• Title/Summary/Keyword: Instantaneous center

Search Result 163, Processing Time 0.029 seconds

Comparison of Two Reactive Power Definitions in DFIG Wind Power System under Grid Unbalanced Condition

  • Ha, Daesu;Suh, Yongsug
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.213-214
    • /
    • 2014
  • This paper compares two instantaneous reactive power definitions in DFIG wind turbine with a back-to-back three-level neutral-point clamped voltage source converter under unbalanced grid conditions. In general, conventional definition of instantaneous reactive power is obtained by taking an imaginary component of complex power. The other definition of instantaneous reactive power can be developed based on a set of voltages lagging the grid input voltages by 90 degree. A complex quantity referred as a quadrature complex power is defined. Proposed definition of instantaneous reactive power is derived by taking a real component of quadrature complex power. The characteristics of two instantaneous reactive power definitions are compared using the ripple-free stator active power control algorithm in DFIG. Instantaneous reactive power definition based on quadrature complex power has a simpler current reference calculation control block. Ripple of instantaneous active and reactive power has the same magnitude unlike in conventional definition under grid unbalance. Comparison results of two instantaneous reactive power definitions are verified through simulation.

  • PDF

A Study on the Behavior of Welded Connections (용접 연결부의 거동에 관한 연구)

  • 안주옥;윤영만
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1994.10a
    • /
    • pp.145-151
    • /
    • 1994
  • Welded connections have been designed on basis of allowable stresses, wherein the response to loading is assumed to be totally elastic. This is the vector analysis method, which resolves the stresses determined from the direct stress formula and the torsion formula into a vector combination to obtain a solution. It has been known that this method gives conservative answers and typically a very high factor of safety. An analytical method based on the Instantaneous Center of Rotation has been developed which predicts the ultimate strength of an eccentically loaded fillet welded connection. The method of Instantaneous Center of Rotation results in weld resistance capacities greater than the vector analysis method, by recognizing the variation in fillet weld strength with respect to the direction of the applied loading and actual load-deformation response of elemental fillet welds. The procedure of numerical analysis is iterative and complex. The relations between vector analysis method and the method of Instantaneous Center of Rotation on eccentrical distance subjected to variation of load direction are presented in this paper. Considering of the effects on configuration of weld groups, the method of Instantaneous Center of Rotation are provided a more exact results of the numerical analysis.

  • PDF

Roll Motion Analysis of a 3 D.O.F. Planar Car Model using Instantaneous Centers (순간중심을 이용한 평면 3 자유도 자동차 모델의 롤 운동 해석)

  • Lee, Jae-Kil;Shim, Jae-Kyung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.14 no.4
    • /
    • pp.92-98
    • /
    • 2006
  • In this paper, a planar car model with 3 degrees of freedom was analyzed using the concept of the roll center. To avoid ambiguity, force components which require experimental data were excluded. Only kinematic approach was used to find the position and orientation of the vehicle body and the position of the roll center. The roll center was found by the pole with infinitesimal movement and Kennedy-Aronhold theorem. Centrodes, which are the loci of instantaneous centers of planar motion, were constructed with analyzed results to show characteristics of vehicle body motion. To verify the presented analysis method in this paper, the locus of the roll center and the motion of a 3 D.O.F. planar car model were compared with those of the 1 D.O.F. model.

A Method for Estimating an Instantaneous Phasor Based on a Modified Notch Filter

  • Nam Soon-Ryul;Sohn Jin-Man;Kang Sang-Hee;Park Jong-Keun
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.3
    • /
    • pp.279-286
    • /
    • 2006
  • A method for estimating the instantaneous phasor of a fault current signal is proposed for high-speed distance protection that is immune to a DC-offset. The method uses a modified notch filter in order to eliminate the power frequency component from the fault current signal. Since the output of the modified notch filter is the delayed DC-offset, delay compensation results in the same waveform as the original DC-offset. Subtracting the obtained DC-offset from the fault current signal yields a sinusoidal waveform, which becomes the real part of the instantaneous phasor. The imaginary part of the instantaneous phasor is based on the first difference of the fault current signal. Since a DC-offset also appears in the first difference, the DC-offset is removed trom the first difference using the results of the delay compensation. The performance of the proposed method was evaluated for a-phase to ground faults on a 345kV 100km overhead transmission line. The Electromagnetic Transient Program was utilized to generate fault current signals for different fault locations and fault inception angles. The performance evaluation showed that the proposed method can estimate the instantaneous phasor of a fault current signal with high speed and high accuracy.

Development of a Program That Computes the Position of the Instantaneous Center of Rotation on the Basis of Experimental Data(I) (실험 데이터를 이용한 회전운동 순간 중심점 분석 프로그램 개발(I))

  • Park, Jin;Shin, Ki-Hoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.4
    • /
    • pp.779-791
    • /
    • 2009
  • The purpose of this study is to develop a program that computes the position of the instantaneous center of rotation while an object moves in a circular motion. For this study, a mathematical algorithm was developed and implemented on the experimental data. Data for pitching (40m carry) and putting (4m) strokes were obtained from a skilled female golfer. A computer program (Centering 1.0) calculated the experimental data and found the radius of the instantaneous center of rotation. When the data were taken broadly, the program produced an error distance of radius. When the data were divided gradually, the program produced a very close instantaneous center of rotation. On comparing pitching and putting strokes, putting was found to have a greater radius than pitching. The instantaneous centers of rotation of putting were not in the golfer's body rather, they were 3m away from the club head. The Centering 1.0 program can calculate the instantaneous center of rotation with at least three sets of experimental data.

