• 제목/요약/키워드: Inside humidity

검색결과 377건 처리시간 0.022초

더운 환경에서 산업용 각반 착용 시 인체생리반응 (Physiological Responses of Wearing Industrial Gaiters in a Hot Environment)

  • 최정화;박준회
    • 한국의류학회지
    • /
    • 제32권7호
    • /
    • pp.1129-1136
    • /
    • 2008
  • The gaiter is one of the personal protective equipments worn in various industrial sites. This study was performed on humans to investigate the physiological strain of wearing gaiters and to compare control gaiters that are currently on the market and new gaiters that are developed for alleviating heat stress. Experiments were conducted in a climatic chamber of WBGT $30.0\pm0.7^{\circ}C$ under five differed experimental conditions: None, Control A, Control B, New A, New B. The results were as follows. The temperature inside gaiters was significantly lower in both New A and New B than in both Control A and Control B and the difference between news and controls was 1$^{\circ}C$ (p<.01). The humidity inside gaiters in both New A and New B were higher than that in Control A, and lower than that in Control B (p<.01). The outermost surface temperature of the gaiter was the lowest in None and it increased in the following order: New B < New A < Control A < Control B. Mean skin temperature was higher by 0.14$^{\circ}C$ in wearing gaiters than in no gaiters. Skin temperatures in lower body were lower in Control than in New and skin temperature in upper body were higher in Control than in New (p<.01). Local sweat rate, total weight loss and subjective sensations did not show a significant difference according to the gaiters. It was concluded that wearing gaiters affected distribution of skin temperature and local sweat rate.

벽체구성에 따른 목조벽체 내 수분변화에 대한 연구(I) - 실내 실험을 통한 개선 가능성 평가 - (Study on Moisture Variation in Light Frame Wall with Different Wall Assemblies (I) - Evaluation of Improvement with Laboratory Test -)

  • 김세종;이전제
    • Journal of the Korean Wood Science and Technology
    • /
    • 제37권4호
    • /
    • pp.320-329
    • /
    • 2009
  • 본 연구는 경골목조벽체의 구조적 안전성을 위협하고 주거환경을 열악하게 하는 벽체 내 수분축적을 감소시키기 위해 수행되었다. 이를 위해 벽체 구성 요소를 변화시켜 실험을 진행하였다. 벽체 구성요소는 방습지 및 공기층을 추가하였고, 이들의 변화에 따른 수분이동의 변화를 조사하기 위하여 실내외 온습도 차이가 뚜렷한 가혹조건에서 기본벽체와 제안벽체의 비교실험을 진행하였다. 실험결과 실내 측 방습지 추가로 방습성능을 높이는 것은 실내로부터의 수분이동 감소에 효과적으로 나타났지만 두 개의 방습지를 설치하는 경우 과도한 방습 성능이나 부적절한 위치선정으로 벽체의 내부의 상대습도를 높이는 것으로 나타났다. 공기층 추가는 환기 효과에 의해 벽체 내부에서 실외로 수분이동을 야기하였다. 공기층에 의해 실내로부터 벽체 내부로 유입되는 수분이동을 막을 대안을 찾는다면 환기에 의한 벽체 내 수분감소 효과를 극대화 할 수 있을 것으로 기대된다.

가을철 온열환경에 대한 대학생의 적응수준 진단 (Diagnosis of Collegian's Adaptation Level for Autumn Environment)

  • 김양원
    • 한국의류산업학회지
    • /
    • 제1권1호
    • /
    • pp.12-17
    • /
    • 1999
  • The actual clothing conditions were surveyed to diagnose clothing condition of collegians in the view point of adaptation to the thermal environment in fall. Then, clothing climate, physiological responses, and subjective sensation were investigated through wearing trials on human subjects in climatic chamber based on the results from the survey. Factors to evaluate validity of clothing condition were clothing weight, clothing climate, physiological responses of human body, and subjective sensation. Adaptability of this research to thermal environment was compared to the results of Toda's and Duno's of Japan, Chung's results of Korea rural area, and Winslow's clo value. The standard values for wearing trials were values at comfortable zone, such as $32{\pm}1^{\circ}C$ of temperature and $50{\pm}10%$ of humidity inside clothing, $36.5{\sim}37.3^{\circ}C$ of ear temperature and $32.2{\sim}34.3^{\circ}C$ of mean skin temperature. Clothing weight per body surface area was 680.9 $g/m^2$ in male and 526.7 $g/m^2$ in women. Cold resistance ability of collegians was superior to Japanese and American, and similar to rural male in Korea. According to the examination of clothing adaptability with clothing weight from the investigation on physiological responses and the actual clothing conditions survey, following were found. Temperature inside clothing ($29.8{\sim}32.3^{\circ}C$) was normal, and humidity inside clothing (32.2~54.8%) was at comfortable zone. Mean skin temperature was at its comfortable zone. Therefore, 615 $g/m^2$ in male and 525 $g/m^2$ in female were a desirable wearing condition.

