• Title/Summary/Keyword: Insertion 4p

Search Result 349, Processing Time 0.033 seconds

Genetic Analysis of Caulobuter crescentus by Using Transposon Tn5 and Reverse Field Electrophoresis (Transposon Tn5 및 Reverse Field Electrophoresis를 이용한 Caulobuter crescentus의 유전자 분석 연구)

  • 구본성;버트일리
    • Microbiology and Biotechnology Letters
    • /
    • v.17 no.3
    • /
    • pp.183-187
    • /
    • 1989
  • The bacteriophage Mu and transposon Tn5 containing plasmid pJB4JI-transferred transposon Tn5 to Caulobuter crescentus. When several thousand of transposon Tn5 insertion mutants were examined, we found auxotrophic and motility mutants at frequencies of 2% and 3%, respectively. Transposition of transposon Tn5 was analyzed by the reverse field electrophoresis and Southern hybridization. The results indicated that transposon Tn5 was randomly inserted to Caulobuter crescentus chromosome but the plasmid vector, pJB4JI, was not maintained.

  • PDF

Performance Improvement of Polymer Light Emitting Diodes by Insertion of a Silane Layer

  • Lee, Jun-Yeob
    • Journal of Information Display
    • /
    • v.8 no.3
    • /
    • pp.1-4
    • /
    • 2007
  • The influence of a silane layer on the performances of polymer light emitting diode(pLED)s has been studied. Glycidoxypropyltrimethoxysilane(GPS) with an epoxy functional group was used as a surface modifier for ITO substrates. The GPS layer was inserted between an ITO and a poly(3,4)-ethylenedioxythiophene/polystyrenesulfonate(PEDOT) by wet process and the performances of PLEDs were investigated. The introduction of GPS layer increased the brightness and efficiency of PLEDs by 30%. In addition, the lifetime of PLEDs was also improved considerably by using GPS as a surface modifier.

Palladium(II) p-Tolylamide and Reaction with CO2 to Generate a Carbamato Derivative

  • Seul, Jung-Min;Park, Soon-Heum
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.12
    • /
    • pp.3745-3748
    • /
    • 2010
  • Pd(II) p-tolylamide Pd(2,6-$(Ph_2PCH_2)_2C_6H_3$)(NH($C_6H_4Me$-p)) (1) was metathetically prepared by the reaction of Pd(2,6-$(Ph_2PCH_2)_2C_6H_3$)Cl with NaNH($C_6H_4Me$-p). Treatment of 1 with carbon dioxide affords the palladium(II) carbamate Pd(2,6-$(Ph_2PCH_2)_2C_6H_3$)(OC(O)NH($C_6H_4Me$-p)) (2), quantitatively. Complex 2 reacts with HX (X = Cl, OTf) to give Pd(2,6-$(Ph_2PCH_2)_2C_6H_3$)X, $NH_2$(p-Tol) and $CO_2$. Reaction of the palladium(II) carbamate with MeI produced Pd(2,6-$(Ph_2PCH_2)_2C_6H_3$)I along with generation of methyl N-tolylcarbamate MeOC(O)NH($C_6H_4Me$-p), exclusively.

Efficacy and Cost-Effectiveness of Portable Small-Bore Chest Tube (Thoracic Egg Catheter) in Spontaneous Pneumothorax

  • Joh, Hyon Keun;Moon, Duk Hwan;Lee, Sungsoo
    • Journal of Chest Surgery
    • /
    • v.53 no.2
    • /
    • pp.49-52
    • /
    • 2020
  • Background: Primary spontaneous pneumothorax is commonly treated with chest tube insertion, which requires hospitalization. In this study, we evaluated the efficacy, costs, and benefits of a portable small-bore chest tube (Thoracic Egg; Sumitomo Bakelite Co. Ltd., Tokyo, Japan) compared with a conventional chest tube. Methods: We retrospectively analyzed all primary spontaneous pneumothorax patients who underwent treatment at Gangnam Severance Hospital between August 2014 and May 2018. Results: A total of 279 patients were divided into 2 groups: the conventional group (n=236) and the Thoracic Egg group (n=43). Of the 236 patients in the conventional group, 100 were excluded because they underwent surgery during the study period. The efficacy and cost were compared between the 2 groups. There was no statistically significant difference between the groups regarding recurrence (conventional group, 36 patients [26.5%]; Thoracic Egg group, 15 patients [29.4%]; p=0.287). However, the Egg group had statistically significantly lower mean medical expenses than the conventional group (433,413 Korean won and 522,146 Korean won, respectively; p<0.001). Conclusion: Although portable small-bore chest tubes may not be significantly more efficacious than conventional chest tubes, their use is significantly less expensive. We believe that the Thoracic Egg catheter could be a less costly alternative to conventional chest tube insertion.

