• 제목/요약/키워드: Instrument Accuracy

Search Result 335, Processing Time 0.031 seconds

An Analysis of Performance Error of Roundness Measuring Instrument -by phase different method- (眞圓度 測定器의 誤差特性에 대한 解析 -위상차법-)

  • 한응교;허문석;박익근
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.10 no.3
    • /
    • pp.31-37
    • /
    • 1988
  • A phase different method to evaluate the instrument error of roundness measuring instrument and the form error of specimens for the calibration of the instrument is used. An instrument with a rotary table supported by an air bearing was calibrated by using the standard balls as a standard. The calibration was carried out repeatedly by setting the same ball in 12 phase angles(per 30.deg.) on the table and by recording their roundness errors with a magnification of 100,000 times. As a result of data analysis of all the observations, readout at each of 144 orientations(per 2.5.deg.) from recorded data file, the error of performance of the instrument and the specimens are separated. In the particular instrument used in the present experiment, the error of the instrument was determined with the accuracy of 0.0164 (.mu.m) and the form error of the specimens was determined with the accuracy of 0.0264,0.0172(.mu.m), respectively. If the instrument was calibrated by using the above specimens, then the accuracy of the measurement of roundness error can be improved to about 0.017 (.mu.m).

  • PDF

A Study on the Development of Hourly Evaporation Recording Instrument for Class A Pan (대형증발계용 매시간 증발 기록계 개발에 관한 연구)

  • Bu-Yong Lee
    • Journal of Environmental Science International
    • /
    • v.10 no.5
    • /
    • pp.323-327
    • /
    • 2001
  • A new method is developed to estimate the evaporation of water from a surface with high accuracy and resolution. The principle of new method is to detect a weight change of buoyant weight according to a change in water level of Class A Pan mesured by the use of a strain-gauge load cell. Field test of evaporation recording new instrument was carried out at Suwon for 10 days July 1999. It is possible in field observation to measure hourly evaporation amount by newly developed evaporation recording instrument in Class A Pan against strong solar radiation. Present study provide a possibility of domestic high accuracy instrument development below than 0.1mm water level measurement accuracy. If there is low humidity and high wind speed conditions which is possible to evaporate from water surface during night time. And it needs continuous study to understand between meteorological elements and latent heat effect at ground level by field observation study using high accuracy evaporation recording instrument.

  • PDF

An Analysis of Performance Error of High Precision Measuring Instrument (진원도 측정기의 오차특성에 관한 연구)

  • 한응교;노병옥;허민석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.5
    • /
    • pp.862-874
    • /
    • 1989
  • A phase evil method and spectrum analysis were instrument error which is originated from measurement system and the form error of standard specimens. An instrument with a rotating table supported by an air bearing is calibrated using standard specimens. The phase of standard specimens was measured 12 times on the rotating table with rotating 30 in turn and its measurement magnification was set by 100000 times. As a result of data analysis of all the observations, read out at each of 144 orientations(per 2.5) from recorded datafiles, the error of the performance of the instrument and those of the standard specimens are evaluated and a systematic deviation of the instrument is determined. In the particular instrument used in the present experiment, the deviation of the instrument is determined with the accuracy of 15nm and those of standard specimens with the accuracy of 23, 13 n, respectively. The reproducibility of the instrument is investigated, too. If the instrument is calibrated by using the above standard specimens, then the accuracy of the measurement of roundness error can be improved to about 15nm.

Development of Rain Gauge and Observation Error (우량계 개발과 측정 오차)

  • 김대원;이부용
    • Journal of Environmental Science International
    • /
    • v.11 no.10
    • /
    • pp.1055-1060
    • /
    • 2002
  • A new method of automatic recording raingauge is developed to measure rainfall 1200mm full scale with high accuracy and resolution. The principle of new instrument is to detect a weight change of a buoyant weight according to a change in water level of raingauge measured by the use of a strain gauge load cell. This method has the advantage of increasing measurement accuracy, since no moving equipment is used. Laboratory test of the instrument was recorded 0.4% error of 190mm rainfall amount. The validity of new instrument was examined by comparing its measured values with values recorded by automatic weather station on June 24 to 25 2001 at Daegu Meteorological Station, when there is 148.3mm rainfall amount. In spite of much rainfall there is only 0.77mm difference of total rainfall amount. This instrument was accomplished high accuracy and resolution at field test in much rainy day.

Constrained High Accuracy Stereo Reconstruction Method for Surgical Instruments Positioning

  • Wang, Chenhao;Shen, Yi;Zhang, Wenbin;Liu, Yuncai
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.6 no.10
    • /
    • pp.2679-2691
    • /
    • 2012
  • In this paper, a high accuracy stereo reconstruction method for surgery instruments positioning is proposed. Usually, the problem of surgical instruments reconstruction is considered as a basic task in computer vision to estimate the 3-D position of each marker on a surgery instrument from three pairs of image points. However, the existing methods considered the 3-D reconstruction of the points separately thus ignore the structure information. Meanwhile, the errors from light variation, imaging noise and quantization still affect the reconstruction accuracy. This paper proposes a method which takes the structure information of surgical instruments as constraints, and reconstructs the whole markers on one surgical instrument together. Firstly, we calibrate the instruments before navigation to get the structure parameters. The structure parameters consist of markers' number, distances between each markers and a linearity sign of each instrument. Then, the structure constraints are added to stereo reconstruction. Finally, weighted filter is used to reduce the jitter. Experiments conducted on surgery navigation system showed that our method not only improve accuracy effectively but also reduce the jitter of surgical instrument greatly.

