• 제목/요약/키워드: Installation depth

검색결과 361건 처리시간 0.026초

우물관정(SCW: Standing Column Well)형 냉난방 시스템의 지중열 해석과 실증 실험에 관한 연구 (Research of geothermal analysis and experimental test for Standing Column Well type system)

  • 권익상;홍기배
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.173-173
    • /
    • 2010
  • This thesis identified basic design elements (Sustainable Yield, Temperature of Groundwater, Depth of Well, Separation Distance between wells) regarding installation of Standing Column Well, Geothermal Heat pump System by dynamic analysis.

  • PDF

우물관정(SCW: Standing Column Well)형 지열 냉난방 시스템 설계를 위한 지중열 해석에 관한 연구 (Research for geothermal analysis on design of Standing Column Well type system)

  • 권익상;이건중;김태원
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 추계학술대회 논문집
    • /
    • pp.576-580
    • /
    • 2009
  • This thesis identified basic design elements(Sustained Yield, Depth of Well, Separation Distance between wells) regarding installation of Standing Column Well, Geothermal Heat pump System by dynamic analysis.

  • PDF

Natural frequency of bottom-fixed offshore wind turbines considering pile-soil-interaction with material uncertainties and scouring depth

  • Yi, Jin-Hak;Kim, Sun-Bin;Yoon, Gil-Lim;Andersen, Lars Vabbersgaard
    • Wind and Structures
    • /
    • 제21권6호
    • /
    • pp.625-639
    • /
    • 2015
  • Monopiles have been most widely used for supporting offshore wind turbines (OWTs) in shallow water areas. However, multi-member lattice-type structures such as jackets and tripods are also considered good alternatives to monopile foundations for relatively deep water areas with depth ranging from 25-50 m owing to their technical and economic feasibility. Moreover, jacket structures have been popular in the oil and gas industry for a long time. However, several unsolved technical issues still persist in the utilization of multi-member lattice-type supporting structures for OWTs; these problems include pile-soil-interaction (PSI) effects, realization of dynamically stable designs to avoid resonances, and quick and safe installation in remote areas. In this study, the effects of PSI on the dynamic properties of bottom-fixed OWTs, including monopile-, tripod- and jacket-supported OWTs, were investigated intensively. The tower and substructure were modeled using conventional beam elements with added mass, and pile foundations were modeled with beam and nonlinear spring elements. The effects of PSI on the dynamic properties of the structure were evaluated using Monte Carlo simulation considering the load amplitude, scouring depth, and the uncertainties in soil properties.

벨마우스 깊이가 다른 3차원 소형축류홴의 공력특성에 대한 대규모 와 모사 (Large Eddy Simulation on the Aerodynamic Performance of Three-Dimensional Small-Size Axial Fan with the Different Depth of Bellmouth)

  • 김장권;오석형
    • 동력기계공학회지
    • /
    • 제19권6호
    • /
    • pp.19-25
    • /
    • 2015
  • The unsteady-state, incompressible and three-dimensional large eddy simulation(LES) was carried out to analyze the aerodynamic performance of three-dimensional small-size axial fan(SSAF) with the different depth of bellmouth. The static pressure coefficients analyzed by LES predict a little bit larger than measurements except stall region regardless of the installation depth between SSAF and bellmouth. Moreover, static pressure efficiencies analyzed by LES show about maximum 30% at the actual operating point ranges, but measurements do not. Therefore, if the blades of conventional SSAF have some more rigidity and complete dynamic balance, the aerodynamic performance of SSAF will be some more improved. In consequence, LES shows the best prediction performance in comparison with any other Reynolds averaged Navier-Stokes(RANS) method.