  • PDF

Environmental Suitability for Conservation and the Risk Period for Fungal Damage of Wooden Cultural Heritages in Korea

  • Ik-Gyun IM;Gyu-Seong HAN
    • Journal of the Korean Wood Science and Technology
    • /
    • 제51권4호
    • /
    • pp.295-308
    • /
    • 2023
  • This study applied a real-time IoT (Internet of Things) environmental monitoring system to wooden cultural heritages (WCHs) located in suburbs and forests in Korea. It automated the graphs of seasonal Temperature (T) and relative humidity (RH) changes inside the heritage structures and seasonal Performance Index (PI) values. While utilizing line graphs of the existing T and RH change trends and a bar graph expressing the PI values, this study examined the current status of the conservation environment inside the WCHs throughout the year and its diagnosis. Consequently, at higher latitudes, the organic cultural heritage repeatedly experienced large T fluctuations, and the risk of physical and chemical degradation of the materials was greater. However, the RH showed significant seasonal differences, even within the same latitude, indicating that the impact of latitude was not significant. Therefore, the staff in charge must manage RH by considering the surrounding environmental conditions and adjusting the internal environment of the structures. The PI values for the year-round T and RH inside the heritages were confirmed to only be a maximum of approximately 60% of the environmental suitability for conservation throughout the year, depending on the season. The relationship between the germination and growth potential period of xerophilic fungi and the monthly internal temperature and humidity in five heritages located at different latitudes was analyzed. As a result, we could thus determine that four particular months of the year (June-September) represent the periods with the highest risk of damage from xerophilic fungi in the country, regardless of latitude.

습식 인공열화 시 밀랍본 복제품의 제책 부위별 열화특성 (Studies on the Aging Characteristics in Different Parts of Beeswax-treated Duplicates during Humidified Artificial Aging)

  • 최경화;조정혜;강영석;양은정;정혜영
    • 펄프종이기술
    • /
    • 제44권5호
    • /
    • pp.72-79
    • /
    • 2012
  • In this study, to understand the aging factor and mechanism in different partitions of the beeswax-treated volumes, the duplicated beeswax-treated volume was artificially aged at $80^{\circ}C$ of temperature and 65% of relative humidity and then a physical and optical properties of an aged volumes was analyzed. Also, the degraded components of the beeswax samples isolated from different partitions of aged volumes was measured using a gas chromatography/mass spectroscopy (GC/MS). In results, the surface of beeswax-treated volume which is primarily affected by a main aging factors such as light, oxygen, moisture was more deteriorated than the inside of that volume. However, unlike inside of the book volume which was made from paper, the inside of beeswax-treated volume wax was also considerably deteriorated. The inside of the beeswax-treated volume is largely unaffected by the oxygen and humidity during aging due to the water repellency and the air permeation resistance of beeswax. Therefore, it is confirmed that aging factors and mechanisms in the inside of the volume are different from thats of the outside of the volume. This fact was also verified by the results of GC/MS analysis of an beeswax samples which was sampled from different partitions of aged volumes. As result as GC/MS analysis of the beeswax extracted from the outside of the aged volume, the low molecular compounds with a carbon length of $C_9-C_{20}$ (fatty acid, etc) were increased and the compounds with a carbon length of above $C_{34}$ (ester, etc) were also increased. But the compounds with a chain length of $C_{21}-C_{36}$ (hydrocarbon, alcohol, etc) were decreased. In case of the aged beeswax of inside, the low molecular compounds with a carbon length of $C_9-C_{20}$ (fatty acid, etc) and the compounds with a chain length of $C_{21}-C_{36}$ (hydrocarbon, alcohol, etc) were increased. While, the compounds with a carbon length of above $C_{34}$ (ester, etc) were decreased.

