• Title/Summary/Keyword: Insole

Search Result 186, Processing Time 0.023 seconds

Medial Longitudinal Arch Balanced Analysis of the Calibration (종족궁 내측아치 지지에 따른 균형능력 분석)

  • Kim, Seonchil;Lim, Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.2
    • /
    • pp.51-56
    • /
    • 2014
  • We analyzed how insole affects the dynamic stability and the balance while a body moves or stops. Specially we've sorted out variations of individual balance ability while we make a longitudinal arch stop artificially as a usual situation(just standing and putting one's weight). We found ten men and girls each with suitable feet for our experimentation as the subject of investigation and made individual insole for them by measuring medial longitudinal arch. Then we compared before and after movement of the power point of application and a pattern of COP using the Tetrax balance equipment. We found out it is better for balance ability when we wear insoles. It turned out to be helpful for increasing balance ability of body to use insole which supports medial longitudinal arch of longitudinal arch well.

Effects of Functional Insole on Walking in the Elderly (기능적 인솔이 노인의 보행에 미치는 영향)

  • Seo, Dong-Kwon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.280-286
    • /
    • 2019
  • This study verified the difference in biomechanical variation and the pattern of the lower limb between using or not using functional insoles on the gait of elderly people. Ten females subjects were selected (age: 73.2 years, height: 152.1 cm, body mass: 59.4 kg) for testing their gait with using functional insoles and without using functional insoles. The gait motions were captured with the Qualisys system and the gait parameters were calculated with Visual-3D. As a result, the subjects' stride length and swing time were significantly increased (p<.05). Also, the lower limb's extension moment was significantly increased (p<.05) when using the insole. These differences suggest the functional insole used in the experiment increases the subjects' gait stability. However, to generalize the results of this study, it is necessary to accumulate more quantitative data with more subjects. Further studies to examine gait variables and changes of walking patterns need to be conducted by gathering and utilizing the results of those subjects who have used insoles for a long period of time.

Effects of Less Affected Lower Extremity Insole on Balance in Chronic Stroke Patients during Treadmill Walking -A Preliminary Study- (트레드밀 훈련 시 비마비측 하지에 적용한 인솔이 만성 뇌졸중 환자의 균형에 미치는 영향 -예비 연구-)

  • An, Bo-Ra;Woo, Young-Keun;Park, Kyeu-Nam;Kim, Su-Jin
    • PNF and Movement
    • /
    • v.18 no.2
    • /
    • pp.215-222
    • /
    • 2020
  • Purpose: The study investigated the effect on chronic stroke patients' balance of a weight shift to the affected side using an insole on the less affected side during treadmill walking training. Methods: The subjects were 7 patients who had been diagnosed with stroke 6-24 months prior to the study. In each case, an insole was applied on the patient's less affected side during treadmill walking training. Each training session lasted 30 minutes and was undertaken 5 times per week for 4 weeks. Biorescue equipment that measures shifts in center of pressure was used to assess balance ability as measured by the Korea-Berg balance scale (K-BBS) before and after each training intervention. The Wilcoxon signed-rank test was used to evaluate within-group effects. Results: The results revealed statistically significant before and after differences in area, pressure, length, and mean velocity of the balance test and on K-BBS (p < 0.05). Conclusion: In chronic stroke patients, using an insole to adjust the height of the shoe on the less affected side is an effective means of increasing weight-shifting on the paralyzed side during treadmill gait training.

Producing the insoles for flat feet of senior men using 3D systems based on 3D scanning, 3D modeling, and 3D printing (3D 스캐닝, 3D 모델링, 3D 프린팅 기반의 3D 시스템에 의한 시니어 평발용 인솔 제작)

  • Oh, Seol Young;Suh, Dongae
    • The Research Journal of the Costume Culture
    • /
    • v.25 no.3
    • /
    • pp.270-284
    • /
    • 2017
  • This study aimed to create 3D-printed insoles for flat-footed senior men using 3D systems. 3D systems are product-manufacturing systems that use 3-dimensional technologies like 3D scanning, 3D modeling, and 3D printing. This study used a 3D scanner (NexScan2), 3D CAD programs including Rapidform, AutoCAD, SolidWorks, Nauta+ compiling program, and a 3D printer. In order to create insoles for flat-footed senior men, we analyzed horizontal sections of 3D foot scans We selected 20 flat-footed and 20 normal-footed subjects. To make the 3D insole models, we sliced nine lines on the surface of the subjects' 3D foot scans, and plotted 144 points on the lines. We calculated the average of these 3D coordinates, then located this average within the 3D space of the AutoCAD program and created 3D sole models using the loft surface tools of the SolidWorks program. The sole models for flat feet differed from those of normal feet in the depth of the arch at the inner sideline and the big toe line. We placed the normal-footed sole model on a flat-footed sole model, and the combination of the two models resulted in the 3D insole for flat feet. We printed the 3D modeled insole using a 3D printer. The 3D printing material was an acrylic resin similar to rubber. This made the insole model flexible and wearable. This study utilized 3D systems to create 3D insoles for flat-footed seniors and this process can be applied to manufacture other items in the fashion industry as well.

