• Title/Summary/Keyword: Installed performance

Search Result 2,743, Processing Time 0.032 seconds

A Sexual Knowledge and Attitude on the Exposure to PC Pornography of the Middle School Boys in Busan (남자중학생의 컴퓨터음란물 접촉자와 비접촉자간의 성지식과 태도의 차이)

  • Kim Y. H.;Lee H. Z.;Jung H. M.
    • Child Health Nursing Research
    • /
    • v.7 no.1
    • /
    • pp.62-73
    • /
    • 2001
  • The purpose of the study is to identify the differences about knowledge and attitude between the subjects exposed to pc pornography and the control group not exposed to pc pornography. The study was executed from July 12 through July 16. The subjects were 423 middle school boys. The comparison points were their ethical sexual knowledges and sexual attitudes. The collected data was analysed by SPSS WIN(including multiplicand, percentage, χ²-test, revised Fisher and t-test). The results of their study were as follows ; 1. The pc-related characteristics of the subjects. The subjects exposed pc pornography showed 51.8% rate of exposure to printed pornography. The control group showed the rate of 26.4%. The former group owned their pc(81.5%), however, the latter group showed 66.7%. The former group set their pc sets in their study rooms(66.1%) however, the latter group installed those in their study rooms(73.6%). The former group experienced internet pc communications(62.5%),however, the latter group showed 40.2%. The former group made use of their pc sets in recreation(entertainment) programs(77.0%), however, the latter group showed the rate of 67.8%. The former group showed that their school performance levelled up after their pc manipulation(80.0%), however, the latter group showed the rate of 86.2%. The former group replied that their pc manipulation contributed to their friendship(50.3%), however, the latter group showed the higher rate of 74.7%. The both groups replied that their family dialogs and contacts rather reduced (78.9% and 78.2% respectively). The both groups revealed that they reduced the TV watching the rate 76.5% and 48.3% respectively. The differences between two groups were surveyed in the level of 95% significance and the items such as 'contacts to printed pornography, pc possession or none, pc use rate, friendship occasions and the reduced time of TV watching' showed the significant differences. 2. The differences of two groups' sexual knowledges. As to the sexual knowledges, the both groups showed 41.1 and 34.1 points against 100 points respectively. The statistical differences were significant(t=2.72, p=.007). The 5 items among 17 showed the significant differences between two groups. 'The concept of masturbation' was χ²=5.033, p=.025. 'The prejudice to masturbation' showed χ²=9.902, p=.002 'The difference between female and male as to sexual excitement' showed χ²=7.985, p=.005. 'The positiveness of masturbation' showed χ²=10.205, p=.001. 'The differences between two sexes as to sexual impulse and sexual desire' showed χ²=8.463, p=.004. In conclusion, The former group showed the higher knowledges than the latter group. 3. The differences of two groups' sexual attitudes. The 4 items such as 'the curiosity to the other sex'(t=2.22, p=.027), 'the attention to pornography'(t=3.39, p=.001), 'the permission to pre-marriage intercourse'(t=2.15, p=.032) and 'the preference to the female body exposure'(t=2.67, p=.008) showed the differences between two groups as to sexual attitudes.

  • PDF

Computational Fluid Dynamics(CFD) Simulation for a Pilot-scale Selective Non-catalytic Reduction(SNCR) Process Using Urea Solution (요소용액을 이용한 파일럿규모 SNCR 공정에 대한 CFD 모델링 및 모사)

  • Nguyen, Thanh D.B.;Kang, Tae-Ho;Lim, Young-Il;Kim, Seong-Joon;Eom, Won-Hyeon;Yoo, Kyung-Seun
    • Korean Chemical Engineering Research
    • /
    • v.46 no.5
    • /
    • pp.922-930
    • /
    • 2008
  • The selective non-catalytic reduction(SNCR) performance is sensitive to the process parameters such as flow velocity, reaction temperature and mixing of reagent(ammonia or urea) with the flue gases. Therefore, the knowledge of the velocity field, temperature field and species concentration distribution is crucial for the design and operation of an effective SNCR injection system. In this work, a full-scale two-dimensional computational fluid dynamics(CFD)-based reacting model involving a droplet model is built and validated with the data obtained from a pilot-scale urea-based SNCR reactor installed with a 150 kW LPG burner. The kinetic mechanism with seven reactions for nitrogen oxides($NO_x$) reduction by urea-water solution is used to predict $NO_x$ reduction and ammonia slip. Using the turbulent reacting flow CFD model involving the discrete droplet phase, the CFD simulation results show maximum 20% difference from the experimental data for NO reduction. For $NH_3$ slip, the simulation results have a similar tendency with the experimental data with regard to the temperature and the normalized stoichiometric ratio(NSR).

