• Title/Summary/Keyword: Inner-zone

Search Result 313, Processing Time 0.026 seconds

An Experimental Study on the Combustion Characteristics with Hydrogen Enrichment in a Dump Combustor (수소 혼합에 따른 덤프 연소기내의 연소 특성에 관한 실험적 연구)

  • Kim, Dae-Hee;Hong, Jung-Goo;Shin, Hyun-Dong
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2977-2983
    • /
    • 2008
  • The combustion characteristics of a partially premixed flame in a dump combustor were studied to determine the effects of hydrogen enrichment in propane. Bluff-body was used for flame stabilization. Fuel mixtures containing a hydrogen mole fraction ranging from 0.1 to 0.5 were burnt at ambient pressure within a quartz chamber. Tests were carried out keeping the total reactant flow rate by adjusting the fuel and air flow rates. The fluctuations of pressure were measured by piezoelectric pressure sensor. The instantaneous flame structure and OH chemiluminescence images were described by High-speed Intensified Charged Coupled Device (HICCD) camera and Intensified Charged Coupled Device (ICCD) camera. The present results show that hydrogen enrichment in fuel changed the location of primary reaction zone from inner recirculation zone to turbulent shear layer and pressure signal. The reason is that chemical aspects take precedence over flow aspects in the hydrogen-enriched flame.

  • PDF

Design and Characteristics Analysis of a Novel Single-phase Hybrid SRM for Blender Application

  • Jeong, Kwang-Il;Ahn, Jin-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.1996-2003
    • /
    • 2018
  • In this paper, the design and characteristic analysis of a novel single-phase hybrid switched reluctance motor (HSRM) for the purpose of replacing the universal motor in commercial blenders are presented. The proposed motor is easy to manufacture due to its simple yet robust structure with minimized power switches and no torque dead-zone. Moreover, the proposed HSRM is able to deliver a high starting torque as a requirement for blending hard food or even ice. The stator has permanent magnets (PMs) mounted on its inner surface and the rotor has a wide pole arc and salient poles that contribute to its high starting torque profile and the elimination of the torque dead-zone. Finite element method (FEM) is used to analyze the characteristic of the proposed motor. Finally, the prototype is manufactured and its performance is verified through experiments.

The Change of Vegetation Environment since middle-late Holocene in the lower reaches of Taehwa River, Taehwa-dong, Ulsan-si, Korea (울산 태화강 하류 태화동 홀로세 중·후기 식생환경 변화)

  • Kim, HyeRyung;Yoon, Soon-Ock;Hwang, Sangill
    • Journal of The Geomorphological Association of Korea
    • /
    • v.23 no.2
    • /
    • pp.1-13
    • /
    • 2016
  • This study analyzed pollen compositions in archaeological site on alluvial plain of Taehwa River, Taehwa-dong, Ulsan-si vegetational and environmental change during 6,200~3,000 yr BP. The results consist upward of Pollen Zone I (Inner Bay environment), Pollen Zone II (Quercus-Alnus stage) and Pollen Zone III (Alnus stage). The pollen grains of Fagopyrum and reddish gray silty horizon including artifacts of the Bronze Age suggest that there was cultivation on dry-field around the study site, although it is not sure that there was paddy-field cultivation.

A sutdy on the District Unit Design by Traffic Assignment (교통량 배정을 고려한 지구단위설계에 관한 연구)

  • Jin, Jang-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.4
    • /
    • pp.1880-1888
    • /
    • 2012
  • This study tried to analyze traffic assignment volume by application of land use patterns and transport policies in District Unit Design. It is postulated a Toy network and various scenarios which are combined land use patterns and transport policies for analyzing change of assignment volume. As results, this study shows best District Unit Design technique is the policy that develop mid block and introduction of car free zone to inner 2 way streets. Worst design technique is the policy that introduction of joint car parking to mid block. And also worst design technique to residents who are living in inner block is the policy that just develop only one center zone.