매입기초와 토질에 따른 인발저항력 특성 (Characteristics of Uplift Capacity of a Embedded Foundation and Soil Type)

  • 임성윤;김유용;유석철;김명환
    • 한국농공학회논문집
    • /
    • 제61권3호
    • /
    • pp.23-30
    • /
    • 2019
  • In this study, we evaluated the applicability of proper embedded depth of fillings by examining the uplift resistance using spiral foundation and top base foundation. As a result of the model test, the maximum uplift resistance increased with the embedded depth. The maximum uplift resistance of each region was found to be 50cm depth. The spiral foundation was 335.14N of Sancheong, 312.32N of Seongju, 403.94N of Wanju, and the top base foundation was 745.06N of Sancheong, 1028.82N of Seongju and 950.76N of Wanju. The yield point after the elastic section in the stress-displacement graph of the top base foundation was calculated as the maximum uplift resistance. For this reason, farmers do not actually use top bases foundation. Therefore, it was considered that the additional load increase due to slip connector will not occur. Model test results show that the maximum uplift resistance increases with the purlinss installed under the ground. Therefore, additional comparative studies through purlins installation will be needed.

원환 설치에 의한 원형교각 주위의 수리특성변화 (Variation of Hydraulic Characteristics around a Cylindrical Bridge Pier with Circular Collar)

  • 진병호;심우배;송재우
    • 한국방재학회 논문집
    • /
    • 제3권2호
    • /
    • pp.147-154
    • /
    • 2003
  • 본 연구에서는 수리모형실험을 통하여 원환 설치 전 후 교각 주위의 수리특성을 분석하였다. 하천 흐름에서 교각 전 후의 수위 변화를 분석한 결과, 교각 전면부에서 원환 설치 전 후의 수위차는 약 0.2cm, 교각 후면부에서 원환 설치 전 후의 수위차는 약 0.1cm로 거의 변화가 없었다. 따라서, 원환이 하천 흐름에 장애가 되지 않는 것으로 판단되었다. 또한, 교각 전 후의 유속 변화를 분석한 결과, 교각 전 후면부에서 원환 설치 전 후의 흐름방향 유속(u)과 횡방향 유속(v)은 변화를 보이지 않았으며, 교각 전면부에서 연직방향 유속(w)은 수심비(y/D)가 0.33인 지점에서 약 16.72% 최대감소효과를 나타냈으며, 교각 후면부에서 연직방향 유속(w)은 수심비(y/D)가 0.67인 지점에서 약 15.83% 최대감소효과를 나타내었다. 원환을 설치했을 경우 교각 주위에서 세굴을 일으키는 하강류의 발생을 억제함으로써 국부세굴심을 감소시킬 수 있을 것으로 판단되었다.

가상주행실험 기반 운전자 시각행태에 따른 옐로카펫 설치 효과 분석 (Analysis of the Effect of Yellow Carpet Installation according to Driving Behavior with Eye Tracking Data)

  • 주성갑;김도훈;문혜민;최호민
    • 한국ITS학회 논문지
    • /
    • 제22권5호
    • /
    • pp.43-52
    • /
    • 2023
  • 옐로카펫 보급된 이후 어린이 교통사고는 감소세이나 아직 옐로카펫 설치와 교통사고간의 인과관계에 대한 설명력은 부족한 상황이다. 기존의 실차조사연구에서 상황 구현의 어려움이나 위험성 등의 이유로 수행하지 못한 다양한 상황을 VR시뮬레이션 실험을 활용하여 옐로카펫 효과를 더욱 심도있게 분석하였다. 실제 옐로카펫이 설치되어있는 대상지를 선정하고, 가상환경으로 구현한 후 시선측정장비를 착용하고 시뮬레이터에 탑승하도록 하였다. 옐로카펫 설치 전·후의 시각/주행행태를 비교하였고, 통계적 검증을 위해 t-test 분석을 수행, 모두 통계적으로 유의한 수준인 것으로 나타났다.