LRB-based hybrid base isolation systems for cable-stayed bridges (사장교를 위한 LRB-기반 복합 기초격리 시스템)

  • Jung, Hyung-Jo;Park, Kyu-Sik;Spencer, Billie-F.Jr.;Lee, In-Won
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.8 no.3
    • /
    • pp.63-76
    • /
    • 2004
  • This paper presents LRB-based hybrid base isolation systems employing additional active/semiactive control devices for mitigating earthquake-induced vibration of a cable-stayed 29 bridge. Hybrid base isolation systems could improve the control performance compared with the passive type-base isolation system such as LRB-installed bridge system due to multiple control devices are operating. In this paper, the additional response reduction by the two typical additional control devices, such as active type hydraulic actuators controlled by LQG algorithm and semiactive-type magnetorheological dampers controlled by clipped-optimal algorithm, have been evaluated bypreliminarily investigating the slightly modified version of the ASCE phase I benchmark cable-stayed bridge problem (i.e., the installation of LRBs to the nominal cable-stayed bridge model of the problem). It shows from the numerical simulation results that all the LRB based hybrid seismic isolation systems considered are quite effective to mitigate the structural responses. In addition, the numerical results demonstrate that the LRB based hybrid seismic isolation systems employing MR dampers have the robustness to some degree of the stiffness uncertainty of in the structure, whereas the hybrid system employing hydraulic actuators does not. Therefore, the feasibility of the hybrid base isolation systems employing semiactive additional control devices could be more appropriate in realfor full-scale civil infrastructure applications is clearly verified due to their efficacy and robustness.

A numerical study on the performance of the smoke exhaust system according to the smoke exhaust method in emergency station for railway tunnel (철도터널 구난역의 제연방식에 따른 제연성능에 관한 수치 해석적 연구)

  • Ryu, Ji-Oh;Kim, Jin-Su;Seo, Jong-Won
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.6
    • /
    • pp.845-856
    • /
    • 2017
  • In the long railway tunnel, in order to secure safety in case of fire, it is required a emergency station. However, there is no standard or research results on smoke exhaust method and exhaust flow rate in emergency station, so it is necessary to study the smoke exhaust system for emergency station. In this study, we are created a numerical analysis model for emergency station where the evacuation cross passage connected to the service tunnel or the relative tunnel was installed at regular intervals (40 m intervals). And the fire analysis are carried out by varying the fire intensity (15, 30MW), the smoke exhaust method (only air supply, forced air supply and exhaust, forced air exhaust only), and the air flow rate (7, 14, $40m^3/s$). From the results of fire analysis, temperature and CO concentration are analyzed and ASET based on the limit temperature are compared at various condition. As a result, in the case with fire intensity of 15 MW, it is shown that a sufficiently safe evacuation environment can be ensured by applying forced air supply and exhaust method or forced air exhaust only method when the air flow rate is $7m^3/s$ above. In case of fire intensity of 30 MW, it is impossible to maintain the safety evacuation environment for more than 900 seconds when the exhaust air volume is below $14m^3/s$. And when the air flow rate is $40m^3/s$, the exhaust port is disposed at the side portion of the upper duct, which is most advantageous for securing the temperature-based safety.

