• Title/Summary/Keyword: Installed performance

Search Result 2,743, Processing Time 0.027 seconds

Experimental Study of the Interaction Characteristics for a Marine CRP in LCT (LCT에서 선박용 상호반전 프로펠러 상호작용 특성의 시험적 연구)

  • Ahn, Jong-Woo;Kim, Ki-Sup;Park, Young-Ha;Lee, Chang-Hun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.54 no.2
    • /
    • pp.125-131
    • /
    • 2017
  • In order to develop test and performance analysis techniques for a CRP propulsion, a CRP dynamometer which can be installed inside the model ship was designed and manufactured. The object ship was the 16000TEU container carrier, which has test results for the single propeller. The design concept of the present CRP is that forward & after propellers have the same power ratio and their RPM ratio is 0.75:1. To begin with, we checked the performance of the CRP dynamometer through the calibration and then installed it inside the model ship. After the model ship setup including the design CRP and the rudder in the Large Cavitation Tunnel(LCT), a series of model tests composed of power ratio check, propeller behind wake(PBW) test, cavitation observation and pressure fluctuation tests was conducted. Through the model test and data analysis for CRP, the experimental technique was established and the improved method for CRP design was suggested.

An Experimental Study on Load Transfer Capacity for the Planar Joints between Existing and New Slab to Extend an Area of Remodelling apartment (리모델링 아파트의 평면확장시 신/구 슬래브 접합부의 횡방향 하중전달 능력에 관한 실험적 연구)

  • Lim, Byung-Ho;Kim, Seung-Hun;You, Young-Chan;Choi, Ki-Sun;Kang, In-Seok;Chung, Jae-Chul
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.25-28
    • /
    • 2006
  • In general, post-installed dowel bars are used as a shear connector to ensure the composite actions between new slabs and existing slabs in an apartment remodelling constructions expecially for enlarging the interior space outward the existing buildings. But, it has not been checked that the connection performance between existing and new slab is satisfactory not only for the structural safety condition but also the for serviceability and dwelling requirements. In this research, an experimental works were presented to evaluate the load transfer capacity for the planar joints between existing and new slab. The existing slabs were obtained from the existing apartment housing which will be demolished, and were retrofitted with carbon fiber plate. Test results showed that the planar joints with post-installed dowel bars behaved in full composite modes until ultimate capacity of test specimens, so sufficient ultimate and serviceability performance are confirmed.

  • PDF

The development and Performance test of the Cook Top type Gas valve for the slim-line style Gas Range (슬림라인형 가스레인지용 쿡탑형 가스 밸브의 개발과 작동 성능 검증)

  • Kim, Sang-Ju;Lee, Sang-Cheol;Ju, Kwang-Myung;Lee, Han-Jong;Chang, In-Bae
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.568-572
    • /
    • 2003
  • The height of valve body is limited to 30mm in the cook-top style gas valves for the domestic gas ranges. But the all the safety specifications of KS should be fulfilled and the magnetic power unit(MPU) should be installed in the valve body for the safety reason. The length of MPU body is longer than the 30mm that it should be located in the square direction of the knob shaft and therefore the implementation of the lever mechanism to transmit the press motion of the knob to the MPU valve is very difficult. In this paper, the hinged lever with inclined plate is used to transmit the press motion of the knob to the MPU valve. The analysis of the gas flow with using the commercial software of FLOW-3D shows that the gas flow capacity is fit for the domestic gas range. The performance and responsibility of the valve is tested for the mass production and the test results shows that the valve can be installed in the commercial gas range.

  • PDF

Evaluation of Power Performance by Anemometer on WTGS (풍력발전기 너셀에 장착된 풍속계를 이용한 출력성능 평가)

  • Kim, Soo-Sang;Park, Se-Kwang
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.303-310
    • /
    • 2012
  • We carried out the power performance evaluation for 1.5 MW${\times}$2 by using anemometer installed on WTGS(Wind Turbine Generator System) in the wind farm at Shi-hwa bang-a-mu-ri. In this paper, we compared and analyzed the performance of guaranteed output and measured output of WTGS which includes output curve, output coefficient, AEP(Annual Energy Product) and availability, etc.. The power performance of WTGS was optimized in the low wind speed sections(3 m/s ~ 10 m/s) and the measured output was more produced by AEP 109 % and availability 112 % than the guaranteed output. In addition, we could also cut the high cost of testing WTGS performance by using anemometer as a substitute for weather mast.

