• 제목/요약/키워드: Input power decrease

검색결과 125건 처리시간 0.023초

변압기 탭을 이용한 태양광인버터의 성능개선 (Performance improvement of PV_system's inverter that use transformer tap)

  • 박노식;박성준;김광헌;임영철;권순재;김철우
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(2)
    • /
    • pp.511-514
    • /
    • 2004
  • Proposed about new inverter that can use in PV system in this paper. Multi_level inverter that used inverter makes use of 4 transformers is basis, primary winding of each transformer voltage as can do step_up or step_down to appropriate voltage space tap lake. Put circuit that tap that turn in transformer connects properly according to inhibit signal that sense change of input voltage (output voltage of solar cell place) and transformer secondary voltage controls point of contact of relay so that get into fixed output voltage. As a result, can minimise relative harmonic content despite change width of input voltage are wide because number of output voltage level of multi_level inverter does not decrease. Because proposed circuit manufactures is easy and control is easy and is no burden of cost price rise economically, commercialization expected to do easily and this study examined propriety of action as that compose and experiments proposed circuit.

  • PDF

컴퓨터 CPU 냉각용 미세채널 워터블록의 열성능에 관한 연구 (A Study on Thermal Performance of Micro Channel Water Block for Computer CPU Cooling)

  • 권오경;최미진;차동안;윤재호
    • 대한기계학회논문집B
    • /
    • 제32권10호
    • /
    • pp.776-783
    • /
    • 2008
  • The object of this paper is to study on the thermal performance of a micro channel water block for computer CPU cooling. The effects of liquid flow rate, micro channel width and height on the thermal performances of water block are investigated experimentally. The water block was fabricated Al and machined with a micro milling. The water block consisted of rectangular micro channels 0.5 to 0.9 mm width and 1.5 to 4.5 mm height. The experiments were conducted using deionized water, over a liquid flow rate ranging from 0.2 to 2.0 kg/min. The base temperature and thermal resistance decrease with increasing of liquid flow rate. The increase of a channel height is more effective on the thermal resistance than the decrease of a channel width. At the flow rate of 0.7 kg/min, input power of 100 W, the base temperature and thermal resistance of sample 6 is $33^{\circ}C$ and $0.13\;^{\circ}C/W$ respectively.

Reuses Of Wash Water Effluents Of The Ion-Exchanger Units Of Water Demineralization Plant For Economic And Environmental Benefits

  • Miah, Raisuddin
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.799-806
    • /
    • 1995
  • In industrial field, a large volume of regenerants (acid and caustic soda) and their washing effluents are regularly disposed off from the water demineralization plant during regeneration of the ion-exchanger units. Of these waste effluents, a part of the wash water discharged from the single bed Anion and Mixed Bed units can be utilized at a certain stage of their washing cycles when its conductivity is fallen down and becomes considerably less than that of the input raw water. The main aim of this specific waste effluent utilization is to dilute the TDS concentration of the input raw water (fed into the single bed ion-exchanger units) by blending. The achievement is the increase of the longevity of the production cycles of the I.E. units along with the improvement of the production quality and decrease of the regeneration frequencies. As a result, regenerant consumption would be saved because of the reduction of ionic load in feed water which will ultimately reduce the water purification cost. At the same time, the environment pollution will also be protected to a considerable extent. This operational measure is quite effective and useful specially where high TDS water is demineralized only by single bed ion-exchangers. In such case, the water treatment plant is very often found to suffer from both production quality and quantity in addition to carrying out of random and restless regenerations. Proper reuses of the aforesaid wash water effluents of the Anion and MB units excellently minimizes the difficulties experienced in practice. This paper contains the utilities and techniques of reuses of the different kinds of waste effluents of the industrial water treatment plant in addition to the specific reuses of the post-regeneration wash waters of the Anion and MB ion-exchanger units.

  • PDF

Instability of a Two-Phase Loop Thermosyphon

  • Rhi, Seok-Ho
    • Journal of Mechanical Science and Technology
    • /
    • 제16권7호
    • /
    • pp.1019-1028
    • /
    • 2002
  • The instability of two-phase loop thermosyphons was investigated experimentally and analytically. Three orifice type inserts were used to study the effect of change in the pressure drop in the flow channel of the TLT on the flow instability and temperature fluctuation. It is observed that a decrease in the size of the orifice insert from 3.7 mm (no insert) to 0.71 mm drastically reduced the fluctuation of the temperature, especially at the evaporator section of the TLT. With the orifice type insert of 0.71 mm for the TLT, the overall temperature fluctuation was almost completely eliminated, especially at higher power input to the TLT The analysis based on the Kelvin-Helmholtz instability theory seems to predict reasonable well the loop stability state of the TLT with experimentally determined constant factors.