A Transverse Load Sensor with Reconfigurable Measurement Accuracy Based on a Microwave Photonic Filter

  • Chen, Han;Li, Changqing;Min, Jing
    • Current Optics and Photonics
    • /
    • v.2 no.6
    • /
    • pp.519-524
    • /
    • 2018
  • We propose a transverse load sensor with reconfigurable measurement accuracy based on a microwave photonic filter in the $K_u$ band, incorporating a polarization-maintaining fiber Bragg grating. A prototype sensor with a reconfigurable measurement accuracy tuning range from 6.09 to 9.56 GHz/(N/mm), and corresponding minimal detectable load range from 0.0167 to 0.0263 N/mm, is experimentally demonstrated. The results illustrate that up to 40% manufacturing error in the grating length can be dynamically calibrated to the same corresponding measurement accuracy for the proposed transverse load sensor, by controlling the semiconductor optical amplifier's injection current in the range of 154 to 419 mA.

Diagnosis Accuracy Rate Comparative Study of Each Sasang Constitutions and Sex Distinction by Body Measurement Method between 3D Body Measuring Instrument and Hand-operating (3D체형측정기와 수동측정 방법간의 사상체질별 ${\cdot}$ 성별 진단정확률 비교연구)

  • Kwon, Suk-Dong;Sul, Yu-Kyung;Lee, Eui-Ju;Kim, Kyu-Kon;Kim, Jong-Won
    • Journal of Sasang Constitutional Medicine
    • /
    • v.19 no.1
    • /
    • pp.60-77
    • /
    • 2007
  • 1. Objectives This is the comparative study with hand-operated measurement method and Automatic measurement method, in order to convert the automatic measurement method. 2. Methods We measured the body of patients(hand-operated Width 5 Places and hand-operated circumference 8 place,Automatic Width 5 and automatic circumference 8 place by 3D body measuring instrument) and analyzed the anthropometric data divding into sex&age. 362 patient's data are used in the analysis. 3. Results and Conclusions 1) 1th circumference variable which standing was not a sasang constitutional difference. 2) Diagnostic accuracy rate of the body measurement was 50-80%. 3) Diagnostic accuracy rate of man is higher than Diagnostic accuracy rate of women 4) Diagnostic accuracy rate of Automatic & hand-operated measuring was not a big difference.

  • PDF

The study of Instrument Panel object cognition time and accuracy between subject groups (피험자 집단간 Instrument Panel 객체 인지시간 및 정확도에 관한 연구)

  • Yu, Seung-Dong;Park, Peom
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.22 no.52
    • /
    • pp.33-41
    • /
    • 1999
  • More than 90 percent of traffic accidents were caused by human errors in driving situation. However, the ergonomic studies were not enough to prevent these human errors. Especially, drivers acquire more than 70 percent of information using the vision, and this shows the importance of consideration about the driver's visual cognition characteristics. Consequently, the driver's cognition time and the cognition accuracy were measured for the Instrument Panel(IP) of vehicle cockpit in this study. For the experiment, subjects were divided in two groups. The first group of subjects had their own vehicles and the driver license, and the second group of the subjects didn't have own vehicle but had the driver license. IP Images were used in the experiment and the each image was made by changing layout of objects within devices. The results showed that there were no differences for the cognition time and the accuracy between images within the group, and the results between the groups showed the same trend.

  • PDF

POLYGONIOSCOPE a new instrument for fastest luminance, color and viewing angle measurement with highest accuracy

  • Laur, Juergen
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1370-1373
    • /
    • 2008
  • This paper introduces a novel display measuring instrument that allows accurate, spectro-radiometric measurement of the complete viewing cone while the measuring time is similar to that of a CCD camera with transform lens optics. Actually the new instrument, named POLYGONIOSCOPE, is orders of magnitude faster compared to a conventional spot spectrometer.

  • PDF

Machine Vision Instrument to Measure Spray Droplet Sizes (기계시각을 이용한 분무입자크기 측정)

  • Jeon, Hong-Young;Tian, Lei
    • Journal of Biosystems Engineering
    • /
    • v.35 no.6
    • /
    • pp.443-449
    • /
    • 2010
  • A machine vision-based instrument to measure a droplet size spectrum of a spray nozzle was developed and tested to evaluate its accuracy on measuring spray droplet sizes and classifying nozzle sizes. The instrument consisted of a machine vision, light emitting diode (LED) illumination and a desktop computer. The illumination and machine vision were controlled by the computer through a C++ program. The program controlled the machine vision to capture droplet images under controlled illumination, and processed the droplet images to characterize the droplet size distribution of a spray nozzle. An image processing algorithm was developed to improve the accuracy of the system by eliminating random noise and out-of-focus droplets in droplet images while measuring droplet sizes. The instrument measured sizes of the three different balls (254.0, 497.8 and $793.8\;{\mu}m$) and the measurement ranges were $241.2-273.6\;{\mu}m$, $492.9-529.6\;{\mu}m$ and $800.8-824.1\;{\mu}m$ for 254.0-, 497.84- and $793.75-\;{\mu}m$ balls, respectively. Error of the measured droplet mean was less than 3.0 %. Droplet statistics, $D_{V0.1}$, $D_{V0.5}$ and $D_{V0.9}$, of a reference nozzle set were measured, and droplet size spectra of five spray nozzles covering from very fine to extremely coarse were measured to classify spray nozzle sizes. Ninety percent of the classification results of the instrument agreed with manufacturer's classification. A comparison study was carried out between developed and commercial instruments, and measurement results of the developed instrument were within 20 % of commercial instrument results.