Empirical Evaluation of Wireless Mesh Networks for Construction IT in Tunnel Environments (건설-IT융합 기술을 위한 터널 환경에서 무선 메쉬 네트워크를 이용한 실험적 성능 검증)

  • Yang, Chang-Mo;Lee, Seung-Beom;Choi, Soo-Hwan;Eom, Doo-Seop
    • Journal of Information Technology Services
    • /
    • v.10 no.2
    • /
    • pp.271-279
    • /
    • 2011
  • This paper draws performance results through comparing WMNs' methods when the WMNs are used in tunnel construction sites. There are many advantages of WMNs : lower cost, easy to network maintenance, robustness and reliability within RF-ranges. As a result, using the WMNs would be suitable to employ as a network infrastructure for the construction sites. This paper evaluates the performance of WMNs which we have installed in a tunnel construction. Through the performance results, we conclude the performance of data throughputs gets lower when we perform the network in tunnel environments. We make attempts WMNs' two major methods which are SISC(Single Interface with Single Channel) and MIMC(Multi Interface with Multi Channel) to figure out which method will be better for the construction sites. Through the experiments, the WMN based on the MIMC method was comparatively suitable in network performance aspect for the tunnel Sites.

Research on Hydrodynamic Performance of the Interaction between Ducted Propeller and Rudder based on CFD

  • Xie, Yonghe;Wang, Guibiao;Wang, Wei
    • International Journal of Ocean System Engineering
    • /
    • v.3 no.4
    • /
    • pp.169-174
    • /
    • 2013
  • The computational fluid dynamics software FLUENT is used to calculate and compare the hydrodynamic performance of the propeller-rudder system of a 42-m trawler, which is installed with a ducted propeller. The effects of rudder on the hydrodynamic performance of the ducted propeller and the wake flow behind the propeller are firstly investigated. In addition, the different rudder angles are also considered to further study the performance of this system.

Study on the performance analysis of SCW geothermal system by simulation and monitoring (모니터링 및 시뮬레이션을 통한 SCW형 지열 시스템의 성능인자 분석에 관한 연구)

  • Lee, SangJun;Nam, Yujin
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.9 no.2
    • /
    • pp.8-15
    • /
    • 2013
  • Recently, an interest in the use of renewable energy has been growing up due to the rise of raw material price, international oil price and depletion of fossil energy. Ground source heat pump system has a high efficiency by using the constant temperature of underground and various types of the systems have been installed and utilized in the building. there are few studies on the system performance factors in the SCW system. Furthermore, even though the performance of the system depends on the temperature of heat source, the research on their relationship is rare. In this research, in order to analyze the performance factor for the open-loop system the monitoring of the real building with the standing column well systems and the simulation with building model were conducted.

Performance Prediction of Model Mixed Flow Pump Using Similarity (상사성을 이용한 model 사류펌프의 성능 예측)

  • Lee, Duck-Hyong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.393-400
    • /
    • 2005
  • As one of the useful and powerful methods for designing the optimum pump is using model pump, it is based on the similarity characteristics of turbomachinery. With this theory, we can predict the performance of various pumps. In fact we have performed huge pumps using this, the experimental results were to be sufficient to prove the similarity characteristics. In this study, we predicted the performance of the huge proto-type pump that cannot be installed and made a test. First of all, we had calculated the model ratio between proto-type and model. There were two ways to estimate the performance. One was the application of CFD code, and the other way was model field test. So We selected both of them to guarantee the dependable data and evaluated each other.

  • PDF

An Evaluation on Energy Recovery Performance of the Ventilation System in Multi-Residential Building by Field Measurement (실험을 통한 공동주택 환기시스템의 실제 운전 시 전열교환성능 검토)

  • Choi, Younhee;Song, Doosam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.2
    • /
    • pp.68-73
    • /
    • 2017
  • Recently, energy recovery ventilators (ERVs) have been installed for energy saving in many multi-residential buildings in Korea. The performance of the heat exchanger of an ERV is analyzed in this study under specific indoor and outdoor conditions in a test-cell measurement. However, the performance of the heat exchanger varies according to the indoor and outdoor condition. In this study, the performance of energy recovery of the ventilation system was therefore analyzed in actual weather conditions using field measurement. Experiments were conducted under winter conditions in a multi-residential building for 20 days. Based on the measurement results, the characteristics of sensible heat and latent heat exchange rates were analyzed.

Performance Analysis of a Mixed-Flow Pump for Waterjet Propulsion

  • Ahn Jong-Woo;Kim Ki-Sup;Park Young-Ha;Kim Kyung-Youl;Oh Hyoung-Woo
    • Journal of Ship and Ocean Technology
    • /
    • v.9 no.2
    • /
    • pp.11-20
    • /
    • 2005
  • A mixed-flow pump is largely applied for waterjet propulsion in high-speed vessels because of excellent cavitation performance. For the present study, we analyze the performance of mixed-flow pump, which is composed of impeller and stator. The test device for a mixed-flow pump was installed in the test section in the KRISO cavitation tunnel. The performance tests of two mixed-flow pumps were carried out with the test device at various flow rates using various nozzles. The test results agree fairly well with the predicted results by commercial CFD code. The test device is available for verification of impeller performance together with CFD analysis