The Effects of Gel-type Insole on Patients with Knee Osteoarthritis during Gait (겔-타입 인솔이 무릎 골관절염 환자의 보행에 미치는 영향)

  • Eun, Seon-Deok;Yu, Yeon-Joo;Shin, Hak-Soo
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.3
    • /
    • pp.181-188
    • /
    • 2007
  • The purpose of this study was to investigate the biomechanical effects of wearing different type of insole shoes on gait characteristics in patients with knee osteoarthritis. Seven patients with knee osteoarthritis (Grade 3 & 4 by Kellgren & Lawrence) were participated in the study. They wore two different type of shoes (with Gel-type Insole: GIS, with Normal insole: NIS) during gait. Three dimensional cinematography and Ground Reaction Force(GRF) data were used to get the maximal value of horizontal distance between the center of pressure in GRF and knee joint center, GRF in mediolateral direction, peak value of GRF in frontal plane, vertical compressive force and adduction moment in knee joint. The results were as follows: The maximal value of horizontal distance between the center of pressure in GRF and knee joint center was smaller in GIS than NIS. The peak value of GRF in mediolateral direction was found in 30% of gait cycle, five subjects wearing GIS showed lower value of peak GRF in mediolateral direction than wearing NIS. The peak value of GRF in frontal plane and vertical compressive force in knee joint did not show any difference between GIS and NIS. The adduction moment in GIS decreased in the late stance of gait and the mean value of the adduction moment in GIS smaller than that in NIS. GIS may help to move quickly knee joint center to the center of pressure in GRF, therefore it may prevent increasing the adduction moment in knee joint.

Convergence Comparison of the Angle Change of Ankle Joint while Walking according to the Heel height of Insole Shoes in 20s males with Flatfoot (평발을 가진 20대 남성이 인솔구두의 굽 높이에 따른 보행 시 발목관절의 각도변화에 대한 융복합적 비교)

  • Seo, Kyo-Chul;Park, Seung-Hwan;Kim, Hyen-Ae
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.12
    • /
    • pp.117-123
    • /
    • 2021
  • The purpose of this study is to convergence comparison the ankle joint angle change during walking of college students in their 20s with flat foot according to the heel height of insole shoes. Qualisys Track Manager Software ver. 2.8 (Qalisys Track Manager) was used for 15 college students. Functional shoes with insoles were manufactured, and the heel heights of the shoes were set to 3cm and 7cm. The subjects wore shoes with two high heels and gaited by attaching a reflex marker to the side of the ankle joint. The angle change of the ankle joint was measured in the gait stance phase. The angle of the ankle joint significantly decreased both heel strike, foot flat, midstance, and toe off to the heel height increased when the subjects with flat feet wore insole shoes. Therefore, it is thought that flat feet should wear low shoes when wearing insoles to reduce the fatigue of the soles and to walk comfortably.

The Influence of Wedged Insoles on Lower Extremity Joints during Gait (경사진 안창이 보행시 하지관절에 미치는 영향)

  • Kwon, Min-Jeong;Choi, Hwa-Soon;Chung, Min-K.;Na, Seok-Hee
    • Journal of the Ergonomics Society of Korea
    • /
    • v.26 no.1
    • /
    • pp.19-27
    • /
    • 2007
  • Despite the widespread use of laterally wedged insoles for patients with knee osteoarthritis and medially wedged insoles for controlling rearfoot pronation, an understanding of the effects of wedged insoles was limited and sometimes controversial. The objective of this study was to evaluate the effect of wedged insoles on the kinematics and kinetics of normal gait. Ten male subjects without history of lower limb disorders were recruited. Each subject performed four gait cycles under each of seven conditions; shod with 5$^{\circ}$, 8$^{\circ}$ and 15$^{\circ}$, 8$^{\circ}$ and 15$^{\circ}$ laterally wedged insoles. In order to determine statistical differences among seven conditions, the measured temporal spatial variables, angular displacements, joint moments, and ground reaction forces were compared with a one-way analysis of variance. Some significant changes induced by wedged insoles were apparent in joint moments and ground reaction forces. The medially wedged insole increased the laterally directed ground reaction force and varus moments at the ankle force and varus moments at the ankle and the knee.

