• Title/Summary/Keyword: Installation Effect

Search Result 1,466, Processing Time 0.026 seconds

The Improvement Effect of Pinus densiflora Forest Disturbed by Human Trampling in the Solbat Neighborhood Park, Gangbuk-gu, Seoul (서울시 강북구 솔밭근린공원 소나무림 답압 피해 개선사업 효과 연구)

  • Kwon, Ki-Young;Han, Bong-Ho;Park, Seok-Cheol;Choi, Jin-Woo
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.5
    • /
    • pp.148-159
    • /
    • 2012
  • The purpose of this study is to validate the effect of improvement such measures as fence installation or planting of bush and herbaceous plants taken from Pinus densiflora forest in Solbat Neighborhood Park in Seoul, which was damaged by stamping. The study was conducted in 2005 and 2010 in order to analyze changes in planting types, planting structure of Pinus densiflora forest, soil hardness, cross-sectional structure of soil, and physicochemical characteristics of soil. It was also measured by the growth of the branches and the diameter of Pinus densiflora, comparing before and after the improvement to study the effect of restoring Pinus densiflora forest damaged by stamping. When it comes to a change in planting type, Pinus densiflora forest without underlay was reduced from 48.5% in 2005 to 6.8% in 2010. Pinus densiflora forest with bush and herbaceous plants was increased dramatically from 7.4% to 46.8%. Regarding planting structure, in most area of the subject site, Pinus densiflora forest without under layer was transformed into the one with bush and herbaceous plants including Rhododendron mucronulatum, Rhododendron schippenbachii, Hemerocallis fulva, Aceriphyllum rossii, Hosta plantaginea growing in a wide area. The soil in the Solbat Neighborhood Park was very stiff with soil hardness of $54.8kg/cm^2$ in average. After the improvement efforts made in the Park in 2010, the soil hardness was mostly less than $4kg/cm^2$, being in a good condition with little influence on the growth of plants. When it comes to the cross-sectional structure of soil, litter layer didn't exist in 2005 because of stamping and the organic matter layer was only 1.0cm thick, which provided an unfavorable condition for plant growth. However, after improvement, litter layer was formed up to 3.0cm and thickness of the organic matter layer also went up to 1.5~8.0cm in 2010 because the damage from stamping was reduced. Concerning the physicochemical characteristic of soil, in 2005 soil showed pH 5.76~6.70, organic matter content 7.15~10.55%, and available phosphorus 9.38~26.47mg/kg, having no big problems as a soil environment for growth of Pinus densiflora. 15 trees of Pinus densiflora were selected to see branch growth and it was found that the branches tended to grow better after improvement. 70 trees of Pinus densiflora from various grades of soil hardness also were selected to identify changes of diameter growth. In most cases, it was analyzed that Pinus densiflora grew better after improvement. After conducting this study, it was validated that such measures as fence installation or planting of bush and herbaceous plants to restore Pinus densiflora Forest damaged by stamping were effective in improving growth of Pinus densiflora.

The Effect of Adequate Radiation Shield Production for Radiation Worker (방사선 차폐체 제작을 통한 작업종사자 피폭 감소 방안)

