• Title/Summary/Keyword: Input system

Search Result 11,540, Processing Time 0.042 seconds

Stimulated Raman scattering at 1.54${\mu}m$ and Brillouin scattering at 1.06${\mu}m$ in $CH_4$ under 5 Hz repetition rate (반복률과 라만매질 압력에 따른 1.54 ${\mu}m$ 전방, 후방 유도라만 및 1.06${\mu}m$ Brillouin 산란광의 출력특성)

  • 최영수;전용근;김재기
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.2
    • /
    • pp.95-101
    • /
    • 1999
  • We have studied the 1.54$\mu\textrm{m}$ forward and backward stimulated Raman scattering (SRS) and stimulated Brillouin scattering (SRS) for various $CH_4$pressures by 1.06$\mu\textrm{m}$ Q-switched Nd:YAG laser pumping under a repetition rate of Hz in single pass. We obtained that the output of backward SRS was more efficient than that of the forward SRS. The output energy and conversion efficiency of forward and backward SRS were higher than those of SBS since SRS is a steady state, but SBS is a transient state. In a $CH_4$gas uncirculating system, the output energy of the backward SRS and SBS were reduced the about 47% due to a thermal heating of $CH_4$medium in a focusing region for a repetition rate of 5 Hz. But, the output energy of forward SRS was slightly enhanced by about 8.5% due to the increase of the undepleted pump beam in the backward SRS generation. Inthe Raman half resonator using a dichromatic focusing lens, the conversion efficiency of SRS was more than 37% for a input pump laser energy of 40 mJ.

  • PDF

Technical Review on Methodology of Generating Exposure Scenario in eSDS of EU REACH (유럽 신화학물질관리제도의 eSDS에 첨부되는 노출시나리오 작성법 개발 동향)

  • Choe, Eun-Kyung;Kim, Jong-Woon;Kim, Sang-Hun;Byun, Sung-Won
    • Clean Technology
    • /
    • v.17 no.4
    • /
    • pp.285-299
    • /
    • 2011
  • As one of the REACH obligations, the extended safety data sheet (eSDS) should be communicated within the supply chain under the REACH Regulation. Based on technical guidance documents published on the ECHAs website and survey of EU's recent REACH-related informations, this paper includes a study on details of how to develop exposure scenarios (ES) such as structure of ES, process of ES develpoment, standard workflows and key input data to develop ES with an introduction of eSDS concept. This paper also contains an overview on operational conditions (OCs) and risk management measures (RMMs) that are what to consider when building an ES. The structure of Chesar (Chemical Safety Assessment and Report tool) developed by European Chemicals Agency (ECHA) is studied with a review of the available exposure estimation tools for workers, environment and consumers. Case example of generic exposure scenario (GES) for organic solvent is presented. To guide Korean EU-exporting companies, their participating roles in three steps of preparing ES are addressed.

A Study on the Surface-Radiation Heat Transfer Characteristics in an Open Cavity with a Heat Source (발열체가 존재하는 개방된 정사각형공간에서 표면복사 열전달 특성에 관한 연구)

  • Nam, Pyoung-Woo;Park, Myoung-Sig;Park, Chan-Woo
    • Solar Energy
    • /
    • v.12 no.3
    • /
    • pp.70-83
    • /
    • 1992
  • The interaction between the surface radiation and the mixed convection transport from an isolated thermal source, with a uniform surface heat flux input and located in a rectangular enclosure, is stuied numerically. The enclosure simulates a practical system such an air cooled electric device, where an air-stream flows through the openings on the two vertical walls. The heat source represents an electric component located in such an enclosure. The size of this cavity is $0.1[m]{\times}0.1[m]$. The inlet velocity is assumed as 0.07[m/s] and the inlet temperature is maintained as $27^{\circ}C$. The inflow is kept at a fixed position. Laminar, two dimensional flow is assumed, and the problem lies in the mixed convection regime, governed by buoyancy force and surface readiation. The significant variables include the location of the out-flow opening, of the heat source and the wall emissivity. The basic nature of the resulting interaction betwwn the externally induced air stream and the buoyancy-driven flow generated by the source is investigated. As a result, the best location of the heat source to make the active heat transfer is 0.075[m] from the left wall on the floor. The trends observed are also discussed in terms of heat removal from practical systems such as electric circuitry.

