• Title/Summary/Keyword: Input concentration

Search Result 679, Processing Time 0.027 seconds

Characteristics of Fluorescent Discharge Lamp Type Ozonizer for Environment Improvement (환경개선을 위한 형광방전등형 오존발생기의 특성)

  • Park, Yong-Gwon;Lee, Sang-Geun;Jeon, Byeong-Jun;Song, Hyeon-Jik;Lee, Gwang-Sik;Ha, Jang-Ho
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.10
    • /
    • pp.500-505
    • /
    • 2002
  • In this paper, fluorescent discharge type ozonizer has been designed and manufactured. Ozone discharge and generation characteristics have been investigated in accordance with a sort of internal electrodes, output voltage of power supply, air flow rate and discharge power. Air has been used as the supplied gas of the ozonizer In this paper, when disuse fluorescent lamp was used as an internal electrode. Air flow rate was varied from 2[1/min] to 10[1/min]. The maximum ozone concentration and yield were 3495[ppm] and 23.4[g/kWh] respectively at 2[1/min] air flow rate and 35.2[W] input power. Illumination was appeared as 5[lx] within 15[cm] from external electrode. Whorl fluorescent discharge type ozonizer was used, air flow rate was also varied from 2[1/min] to 10[1/min]. At this moment, the maximum ozone concentration and yield were 2824[ppm] and 21.7[g/kWh] respectively at 2[1/min] air flow rate and 30.5[W] input power. Illumination was also appeared as 5[lx] within 15[cm] from external electrode like used fluorescent lamp.

Differences of Nutrient Input by Throughfall, Stemflow and Litterfall between Deciduous Forest and Larix kaempferi Plantation in Mt. Joonwang, Kangwon-do (강원도 중왕산 지역 낙엽활엽수림과 낙엽송 조림지에서 수관통과우와 수간류 및 낙엽낙지에 의한 양분 유입의 차이)

  • Jung, Mun-Ho;Lee, Don-Koo;Um, Tae-Won
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.40 no.2
    • /
    • pp.136-144
    • /
    • 2007
  • The objectives of this study were to compare nutrient input by throughfall, stemflow and litterfall and concentration of nutrient in soil water between deciduous forest stand and Larix kaempferi plantation at Mt. Joongwang, Pyongchang-gun, Gangwon-do. The amount of rainfall interception during study period in deciduous forest stand and L. kaempferi plantation was 12% and 36%, respectively. Concentrations of cation ($Na^+$, $Mg^{2+}$, $K^+$ and $Ca^{2+}$) in throughfall were not different, while concentration of $Cl^-$ in stemflow was higher in L. kaempferi plantation. The results indicated that annual nutrient inputs by rainfall with the exception of $Cl^-$ were significantly greater in deciduous forest stand. In soil water, concentrations of anion ($Cl^-$, $NO_3{^-}$ and $SO{_4}^{2-}$) in A-layer, and $Ca^{2+}$ and $Cl^-$ in B-layer were higher in L. kaempferi plantation. Litterfall input during study period was $2,589kg\;ha^{-1}$ in deciduous forest stand and $1,046kg\;ha^{-1}$ in L. kaempferi plantation. Concentration of N was higher in L. kaempferi plantation, while N input from litterfall was greater in the deciduous forest stand ($36.81kg\;ha^{-1}yr^{-1}$) than L. kaempferi plantation ($16.16kg\;ha^{-1}yr^{-1}$). $Na^+$, $Mg^{2+}$, $K^+$ and $Ca^{2+}$ in litterfall collected from deciduous forest stand were found to be higher than those from the L. kaempferi plantation. Also, input of those were greater in deciduous forest stand. Thus, total nutrient input by throughfall, stemflow and litterfall was greater in deciduous forest stand than L. kaempferi plantation, significantly.

A Study on Removal of NOx by Low Temperature Plasma (저온플라즈마에 의한 질소산화물의 제거에 관한 연구)

  • Park, Hei-Jae;Lee, Nae-Woo;Choi, Jae-Wook;Lim, Woo-Sub
    • Korean Chemical Engineering Research
    • /
    • v.48 no.4
    • /
    • pp.540-543
    • /
    • 2010
  • In this study, we made low temperature plasma reactor in order to treat safely $NO_x$ which included in the gas. We investigated experimently and inspected efficiency characteristics of equipment about flow rate of reactant material and discharge input power which supplied into reactor. As a reaction gas, by using mixture gas of $NO/N_2$ and $N_2/O_2$, we setted up initial NO concentration and supplied the speed of a current to 1~4 l/min. When the amount of flow increased, reduction rate of NO was low. Also when discharge input power was high, decomposition of NO was easy. Also the longer delay time of reaction material and the higher discharge input power was, the higher decomposition energy efficiency was. And when the amount of flow was much, and the more discharge input power increased, the more ozone generated.