  • Kim, Ki;Hong, Gun-Chul;Kwak, In-Suk;Park, Sun-Myung;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.41-44
    • /
    • 2010
  • Purpose: Along with recent advances in PET/CT instrumentation and imaging technology, the number of patients has also been steadily increasing. This resulted in the increased radiation exposure to radiation workers in PET/CT rooms. In this study, we installed a radiation shield and investigated whether it could reduce radiation exposure to the workers and thus enhance job satisfaction. Materials and Methods: A radiation shield is composed of 5 cm thick lead and has a structure in which a radiation worker sits and watches a patient through lead glass while injecting radiopharmaceutical to the patient. Quarterly absorbed dose of radiation workers was measured using thermoluminescence dosimeters (TLD) and the results were compared for six months each before and after installation of the radiation shield. Exposure dose was also measured using a pocket dosimeter placed at the same location in the front and the back of the radiation shield. In addition, frequency of use of the shield and job satisfaction of radiation workers were investigated using a survey. Results: Quarterly absorbed dose of radiation workers was 2.70 mSv on average before installation of new radiation shield, whereas that dropped to 2.13 mSv after installation of radiation shield, reducing radiation exposure dose by 21%. Exposure dose on the front side of the shield was 61.2 R, whereas that on the back side of shield was 2.8 R. According to the survey, 85% of workers used the shield and were satisfied with the outcome: each radiation worker made injections to patients average of 6.5 times/day and preferred sitting to standing while injecting radiopharmaceutical to patients. Conclusion: Use of radiation shield reduced the exposure dose of radiation workers, which is the ultimate goal of radiation protection to minimize radiation exposure and is an appropriate method for the improvement of hospital working environment. Furthermore, we found that use of radiation shield not only relieves physical and psychological burden of radiation workers but also enhances job satisfaction. This result indicates that use of radiation shield is important for improvement of the radiation workers' job environment in terms of radiation protection.

  • PDF

Effect of Warm Curtain Installation on Growth Performance, Blood Hormone Levels and Immunity of Weaning Pigs (보온막 설치가 이유자돈의 생산성 및 혈중 호르몬과 면역성분의 농도에 미치는 영향)

  • Kim, Y.H.;Lee, S.D.;Kim, D.H.;Jeong, H.J.;Kim, D.W.;Cho, K.H.;Sa, S.J.;Hur, T.Y.;Kim, S.H.;Kim, I.C.
    • Journal of Animal Environmental Science
    • /
    • v.17 no.2
    • /
    • pp.115-122
    • /
    • 2011
  • This study was conducted to investigate the changes in growth performance, blood hormone levels and immunity of weaning pigs by the installation of warm curtain for keeping warmth in pigpen. A total of sixty-four piglets was weaned at 21 d of age with an average body weight of 5.8 kg. Each thirty-two piglets were allocated into the pens with (TRT) or without warm curtain (CONT). Daily gain and feed intake were increased by 17% and 9% in TRT from 2nd week to 4th week compared with CONT, respectively. The occurrence of diarrhea was decreased by 62% in TRT from initial to 2nd week compared with CONT. There were no significant differences in blood hormone levels and immunity of weaning pigs between treatments. In conclusion, the installation of warm curtain, which supported high temperature in pigpen, was considered to be effective in improving growth performance and reducing diarrhea occurrence of weaning pigs.

Application of Low Pressure Fogging System for Commercial Tomato Greenhouse Cooling (상업용 토마토온실 냉방을 위한 저압분무식 포그시스템의 적용)

  • Lee, Hyun-Woo;Kim, Young-Shik
    • Journal of Bio-Environment Control
    • /
    • v.20 no.1
    • /
    • pp.1-7
    • /
    • 2011
  • The objective of the present study is to identify the applicability of a low pressure fogging system for cooling commercial tomato greenhouse. In particular, the cooling system in this experiment utilizes low pressure spray nozzles which were developed in Korea recently. The experimental result that the temperature in fog-cooled greenhouse was lower than the non-cooled greenhouse showed the cooling effect by the low pressure fogging system. But because the relative humidity in fog-cooled greenhouse was comparatively low, the satisfactory cooling effect could be acquired by narrowing the space of fog nozzles and extending fogging time to supply more fog spray quantity. The variation of temperature distribution in fog-cooled greenhouse along timelag was insignificant during short time, but that was great during long period of day. This result showed the variation of temperature along timelag was slight by fog cooling but great by other factors like radiation, ventilation, air flow, etc. The advanced operation technology of fog system was required to reduce the variation of temperature along time lag. We plan to suggest the advanced installation and operation technology of low pressure fogging system for cooling commercial tomato greenhouse by further experiments in near future.

