• 제목/요약/키워드: Insertion angle

Search Result 140, Processing Time 0.028 seconds

A Fabrication of an Angle Trisection Tool Using Veprtskii's Method (Veprtskii의 방법을 활용한 각의 삼등분 도구 제작)

  • Han, Inki
    • Communications of Mathematical Education
    • /
    • v.36 no.4
    • /
    • pp.627-644
    • /
    • 2022
  • In this study various angle trisection tools based on Archimedes' insertion method were investigated, some tools were fabricated and their characteristics were compared. Through these works, it was found that factors such as the convenience of use, arbitrariness of the trisected angle, and simplicity of structure should be considered in the production and utilization of the trisection tool. Considering the factors described above, attention was paid to the method proposed by Veprtskii A.I. in 1888 as a making method of the angle trisection tool. In this study, we improved the method proposed by Veprtskii A.I., we used two wooden chopsticks and a string to make an angle trisection tool. The improved trisection tool had fewer parts than other trisection tools, a simple structure, and more convenient usage. In particular, this tool divided an arbitrary angle(not a specific angle) into the same three parts, and the production cost was low and the production process was simple. This tool is expected to be widely used in concrete activities related to the properties of the exterior angles of triangles and the properties of isosceles triangles in mathematics classrooms.

Development and Validation of a Vision-Based Needling Training System for Acupuncture on a Phantom Model

  • Trong Hieu Luu;Hoang-Long Cao;Duy Duc Pham;Le Trung Chanh Tran;Tom Verstraten
    • Journal of Acupuncture Research
    • /
    • v.40 no.1
    • /
    • pp.44-52
    • /
    • 2023
  • Background: Previous studies have investigated technology-aided needling training systems for acupuncture on phantom models using various measurement techniques. In this study, we developed and validated a vision-based needling training system (noncontact measurement) and compared its training effectiveness with that of the traditional training method. Methods: Needle displacements during manipulation were analyzed using OpenCV to derive three parameters, i.e., needle insertion speed, needle insertion angle (needle tip direction), and needle insertion length. The system was validated in a laboratory setting and a needling training course. The performances of the novices (students) before and after training were compared with the experts. The technology-aided training method was also compared with the traditional training method. Results: Before the training, a significant difference in needle insertion speed was found between experts and novices. After the training, the novices approached the speed of the experts. Both training methods could improve the insertion speed of the novices after 10 training sessions. However, the technology-aided training group already showed improvement after five training sessions. Students and teachers showed positive attitudes toward the system. Conclusion: The results suggest that the technology-aided method using computer vision has similar training effectiveness to the traditional one and can potentially be used to speed up needling training.

A Case Study on Lower Extremity Muscle of Elderly with Osteoarthritis in Ultrasonic Image (초음파영상에서 골관절염을 가진 노인의 하지 근육에 대한 사례연구)

  • Yoon, Se-Won;Park, Soo-Ji;Lee, Jeong-Woo
    • The Journal of the Society of Stroke on Korean Medicine
    • /
    • v.14 no.1
    • /
    • pp.102-106
    • /
    • 2013
  • ■ Objectives The purpose of the this study was to investigate organization change(pennation angle) of lower extremity muscle in elderly with knee osteoarthritis through ultrasonic image. Also, we examined organizational change of muscle was by influenced after total knee replacement(TKR). ■ Methods Rectus femoris image was taken at 50% of the distance between the anterior superior iliac spine and the superior border of the patella. Vastus medialis image was taken at the most distal insertion level of vastus medialis on the medial border of the patella. measurements included the most distal insertion level of the vastus medialis on the medial border of the patella. ■ Results Change of pennation angle in rectus femoris showed decrease from 5.11° in preoperation to 4.29° in 1 week after operation. Change of pennation angle in vastus medialis showed decrease from 6.94° in preoperation to 5.76° in 1 week after operation. ■ Conclusion We consider decrease of pennation angle after total knee replacement in this study was casued by organizational change of muscle and this pennation angle was influenced force created by muscle. Therefore, we thinks that this pennation angle through ultrasonic image will be available to plane individual muscle exercise program and to confirm muscle mass by muscle strength training.