The Effect of Early IASP and Reperfusion Therapy in Patient of Post MI Cardiogenic Shock (Post MI Cardiogenic Shock 환자에서 조기 IABP 및 Reperfusion Therapy의 효과)

  • Lee, Jong-Suk;Kim, Min-Kyeung;Kim, Woong;Kim, Hyung-Jun;Bae, Jun-Ho;Park, Jong-Sean;Sin, Dong-Gu;Kim, Young-Jo;Shim, Bong-Sup
    • Journal of Yeungnam Medical Science
    • /
    • v.17 no.1
    • /
    • pp.31-38
    • /
    • 2000
  • Background: We sought to examine the use and outcomes of early intraaortic balloon counterpulsation(IABP) combined with early reperfusion therapy in patients presenting cardiogenic shock complicated acute myocardial infarction. The usc of IABP in patients with cardiogenic shock is widely accepted. However there is not ample information on the use of this technique in patients with cardiogenic shock who arc treated with reperfusion therapy in Korea. Materials and Methods: Twenty-eight patients presented with cardiogenic shock were classified into two groups: the early IABP group (insertion within 12 hours after AMI onset time) and the late IABP group (insertion after 12 hours). We compared In-hospital mortality between the two groups (early IABP group vs late IABP group). Results: Two groups showed no significant difference in clinical feature and coronary angiographic results. Among total 28 patients, 7 patients were treated with thrombolytic therapy and 21 patients with PTCA. Insertion site bleeding, fever, thrombocytopenia were reported as some of the complications of IABP insertion. In-hospital mortalities in the early IABP group and late IABP group were 4 patients(25%) and 8 patients(66%), respectively(p<0.05). Early IABP insertion and early PTCA showed lower hospital mortality rates. There was significant difference in the time to PTCA after AMI onset between the two groups(p<0.05). Conclusion: IABP appears to be useful in patients presenting cardiogenic shock unresponsive medical therapy. Early IABP insertion and early reperfusion therapy may reduce in-hospital mortality rates of post-MI cardiogenic shock patients.

  • PDF

A STUDY ON THE MARGINAL LEAKAGE OF CLASS II LIGHT CURING COMPOSITE RESIN RESTORATION ACCORDING TO FILLING METHODS (2급와동 광중합 복합레진의 충전방법에 따른 변연누출에 관한 실험적 연구)

  • Kim, Kyung-Hyun;Kwon, Hyuk-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.1
    • /
    • pp.55-72
    • /
    • 1993
  • The aim of this study was to compare the marginal leakage of class II light curing composite resin restoration according to filling methods. With using acid etching technique and dentin bonding agent, various methods were suggested to eliminate or reduce the marginal leakage. In this study, class II cavities were prepared in 100 extracted human premolars with cementum margin(1mm below the CEJ) and the teeth were randomly assigned to 5 groups of 20 teeth each. The teeth in group 1, 2, 3 and 4 were restored by direct filling methods using P-50 and Clearfil Photoposterior of 10 teeth each, but the method of insertion of the restorative materials varied with each group. And the teeth in group 5 were restored by inlay method using Kulzer Inlay and CR Inlay. Filling methods are as follows : Group 1 : The composite resin was inserted in one layer in the proximal box and one layer in the occlusal portion. Group 2 : Insertion was in two equally thick horizontal layers in the proximal box. Group 3 : Insertion was in two diagonally placed layers in the proximal box. Group 4 : The composite resin was inserted in the same way as in group 3 except that a glass ionomer liner was first placed on the axial wall and gingival floor. Group 5 : The teeth were restored by Inlay technique using dure cure resin cement. All the teeth were thermocycled, stained with 1 % methylene blue solution, sectioned mesiodistally, and scored for marginal leakage. To compare the marginal leakage, ANOVA and T-test were used in analysis. The following results were obtained : 1. In direct filling methods, there was no significant difference in marginal leakage at both occlusal and cervical margins. 2. In all groups, occlusal margin showed significantly less leakage than cervical margin. 3. In group using glass ionomer liner, there was no significant reduction of marginal leakage at the cervical margin. 4. The group restored by inlay method showed significantly less marginal leakage than groups restored by direct filling methods at both occlusal and gingival margins. 5. There was no significant difference in each group according to filling materials.