이류체 포그 냉방시스템의 제어알고리즘 개발 (Development of Control Algorithm for Greenhouse Cooling Using Two-fluid Fogging System)

  • 남상운;김영식;성인모
    • 생물환경조절학회지
    • /
    • 제22권2호
    • /
    • pp.138-145
    • /
    • 2013
  • 최근 국내에 많이 보급되고 있는 이류체 포그 냉방시스템의 효율적인 제어알고리즘을 개발하기 위하여 다양한 조건의 분무사이클을 설정하여 토마토재배 온실에서 냉방실험을 실시하였다. 냉방효과는 평균 $1.2{\sim}4.0^{\circ}C$를 보였고, 냉방효율은 평균 8.2~32.9%로 나타났다. 분무간격에 따른 실험에서 90초 분무사이클의 냉방효율이 가장 높았고, 대체로 분무시간이 길수록, 정지시간이 짧을수록 냉방효율이 높게 나타났다. 이류체 포그시스템의 분무량이 증가할수록 냉방효율이 높아지는 경향을 찾을 수 있었다. 그러나 분무량을 증가시키더라도 내부공기가 포화상태에 가까워지면 더 이상 증발이 일어나지 않으므로 내부공기가 포화상태에 도달하기 전까지 분무량을 증대시키는 방법으로 냉방효율을 높일 수 있을 것으로 판단된다. 냉방효율이 증가함에 따라 실내공기의 포차는 감소하였고 실내외 절대습도 차이는 증가하는 경향을 보였다. 포그의 증발량이 증가할수록 실내와 실외의 절대습도 차이는 커지고, 이에 따라 환기에 의한 수증기 배출이 잘 되어 다시 증발효율을 상승시키므로 냉방효율이 높아지는 순환구조를 갖게 되는 것으로 판단된다. 분무시간과 정지시간에 따른 실내공기의 포차변화를 회귀분석한 결과 $10g{\cdot}kg^{-1}$의 포차 변화에 필요한 분무시간은 120초, 정지시간은 60초로 나타났다. 그러나 온도의 진동폭을 줄이고 냉방효율을 높이기 위해서는 포차의 변동범위를 $5g{\cdot}kg^{-1}$으로 설정하여 60초 분무, 30초 정지가 더 적당할 것으로 판단된다. 이류체 포그시스템의 제어방식을 컴퓨터 제어시스템과 현재 보급되고 있는 간편제어시스템으로 분류하여 제어알고리즘을 유도하였다. 자연환기 온실에서 간편 제어시스템을 사용한다면 분무사이클을 60초 on, 30초 off로 설정하고 온도하한은 30~$30{\sim}32^{\circ}C$, 습도상한은 85~90%로 설정할 것을 제안한다.

유물 공간의 종합적 유해생물 관리(Integrated Pest Management)를 위한 실시간(Real-Time) 온습도 모니터링 및 유해 생물 조사 자료의 시각화 (Real-time Monitoring of Temperature and Relative Humidity and Visualization of Pest Survey Data for Integrated Pest Management in Collection Storage Area)

  • 임익균;임승덕;한규성
    • 보존과학회지
    • /
    • 제37권5호
    • /
    • pp.440-450
    • /
    • 2021
  • 수장고 및 전시 공간의 종합적 유해생물 관리를 위하여 실시간 온습도 센서 및 모듈을 이용한 환경 데이터 수집, 실내 부유 진균류 농도 및 곤충 유입 자료의 데이터 시각화를 부여 정림사지 박물관 유물 공간을 대상으로 실시하였다. 실시간 온습도 모니터링 시스템은 30분 단위로 측정 데이터를 수집하였으며 연동 애플리케이션을 통해 측정 데이터를 실시간으로 확인 가능하도록 하였다. 또한 측정된 온습도 데이터가 미리 설정한 범위를 초과하였을 경우, 푸시 알림을 담당자의 단말기로 전송하여 현황 정보를 제공함으로써 상시적 관리 체계를 구축하였다. 이를 통해 8월 중 유물 권장 온도 범위를 초과한 상황의 즉각적인 인지 및 조치가 가능하였다. 수장고 내부 공간에 따른 시기별 부유진균류 농도 데이터를 국립문화재연구소에서 제시한 생물학적 유해환경요인 권고기준(안) 기준으로 범례화하여 시각화한 결과, 수장고 1층과 2층 유물 공간 모두 위험 기준인 80 C.F.U./m3 이하의 부유 진균류 농도가 유지되는 것이 확인되었다. 또한 곤충 유입 조사 결과, 수장고 내부에는 곤충이 포획되지 않았으며, 전시공간의 경우, 딱정그리마, 알락귀뚜라미, 알락꼽등이 등의 곤충이 포획되었다. 이를 바탕으로 구역별 포획 곤충의 개체 밀도에 따른 시각화를 실시한 결과, 곤충의 주요 유입 경로가 외부 출입구 및 화장실 구역임을 확인할 수 있었다.