Development of Air Cleaning Roll-Filter for Improving IAQ in Subway (도시철도 객실 공기질 개선을 위한 롤필터 개발연구)

  • Kwon, Soon-Bark;Park, Duck-Shin;Cho, Young-Min;Kim, Jong-Bum;NanGoong, Seok;Han, Tae-Woo;Cho, Kwan-Hyun;Kim, Tae-Sung
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.4
    • /
    • pp.313-319
    • /
    • 2011
  • In a modern society, various type of transportation modes are utilized, among them the subway system is the one of the main transportation mode which more than 7.21 million people ride a day in Seoul. Due to the increased interests on the indoor air quality (IAQ) of underground facilities, public concerns on IAQ of subway system are increasing also. Platform screen door (PSD) recently installed at the whole stations of Seoul subway and tunnel washing-out appeared to be effective in reducing particulate matters in the platform and tunnel. However there has not been any attempt to improve IAQ of subway cabin inside. Most technologies for removing airborne particulate matters are known to be difficult to adopt on the subway cabin due to the problem of maintenance cost. Therefore, the object of this study is a practical development of cabin air cleaning system which can reduce the concentration of airborne particles and harmful gases at the same time. In this paper, we focused on the development of particle removing system utilizing a roll-filter for increasing operating time of air filter. The prototype of system was designed and manufactured based on the numerical prediction results. For rollfilter device, 5 candidate filter materials were tested in point of particle collection efficiency and pressure drop. It was found that the electrically charged filter material showed the highest performance among them.

A Dynamic Signal Metering Algorithm Development for Vehicles and Pedestrians at Roundabouts (차량 및 보행자를 고려한 회전교차로 감응식 신호미터링 알고리즘 개발)

  • Lee, Sol;Ahn, Woo-Young;Lee, Seon-Ha
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.16 no.6
    • /
    • pp.53-66
    • /
    • 2017
  • In order to improve traffic flow and vehicular safety, installation of roundabouts is encouraging recently. Roundabouts are generally installed at which traffic flow and pedestrian flow is relatively low intersections. Roundabouts reduce vehicle speed, minimize vehicle weaving, and reduce critical conflict points. For these reasons, roundabouts are generally operated unprotected pedestrian crosswalk, thus a shortcoming for pedestrian safety always exists at roundabouts. The purpose of this study is developing a dynamic signal metering algorithm for traffic and pedestrian at four-way-approach with two-lane roundabouts in which three different operation algorithms(fixed-time pedestrian, vehicle signal metering, and vehicle and pedestrian signal metering) are suggested and its performance is tested by using VISSIM. The results of the fixed pedestrian signal operation show that there is a big average delay increase in general and that increases up to 51.4 seconds/vehicle(42.5%) when the total number of approaching vehicle is 3,800 vehicle/hour. However, the results of the simultaneous dynamic signal metering operation for the vehicle and pedestrian crossing with push button show that there is a substantial average delay reduction up to 40.6 seconds/vehicle(42.7%) when the total number of approaching vehicle is 3,000 vehicle/hour.

Hash-chain-based IoT authentication scheme suitable for small and medium enterprises (중소기업 환경에 적합한 해쉬 체인 기반의 IoT 인증 기법)

  • Jeong, Yoon-Su;Yon, Yong-Ho;Ku, Jin-Hee
    • Journal of Convergence for Information Technology
    • /
    • v.7 no.4
    • /
    • pp.105-111
    • /
    • 2017
  • With the emergence of the fourth industrial revolution, more and more attempts have been made to apply IoT technology to the manufacturing process and launch the product. In this paper, we propose IoT authentication scheme based on hash chain which can easily apply IoT device to small and medium enterprises in Korea. In the proposed method, the companies that installed IoT devices suitable for the manufacturing environment are selected to maintain the linkage between IoT devices so that product information and release information can be efficiently collected and managed during the entire manufacturing process. In addition, the proposed scheme is characterized in that it does not require an additional encryption / decryption algorithm because the authentication information of the IoT device is constructed based on a hash chain. As a result of the performance evaluation, the efficiency of the manufacturing process was improved by 18.5% and the processing of the manufacturing process with the IoT device was shortened by 20.1% on the average according to the application of the IoT device. In addition, the labor cost reduction costs in the manufacturing process decreased by an average of 30.7%.