Characteristic of Oviposition and Effect of Density Suppression by Yellow-colored Sticky Trap on Ricania shantungensis (Hemiptera: Ricaniidae) in Blueberry (블루베리에서 갈색날개매미충의 산란특성 및 황색끈끈이트랩의 산란 억제효과)

  • Kim, Dong Hwan;Kim, Hyeong Hwan;Yang, Chang Yeol;Kang, Taek Jun;Yoon, Jung Beom;Seo, Mi Hye
    • The Korean Journal of Pesticide Science
    • /
    • v.20 no.4
    • /
    • pp.281-285
    • /
    • 2016
  • This study was conducted to investigate the characteristics of oviposition and the effect of density suppression by yellow-colored sticky trap on Ricania shantungensis in blueberry. The occurrence of an egg mass of R. shantungensis in the upper, middle and lower region were 56.6~60.2%, 23.8~28.1% and 11.7~19.7%, respectively. The number of egg masses in the branch was investigated. Percentage of the branch with one egg mass was greatest (50.9%) than with two (20.5%), three (14.6%) and over four (14.0%). The effect of yellow-colored sticky trap to reduce the number of R. shantungensis egg masses in blueberry was also investigated. In a month after yellow sticky trap installation, 17.1 adults of R. shantungensis were attracted per trap. Moreover, the number of egg masses on a tree in yellow-colored sticky trap plot was much lower (0.4) than control (1.3). Consequently, this result shows that use of yellow-colored sticky trap may contribute to decrease ovipisotion rate of R. shantungensis in blueberry.

An analysis study for reasonable installation of tunnel fire safety facility (터널 방재설비의 합리적 설치를 위한 분석적 연구)

  • Park, Jin-Ouk;Yoo, Yong-Ho;Park, Byoung-Jik
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.3
    • /
    • pp.243-248
    • /
    • 2015
  • Domestic road and railroad construction have been increasingly growing and for reasons of mitigating traffic congestion, urban plan and refurbishment project, deeper and longer tunnels have been built. The event of fire is the most fatal accident in a tunnel, and it can be very disastrous with a high possibility. In this study, QRA (Quantitative Risk Analysis) which is one of quantitative risk analysis approaches was applied to tunnel fire safety design and the evaluation of QRA cases and the cost comparison of QRA methods were carried out. In addition analysis of risk reduction effect of tunnel fire safety system was conducted using AHP (Analytic Hierarchy Process) and the priority of major factors that could mitigate the risk in tunnel fire was presented. As a result, significant cost reduction effect could be obtained by incorporating QRA and it is expected to design fire safety system rationally. The priority of fire safety system based on risk mitigation effect by fire safety system considering the cost is in order of water pipe, emergency lighting, evacuation passage and smoke control system.

A Study for the Water Rising Effect on Flood Water Level by Debris (유송잡물에 의한 홍수위 상승 영향분석 - 삽교천의 선우대교를 중심으로 -)

  • Cho, Yong-Ho;Jeong, Sang-Man;Han, Kyu-Ha;Shin, Kwang-Seob
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.7 no.5
    • /
    • pp.179-186
    • /
    • 2007
  • This paper has investigated a rise of water level in upstream and downstream of bridge, which is caused by accumulation of debris in a bridge. The debris has been classified into several types in terms of size. The rise of water level which has been caused by installation and removal of sheet pile that is used to block water in a bridge has been analyzed using HEC-RAS model. According to the analysis, it has turned out that the debris has no influence on the rise of water level in ordinary water flow. In addition, sheet pile has little impact on the rise of water as well. Even though the impact of sheet file has turned out trivial in flood flow just like the ordinary water flow, it's been simulated that the maximum water level difference between upstream and downstream of bridge turned out more than 1.0meter because of debris in 80-year or more flood frequency. When the rise of water level in upstream from the cross section of the bridge was investigated based on 100-year flood frequency, besides, it has turned out that it had an influence up to 17.84km distance because of the effect of debris.

