• Title/Summary/Keyword: Inspection Equipment

Search Result 651, Processing Time 0.036 seconds

Cost of Ownership Model for the Inspection Equipment of Multiple Quality Attributes (다항목 검사장비를 위한 COO 모형 연구)

  • Sohn, So-Young;Moon, Hyoung-Uk;Hong, Cheol-Kee
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.27 no.3
    • /
    • pp.297-304
    • /
    • 2001
  • Procurement decisions for inspection equipment are often made heavily based on the initial purchase price instead of the effects of inspection cost, equipment calibration and utilization over the lifetime. Cost of ownership(COO) models that take into account all of these cost factors together have been developed focusing on a single quality characteristic. In modern manufacturing environment, inspection equipment often can deal with more than one quality characteristic simultaneously. In this paper, we propose the revised COO model for the economic evaluation of the inspection equipment that can accommodate multiple quality characteristics. We also employ an engineering economy model to compare equipments with different life span. Software is developed for handy comparison of the COO of alternative equipments along with sensitivity analysis far the optimal procurement decision.

  • PDF

A report on the preparation of signaling equipment procedures for the periodic inspection (신호설비 정기검사 절차서 작성에 대한 보고)

  • Ko, Yang-Ok;Seo, Moon-Seog
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.623-629
    • /
    • 2008
  • A periodic inspection for facilities in operation is an inspection that is carried out regularly, in which inspection cycles are drawn up, and it is a series of tests to determine if the condition of all the equipment is maintained, and to identify whether they are to be used or replaced. Reliability should be enhanced, without a breakdown, by preliminary inspection and regular checks for each equipment item installed for equipment maintenance. It was noticed that there was a slight difference for the same facility, and for each organization in terms of inspection cycles and methods while preparing procedures of periodic inspection checklist, inspection methods and cycles for a related organization. Therefore, this paper reviews the optimal methods of inspection procedures for Seoul Metro.

  • PDF

Study on the Optical Analysis Equipment Control System for Electronic Parts Inspection (전자 부품 검사용 광학분석 장비 제어시스템에 대한 연구)

  • Lee, Jun Ha
    • Journal of the Semiconductor & Display Technology
    • /
    • v.14 no.4
    • /
    • pp.67-71
    • /
    • 2015
  • Product of technology developed in this study is an external interface for controlling the equipment of pendant key remote control system circuit board, and it is used in the electronic component test equipment system. Main control system module is in the role as a device for controlling the various control devices that make up the integrated system for microscopic examination at the request of the host computer engineers to control the inspection equipment. The pentane-key interface module to its role as a device for controlling the various control devices that make up the integrated system for microscopic examination at the request of the host computer for the engineer to control the inspection equipment. Development of the control system can be expected in the configuration of a system for efficient and accurate inspection of high-precision parts.

Development of Viscous Inspection Equipment by Moire Phenomenon for Flatron Panel Glass

  • Chung, Kyu-Chul
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.118-121
    • /
    • 2002
  • In this study, we describe the development of viscous inspection equipment for flatron panel glass by Moire phenomenon and propose a new idea to develop an automatic inspection system for viscous or cord defects. It is possible to detect string viscous more easily and the equipment is practically being applied in production line. After using this equipment, the ratio of defective from customer is dropped significantly.

  • PDF

Amendment of the Inspection Standard for Diagnostic Radiation Equipment Applying IEC 60601-1-3: Medical Electrical Equipment - Part 1-3: General Requirements for Basic Safety and Essential Performance - Collateral Standard: Radiation Protection in Diagnostic X-ray Equipment (KS C IEC60601-1-3: 의료용 전기기기-제1-3부: 기본 안전 및 필수 성능에 관한 일반 요구사항-보조표준: 진단용 X선 장치의 방사선 방어를 적용한 진단용 방사선 발생장치의 검사기준 개선안)