  • PDF

Effect of Previous Gastrectomy on the Performance of Postoperative Colonoscopy

  • Kim, Sunghwan;Choi, Jeongmin;Kim, Tae Han;Kong, Seong-Ho;Suh, Yun-Suhk;Im, Jong Pil;Lee, Hyuk-Joon;Kim, Sang Gyun;Jeong, Seung-Yong;Kim, Joo Sung;Yang, Han-Kwang
    • Journal of Gastric Cancer
    • /
    • v.16 no.3
    • /
    • pp.167-176
    • /
    • 2016
  • Purpose: The purpose of this study was to determine the effect of a prior gastrectomy on the difficulty of subsequent colonoscopy, and to identify the surgical factors related to difficult colonoscopies. Materials and Methods: Patients with a prior gastrectomy who had undergone a colonoscopy between 2011 and 2014 (n=482) were matched (1:6) to patients with no history of gastrectomy (n=2,892). Cecal insertion time, intubation failure, and bowel clearance score were compared between the gastrectomy and control groups, as was a newly generated comprehensive parameter for a difficult/incomplete colonoscopy (cecal intubation failure, cecal insertion time >12.9 minutes, or very poor bowel preparation scale). Surgical factors including surgical approach, extent of gastrectomy, extent of lymph node dissection, and reconstruction type, were analyzed to identify risk factors for colonoscopy performance. Results: A history of gastrectomy was associated with prolonged cecal insertion time ($8.7{\pm}6.4$ vs. $9.7{\pm}6.5$ minutes; P=0.002), an increased intubation failure rate (0.1% vs. 1.9%; P<0.001), and a poor bowel preparation rate (24.7 vs. 29.0; P=0.047). Age and total gastrectomy (vs. partial gastrectomy) were found to be independent risk factors for increased insertion time, which slowly increased throughout the postoperative duration (0.35 min/yr). Total gastrectomy was the only independent risk factor for the comprehensive parameter of difficult/incomplete colonoscopy. Conclusions: History of gastrectomy is related to difficult/incomplete colonoscopy performance, especially in cases of total gastrectomy. In any case, it may be that a pre-operative colonoscopy is desirable in selected patients scheduled for gastrectomy; however, it should be performed by an expert endoscopist each time.

Efficacy of Pigtail Catheter Drainage in Patients with Thoracic Empyema or Complicated Parapneumonic Effusion (농흉 및 합병된 부폐렴성 흉막 삼출 환자에서 Pigtail 도관 배액의 유용성)

  • Park, Jeong Woo;You, Seung Min;Seol, Won Jong;Paik, Eun Ki;Lee, Kyu Hoon;Seo, Joon Beom;Jeong, Seong Hwan;An, Chang Hyeok;Lim, Youg Hee;Park, Jeong Woong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.54 no.2
    • /
    • pp.219-229
    • /
    • 2003
  • Background : The management of thoracic empyema and complicated parapneumonic effusion requires adequate antibiotics use and prompt drainage of infected pleural space. Tube thoracostomy for loculated empyema has low success rate and is also an invasive procedure with potential morbidity. Complications include hemothorax, perforation of intra-abdominal or intra-thoracic organs, diaphragmatic laceration, empyema, pulmonary edema, and Horner's syndrome. Given the potential morbidity of traditional chest tube insertion, use of the image-guided pigtail catheter drainage(PCD) of empyema has been employed. We retrospectively analyzed the medical records of patients with empyema or complicated parapneumonic effusion to determine the efficacy of percutaneous pigtail catheter drainage. Materials and Methods : 45 patients with complicated parapneumonic effusions or empyema were treated at Gil medical center from January 1998 to June, 1999. All were initially given PCD procedure and the following data were collected: clinical symptoms at the time of diagnosis, alcohol and smoking history, the characteristics of pleural effusion, radiologic findings (at the time of catheter insertion, removal and 1 month after catheter removal), the amount of effusion drained for initial 24 hours, the time from catheter insertion to removal and the use of surgical approach. Results : Male gender was more frequent (42 men vs. 3 women), the mean age of the study population was 52(range: 21~74) years. Empyema was found in 23 patients, complicated parapneumonic effusion in 22 patients. Four patients(three, parapneumonic effusion and one, with empyema) with PCD only treated, were cast off. Among the available patients, 36(80%) patients were treated with PCD only or PCD with urokinase. Among the 23 patients with empyema, surgical approach was required in five patients(27.1%, one required decortication, four open thoracostomy), one patient, treated with surgical procedure, died of sepsis. There was no significant difference of the duration of catheter insertion, the duration of hospital admission after catheter insertion and the mean amount of effusion drained for initial 24 hours between the patients with only PCD treated and the patients treated with PCD and urokinase. The duration of catheter insertion($9.4{\pm}5.25days$ vs. $19.2{\pm}9.42days$, p<0.05) and the duration of hospital admission after catheter insertion($15.9{\pm}10.45days$ vs. $38.6{\pm}11.46days$, p<0.01) of the patients with only PCD treated were more longer than those of the patients treated with surgical procedure after PCD. They were same between the patients treated with urokinase after PCD and the patients treated with surgical procedure after PCD($11.1{\pm}7.35days$ vs. $19.2{\pm}9.42days$, p<0.05, $17.5{\pm}9.17days$ vs. $38.6{\pm}11.46days$, p<0.01). In 16 patients(44.4%) with only PCD treated or PCD and urokinase treated, the amount of effusion at the time of catheter removal was decreased more than 75% and in 17 patients(47.2%) effusion decreased 50~75%. .In one patient effusion decreased 25~50%, in two patients effusion decreased less than 25%. One month after catheter removal, in 35 patients(97.2%, four patients were cast off), the amount of pleural effusion was successfully decreased more than 50%. There were no complications related to pigtail catheter insertion. Conclusion : In this study, PCD seemed to be an early efficacious procedure in treating the patients with complicated parapneumonic effusion or empyema without any serious procedure related complication.

