• Title/Summary/Keyword: Inorganic membrane

Search Result 305, Processing Time 0.028 seconds

Effect of Membrane Fouling due to Micro-organism Growth on the Membrane Surface (막면 세균 증식에 의한 막오염에 관한 연구)

  • Kim, Hyung Soo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.3
    • /
    • pp.36-41
    • /
    • 1999
  • High quality drinking water can be produced by membrane separation process. A major problem in the current system is a membrane fouling control. In order to investigate membrane fouling due to E.coll removal, lab scale experiment using MF and UF and semi pilot plant experiment using UV radiation or not was performed. AS a result, the possibility of membrane fouling control by repressing of micro-organism on the membrane surface was clearly verified. But it was not clearly verified in this experiment the combined effect with other factors such as Turbidity, organic and inorganic matters.

  • PDF

여과집진막 채용에 의한 소각플랜트의 유해물질 제거 사례

  • 조재수
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1995.03a
    • /
    • pp.135-159
    • /
    • 1995
  • Typical Solid Waste Stream Composition : Paper and paperboard (41%), Glass (8.2%), Metals (8.7%), Plastics (6.5%), Rubers, Leather, Textiles and Wood (8.1%), Food Wastes (7.9%), Yard Wastes (17.9%), Miscellaneous Inorganic Wastes (1.6%).

  • PDF

Multicomponent Nanostructured Materials for Separation Membranes

  • Peinemann, Klaus-Viktor
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.05a
    • /
    • pp.11-11
    • /
    • 2004
  • Under the coordination of GKSS a new European project in the field of membrane development started recently. This project focuses on the development of novel nanostructured materials for selective material transport and separation. Two classes of materials will be developed in this project: nanostructured organic/inorganic hybrid materials and functional self-organized supramolecular copolymers.(omitted)

  • PDF

Liquid Uptake and Methanol Transport Behaviour of PVDF/SPEEK/TiO2 Hybrid Membrane for DMFC (DMFC용 PVDF/SPEEK/TiO2 하이브리드 막의 수분함량과 메탄올 전이현상)

  • You, Sun-Kyung;Kim, Han-Joo;Park, Soo-Gil
    • Journal of the Korean Electrochemical Society
    • /
    • v.8 no.4
    • /
    • pp.177-180
    • /
    • 2005
  • A series of inorganic-organic hybrid membranes were prepared with a systematic variation of titanium dioxide nano particles content. Their liquid uptake, methanol permeability and proton conductivity as a function of inorganic oxide content were investigated. The results obtained show that the inorganic oxide network decreases the proton conductivity and liquid uptake. It is also found that increase in inorganic oxide content leads to decrease of methanol permeability. In terms of the morphology, membranes are homogeneous and exhibit a good adhesion between inorganic domains and the polymer matrix. The properties of the composite membranes are compared with the standard nafion membrane.

Inorganic-organic Hybrid Proton Conductive Membranes Doped with Phosphoric Acid

  • Huang Sheng-Jian;Lee Yong Su;Lee Hoi Kwn;Kang Won Ho
    • Proceedings of the KAIS Fall Conference
    • /
    • 2004.06a
    • /
    • pp.96-99
    • /
    • 2004
  • A new proton conductive inorganic-organic hybrid membrane doped with $H_3PO_4$ was fabricated via sol-gel process wit 3- glycidoxypropyltrimethoxysilane(GPTMS), 3-aminopropyltriethoxysilane(APTES) and tetraethoxysilane(TEOS) asprecursors. Theproto conductivity of about 3.0$\times10^{-3}S/cm$ was obtained at $120^{\circ}C$ under $50\%$ relative humidity (R.H). DTA curves showed that the thermal stability of the membrane is significantly enhanced by the presence of $SiO_2$ framework up to $250^{\circ}C$. SEM and XRD revealed that the gel is microporou and amorphous. The addition of APTES improved the conductivity of the membranes and the effect of the APTES on the conductivity was also discussed in this paper.

  • PDF

Membrane Cayalytic Reactors Comprising Heteropoly Acid Catalysts and Polymer Membranes (12-텅스토인산 촉매와 고분자막으로 구성된 촉매막반응기)

  • 송인규;김재진;이화영
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1992.04a
    • /
    • pp.35-36
    • /
    • 1992
  • 화학반응이 주로 고온에서 일어나기 때문에 polymer membrane의 화학반응에의 적용은 거의 없었으며, 연구의 대부분은 열적 안정성이 좋은 inorganic membrane reactor에 대하여 이루어져 왔다. 산 및 산화환원 촉매로써의 12-텅스토인산은 반응물의 종류에 따라 특이한 흡착 특성을 보이며, 헤테로폴리산만이 지니는 특징적인 surface, bulk 특성 때문에 바능물의 종류에 따라 반응은 촉매의 surface and/or bulk에서 일어난다. 무기 축합산인 12-텅스토인산이 지니는 또 하나의 특징은 물, 알콜, ether 같이 산소를 포함하는 organic solvent에 매우 잘 녹는다는 사실이다.