New Sensorless Vector Control for Permanent Magnet Synchronous Motor using instantaneous Reactive Power (순시 무효전력을 이용한 영구자석 동기전동기의 센서리스 제어)

  • Jun, Byoung-Ho;Choi, Yang-Kwang;Kim, Young-Seok;Shin, Jae-Wha;Han, Yoon-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.970-972
    • /
    • 2003
  • This paper presents a new speed sensorless control method of a permanent magnet synchronous motor based on instantaneous reactive power. The proposed algorithm is constructed by instantaneous reactive power in a synchronously rotating reference frame and is not affected by mechanical motor parameters, because mechanical equation is not used. The effectiveness of the proposed system is confirmed by the experimental results.

  • PDF

A Method to Prevent CO Poisoning from Instantaneous Water Heaters (순간 가스온수기의 CO 중독사고 예방에 관한 연구)

  • Ahan, Jeong-Jin;Yeo, Chang-Hoon;Jo, Young-Do
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.3
    • /
    • pp.26-30
    • /
    • 2011
  • Instantaneous water heater being not properly installed and not adequately maintained may produce fatal accidents due to carbon monoxide poisoning and suffocation. Insufficient supply of air into the gas appliance for complete burning of the fuel or blocking the outlet of the combustion gas could be a cause to increase carbon monoxide concentration in the exhaust gas of the gas appliance. In this work, the experiments are done with a collected instantaneous water heater using in domestic and the concentration of oxygen near the gas appliance and carbon monoxide in exhaust gas are observed to investigate the risk of instantaneous water heater. The concentration of oxygen near the gas appliance is reduced until 17.7% for the ratio of the ventilation area and floor area being 3.5%. If the outlet of combustion gas is blocked, the carbon monoxide concentration is steeply increasing more than 4,000ppm. Therefore, periodic checking the outlet of combustion gas is more important than vent area to reduce the risk of carbon monoxide poisoning.

Protection for a Wind Turbine Generator in a Large Wind Farm

  • Zheng, Tai-Ying;Kim, Yeon-Hee;Kang, Yong-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.4
    • /
    • pp.466-473
    • /
    • 2011
  • This paper proposes a protection algorithm for a wind turbine generator (WTG) in a large wind farm. To minimize the outage section, a protection relay for a WTG should operate instantaneously for an internal fault or a connected feeder fault, whereas the relay should not operate for an internal fault of another WTG connected to the same feeder or an adjacent feeder fault. In addition, the relay should operate with a delay for an inter-tie fault or a grid fault. An internal fault of another WTG connected to the same feeder or an adjacent feeder fault, where the relay should not operate, is determined based on the magnitude of the positive sequence current. To differentiate an internal fault or a connected feeder fault from an inter-tie fault or a grid fault, the phase angle of the negative sequence current is used to distinguish a fault type. The magnitude of the positive sequence current is then used to decide either instantaneous operation or delayed operation. The performance of the proposed algorithm is verified under various fault conditions with EMTP-RV generated data. The results indicate that the algorithm can successfully distinguish instantaneous operation, delayed operation, or non-operation depending on fault positions and types.

A Study on the Temperature Behavior of Impinging Plate in Impinging Spray with Ultra High pressure (극초고압 충돌분무시 충돌면의 온도거동에 관한 연구)

  • Jeong, Dae-Yong;Kim, Hong-Jun;Lee, Jong-Tai
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.442-447
    • /
    • 2003
  • The characteristics of instantaneous wall-surface temperature of impinging plate in case of ultra high pressure injection have been measured and analyzed by using thin film instantaneous temperature probe and ultra high pressure injection equipment. The decreasing rate of temperature was greater in case of higher temperature of impinging plate. Temperature drop was largest at center of piston and it was slight for others. Instantaneous temperature decreases rapidly with increasing injection pressure. But above 2,500bar of injection pressure, the decreasing rates are slightly affected by increasing injection pressure.

  • PDF

Vector Controlled Inverter for Elevator Drive (ELEVATOR 구동용 VECTOR 제어 인버터)

  • Shin, H.J.;Jang, S.Y.;Lee, S.J.;Lee, S.D.
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.627-630
    • /
    • 1991
  • This study is about vector controlled inverter for high quality elevator drive that is to improve the settling accuracy of elevator car and passenger's comfort in commercial buildings. In this study, an instantaneous space vector control type inverter was used to reduce the torque ripple ant to improve the velocity follow-up. This method calculates Instantaneous actual output torque and flux of induction motor by voltage and current, then compares them with a reference values by a speed regulator. The outputs of comparators select a switching mode, for an optimal voltage vector. Also, this study used IGBT (Insulated Gate Bipolar-Transistor), a high speed switching element, to reduce sound noise level, and DSP (Digital Signal Processor) was used to improve the reliability of the control circuit by fully digitalization.

  • PDF