Comparative Biomechanical Study of Self-tapping and Non Self-tapping Tapered Dental Implants in Artificially Simulated Quality 2 Bone

  • Baek, Yeon-Wha;Kim, Duck-Rae;Park, Ju-Hee;Lim, Young-Jun
    • Journal of Korean Dental Science
    • /
    • v.4 no.2
    • /
    • pp.52-58
    • /
    • 2011
  • Purpose: Modifications of implant design have been related to improving initial stability. The purpose of this study was to investigate their respective effect on initial stability between two tapered implant systems (self-tapping vs. non-self-tapping) in medium density bone using three different analytic methods. Materials and Methods: Self-tapping implant (GS III$^{(R)}$; Osstem Implant Co., Busan, Korea) and non-self-tapping implant (Replace Select$^{(R)}$; Nobel Biocare, G$\H{o}$teborg, Sweden) were investigated. In Solid rigid polyurethane blocks of artificially simulated Quality 2 bone, each of the 5 implants was inserted according to the manufacturer's instructions for medium-bone drilling protocol. Evaluation of initial stability was carried out by recording the maximum insertion torque (IT) and performing the resonance frequency analysis (RFA), and the pull-out test. Results: The IT and RFA values of self-tapping implant were significantly higher than those of non self-tapping implant (P=.009 and P=.047, respectively). In the pull-out values, no significant differences were found in implants between two groups (P=.117). Within each implant system, no statistically significant correlation was found among three different outcome variables. Conclusions: These findings suggest that design characteristics of implant geometry significantly influence the initial stability in medium bone density.

Charge-coupled analog-to-Digital Converter (전하결합소자를 이용한 Analog-to-Digital 변화기)

  • 경종민;김충기
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.18 no.5
    • /
    • pp.1-9
    • /
    • 1981
  • Experimental results on a 4-bit charge-coupled A/D converter are described. Major operations in the successive approximation algorithm are implemented in a monolithic chip, CCADC, which was fabricated usir p-channel CCD technology, with its die size of 4,200 mil2 Typical operating frequency range has been found out to be from 500Hz to 200kHz. In that frequency range, no missing code has been found in the whole signal range of 2.4 volts for ramp signal slewing at 1 LSB/(sampling time). A discussion is made on several layout techniques to conserve the nominal binary ratio of (8:4:2:1) among the areas of four adjacent potential wells (M wells), whose charge storing capacities correspond to each bit magnitude - 3.6 pC, 1.8 pC, 0.9 pC, and 0.45 pC nominal in the order of MSB to the LSB. The effect of 'dump slot', which is responsible for the excessive nonlinearity (2$\frac{1}{2}$LSB) in the A/D converter, is explained. A novel input scheme called 'slot zero insertion' to circumvent the deleterious effects of the dump slot is described with the experimental results.

  • PDF