• Title/Summary/Keyword: Innominate artery

Search Result 53, Processing Time 0.021 seconds

Surgical Technique for Korean Artificial Heart(AnyHeart) Implantation Using a Right Thoracotomy Approach (우측 개흉술을 이용한 한국형 인공심장(AnyHeart)의 이식기법)

  • Son. Ho-Sung;Sun, Kyung;Shin, Jae-Seung;Lee, Sung-Ho;Jung, Jae-Seung;Lee, Hye-Won;Kim, Kwang-Taik;Kim, Seung-Chul;Won, Yong-Soon;Min, Byoung-Goo;Kim, Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.35 no.5
    • /
    • pp.329-335
    • /
    • 2002
  • Background: The surgical technique for biventricular assist device(BVAD) implantation has mainly consisted of cannulation procedures. A median sternotomy has been the technique of choice as it gives a surgeon an excellent exposure of the heart. However, considering that most patients require a future sternotomy or already have a previous sternotomy, sternotomy-related complication remains a major concern in BVAD implantation. Based on this consideration as well as the clinical experiences of conventional heart surgery, the authors have hypothesized that the cardiac chambers for BVAD cannulation can be approached from the right side of the heart. The purpose of this studs to develop a novel surgical technique of right thoracotomy for BVAD implantation in an animals study. Material and Method: For last two years, 16 (11 calves, 3 canines, and 2 sheep) out of 30 experimental animals with AnyHeart implantation underwent a right thoracotomy. The device was used as an implantable BVAD in 14 animals, a wearable BVAD in 1, and an implantable LVAD in 1. The chest cavity was entered through the 4th intercostal space or the 5th periosteal bed. As for the BVAD use, a right inflow cannula was inserted into the right atrial free wall and a right outflow cannula was grafted onto the main pulmonary artery. A left inflow cannula was inserted into the interatrial groove and a left outflow cannula was grafted on the innominate artery of the ascending aorta. The connecting tubes were brought out through the thoracotomy wound and connected to the pump located in the subcutaneous pocket at the right flank. Result: Except for the 5 animals for a lilting test or during the early learning curve, all recovered smoothly from the procedures. The inflow drainage allowed the pump output 6.5 L/min at the maximum with 3-3.5 L/min in an average. Of the survivors, there noted no procedure-related mortality or morbidity. Necropsy findings demonstrated the well-positioned cannula tips in the each cardiac chamber

One Stage Total Repair of the Aortic Arch Anomaly using the Regional Perfusion (대동맥궁 이상이 동반된 선천성 심장병에서 국소 순환을 이용한 일차 완전 교정)

  • Jang Woo-Sung;Lim Cheong;Lim Hong-Kook;Min Sun-Kyung;Kwak Jae-Kun;Chung Eui-Seuk;Kim Dong-Jin;Kim Woong-Han
    • Journal of Chest Surgery
    • /
    • v.39 no.6 s.263
    • /
    • pp.434-439
    • /
    • 2006
  • Background: Deep hypothermic circulatory arrest during repair of aortic arch anomalies may induce neurological complications or myocardial injury. So we surveyed if the regional cerebral and myocardial perfusion might eliminate those potential side effects. Material and Method: From March 2000 to December 2004, 62 neonates or infants with aortic arch anomaly underwent one stage biventricular repair using the regional perfusion technique by single surgeon. Preoperative diagnosis of the arch anomaly consisted of coarctation (n=46), interruption of the aorta (n=12), hypoplastic left heart syndrome (n=2) and truncus areteriosus (n=2). Combined anomalies were ventricular septal defect (n=51), TAPVR (n=1), PAPVR (n=1) and atrioventricular septal defect (n=2). Arterial cannula was inserted at the innominate artery. Result: The mean regional perfusion time of brain was $28{\pm}10min$. Operative mortality rates was 0 (0/62). Late death was 1 (1/62) during $11{\pm}7$ months of follow-up. Neurologic complications consisted of transient chorea in 1 case. There was no reoperation associated with arch anolamy. Pulmonary complication associated with arch repair occurred in f case which was managed by aortopexy. Conclusion: One-tage rch repair using the regional profusion is safe and effective in minimizing the neurologic and myocardial complications.

Clinical Utility of Turbo Contrase-Enhanced MR Angiography for the Major Branches of the Aortic Arch (대동맥궁 주요 분지들의 고속 조영증강 자기공명혈관조영술의 임상적 유용성)

  • Su Ok Seong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.96-103
    • /
    • 1998
  • Purpose : To assess the clinical utility of turbo contrast-enhanced magnetic resonance angiography(CE MRA) in the evaluation of the aortic arch and its major branches and to compare the image quality of CE MRA among different coils used. Materials and Methods : Turbo three-phase dynamic CE MRA encompassing aortic arch and its major branches was prospectively performed after manual bolus IV injection of contrast material in 29 patients with suspected cerebrovascular diseases at 1.0T MR unit. the raw data were obtained with 3-D FISH sequence (TR 5.4ms, TE 2.3ms, flip angle 30, slab thickness 80nm, effective slice thickness 4.0mm, matrix size $100{\times}256$, FOV 280mm). Total data acquisition time was 4. to 60 seconds. We subjectively evaluated the imge quality with three-rating scheme : "good" for unequivocal normal finding, "fair" for relatively satisfactory quality to diagnose 'normal' despite intravascular low signal, and "poor" for equivocal diagnosis or non-visualization of the origin or segment of the vessels due to low signal or artifacts which needs catheter angiography. At the level of the carotid bifurcation, it was compared with conventional 2D-TOF MRA image. Overall image quality was also compared visually and quantitatively by measuring signal-to-noise ratios (SNRs) of the ascending aorta, the innominate artery and both common carotid arteries among the three different coils used(CP body array(n=12), CP neck array(n=9), and head-and-neck(n=8). Results : Demonstration of the aortic arch and its major branches was rated as "good" in 55% (16/29) and "fair" in 34%(10/29). At the level of the carotid bifurcation, image quality of turbo CE MRA was same as or better than conventional 2D-TOF MRA in 65% (17/26). Overall image quality and SNR were significantlygreater with CP body array coil than with CP neck array or head-and-neck coil. Conclusions : Turbo CE MRA can be used as a screening exam in the evaluation of the major branches of the aortic arch from their origin to the skull base. Overall imagequality appears to be better with CP body array coil than with CP neck array coil or head-and-neck coil.

  • PDF