지능형 컨테이너 시스템의 구현과 퍼지 논리를 이용한 정보처리 (Implementation of Intelligent Container System and Information Processing Using Fuzzy Logic)

  • 손상혁;강근택;이원창
    • 한국지능시스템학회논문지
    • /
    • 제19권3호
    • /
    • pp.398-403
    • /
    • 2009
  • 최근 물류산업에 가장 중요한 부분인 컨테이너의 내부를 모니터링하여 보다 나은 물류시스템을 구현하고자 하는 노력이 많이 전개되고 있다. 본 논문에서는 지능형 컨테이너 시스템과 퍼지 논리를 이용하여 컨테이너 내부 상황을 인식하고 위험 상황을 판단할 수 있는 정보처리 시스템을 구현하였다. 지능형 컨테이너 시스템의 경우 모형 컨테이너에 ZigBee 노드를 부착하여 컨테이너 내부의 상태를 무선 환경에서 모니터링 할 수 있게 하였다. 또한 컨테이너 내부 상태에 대한 많은 데이터를 분석하여 내부 상황을 인식하고 위험 상황을 예측할 수 있는 정보처리 시스템을 퍼지 논리와 SCADA(Supervisory Control and Data Acquisition) 시스템인 InTouch를 이용하여 구현하였다.

노트북용 액정 모듈 내부의 온도 및 상대 습도 변화에 관한 실험적 연구 (Experimental Study of Internal Distribution of Temperature and Relative Humidity in Notebook LCD Module)

  • 김태우;김기빈;이재원
    • 대한기계학회논문집A
    • /
    • 제36권2호
    • /
    • pp.217-221
    • /
    • 2012
  • 노트북용 액정 모듈 내부의 광학 시트(Optical Sheet) 변형에 기인한 시인성 품질 불량을 개선하기 위한 기초 연구의 일환으로 변형 유발의 요인인 온도 및 습도의 영향을 분석할 수 있는 측정 시스템이 필요하였다. 액정 모듈 내부에는 0.5mm 미만의 미세한 공기 층이 존재하는데, 이 공간으로 외부의 습한 공기가 내부로 확산되는 것으로 추정된다. 이러한 현상을 규명하기 위하여 초소형 온도 및 습도 센서를 실장한 초박형 센서 PCB 를 액정 모듈 내부에 삽입하여 실시간으로 온/습도 변화를 측정 및 분석하였으며, 향후 변형 거동 시뮬레이션 및 구조 설계 시 필요한 기초 데이터로 활용하고자 한다.

공동주택 세대내 결로방지 설계를 위한 실내외 온습도 기준 수립 연구 (A Study on the Foundation of the Standard of Temperature and Humidity for Preventing Condensation in Apartment Housings)

  • 황하진;김종엽;이종성
    • 토지주택연구
    • /
    • 제2권3호
    • /
    • pp.269-276
    • /
    • 2011
  • 최근 공동주택은 에너지 절약을 위한 단열 및 기밀화로 자연 환기량이 감소되고, 세탁물의 실내 건조, 취사 및 목욕 등으로 인해 세대내 결로 발생가능성이 점점 높아지고 있다. 그러나 실제 생활실태나 환경조건을 반영한 합리적인 결로방지 설계기법이 부족한 상태이다. 따라서 본 연구에서는 이러한 문제점을 인식하고, 세대내 결로 방지 대처 방안을 강구하기 위해 실제 생활환경 하에서의 실내 온습도 상태를 측정하여 합리적인 결로방지 설계기준을 설정하고자 한다. 또한 기상데이터를 이용한 지역별 외기온의 분석을 통해 합리적인 지역구분 및 결로판정기준용 외기조건을 설정하고자 한다. 결과는 다음과 같다. 결로 판정을 위한 실내 기준은 기온 $25^{\circ}C$, 상대습도 55%로 설정하였다. 결로 판정을 위한 실외 기준은 지역을 혹한지, 중부 남부로 구분하고 기온을 각각 $20^{\circ}C$, $-15^{\circ}C$, $-10^{\circ}C$로 설정하였다.