High Dispersion Line Profiles of the Planetary Nebula NGC 6833 and its Implication

  • Lee, Seong-Jae;Hyung, Siek
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.2
    • /
    • pp.73.1-73.1
    • /
    • 2010
  • Using the spectroscopic data secured with the Hamilton Echelle Spectrograph attached to a 3-m telescope at the Lick Observatory, we derived the expansion velocities from various line profiles in the 3600 $\AA$ to 10,000 $\AA$ based on the full width at half maximum and double peak of the high dispersion line profiles. The symmetrical shapes of the permitted line profiles indicate that the permitted line zone is symmetrical e.g., a spherical shell or bipolar + torus structures, which might be evidence of relatively recent ejection from the central star. Most other stronger forbidden lines might be coming from a main shell which appears as a bilateral symmetrical morphology, seen in HST and other ground-based telescopic images. The overall expansion velocities of this main shell structure that are responsible for most lines, seem to show the Hubble type expansion, i.e., accelerating shell. The faster expansion velocities of the permitted OII, NII, NIII and perhaps CII lines that do not suit to the Hubble type expansion, imply the existence of a somewhat smaller inner shell inside the outer main shell. We conclude that the nebular shell consists of a swiftly expanding inner shell and an outer normal shell excited by a central star of about 55,000K. The former compact zone appears to be responsible for the permitted C, N, and O lines while the latter extended shell appears to be responsible for H, He, and forbidden lines. We present some evidence that NGC 6833 be a member of the Galactic halo.

  • PDF

Extraction of Three-Dimensional Hybrid City Model based on Airborne LiDAR and GIS Data for Transportation Noise Mapping (교통소음지도 작성을 위한 3차원 도시모델 구축 : 항공 LiDAR와 GIS DB의 혼용 기반)

  • Park, Taeho;Chun, Bumseok;Chang, Seo Il
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.933-938
    • /
    • 2014
  • The combined method utilizing airborne LiDAR and GIS data is suggested to extract 3-dimensional hybrid city model including roads and buildings. Combining the two types of data is more efficient to estimate the elevations of various types of roads and buildings than using either LiDAR or GIS data only. This method is particularly useful to model the overlapped roads around the so called spaghetti junction. The preliminary model is constructed from the LiDAR data, which can give wrong information around the overlapped parts. And then, the erratic vertex points are detected by imposing maximum vertical grade allowable on the elevated roads. For the purpose of efficiency, the erratic vertex points are corrected through linear interpolation method. To avoid the erratic treatment of the LiDAR data on the facades of buildings 2 meter inner-buffer zone is proposed to efficiently estimate the height of a building. It is validated by the mean value (=5.1%) of differences between estimated elevations on 2 m inner buffer zone and randomly observed building elevations.

  • PDF

On the two phase detonation in carbon laden oxygen : taking into account of inner particle temperature distribution (입자온도 분포를 고려한 탄소입자와 산소에서의 이상폭발현상에 관한 연구)

  • 승성표;백승욱
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.5
    • /
    • pp.1104-1112
    • /
    • 1988
  • In this study the structure of a two phase detonation has been numerically investigated through the assumption of a steady and one-dimensional flow in the suspension of carbon particles and pure oxygen. The bow shock formation in front of carbon particles has been taken into consideration when the relative velocity of gas flow with respect to the particle exceeds the local speed of sound. But its effect was found to be very limited to the induction zone only. Furthermore the interior particle temperature distribution has been considered in this work. It was found that the inner temperature gradient was very steep in the region of high relative velocity. On the while the temperature distribution inside the particle was almost uniform in the region of low relative velocity. Overall, the effect of the interior particle temperature distribution has been significant in the two phase detonation.