  • Park, Hye-Min;Kim, Jung-Min;Kim, Jung-Su;Kim, Seong-Ok;Choi, Young-Min
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.493-504
    • /
    • 2018
  • The diagnostic radiation equipment is managed in accordance with the "Rules for Safety Management of Diagnostic Radiation Equipment" enacted in 1995. The equipments should be inspected before use and every three years after use in accordance with the [Appendix 1] of the same rule. The inspection standard has been maintained without particular revision since enacted. But, over the past two decades new types of equipments have been manufactured and used. So, it is necessary to revise [Appendix 1] by making inspection items and inspection standards. In this study, we revised the classification system of equipments and reviewed international standards of IEC 60601 series, IEC 61223 series and AAPM TG 18 On-line Report No.03. And identified the problem of current inspection standards. Through this, we revised, deleted and added the inspection items and inspection standard of each equipment to meet the domestic circumstances. As a result of the study, we reorganized the classification system of equipment which are current classified as 5 classes into 22 classes as X-ray system etc. (7 classes), CT system etc. (5 classes) and Dental X-ray system etc. (10 classes). And then, we developed 70 inspection items for 6 types of equipments according to the reorganized classification system of equipments. The inspection items and inspection standards derived from this study have been proposed to the KCDC and will be applied to the revision of the Rule's [Appendix 1]. Therefore, we expect to be used as reference materials for domestic medical center, inspection institutions, and equipment manufacturing import companies.

Research on Foundation Technology for Crack Inspection Automation Device with Effective Performance (효과적인 크랙 검사 자동화 장치를 위한 기반 기술 연구)

  • Choi, Goon-Ho
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.4
    • /
    • pp.143-148
    • /
    • 2019
  • Numerous pipe lines can be found on various plant-based industrial sites. These pipelines should be periodically checked for defects. Most of these pipelines are internally inaccessible and difficult to visually inspect. Therefore, the inspection is being carried out with the help of non-contact inspection equipment such as ultrasonic flaw detection equipment. The use of ultrasonic flaw detection equipment can raise time and efficiency issues. In order to solve this problem, we will study the basic technology necessary for the development of automated inspection system equipped with ultrasonic measuring equipment and verify the validity through the fabrication of the demonstration device.

A study on Optimum Inspection Policy for an equipment with two stages of failures (이단계 고장을 갖는 설비에 대한 최적 검사 정책)

  • 김정식
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.13 no.21
    • /
    • pp.19-24
    • /
    • 1990
  • This paper deals with a problem of choosing an optimum inspection period for an equipment with two stages of failures. Stage I failure which can be detected only through inspection detenorates the equipment and causes critical stage II failure after a random period of time. The expected average cost function is obtained and an optimum inspection policy is discussed. A numerical example is also worked out.

  • PDF

Basic research, according to the inspection of crane equipment (크레인 설비의 검사에 따른 기초연구)

  • An, Tae-Keon;Shim, Kyu-Hyung;Rie, Dong-Ho
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.4
    • /
    • pp.169-175
    • /
    • 2012
  • Self-Inspection is being used in the workplace hazardous, dangerous machinery and equipment to build capacity for the voluntary safety risks due to use of machinery and prevention of industrial accidents that inspect facilities for safety issues, is to check. However, December 31, 2008 as part of Article 36 of the Occupational Safety and Health Act (safety inspection), the financial vanish as the self-test, Safety inspection program has been changed., In each individual workplace that creates its own standards and regulations to use the existing inspection system is in some cases. This study is located in the southeast industrial complex as a risk reducer manufacturer, machine-based target zones in S Corp owns most of the crane based on the results of the tests is to analyze the problem. Then check the results - to bring its measures and information you need to know for sure is to propose.

Analysis of Safety and Performance Vulnerabilities Using Heat-Using Equipment(Industrial Boiler) Inspection Results (열사용기자재 검사대상기기(산업용 보일러) 검사결과를 활용한 안전 및 성능 취약점 분석)

  • Kim, Hyung-Jun;Oh, Choong-Hyeon
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.4
    • /
    • pp.18-26
    • /
    • 2022
  • The Korean government is conducting heat-using equipment(industrial boiler) inspection in accordance with the Energy Use Rationalization Act because of the heat-using equipment(industrial boiler)'s risks such as explosion and fire, and safe use and management. This paper aimed to setup the safe and performance vulnerabilities from database based on the inspection results for heat-using equipment(industrial boiler). This study surveyed the inspection results of 1,249 heat-using equipment(industrial boiler) which were failed inspection of heat-using equipment(industrial boiler) from january 2016 to december 2020. And the analysis method is to inform safety and performance vulnerability categories of heat-using equipment(industrial boiler) by statistically analyzing the failure reasons of boiler type and inspection type which are high variance in failure rate. The safety and performance vulnerability categories was abbreviated into 18 cases. And each catagory's main reason for failure was suggested by additional analyzing the opinions of inspectors. This paper would be the basic source and the comprehensive information dealing with the safety and performance vulnerability of heat-using equipment(industrial boiler).