• 제목/요약/키워드: Installation Standards

검색결과 514건 처리시간 0.024초

건축전기설비 관련 규정의 국제화 동향 분석 (The Trand analysis of the International Standard of the Building Electrical Installations)

  • 이기홍
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.93-95
    • /
    • 2003
  • Owing to WTO/TBT, Many countries are trying to accord their own various national codes and standards with international standards. Also Korean electric power code is being made consistent with the new standards which include the international standards. The new code will affect the many aspects of building construction. In order to cope with the change of the electric power code, this paper analyzed the trend of the international standard(IEC 60364, IEC 61024) and we think this study will help engineers to understand the international electrical standards.

  • PDF

BF 인증을 위한 경사로 설치기준 개선에 대한 연구 (A Study on Improvement of Ramp Installation Standard for BF Certification)

  • 신동홍
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제26권2호
    • /
    • pp.31-38
    • /
    • 2020
  • Purpose: The ramp is an important facility for the barrier free access and vertical circulation of users of various buildings, including users of walker, wheelchair users, stroller users, and baggage carriers. The installation standards for ramps in Korea have various problems during construction and BF certification. It is necessary to improve the criteria for ensuring practical mobility and safety. Method: Korean standard, International Standard(ISO 21542, 2011), German Standard(DIN 18040-1, 2010), Austrian Standard(OENORM B 1600, 2017), Swiss Standard(Norm SIA 500, 2009), Canadian Standard(Building Standards Guide, 2017), American Standard(ADA Standards, 2010) were investigated and analyzed. A comprehensive improvement of the ramp installation standards is proposed. Results: The ramp is a necessary facility for the barrier free access and vertical circulation of the disabled. It shall be installed with comprehensive consideration of the appropriate slope of the ramp, the distance of the continuous slope, the handle and upstand for pedestrian safety. In order to improve convenience, setting the proper slope and limiting the length of the slope are very important, and improvements are required to the levels presented by international and foreign standards. The unclear standards of Korean law and BF certification standards should be clearly improved so as not to be misinterpreted in construction and Barrier Free Certification. Implication: International and foreign standards should be reviewed to ensure practical mobility and safety. And comprehensive improvement measures should be presented through continuous research.

가스보일러 배기시스템 설치 기준 분석 및 개발 (가스보일러 배기시스템 관련 설치 안전기준 개발II) (Analysis and Development for Installation Safety Standard on Gas Boiler Exhaust System)

  • 이수정;최경석;채충근;김하나;윤진선
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2014년도 제49회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.111-112
    • /
    • 2014
  • Exhaust gas boiler system with respect to national and international safety standards, comparative study best suited to the realities of local exhaust and exhaust system manufacturing, certification standards and gas boiler installation, management, and mip draft inspection standards will proceed through this study.

  • PDF

ISO 9000 시리즈의 적용범위 및 품질시스템 구성 요소 (ISO 9000 Series Standards and Quality System Requirements)

  • 전영호
    • 산업공학
    • /
    • 제7권2호
    • /
    • pp.25-30
    • /
    • 1994
  • ISO 9000 is a series of several standards(ISO 8402, 9000, 9001, 9002, 9003, 9004,...). ISO 9000 is a standard explaining fundamental concepts, defining important terms, and providing guidance for selecting among the other standards. ISO 9001, the most comprehensive standard to ensure quality in design, development, production, installation, and servicing. ISO 9002 is used to assure conformance to specification, installation and servicing. ISO 9003 has the least requirement among three standards and applies to inspection and final testing. ISO 9004 is a standard developed for internal use only and not applicabe to contractual arrangements. In this paper, quality system requirements for ISO 9000 series are also specified.

  • PDF

드론택시(UAM)의 수직이착륙장(Vertiport) 설치기준 연구 (A Study on Vertiport Installation Standard of Drone Taxis(UAM))

  • 최자성;이석현;백정선;황호원
    • 한국항공운항학회지
    • /
    • 제29권1호
    • /
    • pp.74-81
    • /
    • 2021
  • UAM(Urban Air Mobility) systems have evolved in the form of helicopters in the 1960~1970s, tiltrotors in the 1980s, small aircraft transportation systems in the 2000s, and electric-powered Vertical Take-Off and Landing (eVTOL) in the 2010s; accordingly, the early heliport has evolved to its current form of a Vertiport. Vertical Takeoff and Landing Sites, Vertiports, are important factors for the successful introduction of UAM, along with the resolution of air traffic control (ATC), air security, and noise problems. However, there are no domestic or international installation standards and guidelines yet. Therefore, in this study, installation standards were prepared by referring to domestic and international case studies, ICAO standards, and MIT research papers. The study proposes to establish standards for Final Approach and Takeoff Area (FATO) as 1.5D, 1D for Touchdown and Lift-Off Area (TLOF), and 1.5D for Safety Area (SA). It also proposes to add "UAM Vertiport Installation Standards" to the 「Act on the Promotion and Foundation of Drone Utilization, Drone Act」.

저압 전기설비의 과전압 억제 필요성 판단 (Judgement of the need for Over-Voltage Control of the Low-Voltage Electrical Installations)

  • 이주철;김재철
    • 조명전기설비학회논문지
    • /
    • 제29권2호
    • /
    • pp.91-96
    • /
    • 2015
  • There are provision for risk analysis in IEC standards. It is to determine the need for installation of a surge protection device (SPD) in order to protect the low-voltage electrical installations from overvoltages caused by atmospheric phenomena and the like. However, scattered many related standards, the lack of details are not easy to apply it in the field. We investigated the relevant domestic and international standards for applies to the international standards in domestic. And we proposed the flow chart for determining the need for protection of the low-voltage electrical installations from overvoltage due to atmospheric phenomena and it set the appling target facility.