  • PDF

Real Time Environmental Classification Algorithm Using Neural Network for Hearing Aids (인공 신경망을 이용한 보청기용 실시간 환경분류 알고리즘)

  • Seo, Sangwan;Yook, Sunhyun;Nam, Kyoung Won;Han, Jonghee;Kwon, See Youn;Hong, Sung Hwa;Kim, Dongwook;Lee, Sangmin;Jang, Dong Pyo;Kim, In Young
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.1
    • /
    • pp.8-13
    • /
    • 2013
  • Persons with sensorineural hearing impairment have troubles in hearing at noisy environments because of their deteriorated hearing levels and low-spectral resolution of the auditory system and therefore, they use hearing aids to compensate weakened hearing abilities. Various algorithms for hearing loss compensation and environmental noise reduction have been implemented in the hearing aid; however, the performance of these algorithms vary in accordance with external sound situations and therefore, it is important to tune the operation of the hearing aid appropriately in accordance with a wide variety of sound situations. In this study, a sound classification algorithm that can be applied to the hearing aid was suggested. The proposed algorithm can classify the different types of speech situations into four categories: 1) speech-only, 2) noise-only, 3) speech-in-noise, and 4) music-only. The proposed classification algorithm consists of two sub-parts: a feature extractor and a speech situation classifier. The former extracts seven characteristic features - short time energy and zero crossing rate in the time domain; spectral centroid, spectral flux and spectral roll-off in the frequency domain; mel frequency cepstral coefficients and power values of mel bands - from the recent input signals of two microphones, and the latter classifies the current speech situation. The experimental results showed that the proposed algorithm could classify the kinds of speech situations with an accuracy of over 94.4%. Based on these results, we believe that the proposed algorithm can be applied to the hearing aid to improve speech intelligibility in noisy environments.

Comparison Study on the Inventory Management in SCM using Simulation (시뮬레이션을 활용한 공급사슬 내 재고관리 방법 비교 연구)

  • Lee, Jae-Hong;Gu, Seung-Hwan;Noh, Seung-Min;Jang, Seong-Yong
    • Journal of the Korea Society for Simulation
    • /
    • v.24 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • This research focuses on the method of inventory management to find out the best way in various SCM. There are several comparable methods of inventory management like Min-Max, regular interval, fixed target inventory that have different lead-time and demand for each product. Also, the inventory performances between the case of three-stages and two-stages in SCM are analyzed. 8 scenarios for the simulation are suggested considering order ways and stages. Input data for the simulation is from the result of the previous studies and actual data in the market. The performance measurements are selected as sales revenue, total number of sales, total delivery cost, total inventory shortages, the number of inventory shortage occurrence, the loss for inventory shortages, average inventory, handling cost, net profit. According to the results of the simulation, fixed target inventory management is better than existing inventory management method by net profit and inventory and so on. Also, it was confirmed that the increase in profit is obtained when SCM stages is reduced from three-stages to two-stages in existing SCM. The result of the research provides significant meaning that newly introduced target inventory management system shows good performance and SCM performance can be improved by reducing the stages.

Study on The Warranty of Opposing Through Flow Gap Acceptance Time for more Efficient Management of Permissive Left-Turn (비보호 좌회전 효율성 제고를 위한 대향 직진 교통류의 Gap-Time기준 연구)

  • Baik, Seung-Yup;Park, Ki-Soo
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.10 no.4
    • /
    • pp.107-115
    • /
    • 2011
  • Since 2009 The Korean National Police Agency has been pushed "permissive left-turn" forward in order to making progress in Korean traffic operations system. Preceding researches manuals and guidelines present 6 standards(# of accidents # of lanes, pedestrian volume sight # of permissive left-turn lanes vehicle volume) as installation permissive left-turn. But in practical affairs it is most important that secure enough Gap-time between permissive left-turn vehicle and opposite through lane vehicle to make permissive left-turn vehicle move safer and more efficiently. This study suggests applying gap acceptance theory in microscopic model to permissive left-turn installation standards. Analysis methods of this study are field data survey statistical analysis and microscopic simulation analysis. This study collected field data by using AVI recording and measured permissive left-turn vehicle intersection passing time(T1) and against the opposite through lane vehicle Gap-time(T2). And statistical analysis performed about two values that measured before to predict the functionality between T1 and T2. These studies to overcome the limit of sample size carried out a microscopic simulation(VISSIM) plan and collect more samples to input statistical analysis.

Modeling and Application Research of Zero Crossing Detection Circuit (Zero Crossing Detection 회로 Modeling 및 응용연구)

  • Jeong, Sungin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.4
    • /
    • pp.143-148
    • /
    • 2020
  • In the case of a system that detects and controls the phase of an alternating voltage, the analog control method compensates the phase offset part by filtering for the detected phase and applies it to the control. However, in the digital control method, precise control cannot be achieved due to an error between the operating frequency of the microprocessor or the microcontroller and the input phase time when controlled using such phase detection. In general, when the method used is a certain time, the accumulated error is compensated and adjusted at random. To solve this problem, a method of detecting a zero point in real time and compensating for the operating frequency of the microprocessor is needed. Therefore, the research to be performed in this paper to reduce these errors and apply them to precise digital control is as follows. 1) Research on how to implement Zero Crossing Detection algorithm through simulation modeling to compensate the zero point to match the operating frequency through detection. 2) A study on the method of detecting zero points in real time through the Zero Crossing Detection design using a microcontroller and compensating for the operating frequency of the microprocessor. 3) A study on the estimation of the rotor position of BLDC motors using the Zero Crossing Detection circuit.

