• 제목/요약/키워드: Instability Condition

검색결과 505건 처리시간 0.024초

구조물 모니터링을 위한 헤테로 코어형 광센싱 시스템 (Hetero-core Spliced Fiber Optical Sensing System for an Environment Monitoring)

  • 김영복;이권순;와타나베카즈히로;사사키히로유키;최용운
    • 한국해양공학회지
    • /
    • 제21권3호
    • /
    • pp.46-51
    • /
    • 2007
  • A multi-purpose environmental monitoring system has been developed as a commercially available standard using the technique of hetero-core spliced fiber optic sensors, for the purposes of monitoring large-scale structures and preserving natural environments. The monitoring system has been tested and evaluated in a possible outdoor condition, in view of the full-scale operation at actual sites to be monitored. Additionally, the developed system in this work conveniently provides us with various options of sensor modules intended for monitoring such physical quantities as displacement, distortion, pressure, binary states, and liquid adhesion. Two channels of optical fiber line were monitored in each channel, three displacement sensor modules were connected in series, in order to examine the performance to a pseudo-cracking experiment in the outdoor situation and to clarify temperature influences an the system, in terms of the coupling of optical connectors and the OTDR stability. The results from the pseudo-cracking experiment agreed with the actual cracks, by means of calculation, based an the detected displacement values and their geometrical arrangement of the used sensor modules. The temperature change, ranging from 10 to $20^{\circ}C$ resulting from the 10-days free running operation, was found to influence the system stability of ${\pm}10{\mu}m$, primarily due to the coupling instability of the used optical connectors. It was found that fusion splicing, rather than the use of connectors, reduced the fluctuation dawn to ${\pm}2{\mu}m$. The specification and performance of various option modules have been demonstrated to show the capability of inspecting various physical quantities by use of the single system, which would be suitable for multi-purpose environmental monitoring.

단단 주 급수 펌프 임펠러에서 시운전 중 발생한 피로 절손에 관한 규명 연구 (Identification on Fatigue Failure of Impeller at Single Stage Feedwater Pumps During Commissioning Operation)

  • 김연환;김계연;배춘희;이영신
    • 한국소음진동공학회논문집
    • /
    • 제18권9호
    • /
    • pp.937-942
    • /
    • 2008
  • 이 논문은 건설이 완료된 700MW급 발전소의 시운전 기간 중 주 급수펌프 임펠러에서 반복적으로 발생된 웨어링 이탈 및 고착, 슈라우드 손상 그리고 축 절단 등의 절손이 부분부하 조건에서 증폭되는 압력맥동과 연관이 있는 것으로 규명되었다.

한국형 기동헬기 전기체 지상진동시험 (Ground Vibration Test for Korean Utility Helicopter)

  • 김세희;곽동일;정세운;최종호;김정훈
    • 한국항공우주학회지
    • /
    • 제41권6호
    • /
    • pp.495-501
    • /
    • 2013
  • 한국형 기동헬기는 블레이드 가진주파수를 회피하고 지상 운용에서 로터와 기체의 동적 특성이 연계되어 나타나는 불안정성이 없도록 설계되었다. 이러한 설계 목적을 위해 진동 해석과 지상공진 해석을 수행하여 기체와 주로터의 동적 특성을 분석하였다. 이후 훨타워 시험을 통해 주로터의 동적특성을 확인하였으며 지상진동시험을 통해 기체의 동적 특성을 확인하였다. 지상진동시험은 지상 및 비행 운용 조건이 고려된 시험체 구성과 시험 조건을 적용하여 수행되었다. 본 논문에서는 한국형 기동헬기에 적용된 지상진동시험 방법 및 분석 기법을 보이고 해석 모델 보정기법과 보정된 해석 결과를 제시한다.

플라즈마 후처리 시간에 따른 저유전율 SiOF 박막의 특성 (Characteristics of Low Dielectric Constant SiOF Thin Films with Post Plasma Treatment Time)

  • 이석형;박종완
    • 한국진공학회지
    • /
    • 제7권3호
    • /
    • pp.167-272
    • /
    • 1998
  • ECR plasma CVD를 이용한 SiOF박막은 낮은 유전상수를 가지고 있으며, 기존의 공정과의 정합성이 우수해 다층배선 공정에 채용이 유망한 재료이지만 수분의 흡수로 인한 유전율의 상승과 후속공정의 안정성이 문제점으로 부각되고 있다. 따라서 본 연구에서는 SiOF박막의 내흡습성과 후속공정에서의 안정성을 향상시키기 위하여 SiOF박막을 증착한 후 후속 산소 플라즈마 처리를 행하였다. SiOF박막은 산소 플라즈마 처리를 수행함으로써 SiOF박막의 밀도가 증가하고, 수분과의 친화력이 강한 Si-F 결합이 감소하는 것이 주요한 원인으로 사료된다. 하지만 플라즈마 처리 시간이 5분 이상으로 증가하면 유전율의 증가가 일어난다. 따라서 본 실험에서는 산소 플라즈마 처리조건이 마이크로파 전력이 700W, 공정 압력이 3mTorr, 기판온도가 $300^{\circ}C$일 경우 플라즈마 처리시간은 3분이 적당한 것으로 생각 된다.