고령자를 위한 교회 편의시설 설치기준의 중요도에 대한 주체별 인식의 간극 (Perceptive Gap among Interest Groups to Significance of the Installation Standards of Churches' Convenience Facilities for the Elderly)

  • 이종희;김덕수
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제19권1호
    • /
    • pp.47-57
    • /
    • 2013
  • Purpose: The purpose of this study is to provide reference points for the improvement work of churches' convenience facilities for the elderly. To do this, the study generates survey results, showing that the perception to significance of churches' convenience facilities is different among survey constituents. Method: The survey method was utilized. The study population for survey includes the aged believer over 65 years old, pastors, and architecture and/or interior design experts. The questionnaire was devised while consulting existing regulations regarding convenience facilities in general. Results: It is found that the perception to significance of installation standards for convenience facilities is different among survey constituents. Specifically, while the older believer group is perceived that installation standards for the small group meeting room of 'other facility' is comparatively more important, the pastor group and the expert group perceive that the 'intermediate facility' and 'inner facility' are more important. Implications: Participants involved in an improvement project of churches' convenience facilities may have a different perception about their importance due mainly to the degree of usage and the difference of perspectives. This study, therefore, can be used as a reference point for prioritizing improvement works of churches' convenience facilities for the elderly.

접지에 관한 용어의 실태와 일관성 있는 사용을 위한 고찰 (A Study on the Present State and Consistent use of Terminologies Concerning Grounding)

  • 이복희;이강희;김태기;김한수
    • 조명전기설비학회논문지
    • /
    • 제27권4호
    • /
    • pp.81-87
    • /
    • 2013
  • A grounding scheme is one of important parts in protection for safety of electrical installations. Terminologies are successively creating and gradually increasing due to diversity and external environments. The declaration and definition of terminologies concerning grounding are in disorder in several KS standards, electrotechnical provisions for electrical installations and electrotechnical guides related to electrical installations. There seem to be serious confusions in use among technicians and experts. In this paper, we proposed a new scheme and system to consistently use the technical terms concerning grounding described in KS standards and technical provisions. Different use examples and the present state of terminologies on grounding described in Korean documents such as KS IEC standards, technical provisions for electrical installations, consumer's electrical installation guide, and etc are investigated. Although the scope of this work is limited to examine the terminologies on grounding, it is expected that the proposed method could be contributed to the consistent use of terminologies in all areas in KS C IEC standards and technical provisions for electrical installations.

방폭설비 성능유지 실태분석을 통한 관리방안 연구 (A Study on the Management Plan through Performance Maintenance Analysis of Explosion-proof Facilities)

  • 권용준;변정환
    • 한국안전학회지
    • /
    • 제35권2호
    • /
    • pp.8-16
    • /
    • 2020
  • In Article 311 of the Regulation on Occupational Safety and Health Standards requires the use of Korean Industrial Standards Act in accordance with the Industrial Standardization Act. However, the classification, inspection, maintenance, design, selection, and installation of explosion hazard locations for explosion and explosion prevention and internalization of 'safety' in the performance maintenance phase of electrical machinery and equipment There is no technical and institutional management plan for remodeling and alteration. Analysis of actual conditions and problems related to the installation, use, and maintenance of explosion-proof equipment, comparative analysis of domestic and international technical standards and systems, technical, institutional and administrative systems and systems related to installation, use, and maintenance of explosion-proof equipment, technical personnel and qualifications, etc. It is to propose legislation, system improvement, and technical standard establishment related to the maintenance of explosion-proof facility performance through improvement of the necessity and feasibility study for establishment of the legal status of the management site and management plan. As technical measures, KS standard revision (draft), KOSHA guide (draft) and explosion-proof facility performance maintenance manual were presented. In addition, the institutional management plan proposed the revised rule on occupational safety and health standards, the revised rule on the restriction of employment of hazardous work, and the manpower training program related to the maintenance of explosion-proof facilities and the qualification plan. Enhance safety at the installation, use, and maintenance stage of explosion-proof structured electrical machinery. It is expected to be used to classify explosion hazards, select related equipment, and to update and standardize standards related to installation, use and maintenance.

횡단보도의 시인성 향상을 위한 기준검토 및 검증 테스트를 통한 보완 기준(안) 연구 (The Study of Complementary Standards to Improve Visibility on Crosswalk throughout Verification Studies after Reviewing Standards)

  • 이미애;이동희;이윤경
    • 조명전기설비학회논문지
    • /
    • 제28권8호
    • /
    • pp.14-23
    • /
    • 2014
  • According to the analysis of crosswalk pedestrian accidents, accidents that occur at night represent 70% of all deaths among crosswalk pedestrians when compared to accidents occurring in the daytime. This is due to the poor visibility that hinders drivers to recognize pedestrians at night. Illuminance on the horizontal plane of the road and the current state of crosswalk lighting are not sufficient enough to comply with standards. Thus, we analyzed factors derived from lighting environment studies on improving crosswalk visibility, domestic and foreign crosswalk lighting standards, and subsequently proposed solutions which are needed to raise domestic crosswalk lighting standards, and a means to uphold those standards through proper verification.