frequency from FMCW Radar Level Transmitter. Beat frequency is analyzed through Fast Fourier Transform of which frequency precision can be improved by applying Zoom FFT. Distance precision is improved from 146.5[mm] to 5[mm] using the advantage of Zoom FFT which can raise the frequency precision without changing the sampling frequency or FFT point number to be fixed in the beginning of designing signal processing. Also, measurement error can be reduced within 2[mm] by incresing the FFT points using the method of Spline interpolation. For verifying the effectiveness of this Zoom FFT to FMCW Radar Level Transmitter, test bench is made to measure the distance for every 1[mm] between 700[mm] and 2000[mm] and measurement error can be checked in the range of ${\pm}2$[mm].

Analysis of Intrarater and Interrater Reliability of Trunk Repositioning Error Test using a Portable Digital Inclinometer (디지털경사계를 사용한 체간재위치오류 검사의 신뢰도 분석)

  • Chang, Woo-Nam;Lee, Kyoung-Bo;Yeom, Jun-Woo;Hwang, Byong-Yong
    • The Journal of Korean Physical Therapy
    • /
    • v.25 no.4
    • /
    • pp.210-216
    • /
    • 2013
  • Purpose: A cost effective tool for the clinical measurement of trunk reposition sense is clearly needed. This study was to analyze intrarater and interrater Reliability of trunk repositioning error (TRE) test which assesses trunk position sense using a portable digital inclinometer. Methods: Twenty four normal healthy subjects were recruited. TRE was measured using a portable digital inclinometer. A digital inclinometer (Acumar-ACU360; Lafayetter Instrument) with precision to $1^{\circ}$ was placed on skin over the spinous process from first to second thoracic vertebra (T1-T2) and secured with double-sided tape. TRE test during sitting forward and lateral flexion movement was assessed. When they reached a point approximately 50% of full trunk flexion range, the examiner instructed the subjects to stop and told them. This was the target position that they should try to reproduce exactly. Each subject performed six trials. Results: ICC (2,1) for intrarater reliability (with-day and between-day) of TRE test in sagittal and frontal plane of movement was 0.75 and 0.78 (excellent reliability). Interrater reliability was 0.66 in sagittal and 0.64, frontal plane (fair to good reliability). However, there were poor correlations between an average of TRE test in sagittal and frontal plane. Conclusion: TRE test using a portable digital inclinometer demonstrated good to excellent reliability. The device may be a cost effective clinical measurement for trunk reposition sense measurement.

Clinical Comparison Of Manual Probe With Florida Probe In Adult Periodontitis (성인형 치주염 환자에 있어 manual probe의 Florida probe의 임상적 비교)

  • Yu, Hyang-Mi;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.1
    • /
    • pp.244-254
    • /
    • 1996
  • The periodontal probe is a commonly used instrument to assess periodontal conditions. And so, there has been many studies to develop the accuracy and reproducibility of the periodontal probe. The purpose of this study was to compare two different periodontal probes for measurement reliability and time required to use in subjects with moderate periodontitis. It was done after evaluating reproducibility of probing depth by stent guiding for a Manual probe and a Florida probe in subjects with healthy periodontal condition. The results were as follows 1. In experiment to evaluate the reproducibility of probing depth by stent guiding for a Manual probe and Florida probe in subjects with healthy periodontal condition, there was no major significant difference between intraprobe and interprobe relationships. 2. There were reduced probing measuremint error by using the Florida probe for posterior teeth and by using the Manual probe for anterior teeth of subjects with moderate periodontitis. 3. At proximal area, there was higher measurement error by using the Manual probe than the Florida probe. 4. The mean of pocket depth measurement using Manual probe was signifi cantly higher than that using Florida probe(p<0.05). With increasing pocket depth, interprobe difference increased and reproducibility reduced. 5. There was no significant difference in time required to use between Manual probe and Florida probe(p<0.05). 6. There was slight probing measurement difference between Manual probe and Florida probe at different site, but both probes have similar degrees of reproducibility and similar time required to probe.