  • PDF

디젤 엔진 차량의 무급유 터보차져의 성능 평가에 관한 연구 (A Study on the Characteristics of the Oil-free Turbocharger for Diesel Engine Vehicles)

  • 박동진;김창호;이용복
    • 한국자동차공학회논문집
    • /
    • 제16권4호
    • /
    • pp.47-55
    • /
    • 2008
  • Turbocharger has a main purpose on recycling of the exhaust gas from the engine cylinder. On the basis of the facility characteristics, the turbocharger supported on floating ring bearings has some problems such as the large volume, oil supplement for lubrication and high power loss due to high operating torque. The air foil bearing has been studied as the bearing element to be able to alternate the floating ring bearing without the problems of the floating ring bearing. In this study, the air foil bearing has 2 parts; journal and thrust bearings, and the test facility consists of the engine, exhaust and intake parts. In addiction, the specification of the turbocharger follows a small turbocharger for SUV engine. The engine speed is varied from 750 (idle rpm) to 2,500 rpm and then, the rotating speed of the turbocharger rotor is accelerated from 0 to 100,000 rpm. From those experiments, the comparison between the performances of the air foil bearing and floating ring bearing is conducted and the results show that the air foil bearing has less power loss, maximum 770 watt, than the floating ring bearing, maximum 5,110 watt. This result verifies that the air foil bearing is more efficient and able to output more power under the same condition of the input power.

$SiO_x(x{\le}2)$ 플레이트의 표면 결함 분포가 화학 소염에 미치는 영향 (Effects of Surface Defect Distribution of $SiO_x(x{\le}2)$ Plates on Chemical Quenching)

  • 김규태;권세진
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2005년도 제31회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.328-336
    • /
    • 2005
  • Effects of surface defect distribution on flame instability during flame-surface interaction are experimentally investigated. To examine the chemical quenching phenomenon, we prepared thermally grown silicon oxide plates with well-defined defect density. Ion implantation was used to control the number of defects, i.e. oxygen vacancies. In an attempt to preferentially remove the oxygen atoms from silicon dioxide surface, argon ions with low energy level from 3keV to 5keV were irradiated at the incident angle of $60^{\circ}C$. Compositional and structural modification of $SiO_2$ induced by low-energy $Ar^+$ ion irradiation has been characterized by Atomic Force Microscopy (AFM) and X-ray Photoelectron Spectroscopy (XPS). The analysis shows that as the ion energy increases, the number of structural defect also increases and non-stoichiometric condition of $SiO_x(x{\le}2)$ plates is enhanced. From the quenching distance measurements, we found out that when the surface temperature is under $300^{\circ}C$, the quenching distance decreases on account of reduced heat loss; as the surface temperature increases over $300^{\circ}C$, however, quenching distance increases despite reduced heat loss effect. Such aberrant behavior is caused by heterogeneous chemical reaction between active radicals and surface defect sites. The higher defect density, the larger quenching distance. This results means that chemical quenching is governed by radical adsorption and can be parameterized by the oxygen vacancy density on the surface.

  • PDF

뇌-컴퓨터-인터페이스를 이용한 암환자들의 전전두엽 뇌파 분석 (Patterns Analysis of Prefrontal Brain Waves of Cancer Patients using Brain-Computer-Interface)

  • 한영수;채명신;박병운;박종기
    • 한국정보과학회논문지:소프트웨어및응용
    • /
    • 제35권3호
    • /
    • pp.169-178
    • /
    • 2008
  • 암환자들은 암의 진행과 항암화학요법 등의 치료로 인해 심신의 불안정과 항상성의 저하로 큰 고통을 겪고 있다. 간편하면서 인체에 아무 해를 주지 않는 뇌파를 기반으로 하는 뇌-컴퓨터-인터페이스(BCI) 기술로서 암 환자의 상태를 모니터링하여 적절한 처치를 취할 수 있다는 것은 매우 중요한 일이다. 암환자들의 전전두엽에 헤드밴드 형태의 건성전극단자를 부착하고, 컴퓨터와 연결된 휴대용 뇌파측정 장치로 전전두엽 뇌파(Fp1, Fp2)를 측정하였다. 컴퓨터를 통하여 파장대 별로 얻어진 뇌파를 상호 연관성에 따라 뇌지수로 구분한 후 통계 처리하여 유의성을 검증하였다. 암환자군과 정상대조군을 비교한 결과 암환자군에 비하여 정상대조군이 기초율동지수, 주의지수, 정서지수, 항스트레지수와 좌우뇌균형지수에서 유의하게 높은 차이를 나타냈다. 따라서 뇌파 측정이 환자의 상태를 모니터링하는 중요한 도구로서의 가능성을 보였다.