A Study on the Leak-Proof of Full Containment Type Prestressed Concrete Structure (완전 밀폐형 PC 구조물의 누설 안전성에 관한 연구)

  • Kim Chung Kyun;Cho Seung Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.4 s.16
    • /
    • pp.85-91
    • /
    • 2001
  • This paper presents safety analysis of LNG leakage in a prestressed concrete outer tank, which is strongly related on the leak checking effects of the PC structure with and without a residual compression zone based on the BS 7777 codes. The full containment type outer tank which is constructed by a prestressed concrete may be destroyed by leaked cryogenic fluids. The FE calculated results show that the total leak checking time of the PC structure with $10\%$ residual compression zone is about 9 days for $-162^{\circ}C$ liquids. But, three primary pumps in an inner tank may operate to send cryogenic fluids for 6 days, which are stored in an inner tank of $140,000m^3$ capacity This means that the prestressed concrete outer tank may be safe for $-162^{\circ}C$ cryogenic fluids leaked from the demolished inner tank.

  • PDF

Evaluation of Corrosion Characteristics on Welding Zone of Leakage SeawaterPipe Welded by Underwater Welding Electrode (수중 용접봉으로 용접한 누수배관 용접부위의 부식 특성 평가)

  • Moon, Kyung-Man;Lee, Sung-Yul;Kim, Yun-Hae;Lee, Myung-Hyoon;Kim, Jin-Gyeong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.8
    • /
    • pp.1240-1247
    • /
    • 2008
  • Leakage trouble on the sea water pipeline in engine room is often resulted from a localized corrosion due to severe corrosive environment caused by both high speed and high pressure of sea water flowing through the inner pipe. In addition, when the ship is in stand-by or emergency condition, underwater welding to control the leakage of sea water from a hole of its pipe is very important in an industrial safety point of view. In this study possibility of underwater welding to control leakage of sea water and corrosion property of its welding zone were investigated with the electrochemical methods by parameters of welding methods and welding electrodes when underwater welding is achieved with a such case that sea water is being leaked out with a height at 50mm from a hole of $2.5mm{\emptyset}$ of test pipe. Corrosion resistance of weld metal zone is better than the base metal and its hardness is higher than that of the base metal. However corrosion potential of weld metal zone showed a negative value than that of the base metal, therefore weld metal zone is preferentially corroded rather than the base metal by performance of galvanic cell due to difference of corrosion potential between weld metal zone and base metal. Eventually it is suggested that leakage of sea water is successfully controlled by underwater welding,

Application of SP and Pole-pole Array Electrical Resistivity Surveys to the Seawater Leakage Problem of the Embankment (방조제 누수지점 탐지를 위한 SP및 단극배열 전기비저항탐사의 적용)

  • 송성호;이규상;김진호;권병두
    • Economic and Environmental Geology
    • /
    • v.33 no.5
    • /
    • pp.417-424
    • /
    • 2000
  • We applied SP monitoring and resistivity surveys using the pole-pole electrode array to seawater leakage problems in the Youngsan estuary dam and the Eoeun embankment to estimate and detect the zone of seawater leakage. The embankment is generally affected by tidal variation and has low resistivity characteristics due to the high saturation of seawater. For this reason, SP monitoring and the pole-pole array resistivity surveys, which are relatively more effective to the conductive media, were carried out to delineate the leakage zones of sea water through the embankment. We checked out electrical conductivity (EC) and temperature variations along the inner part of Youngsan estuary dam to detect the zone of seawater leakage and found that the measured EC value agreed to that of seawater in the leakage zone and the temperature was lower than that of the vicinity of leakage zone. SP monitoring results were coincided with tidal variations at each embankment. At the leakage zones in the Youngsan estuary dam and the Eoeun embankment, SP anomalies are in the range of -60~-85 mV and -20~-50 mV, respectively, and true resistivity values obtained by 2-D inversion are 3~15 ohm-m and below 0.3 ohm-m, respectively. Both SP monitoring and the pole-pole array resistivity method are found to be quite effective for investigation of seawater leakage zones in the embankment.

  • PDF