Thermal Dissipation Characteristics of Multi-Chip LED Packages (멀티 칩 LED 패키지의 방열 특성)

  • Kim, Byung-Ho;Moon, Cheol-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.12
    • /
    • pp.34-41
    • /
    • 2011
  • In order to understand the thermal performance of each LED chips in multi-chip LED package, a quantitative parametric analysis of the temperature evolution was investigated by thermal transient analysis. TSP (Temperature Sensitive Parameter) value was measured and the junction temperature was predicted. Thermal resistance between the p-n junction and the ambient was obtained from the structure function with the junction temperature evolution during the cooling period of LED. The results showed that, the thermal resistance of the each LED chips in 4 chip-LED package was higher than that of single chip- LED package.

Analysis of soil discharge characteristics in sand with water content (수분 함유량에 따른 모래의 지중방전 특성 분석)

  • Lee, Bok-Hee;kim, Hoe-Gu;Park, Geon-Hun;Lee, Kyu-Sun;Ahn, Chang-Hwan
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.436-439
    • /
    • 2008
  • It has been known that the value of soil resistance drops when a high impulse curennt is injected into a grounding electrode. In this paper, impulse generator is used to investigate the dry soil and wet soil characteristics in cylinderical test cell. The impulse resistances and breakdown characteristics were discussed based on its voltage and current traces. As a result, sand resistances are decreased with increasing the applied currents. It was thought that a decrease in resistance of dry sand with increasing current is due to both thermal and ionization processes. On the other hand, in case there is no water presence in the soil, the reduction in resistance as the currents are of dry sand increased is mainly due to the ionization process.

  • PDF

Decoupling Control of an Induction Motor with Recursive Adaptation of Rotor Resistance ((재귀)궤환형 회전자 저항 추정기를 갖는 유도전동기의 비간섭제어)

  • 김규식
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.3
    • /
    • pp.99-103
    • /
    • 1998
  • We propose a nonlinear feedback controller that can control the induction motors which have been applied to many electrical facilities with high dynamic performance by means of decoupling of moor speed and rotor flux. The nonlinear feedback controller needs the information on some motor parameters. Among them, rotor resistance varies greatly with machine temperature. Anew recursive adaptation algorithm for rotor resistance which can e applied to our nonlinear feedback controller is also presented in this paper. To demonstrate the practical significance of our results, we present some experimental results.

  • PDF

Design of An Electronic Starter Using PSpice Simulation (PSpice 시뮬레이션을 이용한 전자식 스타터의 설계)

  • 이동호;곽재영;여인선;정영춘
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1997.10a
    • /
    • pp.11-13
    • /
    • 1997
  • Abstract - An electronic starter using MOSFET has been designed to take advantage of ideal preheating and starting features which can extend the lifetime of fluorescent lamps. The preheating circuit of the developed electronic starter is consisted of four parts - afull-wave rectifier circuit, an FET switching circuit a timer circuit for the gate switching, and a circuit for end-of-life protection. The circuit is analyzed by using PSpice simulation, and is improved to give an appropriate starting-time through control of R-C time constant of the timer circuit. And the circuit is also provided with an end-of-life protection feature, which utilizes the negative resistance characteristics of a thermistor that is thermally linked to FET through a heatsink. This also protects the FET from any overheating problems. From the results of simulation it is possible to obtain an appropriate value on the starting time for proper ignition and also it is verified that the limit for resistance of the thermistor is dependant on the value of resistance is the timer circuit

  • PDF

Theoretical Analysis of Earth Deep-Driven Rod and Earth Slight-Driven Parallel Rods in the Earth (심타접지와 천타병렬접지에 관한 이론적해석)

  • Kim, Ju-Chan;Choi, Jong-Kyu;Lee, Chung-Sik;Koh, Hee-Seog
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.358-360
    • /
    • 2004
  • To reduce the earth resistance, earth electrode are installed horizontally or vertically in the earth. There are two kinds of vertical earth electrode methods, one is a deep-driven rod and another is slight-driven parallel rods. Bibliography have so far analyzed the earth resistance calcalation of a rod type electrode and parallel rods type for the multi-layered earth. Befor long, We are going to study earth resistance of deep-driven rod and slight-driven parallel rods in the multi-layered earth with reference to bibliography.