Development Length of GFRP Rebars Based on Pullout Test (인발실험에 의한 GFRP 보강근의 정착길이 제안)

  • Choi, Dong-Uk;Ha, Sang-Su;Lee, Chang-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.3
    • /
    • pp.323-331
    • /
    • 2007
  • The development length equations of the GFRP rebars are suggested based on the pullout tests performed in this study. A total of 48 pullout and modified pullout tests were completed. Test variables included embedment length (L=10, 15, 20, and $30d_b$), vertical and horizontal installation of the rebars, height of the rebars (H=100 and 300 mm), and cover thickness $(C=2{\sim}5d_b)$. D13 GFRP rebars domestically developed were used in the experimental program. The average of the bond strength of all vertically installed GFRP rebars was 6.39 MPa with a 5% fractile of 4.63 MPa. A basic development length equation was derived that resulted in an equation equivalent to the one proposed in the ACI 440.1R-03. Careful reevaluation of the bond strength using the modified pullout test indicated that a modification of the design equation was necessary so that the basic development length increases by 11%. The top bar effect of the horizontally installed rebars as well as the effect of the cover thickness were determined and included in the set of suggested equations. Since the current equations were derived from testing rebars embedded in relatively low strength concrete $(f_{ck}=20{\sim}24MPa)$, they result in conservative development lengths when applied to bars embedded in higher strength concretes.

A Study on the accuracy of speed measuring system by the Doppler effect -The error of speed single beam Doppler log over the ground by various trim- (Doppler 효과(效果)에 의한 속도계측장치(速力計測裝置)의 정도(精度)에 관(關)한 연구(硏究) -Single beam Doppler log의 트림 변화에 따른 대지속력(對地速力) 오차(誤差)-)

  • Kim, Koang-Hong
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.9 no.2
    • /
    • pp.179-187
    • /
    • 1997
  • Doppler log and current meter are based on the measurment of the doppler effect. Ship's speed over the ground measured by means of doppler log effect of underwater ultrasonic intends to get infulence by the difference of sound velocity, the ship's course, the sea bottom inclination, the trim and tranducer installation etc. This paper investigated on the error of speed over the ground by change of the trim comparing the real speed obtained by the mile post with the speed of single beam type doppler log on the trainning ship Kyeongyangho. The results are as follows ; 1. Indicating speed of doppler log is very much greatly influenced on variation of trim, but the real speed is less affected variation by trim. 2. The range of variation and error of speed over ground are smallest when ship's trim is 2.15m trim by the stern.

  • PDF

Cable vibration control with internal and external dampers: Theoretical analysis and field test validation

  • Di, Fangdian;Sun, Limin;Chen, Lin
    • Smart Structures and Systems
    • /
    • v.26 no.5
    • /
    • pp.575-589
    • /
    • 2020
  • For vibration control of stay cables in cable-stayed bridges, viscous dampers are frequently used, and they are regularly installed between the cable and the bridge deck. In practice, neoprene rubber bushings (or of other types) are also widely installed inside the cable guide pipe, mainly for reducing the bending stresses of the cable near its anchorages. Therefore, it is important to understand the effect of the bushings on the performance of the external damper. Besides, for long cables, external dampers installed at a single position near a cable end can no longer provide enough damping due to the sag effect and the limited installation distance. It is thus of interest to improve cable damping by additionally installing dampers inside the guide pipe. This paper hence studies the combined effects of an external damper and an internal damper (which can also model the bushings) on a stay cable. The internal damper is assumed to be a High Damping Rubber (HDR) damper, and the external damper is considered to be a viscous damper with intrinsic stiffness, and the cable sag is also considered. Both the cases when the two dampers are installed close to one cable end and respectively close to the two cable ends are studied. Asymptotic design formulas are derived for both cases considering that the dampers are close to the cable ends. It is shown that when the two dampers are placed close to different cable ends, their combined damping effects are approximately the sum of their separate contributions, regardless of small cable sag and damper intrinsic stiffness. When the two dampers are installed close to the same end, maximum damping that can be achieved by the external damper is generally degraded, regardless of properties of the HDR damper. Field tests on an existing cable-stayed bridge have further validated the influence of the internal damper on the performance of the external damper. The results suggest that the HDR is optimally placed in the guide pipe of the cable-pylon anchorage when installing viscous dampers at one position is insufficient. When an HDR damper or the bushing has to be installed near the external damper, their combined damping effects need to be evaluated using the presented methods.