Foot pressure analysis of laterally & medially wedged rearfoot insole in gait (보행 시 발 뒤축 내/외측 경사진 안창의 족부압력 분석)

  • Chae Byeong-Gi;Im Wan-Su;Ryu Tae-Beom;Choi Hwa-Sun;Jeong Min-Geun
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2006.05a
    • /
    • pp.208-213
    • /
    • 2006
  • 경사진 안창은 안창의 경사로 발의 자세를 교정함으로써 하지 통증을 완화시키는 데 사용되는 보조치료기구로 내측 경사진 안창(MWI: medially wedged insole)과 외측 경사진 안창(LWI: laterlly wedged insole)으로 나뉜다. 본 연구는 내/외측 경사진 안창이 족부압력에 미치는 영향을 정량적으로 분석하고자 한다. 분석변수는 압력중심(COP: center of pressure)의 궤적 변화, 발바닥 내 세 개 구획에 상대적으로 작용하는 수직 힘(RVF: relative vertical force) 그리고 여덟 개 해부학적 지점의 압력이다. 경사진 안창의 경사조건은 내/외측 각각 $5^{\circ},\;8^{\circ},\;15^{\circ}$이며, 경사가 없는 안창을 포함해 총 일곱 가지 안창이 실험에 사용되었다. 실험참여자로는 20대 성인 남성 10명이 참여하였다. 실험결과 앞발 누름기에서 MWI와 LWI는 모두 COP를 내측으로 이동시키고 외측 압력을 감소시켰다. 뒤축 접지기에서 MWI는 COP를 내측으로 이동 시키고 내측압력을 증가시키는 반면, LWI는 COP를 외측으로 이동시키고 외측압력을 증가시켰다. 그리고 RVF 분석결과 MWI와 LWI는 모두 앞발 부위 힘의 크기를 감소시켰고, LWI만이 발 뒤축 부위 힘의 크기를 증가시켰다.

  • PDF

Evaluation of Ergonomic Performance of Medical Smart Insoles

  • Yi, Jae-Hoon;Lee, Jin-Wook;Seo, Dong-Kwon
    • Physical Therapy Rehabilitation Science
    • /
    • v.11 no.2
    • /
    • pp.215-223
    • /
    • 2022
  • Objective: This study was to resolve the limitations of the experimental environment and to solve the shortcomings of the method of measuring human gait characteristics using optical measuring instruments. Design: A cross-sectional study. Methods: Fifteen healthy adults without a history of orthopedic surgery on the lower extremities for the past 6 months were participated. They were analyzed gait variables using the smart guide and the 3D image analysis at the same time, and their results were compared. Visual-3D was used to calculate the analysis variables. Results: The reliability and validity of the data according to the two measuring instruments were found to be very high; gait speed(0.85), cycle time(0.99), stride time of both feet(0.98, 0.97) stride legnth of both feet(0.86, 0.88) stride per minute of both feet(0.99, 0.96), foot speed of both feet(0.90, 0.91), step time of both feet(0.77, 0.71), step per minute(0.72, 0.74), stance time of both feet(0.96, 0.97), swing time of both feet(0.93, 0.79), double step time(0.81), initial double step time(0.84) and terminal step time(0.76). Conclusions: In the case of the smart insole, which measures human gait variables using the pressure sensor and inertial sensor inserted in the insole, the reliability and validity of the measured data were found to be very high. It can be used as a device to replace 3D image analysis when measuring pathological gait.

Characterization of Composite Frame for Enhancing Energy Harvesting Function of a Smart Shoes (스마트 슈즈의 에너지 하베스팅 기능향상을 위한 복합재료 프레임 특성평가)

  • Lee, Ho-Seok;Jung, In-Jun;Chang, Seung-Hwan
    • Composites Research
    • /
    • v.34 no.6
    • /
    • pp.400-405
    • /
    • 2021
  • In this study, a composite material frame was designed to increase the energy harvesting efficiency of polyvinylidene fluoride (PVDF) ribbon harvesters which are installed inside smart shoes. In order to minimize the amount of deformation in the load direction of the frame, it was designed using carbon continuous fiber composites and its complex shaped structure was manufactured using a 3D printer. In order to calculate the amount of deformation of the insole and midsole of the shoes under the condition of the load generated during walking, the insole and midsole were modeled using the distributed spring elements. Using finite element analysis, the elongation of ribbon-type harvesters mounted on smart shoes was calculated during walking. It is expected that the predicted elongation of the harvester can be utilized to increase the energy harvesting efficiency of smart shoes.