Comparison of Fermentation Characteristics of Korean Traditional Alcoholic Beverages Prepared by Different Brewing Methods and Their Quality Changes after Aging (전통주의 제조방법별 발효 특성 및 숙성후 품질변화 비교)

  • Kim, In-Ho;Park, Wan-Soo;Koo, Young-Jo
    • Journal of the Korean Society of Food Culture
    • /
    • v.11 no.4
    • /
    • pp.497-506
    • /
    • 1996
  • Fermentation characteristics and quality changes of the typical Korean traditional alcoholic beverages (Kwahaju, Sokokju, Baikhaju, Samhaeju and Hosanchun) were investigated during fermentation and after aging, respectively. They were prepared by their own brewing methods with respect to the same contents of rice and Nuruk (Korean-style bran koji). The consumed total sugar content of the alcoholic beverages (Sokokju, Baikhaju, Samhaeju and Hosanchun) which were brewed with the multiple input steps of seed mash and raw material (ABMIS) was higher than that of the alcoholic beverage (Kwahaju) which was brewed with the single input step (ABSIS). The pH values of all the beverages were similar and were ranged from 3.2 to 3.6. The acidity of ABMIS were lower than that of ABSIS, but alcohol concentration of ABMIS were higher. The fermentation period of the alcoholic beverages with triple input steps was the longest among them. The inner temperature and microbial growth in all the beverages increased at each of input steps of the raw materials. Fusel oil content of ABMIS was lower than that of ABSIS. Major components of the fusel oil were iso-amyl alcohol, iso-butanol, n-propanol, ethyl acetate and acetaldehyde, and its minor components were methanol and n-butanol. The results on quality changes of the alcoholic beverages after aging showed increase of alcohol in ABMIS, but decrease of sugar and acidity. Fusel oil contents of Kwahaju and Samhaeju decreased to be ranged from 3.1% to 13.9% after aging, but those of Sokokju, Baikhaju and Hosanchun increased to be ranged from 10.9% to 23.0%. Sensory evaluation of ABMIS showed better scores than that of ABSIS. It was suggested that the brewing method with multiple input steps of seed mash and raw material was one of the methods to increase fermentation efficiency for brewing the Korean traditional alcoholic beverages.

  • PDF

Spatiotemporal Resolution Enhancement of PM10 Concentration Data Using Satellite Image and Sensor Data in Deep Learning (위성 영상과 관측 센서 데이터를 이용한 PM10농도 데이터의 시공간 해상도 향상 딥러닝 모델 설계)

  • Baek, Chang-Sun;Yom, Jae-Hong
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.37 no.6
    • /
    • pp.517-523
    • /
    • 2019
  • PM10 concentration is a spatiotemporal phenomenta and capturing data for such continuous phenomena is a difficult task. This study designed a model that enhances spatiotemporal resolution of PM10 concentration levels using satellite imagery, atmospheric and meteorological sensor data, and multiple deep learning models. The designed deep learning model was trained using input data whose factors may affect concentration of PM10 such as meteorological conditions and land-use. Using this model, PM10 images having 15 minute temporal resolution and 30m×30m spatial resolution were produced with only atmospheric and meteorological data.

Study on the Application Limits and Sensitivity Analysis for the Parameters of Time of Concentration (도달시간 산정공식의 입력변수 적용범위 및 민감도 분석)

  • 김선주;강상진;이광야;박재흥
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.42 no.6
    • /
    • pp.72-82
    • /
    • 2000
  • Many lot of books introduce the methods to calculate the time of concentration, and these are described as various forms of formulas. There are few formulas appropriate for our basin characteristics Therefone, there are problems to make excessive or less estimation when these formulas are used. To solve these problems, comparison of formulas and sensitivity analysis for them were made with converting parameters. Finally, Time of concentration was estimated to derive Application limits for 3 watersheds by standardized formulas. In the case of input parameters analysis, SCS formula has the highest value by the length, Kerby by the height and SCS by the slope, respectively, while Kraven formula has the lowest value among them. Concerning the relative sensitivity by Taylor series, the time of concentration showed the constant effect while increasing of the length and slope, and the length was more sensitive than the slope in parameters. Finally the standardization formula developed in this study was applied to derive application limits for 3 watersheds(total 17 subbasins). In this case, Rziha(8 subbasins) and SCS(9 subbasins) formulas were the most similar to observed data of total 17 subbasins respectively. Application limits were about 300~500$\textrm{km}^2$ area, 30~60km length and under 0.01 slope for Rziha formula and about 100~200$\textrm{km}^2$ area, 10~30km length, and over 0.01 slope for SCS formula, respectively.