  • PDF

Analysis of Arrayed Waveguide Grating Waveglength Filter using Wide Angle Beam Propagation Method (Wide Angle BPM 을 이용한 광도파로열 격자 파장 필터의 해석)

  • Park, Jun-O;Jeong, Yeong-Cheol
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.2
    • /
    • pp.46-55
    • /
    • 2002
  • The key component to accomplish the WDM all optical network is an Arrayed Waveguide Grating(AWG) wavelength filter Numerical analysis is necessary for design and analysis of optical components like AWG wavelength filter. Beam Propagation Method(BPM) is the most widely-used method. In this paper, we analyze the difference between the paraxial BPM and the WA-BPM when they are applied to the analysis of InP/InGaAsP/InP AWG wavelength filter. The paraxial BPM is based on paraxial approximation, and the WA-BPM is based on the low order Pade approximant. The side lobe level(SLL) and insertion loss calculated from both methods are compared. The high order Pade approximant will to used to more accurate design and analysis of AWG.

The Method of Virtual Reality-based Surgical Navigation to Reproduce the Surgical Plan in Spinal Fusion Surgery (척추 융합술에서 수술 계획을 재현하기 위한 가상현실 기반 수술 내비게이션 방법)

  • Song, Chanho;Son, Jaebum;Jung, Euisung;Lee, Hoyul;Park, Young-Sang;Jeong, Yoosoo
    • The Journal of Korea Robotics Society
    • /
    • v.17 no.1
    • /
    • pp.8-15
    • /
    • 2022
  • In this paper, we proposed the method of virtual reality-based surgical navigation to reproduce the pre-planned position and angle of the pedicle screw in spinal fusion surgery. The goal of the proposed method is to quantitatively save the surgical plan by applying a virtual guide coordinate system and reproduce it in the surgical process through virtual reality. In the surgical planning step, the insertion position and angle of the pedicle screw are planned and stored based on the virtual guide coordinate system. To implement the virtual reality-based surgical navigation, a vision tracking system is applied to set the patient coordinate system and paired point-based patient-to-image registration is performed. In the surgical navigation step, the surgical plan is reproduced by quantitatively visualizing the pre-planned insertion position and angle of the pedicle screw using a virtual guide coordinate system. We conducted phantom experiment to verify the error between the surgical plan and the surgical navigation, the experimental result showed that target registration error was average 1.47 ± 0.64 mm when using the proposed method. We believe that our method can be used to accurately reproduce a pre-established surgical plan in spinal fusion surgery.

Cervical Open-Door Laminoplasty by Hydroxyapatite Implant Insertion Without Suturing

  • Kawanabe, Yoshifumi;Fujimoto, Motoaki;Sato, Tsukasa
    • Neurospine
    • /
    • v.15 no.4
    • /
    • pp.362-367
    • /
    • 2018
  • Objective: To assess the efficacy of cervical open-door laminoplasty by hydroxyapatite implant insertion between the lamina and the lateral mass without suturing. Methods: All patients who underwent cervical open-door laminoplasty with C2/C7 undermining and insertion of hydroxyapatite implants from C3 to C6 were retrospectively evaluated for surgical time and neurological outcomes according to the Japanese Orthopaedic Association (JOA) score. To assess the alignment of the cervical spine and postoperative cervical pain, the C2-7 angle and a visual analogue scale score were used, respectively. Results: The population consisted of 102 women and 222 men ranging in age from 32 to 90 years. The average surgical time was 86 minutes. Fourteen of 1,296 hydroxyapatite implants were kept in place with sutures due to a weak restoration force of the hinge during surgery. No hydroxyapatite implant dislocation was detected on cervical computed tomography at 1 year after surgery. The average JOA score was $10.2{\pm}2.5$ before surgery and $14.6{\pm}2.8$ at 1 year after surgery. The average recovery rate was 61.8%. The average C2-7 angle at the neutral position was $7.1^{\circ}{\pm}6.2^{\circ}$ before surgery and $6.5^{\circ}{\pm}6.3^{\circ}$ at 1 year after surgery. Conclusion: This method enabled us to achieve minimal exposure of the lateral mass, prevention of lateral mass injury and dural injury, and a shorter surgical time while maintaining acceptable surgical outcomes. The idea that firm suture fixation is needed to prevent spacer deviation during cervical open-door laminoplasty may need to be revisited.