Reactive Power Variation Method for Anti-islanding Using Digital Phase-Locked-Loop (DPLL을 이용한 능동적 단독운전방지를 위한 무효전력변동법)

  • Lee, Ki-Ok;Yu, Byung-Gu;Yu, Gwon-Jong;Choi, Ju-Yeop;Choy, Ick
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.2
    • /
    • pp.64-69
    • /
    • 2008
  • As the grid-connected photovoltaic power conditioning systems (PVPCS) are installed in many residential areas, these have raised potential problems of network protection on electrical power system. One of the numerous problems is an Islanding phenomenon. There has been an argument that it may be a non-issue in practice because the probability of islanding is extremely low. However, there are three counter-arguments: First, the low probability of islanding is based on the assumption of 100% power matching between the PVPCS and the islanded local loads. In fact, an islanding can be easily formed even without 100% power matching (the power mismatch could be up to 30% if only traditional protections are used, e.g. under/over voltage/frequency). The 30% power-mismatch condition will drastically increase the islanding probability. Second, even with a larger power mismatch, the time for voltage or frequency to deviate sufficiently to cause a trip, plus the time required to execute a trip (particularly if conventional switchgear is required to operate), can easily be greater than the typical re-close time on the distribution circuit. Third, the low-probability argument is based on the study of PVPCS. Especially, if the output power of PVPCS equals to power consumption of local loads, it is very difficult for the PVPCS to sustain the voltage and frequency in an islanding. Unintentional islanding of PVPCS may result in power-quality issues, interference to grid-protection devices, equipment damage, and even personnel safety hazards. Therefore the verification of anti-islanding performance is strongly needed. In this paper, improved RPV method is proposed through considering power quality and anti-islanding capacity of grid-connected single-phase PVPCS in IEEE Std 1547 ("Standard for Interconnecting Distributed Resources to Electric Power Systems"). And the simulation results are verified.

The study on scheme for train position detection based on GPS/DR (GPS/DR기반의 차상열차위치검지방안 연구)

  • Shin, Kyung-Ho;Joung, Eui-Jin;Lee, Jun-Ho
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.802-810
    • /
    • 2006
  • For a thorough train control, the precise train position detection is necessarily required. The widely used current way for train position detection is the one of using track circuits. The track circuit has a simple structure, and has a high level of reliability. However trains can be detected only on track circuits, which have to be installed on all ground sections, and much amount of cost for its installation and maintenance is needed. In addition, for the track circuit, only discontinuous position detection is possible because of the features of the closed circuit loop configuration. As the recent advances in telecommunication technologies and high-tech vehicle-based control equipments, for the train position detection, the method to detect positions directly from on trains is being studied. Vehicle-based position detection method is to estimate train positions, speed, timing data continuously, and to use them as the control information. In this paper, the features of GPS navigation and DR navigation are analyzed, and the navigation filters are designed by constructing vehicle-based train position detection method by combining GPS navigation and DR navigation for their complementary cooperation, and by using kalman filter. The position estimation performance of the proposed method is also confirmed by simulations.

  • PDF

GPS/INS Integration and Preliminary Test of GPS/MEMS IMU for Real-time Aerial Monitoring System (실시간 공중 자료획득 시스템을 위한 GPS/MEMS IMU 센서 검증 및 GPS/INS 통합 알고리즘)

  • Lee, Won-Jin;Kwon, Jay-Hyoun;Lee, Jong-Ki;Han, Joong-Hee
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.27 no.2
    • /
    • pp.225-234
    • /
    • 2009
  • Real-time Aerial Monitoring System (RAMS) is to perform the rapid mapping in an emergency situation so that the geoinformation such as orthophoto and/or Digital Elevation Model is constructed in near real time. In this system, the GPS/INS plays an very important role in providing the position as well as the attitude information. Therefore, in this study, the performance of an IMU sensor which is supposed to be installed on board the RAMS is evaluated. And the integration algorithm of GPS/INS are tested with simulated dataset to find out which is more appropriate in real time mapping. According to the static and kinematic results, the sensor shows the position error of 3$\sim$4m and 2$\sim$3m, respectively. Also, it was verified that the sensor performs better on the attitude when the magnetic field sensor are used in the Aerospace mode. In the comparison of EKF and UKF, the overall performances shows not much differences in straight as well as in curved trajectory. However, the calculation time in EKF was appeared about 25 times faster than that of UKF, thus EKF seems to be the better selection in RAMS.