  • PDF

Trace Organic Contaminants in Sediments from Deep-sea Basin near Dokdo, Korea

  • Yim, Un-Hyuk;Oh, Jae-Ryoung;Hong, Sang-Hee;Li, Dong-Hao;Shim, Won-Joon;Choi, Hye-Kyung;Kim, Eun-Soo;Shim, Jae-Hyung
    • Ocean and Polar Research
    • /
    • v.24 no.4
    • /
    • pp.391-398
    • /
    • 2002
  • Trace organic contaminants in deep-sea sediments near Dokdo were analyzed. Total PAMs concentration ranged 14.8-314 ng/g dry weight and high molecular weight PAHs were dominant. The highest PAHs concentration was detected at A19 which located at Ulleung Basin. Most of organochlorines were under detection limit. Among the detected organochlorines, DDT compounds were dominant and followed by HCHs and HCB. Butyltin compounds and most of organophosphorus pesticides were not detected. Vertical distribution of PAHs showed typical sub-surface maximum and decreasing trends depending on depth. The highest PAHs concentration reached 454ng/g. Some organochlorines, DDT, HCH was detected and also showed decreasing trends. Other target organic pollutants were not detected in core sediments. Abnormally high level of PAHs concentration in A19 was discussed and the input sources were inferred to be the transport of sludge derived pollutant dumped at dumping site 'Byung' by deep current.

Retrieval of Dust Backscatter Coefficient using Quartz Raman Channel in Lidar Measurements (석영 라만 채널을 이용한 황사 후방 산란 계수 산출)

  • Noh, Young-Min;Mueller, Detlef;Lee, Han-Lim
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.1
    • /
    • pp.86-93
    • /
    • 2012
  • We present a retrieval method to obtain dust backscatter coefficient from the mixed Asian dust and pollutant layer. In the present study, vertically resolved quartz (silicon dioxide, silica) concentration was calculated using Raman scattering signals from quartz at 546 nm. Dust concentration was obtained based on typical mass percentage of quartz in Asian dust. The highest value of dust concentration at 3.7 km in March 21, 2010 was 22.3 and 10.9 ${\mu}gm^{-3}$ according to the quartz percentage in Asian dust as 65 and 30% based on literature survey, respectively. OPAC (Optical Properties of Aerosol and Clouds) simulations were conducted to calculate dust backscatter coefficient. The retrieved dust concentration was used as an input parameter for the OPAC calculations. Utilization of quartz Raman channel in Lidar measurements is considered useful for distinguishing optical properties of dust and nondust aerosol in the mixing state of Asian dust.

An Effect of Heat Input on Thermal Storage for Horizontal Thermal Storage Tank with Heat pipe (열 파이프용 수평 축열조에서의 열 입력이 축열에 미치는 영향)

  • 최우석;박이동;김철주;황영규
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1995.05a
    • /
    • pp.69-76
    • /
    • 1995
  • The horizontal thermal storage tank with heat pipe which is suitable for the sensible heat storage system is able to store a hot water from the heat source such as heating pad efficiently and to supply a hot water to load rapidly. Therefore Arrangement of heating pad affects thermal flow and thermal storage efficiency. So, if effective arrangement is decided for condition of constant number of heating pad, the more rapid thermal flow effect and higher thermal storage efficiency is obtainable by active heat transfer. In this experiments, number of heating pad is ranged from three, five and nine, and when number of heating pad is constant, arrangement are two types of concentration-type and dispersion-type. As a result, for the case of concentration-type of heating pad, strong entrainment take place in horizontal thermal storage tank with heat pipe by active heat transfer and in the constant number of heating pad, the concentration-type has the higher efficiency with about 5∼6% than the dispersion-type. Therefore, when heating pad is equipted to horizontal thermal storage tank with heat pipe, concentration-type of heating pad is an efficient design in constant number. of heating pad.

  • PDF

Optimal Temperature Tracking Control of a Polymerization Batch Reactor by Adaptive Input-Output Linearization

  • Noh, Kap-Kyun;Dongil Shin;Yoon, En-Sup;Rhee, Hyun-Ku
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.4 no.1
    • /
    • pp.62-74
    • /
    • 2002
  • The tracking of a reference temperature trajectory in a polymerization batch reactor is a common problem and has critical importance because the quality control of a batch reactor is usually achieved by implementing the trajectory precisely. In this study, only energy balances around a reactor are considered as a design model for control synthesis, and material balances describing concentration variations of involved components are treated as unknown disturbances, of which the effects appear as time-varying parameters in the design model. For the synthesis of a tracking controller, a method combining the input-output linearization of a time-variant system with the parameter estimation is proposed. The parameter estimation method provides parameter estimates such that the estimated outputs asymptotically follow the measured outputs in a specified way. Since other unknown external disturbances or uncertainties can be lumped into existing parameters or considered as another separate parameters, the method is useful in practices exposed to diverse uncertainties and disturbances, and the designed controller becomes robust. And the design procedure and setting of tuning parameters are simple and clear due to the resulted linear design equations. The performances and the effectiveness of the proposed method are demonstrated via simulation studies.