ATM망의 비연결형 서버를 위한 신경망 연상메모리 ASIC 설계 (ASIC design of neural network CAM for connectionless serverof ATM network)

  • 최석준;박형근;김환용;백덕수
    • 전자공학회논문지C
    • /
    • 제35C권4호
    • /
    • pp.60-68
    • /
    • 1998
  • In this paper, content addressable momory(CAM) using neural network algorithm is proposed to decrease cell loss and process the large amount of data in streaming mode connectionless server at high speed. To overcome problems of area and power dissipation in look-up table using conventional CAM, the proposed neural network CAM is designed to increase linearly address storage bit about increase of address input bit. Its design and imulation is performed by using VHDL and Compass Tool. Also, its layout is performed by using chip compiler, cell-base P&R tool of compass, in 0.8 .mu.m design rule environment.

  • PDF

루프형 2상 유동 열사이폰의 유동 불안정에 관한 실험적 연구 (Experimental Study on Instability of Two-Phase Loop Thermosyphon)

  • 이석호
    • 설비공학논문집
    • /
    • 제14권5호
    • /
    • pp.408-414
    • /
    • 2002
  • The instability of two-phase loop thermosyphons (TLTs) was investigated experimentally. Three orifice type inserts were used to study the effect of change in the pressure drop in the flow channel of the TLT on the flow instability and temperature fluctuation. It is observed that a decrease in the size of the orifice insert from 3.7mm (no insert) to 0.71mm drastically reduced the fluctuation of the temperature, especially at the evaporator section of the TLT With the orifice type insert of 0.71 mm for the TLT, the overall temperature fluctuation was almost completely eliminated, especially at higher power input to the TLT.

MRAS를 이용한 유도전동기의 파라미터 온라인 추정에 관한 연구 (A Study on Parameter On-line Estimation of Induction Motor using MRAS)

  • 윤인식;변성훈;김경서
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.188-191
    • /
    • 2002
  • This paper presents a method for on-line estimation of rotor time constant of induction motor. The proposed method applies a model reference adaptive system(MRAS) using rotor flux vector. The MRAS consists of two independent observers to estimate the rotor flux vector; one based on voltage equations of rotor flux vector, the other based on current equations of them. The MRAS utilizes concept of auxiliary variables to normalize observer output and decrease high-frequency components of its input. Experimental results verify the validity and usefulness of proposed method

  • PDF

LPG 재응축기용 순티타늄 박판의 Nd:YAG 레이저 용접성(I) - 순티타늄의 물성과 용접변수 - (Weldability of Pure Titanium Thin plate for LPG Re-Condenser by Nd:YAG Laser - Physical Constant and Welding Parameter -)

  • 김종도;곽명섭;이창제;김창수
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2007년 추계학술발표대회 개요집
    • /
    • pp.363-365
    • /
    • 2007
  • Titanium and its alloys have excellent corrosion resistance, high strength to weight ratios and high temperature creep properties, which make them using many various fields of application. Responding to these needs, welding processes for titanium are also being used including TIG, MIG, resistance welding, plasma arc welding, diffusion welding, electron beam welding and laser welding. In this study, It is possible to get sound beads without humping bead and spatter with the decrease of peak power according to increase of pulse width and change of welding speed for heat input control at pulsed Nd:YAG laser welding of titanium plates for Lap welding.

  • PDF

고주파 유압시스템에서 감치장치와 축압기에 의한 맥동 충격파 감쇄특성에 대한 연구 (Research for the Pulsating Pressure Characteristics by a Damper and an Accumulator in the High Frequency Hydraulic System)

  • 김양수;김재수;노형운
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.641-647
    • /
    • 2004
  • Characteristics of the high frequency pulsatile flow have been investigated experimentally to understand the flow phenomena in the hydraulic system. The accumulator in high frequency hydraulic system but that is not effective all frequency zone. Therefore, a hydraulic damper used with accumulator is suggested to reduce the high frequency pulsatile where the accumulator is not effective. The pulsating pressure obtained by Pressure measurement system are analyzed to power spectral density distribution. According to the variations of pump input pressure and actuator acceleration frequency, the pressure is measured with or without an accumulator or pulsatile damper The amplitude of pressure with damper is very lower than those without accumulator or damper due to absorbing function of damper. As the frequency of actuator acceleration is increased, the effect of damper becomes very important to decrease the amplitude of pulsatile Pressure waveform with high frequencies.

  • PDF

수평채널 밑면에 부착된 단일 발열모듈에서 채널높이의 변화에 따른 냉각특성 연구 (The Study about Cooling Effect of a Heated module in a Horizontal Channel with a Variation of Channel Height)

  • 이진호;유갑종;장준영;김병하
    • 설비공학논문집
    • /
    • 제13권5호
    • /
    • pp.348-355
    • /
    • 2001
  • The coupled conduction and convection heat transfer from a protruding heated module in a horizontal channel with a variation of channel height is experimentally investigated. The input power to the module is 3, 7W and thermal resistance of module support is 0.06 , 1.03 and 158K/W. the Reynolds number ranged from 350 to 4500 corresponding to the inlet velocity(0.4~1.3 m/s) and channel height(11~35 mm). The results were obtained that the decrease of thermal resistance of module support reduces the module temperature by redistributing the heat flux and the overall thermal resistance of the module. In the study the effect of channel height is very significant in the adiabatic condition, but negligible in the conjugate condition. Finally, correlations for Nusselt number and $Q_B$/Q with a variation of Reynolds number were developed respectively.

  • PDF