견관절의 임상적 평가도구에 관한 고찰 (A Review of Clinical Shoulder Assessment Scales)

  • 양동훈;김건형;김행범;최양식;박영배
    • Journal of Acupuncture Research
    • /
    • 제24권6호
    • /
    • pp.123-135
    • /
    • 2007
  • Objectives : A number of instruments have been developed to measure the quality of life in patients with various shoulder disorders. Much progress has been made in this area, and currently an appropriate instrument exists for each shoulder state. The purpose of this study is to review the instruments that are currently in use for assessing the shoulder joint. Methods : A literature research was performed to choose appropriate scales for assessment of function and the disability of the shoulder. Theoretically based scales were selected for review. Therefore, 11 scales were reviewed. The status of scales involved in shoulder treatment of acupuncture throughout several countries was evaluated. Results : 11 scales: The American shoulder and elbow surgeons evaluation form(ASES), Constant Shoulder Score, The disabilities of the arm, shoulder and hand(DASH), Shoulder Disability Questionnaire (SDQ), The Shoulder Pain And Disability index(SPADI), The simple shoulder test(SST), Oxford Shoulder Questionnaire(OSQ), The Rotator Cuff quality-of-life Measure(RC-QoL), Western Ontario Shoulder Instability Index(WOSI), Western Ontario Osteoarthritis of the Shoulder Index(WOOS), Western Ontario Rotator Cuff Index(WORC), wereevaluated. Each measurement has its own composition and characteristics. Their validity, reliability, responsiveness and practical characteristics were already evaluated. We found 3 domestic and 10 overseas papers about shoulder treatments using acupuncture assessed with shoulder scales. Conclusions : In clinical research, the selection of the measurement scale should take account of the condition of disease, the patient's traits and the characteristics of the research. Moreover, appropriate scales, which havevalidity, reliability, responsiveness and practical characteristics, are needed to enhance the quality of research.

  • PDF

Numerical Analysis of the Influence of Acceleration on Cavitation Instabilities that arise in Cascade

  • Iga, Yuka;Konno, Tasuku
    • International Journal of Fluid Machinery and Systems
    • /
    • 제5권1호
    • /
    • pp.1-9
    • /
    • 2012
  • In the turbopump inducer of a liquid propellant rocket engine, cavitation is affected by acceleration that occurs during an actual launch sequence. Since cavitation instabilities such as rotating cavitations and cavitation surges are suppressed during launch, it is difficult to obtain data on the influence of acceleration on cavitation instabilities. Therefore, as a fundamental investigation, in the present study, a three-blade cyclic cascade is simulated numerically in order to investigate the influence of acceleration on time-averaged and unsteady characteristics of cavitation that arise in cascade. Several cases of acceleration in the axial direction of the cascade, including accelerations in the upstream and downstream directions, are considered. The numerical results reveal that cavity volume is suppressed in low cavitation number condition and cavitation performance increases as a result of high acceleration in the axial-downstream direction, also, the inverse tendency is observed in the axial-upstream acceleration. Then, the regions in which the individual cavitation instabilities occur shift slightly to a low-cavitation-number region as the acceleration increases downstream. In addition, in a downstream acceleration field, neither sub-synchronous rotating cavitation nor rotating-stall cavitation are observed. On the other hand, rotating-stall cavitation occurs in a relatively higher-cavitation-number region in an upstream acceleration field. Then, acceleration downstream is robust against cavitation instabilities, whereas cavitation instabilities easily occur in the case of acceleration upstream. Additionally, comparison with the Froude number under the actual launch conditions of a Japanese liquid propellant rocket reveals that the cavitation performance will not be affected by the acceleration under the current launch conditions.

강우침투실험을 통한 불포화 풍화토 지반의 강우 침투속도 분석 (Analysis of Seepage Velocity in Unsaturated Weathered Soils Using Rainfall Infiltration Test)

  • 김훈;신호성;김윤태;박덕근;민덕기
    • 한국지반공학회논문집
    • /
    • 제28권2호
    • /
    • pp.71-78
    • /
    • 2012
  • 본 연구에서는 실내 강우침투실험을 통하여 강우강도에 따른 지반 내 침투속도를 산정하였으며, 침투특성을 분석하여 보았다. 또한 수치해석을 이용한 해석결과와 비교 검증을 수행하였으며, 시간에 따른 간극수압과 포화도 그리고 유출속도의 변화는 대체로 잘 일치함을 보였다. 강우강도에 따른 침투속도는 실내실험과 수치해석에서 선형적으로 증가하는 경향을 나타냈으며, 강우강도가 지반의 포화투수계수에 근접시 침투속도가 급격히 증가하였다. 또한 강우 침투시 습윤전선의 상부는 부분적으로 포화되어 침투하는 경향을 보였다. 따라서 실제 지반에서 습윤전선은 비교적 빠르게 진행하여 사면의 불안정을 초래할 것으로 판단된다.