실내실험과 현장실험을 통한 Methylene Blue 동결깊이 측정장치 신뢰성 검토에 관한 연구 (Experimental and Field Investigations for the Accuracy of the Frost Depth Indicator with Methylene Blue Solution)

  • 김학승;이장근;김영석;강재모;홍승서
    • 한국지반신소재학회논문집
    • /
    • 제12권3호
    • /
    • pp.75-79
    • /
    • 2013
  • 동결깊이는 영구 동토지역 및 계절성 동토지역에서 도로의 동상방지층, 매설관의 깊이 및 건물의 기초를 설계하는데 중요한 고려사항이다. methylene blue 동결깊이 측정장치는 지중 온도센서를 이용한 계측시스템과 비교하여 저렴하고 유지관리와 측정이 용이한 장점을 지니고 있다. 그러나 지반공학적 관점에서 지중에 매설된 methylene blue 동결깊이 측정장치의 신뢰성을 검토한 연구는 미미하다. 본 논문에서는 실내실험과 현장실험을 통해 methylene blue 동결깊이 측정장치의 신뢰성을 검토하고, 나아가 국내 현장에서 검증된 측정장치로 장기간 측정된 동결깊이 실측 데이터를 이용하여 최대 동결깊이 분포도를 작성하였다. 본 연구를 바탕으로 실측된 동결깊이는 향후 국내 지반구조물 설계에 중요한 자료로 활용될 수 있을 것으로 판단된다.

축소형 모델 접지전극의 매설깊이에 따른 위험전압의 분석 (Analyses of Hazard Voltages According to the Buried Depth of Small-sized Model Grounding Electrode)

  • 백영환;이복희
    • 조명전기설비학회논문지
    • /
    • 제23권4호
    • /
    • pp.56-61
    • /
    • 2009
  • 본 논문은 축소형 모델 접지전극이 접속된 금속제 구조물 주변의 대지표면전위분포와 위험전압에 대하여 기술하였다. 접지에 관련된 문제를 실제 현장데이터로부터 적정한 결론을 도출하기는 매우 어려우므로 접지전극 주변의 전위분포와 접촉전압, 보폭전압의 산정에 축소형 모델시험을 사용한다. 본 연구에서는 균질토양을 모의하기 위해 직경이 1,100[mm] 반구형 용기를 사용하였다. 실험결과, 접지전극 주변의 대지표면전위는 매우 높게 나타났으며, 특히 접지전극의 직상부의 대지표면전위는 다른 위치에 비해 높게 나타났다. 접지전극의 매설깊이가 증가함에 따라 대지표면전위와 보폭전압은 낮아지지만 접촉전압은 높아지는 것으로 나타났다.

전주의 실물인장실험시 토압계를 이용한 수평토압분석 (Horizontal Stress Analysis of Electric Pole using Earth Pressure Cell from Mock-Up Tension Test)

  • 안태봉
    • 조명전기설비학회논문지
    • /
    • 제24권8호
    • /
    • pp.62-69
    • /
    • 2010
  • 연약지반에 시공하는 많은 콘크리트전주가 외부하중으로 전도파괴가 발생하는데 본 연구에서는 실물인장실험을 실시하고 근가위치, 근가깊이, 근가개수, 전주근입깊이를 달리하면서 전주에 작용하는 수평토압을 분석하였다. 실물실험은 10가지 종류로 나누어 실험한 결과 수평토압은 전주 근입깊이가 클수록 커지고 하부수동영역이 길어지는 것으로 나타났다. 근가 설치위치가 깊을수록 하부수동영역 토압이 감소된다. 근가의 수를 4개 설치한 것이 G.L-0.9[m] 위치에서의 토압을 크게 줄였는데 이는 수직으로 80[cm]정도에 걸쳐 설치된 근가의 영향으로 판단되나 전체적으로 볼 때 근가의 수는 큰 차이가 없으며 근가를 다수 설치하면 굴착면적이 커져 되메우기 등 시공성이 떨어지는 단점이 있으므로 근가를 1개만 설치하여도 좋은 것으로 판단된다.