  • PDF

A Status Report on Dual Energy X-ray Absorptiometry Quality Control in Korea (이중에너지 방사선흡수 골밀도 장치의 품질관리 현황)

  • Kim, Jung-Su;Rho, Young-Hoon;Lee, In-Ju;Kim, Sung-Su;Kim, Kyoung-Ah;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.527-534
    • /
    • 2016
  • Dual-energy X-ray absorptiometry (DEXA) is the most widely used technical instrument for evaluating bone mineral content (BMC) and density (BMD) in patients of all ages. In 2016, DEXA devices operating is 5617 in Korea. In this study we investigated the quality of management practices survey for DEXA equipment and we analyzed it. We got a survey response rate of 12.6%. Accurate bone densitometry test is used data for estimation a patient's risk of fracture. However, improper bone densitometry will increase the possibility of causing a false positive. Therefore. it is essential to use the proper aids accurate bone densitomenty to be performed, and the quality control of the device to reduce the error factor of the tester through the training to reduce error for the device and the attitude.

Validity and Reliability of Korean Version of the Revised Stress Appraisal Measure (RSAM) (한국어판 수정된 스트레스 평가 도구(Revised Stress Appraisal Measure)의 타당도와 신뢰도)

  • Kim, Jeong Sun;Kim, Kye-Ha;Kang, Hyuncheol
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.3
    • /
    • pp.290-302
    • /
    • 2015
  • The study purpose was to test the validity and reliability of the Korean version of the Revised Stress Appraisal Measure (RSAM) to assess stress appraisal in undergraduate students. Internal consistency reliability, construct and criterion validity were calculated using IBM SPSS Statistics 21 and AMOS 21 program. Survey data were collected from a convenience sample of 296 undergraduate students enrolled in five universities in G city and C area, South Korea. The Korean version of RSAM categorized into 5 factors explaining 68.4% of the total variance. The model of five subscales was validated by confirmatory factor analysis (p<.001, Goodness of Fit Index, Adjusted Goodness of Fit Index, Normed Fit Index, Comparative Fit Index >.08, Root Mean Square Error of Approximation=.056). In criterion validity, the scores for the scale were significantly correlated with the Perceived Stress Scale-Korean. Cronbach's alpha coefficient for the 19 items was .73~.89. The Korean RSAM showed satisfactory construct and criterion validity and reliability. Thus it may be an appropriate instrument for measuring stress appraisal in Korean university students.

REQUIREMENTS AND FEASIBILITY STUDY OF FPC-G FINE GUIDING IN SPACE INFRARED TELESCOPE, SPICA (대형 적외선 우주망원경 SPICA/FPC-G의 정밀 별추적 요구사항과 타당성 연구)

  • Jeong, Woong-Seob;Lee, Dae-Hee;Pyo, Jeonghyun;Moon, Bongkon;Park, Sung-Joon;Ree, Chang Hee;Park, Youngsik;Han, Wonyong;Nam, Ukwon;Matsumoto, Toshio
    • Publications of The Korean Astronomical Society
    • /
    • v.27 no.5
    • /
    • pp.391-397
    • /
    • 2012
  • The SPICA (SPace Infrared Telescope for Cosmology & Astrophysics) project is a next-generation infrared space telescope optimized for mid- and far-infrared observation with a cryogenically cooled 3m-class telescope. It will achieve the high resolution as well as the unprecedented sensitivity from mid to far-infrared range. The FPC (Focal Plane Camera) proposed by KASI as an international collaboration is a near-infrared instrument. The FPC-S and FPC-G are responsible for the scientific observation in the near-infrared and the fine guiding, respectively. The FPC-G will significantly reduce pointing error down to below 0.075 arcsec through the observation of guiding stars in the focal plane. We analyzed the pointing requirement from the focal plane instruments as well as the error factors affecting the pointing stability. We also obtained the expected performance in operation modes. We concluded that the FPC-G can achieve the pointing stability below 0.075 arcsec which is the requirement from the focal plane instruments.