Effects of the Angulation of Orthodontic Mini-Implant as an Indirect Anchorage : A Three-Dimensional Finite Element Analysis (교정용 미니임플란트의 식립각도에 따른 간접골성 고정원의 효과에 대한 유한요소 해석)

  • Kim, Min-Ji;Park, Yong-Jin;Park, Sun-Hyung;Chun, Youn-Sic
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.3
    • /
    • pp.293-304
    • /
    • 2011
  • The purpose of this study was to investigate the displacement and pattern of stress distribution on periodontal ligaments of maxillary first and second molar, and on orthodontic mini-implant (OMI) surface, according to three different insertion angles to the bone surface of OMI using Dragon helix appliance, which is a newly introduced scissors-bite correcting appliance. OMI were placed between second premolar and first molar with three different insertion angles (45, 60, 90 degrees). Displacement and maximum stress distribution area (MSDA) were analyzed by finite element analysis. When the insertion angle to the alveolar bone surface was 90 degrees, maxillary first and second molar both exhibited MSDA at the palatal root apex. Maxillary first molar did not show any significant displacement, while the second molar exhibited intrusive and palatal displacement. On the OMI, as the insertion angle decreased, the MSDA shifted towards the tip, and the amount of displacement had increased. When the OMI was inserted at a 90 degree angle, anchor loss was minimized and scissors-bite correcting effect was maximized.

Relationship between Temporomandibular Joint Disorders and Horizontal Morphology of Lateral Pterygoid Muscle (외측 익돌근의 수평적 형태와 측두하악관절장애 간의 상관성)

  • Jung, Jae-Kwang;Kwon, Choonik;Byun, Jin-Seok;Choi, Jae-Kap
    • Journal of Oral Medicine and Pain
    • /
    • v.38 no.2
    • /
    • pp.149-159
    • /
    • 2013
  • The purpose of this study was to investigate the relationship between horizontal morphology of lateral pterygoid muscle and onset of temporomandibular joint disorders. Randomly selected 150 subjects, assigned with equal number in terms of gender and age group, were included. The axial and sagittal images in their magnetic resonance images of the temporomandibular joints were used to measure the morphologic characteristics of lateral pterygoid muscles and temporomandibular joints. The measurement variables were maximal horizontal width and insertion angle to the condyle, position of the articular disc, condylar deformity, and joint effusion. In addition, presence or absence of the temporomandibular joint pain was examined through history and palpation of the joints. The relationships among measurement variables were analyzed and the results were as follow. The insertion angle of the lateral pterygoid muscle to the condyle was higher in the joint of anterior disc displacement without reduction than that in the joint of normal disc position. In addition, the maximal horizontal width of the lateral pterygoid muscle was significantly increased in joints with pain than those without pain. Also, the insertion angle was significantly higher in younger age group and the maximal width was significantly greater in male than in female. These results suggest that high insertion angle of lateral pterygoid muscle might be an important anatomic predisposing factor for anterior disc displacement in temporomandibular joint and muscular activity of lateral pterygoid muscle might be affected by preauricular pain. In conclusion, there might be a bi-directional interaction between lateral pterygoid muscle and joint in the progression of anterior disc displacement in temporomandibular joint.