Semi-active Control of a Seismically Excited Cable-Stared Bridge Considering Dynamic Models of MR Fluid Damper (MR 유체 댐퍼의 동적모델을 고려한 사장교의 반(半)능동제어)

  • Jung, Hyung-Jo;Park, Kyu-Sik;Spencer, B.F.,Jr;Lee, In-Won
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.6 no.2
    • /
    • pp.63-71
    • /
    • 2002
  • This paper examines the ASCE first generation benchmark problem for a seismically excited cable-stayed bridge, and proposes a new semi-active control strategy focusing on inclusion of effects of control-structure interaction. This benchmark problem focuses on a cable-stayed bridge in Cope Girardeau, Missouri, USA, for which construction is expected to be completed in 2003. Seismic considerations were strongly considered in the design of this bridge due to the location of the bridge in the New Madrid seismic zone and its critical role as a principal crossing of the Mississippi River. In this paper, magnetorheological(MR) fluid dampers are proposed as the supplemental damping devices, and a clipped-optimal control algorithm is employed. Several types of dynamic models for MR fluid dampers, such as a Bingham model, a Bouc-Wen model, and a modified Bouc-Wen model, are considered, which are obtained from data based on experimental results for full-scale dampers. Because the MR fluid damper is a controllable energy-dissipation device that cannot add mechanical energy to the structural system, the proposed control strategy is fail-safe in that bounded-input, bounded-output stability of the controlled structure is guaranteed. Numerical simulation results show that the performance of the proposed semi-active control strategy using MR fluid dampers is quite effective.

The Vector Control with Compensating Unit Angle for the Robust Low Speed Control of Induction Motor (유도전동기의 강건한 저속 제어를 위한 단위각 보상 벡터 제어)

  • 원영진;박진홍
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.35T no.1
    • /
    • pp.90-98
    • /
    • 1998
  • This paper is to describe the improved vector control which can control the induction motor robustly in low speed. When the induction motor is drived with low speed, below 10 percent of the rated speed, an algorithm which can compensate the error of unit vector angle generated by the harmonics is proposed. Another algorithm which can be tuned to the rotor time constant so that nay be robust to the rotor parameter change in low speed and transient state was proposed. The ripple of flux and torque was reduced by the proposed vector control and then the stable output characteristics was obtained in low speed. When the input and output is sinusoidal, the proposed vector control, the direct vector control and the indirect vector control were analyzed and compared in the low speed characteristics. And each control characteristics is compared and analyzed in state of containing harmonics. The estimation and tunning performance of rotor time constant is confirmed with simulation. The whole control system is implemented by real hardware and experimented to compare the proposed vector control with the direct vector control. As a result of the experiment with two control methods in low speed, the torque ripple of the proposed vector control is improved by 45 percent than the direct vector control. And it is confirmed that the flux current ripple is reduced in 0.2 p.u. and torque current ripple is reduced in 0.6 p.u. It is confirmed that the rotor time constant by the estimation and the tunning algorithm is tunned by the real rotor time constant. Finally, it was confirmed that the validity and robustness for the proposed vector control in low speed existed.

  • PDF

Inverse Characterization Method Based on 9 Channel Tone Response Curves for Display Device (디스플레이 장치를 위한 9개 채널 계조 응답 곡선에 기반한 역 특성화 기법)

  • Im, Hye-Bong;Cho, Yang-Ho;Park, Kee-Hyon;Ha, Yeong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.42 no.5 s.305
    • /
    • pp.85-94
    • /
    • 2005
  • Display characterization, deriving the relationship between digital input values and the corresponding CIEXYZ tri-stimulus values, is important to reproduce the accurate color in color management system. The relationship can be estimated from the nine channel TRCs(tone response curves) and the result of this characterization method is better than that of using three channel TRCs. However, the inverse display characterization using nine channel TRCs cannot be directly inverted because the CIEXYZ values corresponding to each of RGB values are inseparable. Accordingly, inverse display characterization is usually implemented by the 3D-LUT (look-up table) method. Although the result of 3B-LUT is accurate, creating the 3D-LUT requires a lot of memory space and considerable amount of measurements. Therefore the inverse characterization method is proposed based on the modeling of channel-dependent values and nine channel inverse process based on the GOG(gain, offset gamma) model. The proposed method enhances the accuracy of display characterization and reduces the complexity and the number of measurements data required for accuracy in 3-D LUT.