  • PDF

Enhancement of Cycle Performance of Lithium Secondary Batteries Based on Nano-Composite Coated PVdF Membrane

  • Ryou, Myung-Hyun;Han, Young-Dal;Lee, Je-Nam;Lee, Dong-Jin;Park, Jung-Ki
    • Journal of the Korean Electrochemical Society
    • /
    • v.11 no.3
    • /
    • pp.190-196
    • /
    • 2008
  • The multilayered membrane for lithium rechargeable batteries based on poly (vinylidene fluoride) (PVdF) is prepared with the coated layer containing nano-sized filler. The prepared membranes were subjected to studies of mechanical strength, morphology, interfacial stability, impedance spectroscopy, ionic conductivity, and cycle performance. The localized inorganic filler in the PVdF composite membrane rendered mechanical strength much reduced because of its low stretching ratio and it results in around half value of the mechanical strength of highly stretched PVdF membrane. In order to achieve high ionic conductivity and interfacial stability without sacrificing high mechanical strength, coating layer with nano-filler was newly introduced to PVdF membrane. The ionic conductivity of the coated membrane was 1.03 mS/cm, and the interface between the coating layer and PVdF membrane was stable when the membrane was immersed into liquid electrolyte. The discharge capacity of the cell based on nano-filler coated PVdF membrane was around 91% of the initial discharge capacity after 250 cycles, which is an improvement in cycle performance compared to the case for the non-coated PVdF membrane.

Possible Uses of Reclaimed Wastewater Effluent Treated Using Birm Filtration Along UF, and Analysis on Membrane Fouling (하수방류수 재이용을 위한 Birm filter + UF 적용시 용도별 사용 가능성 및 막오염 특성)

  • Jung, Jin-Hee;Lee, Seung-Chul;Sung, Nak-Chang;Choi, Young-Ik
    • Journal of Environmental Science International
    • /
    • v.25 no.11
    • /
    • pp.1467-1474
    • /
    • 2016
  • In response to the water shortage problem, continued attempts are being made to secure consistent and reliable water sources. Among various solutions to this problem, wastewater effluent is an easy way to secure the necessary supply, since its annual output is consistent. Furthermore, wastewater effluent has the advantage of being able to serve various purposes, such as cleaning, sprinkling, landscaping, river management, irrigation, and industrial applications. Therefore, this study presents the possible use of reclaimed industrial wastewater treated with Birm filters and a UF membrane, along with an analysis on membrane fouling. The preprocessing stage, part of the reclamation process, used Birm filters to minimize membrane fouling. Since this study did not consider heavy metal levels in the treated water, the analyses did not include the criterion for irrigation water quality. However, the wastewater reclaimed by using Birm filters and a UF membrane met every other requirement for reclaimed water quality standards. This indicated that the treated water could be used for cleaning, channel flow for maintenance, recreational purposes, and industrial applications. The analysis on the fouling of the Birm filter and UF membrane required the study of the composition and recovery rate of the membrane. According to SEM and EDX analyses of the UF membrane, carbon and oxygen ion composition amounted to approximately 57%, whereas inorganic matter was not detected. Furthermore, the difference in the recovery rates of the distressed membrane between acidic and alkaline cleaning was more than ~78%, which indicated that organic rather than inorganic matter contributed to membrane fouling.

Applicability of Temperature Correction Trans-membrane Pressure as a Fouling Index of Membrane Water Treatment Process (막여과 정수처리 공정에서 온도보정차압 식의 파울링 지표로서의 활용성 검토)

  • Kim, Minjae;Lim, Jae-Lim;Lee, Kyung-Hyuk;Lee, Young-Joo;Kim, Suhan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • Temperature correction trans-membrane pressure (TC-TMP) is frequently used as a fouling index in membrane water treatment plants. TC-TMP equation is derived based on an assumption that the total membrane resistance (i.e. the sum of the intrinsic membrane resistance and fouling resistance) is not affected by temperature. This work verified the validity of this assumption using microfiltration (MF) and ultrafiltration (UF) membranes with and without fouling. The foulants used in the work were kaolin (inorganic) and humic acid (organic). The intrinsic resistances of MF and UF membranes remains at constant values regardless of temperature change. When the same amount of foulants were accumulated on the membrane, inorganic fouling resistance with kaolin was constant regardless of temperature change while organic fouling resistance with humic acid decreased at higher temperatures, which means that TC-TMP cannot be used as a fouling index when organic fouling occurs in a real field application. Since TC-TMP underestimates the amount of fouling at higher temperatures, more attention should be necessary in the operation of membrane water treatment plant in a hotter season like summer.