  • PDF

The Effect by Grounding Resistance of the ground Fault in the 22.9[kV] Multi-ground Distribution System (22.9[kV] 다중접지 배전계통에서 고장전류의 접지저항 영향 분석)

  • Jung, Kum-Young;Choi, Sun-Kyu;Shim, Keon-Bo;Kim, Kyung-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.10
    • /
    • pp.85-89
    • /
    • 2010
  • During a ground fault the maximum fault current and neutral to ground voltage will appear at the pole nearest to the fault. Distribution lines are consisted of three phase conductors, an overhead ground wire and a multi-grounded neutral line. In this paper phase to neutral faults were staged at the specified concrete pole along the distribution line and measured the ground fault current distribution in the ground fault current, three poles nearest to the fault point, overhead ground wire and neutral line. A effect by grounding resistance of poles of ground fault current in the 22.9[kV] multi-ground distribution system. by field tests.

Design a System for Analysis of Distributing Board with Grounding Resistance (배전반 접지저항 해석을 위한 시스템 설계)

  • Ko, Bong-Woon;Boo, Chang-Jin;Choi, Seung-Joon;Jeong, Kwang-Ja
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.380-383
    • /
    • 2009
  • The grounding system of the subsurface should ensure the safe and reliable operation of power systems, and guarantee a human being's safety in the situation of grounding fault in the power system. The safety of power apparatus in the subsurface can be reached by decreasing grounding resistance and grounding potential rise of subsurface. This paper presents a method based on the design of an artificial neural network(ANN) model for modeling and predicting the relationship between the grounding resistance and temperature-humidity in the subsurface.

  • PDF

The Variations of Grounding Resistance of the Vertical Electrodes by Soil Models (대지구조 모델에 따른 봉형 접지전극의 접지저항값 변화)

  • Shim, Keon-Bo;Kim, Won-Bae;Seo, Gil-Mo;Cho, Geum-Bae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.9
    • /
    • pp.57-63
    • /
    • 2012
  • The basic purpose of grounding is for human safety and normal operation of system related to electrical shock hazard by faults of electrical equipments. A grounding electrode is defined as a conducting element that connects electrical systems and/or equipment to the earth. The lowest possible resistance connection to the earth is sought from the grounding electrode. The grounding electrode is the foundation of the electrical safety system. The resistance to ground of vertical electrodes buried in the two deference soil structures has been analyzed for a length of electrodes and soil parameters. The equation of ground resistance of vertical electrodes are Tagg's equation for uniform soil models, and modified equation of Dwight equation for two-layer soil model. In this paper, compared with results of two equations are calculated values of vertical electrode in uniform and two-layer soil models.

A Comparison of Image Reconstruction Techniques for Electrical Resistance Tomography (Electrical Resistance Tomography의 영상복원 기법의 비교)

  • Kim, Ho-Chan;Boo, Chang-Jin;Lee, Yoon-Joon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.3
    • /
    • pp.119-126
    • /
    • 2005
  • Electrical resistance tomography(ERT) maps resistivity values of the soil subsurface and characterizes buried objects. The characterization includes location, size and resistivity of buried objects. In this paper, Gauss-Newton, truncated least squares(TLS) and simultaneous iterative reconstruction technique(SIRT) methods are presented for the solution of the ERT image reconstruction. Computer simulations show that the spatial resolution of the reconstructed images by the TLS approach is improved as compared to those obtained by the Gauss-Newton and SIRT method.

Rotor Resistance Estimation of Induction Motor by ANN (ANN에 의한 유도전동기의 회전자 저항 추정)

  • Ko, Jae-Sub;Choi, Jung-Sik;Chung, Dong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.10
    • /
    • pp.27-34
    • /
    • 2006
  • This paper proposes a new method of on-line estimation for rotor resistance of the induction motor in the indirect vector controlled drive, using artificial neural network (ANN). The back propagation algorithm is used for training of the neural networks. The error between the desired state variable of an induction motor and actual state variable of a neural network model is back propagated to adjust the weight of a neural network model, so that the actual state variable tracks the desired value. The performance of rotor resistance estimator and torque and flux responses of drive, together with these estimators, are investigated variations rotor resistance from their nominal values. The rotor resistance are estimated analytically, using the proposed ANN in a vector controlled induction motor drive.