Three Dimensional Measurement of Ideal Trajectory of Pedicle Screws of Subaxial Cervical Spine Using the Algorithm Could Be Applied for Robotic Screw Insertion

  • Huh, Jisoon;Hyun, Jae Hwan;Park, Hyeong Geon;Kwak, Ho-Young
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.4
    • /
    • pp.376-381
    • /
    • 2019
  • Objective : To define optimal method that calculate the safe direction of cervical pedicle screw placement using computed tomography (CT) image based three dimensional (3D) cortical shell model of human cervical spine. Methods : Cortical shell model of cervical spine from C3 to C6 was made after segmentation of in vivo CT image data of 44 volunteers. Three dimensional Cartesian coordinate of all points constituting surface of whole vertebra, bilateral pedicle and posterior wall were acquired. The ideal trajectory of pedicle screw insertion was defined as viewing direction at which the inner area of pedicle become largest when we see through the biconcave tubular pedicle. The ideal trajectory of 352 pedicles (eight pedicles for each of 44 subjects) were calculated using custom made program and were changed from global coordinate to local coordinate according to the three dimensional position of posterior wall of each vertebral body. The transverse and sagittal angle of trajectory were defined as the angle between ideal trajectory line and perpendicular line of posterior wall in the horizontal and sagittal plane. The averages and standard deviations of all measurements were calculated. Results : The average transverse angles were $50.60^{\circ}{\pm}6.22^{\circ}$ at C3, $51.42^{\circ}{\pm}7.44^{\circ}$ at C4, $47.79^{\circ}{\pm}7.61^{\circ}$ at C5, and $41.24^{\circ}{\pm}7.76^{\circ}$ at C6. The transverse angle becomes more steep from C3 to C6. The mean sagittal angles were $9.72^{\circ}{\pm}6.73^{\circ}$ downward at C3, $5.09^{\circ}{\pm}6.39^{\circ}$ downward at C4, $0.08^{\circ}{\pm}6.06^{\circ}$ downward at C5, and $1.67^{\circ}{\pm}6.06^{\circ}$ upward at C6. The sagittal angle changes from caudad to cephalad from C3 to C6. Conclusion : The absolute values of transverse and sagittal angle in our study were not same but the trend of changes were similar to previous studies. Because we know 3D address of all points constituting cortical shell of cervical vertebrae. we can easily reconstruct 3D model and manage it freely using computer program. More creative measurement of morphological characteristics could be carried out than direct inspection of raw bone. Furthermore this concept of measurement could be used for the computing program of automated robotic screw insertion.

Free Hand Insertion Technique of S2 Sacral Alar-Iliac Screws for Spino-Pelvic Fixation : Technical Note, Acadaveric Study

  • Park, Jong-Hwa;Hyun, Seung-Jae;Kim, Ki-Jeong;Jahng, Tae-Ahn
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.6
    • /
    • pp.578-581
    • /
    • 2015
  • A rigid spino-pelvic fixation to anchor long constructs is crucial to maintain the stability of long fusion in spinal deformity surgery. Besides obtaining immediate stability and proper biomechanical strength of constructs, the S2 alar-iliac (S2AI) screws have some more advantages. Four Korean fresh-frozen human cadavers were procured. Free hand S2AI screw placement is performed using anatomic landmarks. The starting point of the S2AI screw is located at the midpoint between the S1 and S2 foramen and 2 mm medial to the lateral sacral crest. Gearshift was advanced from the desired starting point toward the sacro-iliac joint directing approximately $20^{\circ}$ angulation caudally in sagittal plane and $30^{\circ}$ angulation horizontally in the coronal plane connecting the posterior superior iliac spine (PSIS). We made a S2AI screw trajectory through the cancellous channel using the gearshift. We measured caudal angle in the sagittal plane and horizontal angle in the coronal plane. A total of eight S2AI screws were inserted in four cadavers. All screws inserted into the iliac crest were evaluated by C-arm and naked eye examination by two spine surgeons. Among 8 S2AI screws, all screws were accurately placed (100%). The average caudal angle in the sagittal plane was $17.3{\pm}5.4^{\circ}$. The average horizontal angle in the coronal plane connecting the PSIS was $32.0{\pm}1.8^{\circ}$. The placement of S2AI screws using the free hand technique without any radiographic guidance appears to an acceptable method of insertion without more radiation or time consuming.