• Title/Summary/Keyword: Inner power

Search Result 842, Processing Time 0.025 seconds

The Improvement on Insulation Performance of Underground Distribution Power Cables (지중배전케이블 절연성능 향상 방안)

  • Lee, Jae-Bong;Lee, Byung-Sung;Kim, Sang-Joon;Jang, Sang-Ok;Han, Yong-Huei;Oh, Jae-Hyoung
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.497-501
    • /
    • 2004
  • The primary failure causes of underground distribution power cables are water penetration in insulation layer and stress enhancement at inner semi-conductive layer. Accordingly, it is needed to improve the materials and the structure of power cables for extending lifetime and preventing failure. We uses non-flaming PE materials instead of PVC as a covering material and encapsulating structure. We also use super smooth class material as a inner semi-conductive layer. The newly developed cables are improved in AC breakdown voltage after ageing tests.

  • PDF

Design and Analysis of Gerotor with Generalized Shapes for Power-Steering Units (파워 스티어링 유닛용 일반형상 제로터의 설계 및 해석)

  • Jeong, Jae-Tack;Shin, Soo-Sik;Kim, Kap-Tae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.7
    • /
    • pp.891-896
    • /
    • 2010
  • A gerotor is used in power-steering units (PSUs) as well as in hydraulic motors or pumps. The inner rotor is developed on the basis of the shape of the outer rotor tooth, which normally has one arc. The method of generating inner rotor on the basis of a generalized shape of outer rotor is analyzed with a view to improve PSU characteristics. An arc-shaped outer rotor with two curvatures was used in the analysis; design parameters such as the shape and curvature of the inner rotor, the flow rate of the gerotor, the position of contact point, and slip velocity are calculated, and these results are shown. This analysis enables us to develop a new design of compact PSUs.

A Study on Sintering Properties of a SiC-ZrB2 Composite According to Mold Size of SPS Through Computer Simulation (컴퓨터 시뮬레이션에 의한 SPS의 몰드크기에 따른 SiC-ZrB2 복합체의 소결특성 연구)

  • Shin, Yong-Deok;Lee, Jung-Hoon;Jin, Beom-Soo;Kang, Myeong-Kyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.7
    • /
    • pp.988-991
    • /
    • 2012
  • The computer simulation was performed to confirm distribution of current and power density according to inner diameter of graphite mold of SPS(Spark Plasma Sintering). When the inner diameters of a graphite mold are varied $10mm{\Phi}$, $20mm{\Phi}$, $30mm{\Phi}$ and $40mm{\Phi}$, the more the inner diameter of graphite mold is decreased, the more the current density of punch section is increased. Because the electrical resistivity of the SiC-$ZrB_2$ specimen section($7.77{\times}10^{-4}{\Omega}{\cdot}cm$) was lower than the electrical resistivity($6.00{\times}10^{-3}{\Omega}{\cdot}cm$) of graphite section, the current density and power density of specimen section was higher than those of graphite section. It is considered that a SiC-$ZrB_2$ composite is sintered by more Joule heat of specimen section than that of mold and punch section. The current and power density distribution of a SiC-$ZrB_2$ composite can be predicted through computer simulation when SPS is conducted, and an electrical resistivity of the SiC-$ZrB_2$ composite is main element of SPS.

Inner disk properties of a Class I young stellar object revealed by IGRINS

  • Lyo, A-Ran;Kim, Jongsoo;Byun, Do-Young;Kang, Jihyun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.2
    • /
    • pp.35.4-36
    • /
    • 2015
  • Gaseous inner disks are the main controller of the final structure of planetary systems as well as the building place of planets, especially of terrestrial planets. However, the inner disk of <5AU is still difficult to be spatially resolved even at the closest star forming regions. Resolving velocity structure in the disk with high resolution infrared spectroscopic study is the best approach to study the inner disk at this moment. Here, we present the IGRINS (Immersion GRating INfrared Spectrometer) result of the Class I young stellar object, ESO Ha 279a, in the Serpens molecular cloud region. IGRINS has a resolving power of R=40,000, corresponding to the velocity resolution of 7 km/s at K-band, which is perfect to study the hot inner disk structure. We report that NaI and CO overtone emission lines are indeed good tracers of the rotating inner warm disk tracing from ~0.04 to ~7AU of this source. We also report the disk properties using other emission lines.

  • PDF

CFD ANALYSIS OF FLOW CHANNEL BLOCKAGE IN DUAL-COOLED FUEL FOR PRESSURIZED WATER REACTOR (가압경수로 이중냉각핵연료의 내측수로 막힘에 대한 전산유체역학 해석)

  • In, W.K.;Shin, C.B.;Park, J.Y.;Oh, D.S.;Lee, C.Y.;Chun, T.H.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.269-274
    • /
    • 2011
  • A CFD analysis was performed to examine the inner channel blockage of dual-cooled fuel which has being developed for the power uprate of a pressurized water reactor (PWR). The dual-cooled fuel consists of an annular fuel pellet($UO_2$) and dual claddings as well as internal and external cooling channels. The dual-cooled annular fuel is different from a conventional solid 려el by employing an internal cooling channel for each fuel pellet as well as an external cooling channel. One of the key issues is the hypothetical event of inner channel blockage because the inner channel is an isolated flow channel without the coolant mixing between the neighboring flow channels. The inner channel blockage could cause the Departure from Nucleate Boiling (DNB) in the inner channel that eventually causes a fuel failure. This paper presents the CFD simulation of the flow through the side holes of the bottom end plug for the complete entrance blockage of the inner channel. Since the amount of coolant supply to the inner channel depends on largely the pressure loss at the side hole, the pressure loss coefficient of the side hole was estimated by the CFD analysis. The CFD prediction of the loss coefficient showed a reasonable agreement with an experimental data for the complete blockage of both the inner channel entrance and the outer channel. The CFD predictions also showed the decrease of the loss coefficient as the outer channel blockage increases.

  • PDF

SED MODELING FOR CLASS 0 PROTOSTAR L1527 IRS

  • Baek, Giseon;Lee, Jeong-Eun;Lee, Seokho
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.2
    • /
    • pp.42.1-42.1
    • /
    • 2015
  • We model the Spectral Energy Distribution (SED) of Class 0 protostar L1527 IRS using a radiative transfer code RADMC-3D. In addition to the photometry data from literatures, we include the Herschel/PACS data which well covers the far-infrared SED peak of L1527 IRS, providing precise constraints to the density structure and other physical properties of its circumstellar envelope. Previously, Tobin et al. (2013) presented a dust continuum modeling results using a rotating and infalling envelope (Terebey and Shu, & Cassen 1984 ; TSC envelope), which originally describes a power-law density profile (${\rho}{\propto}r-{\alpha}$) with the power-law index (${\alpha}$) of 1.5. However, we find that Herschel/PACS data are better fitted with a shallower power-law density profile. This smaller power-law might be attributed to a inner envelope. Thus, we fit the SED of L1527 IRS with a Bonnor-Ebert sphere, which is a combination of the inner flat-topped and the outer power-law (${\alpha}=2$) density profiles. This Bonnor-Ebert sphere is often used to explain the density profile of prestellar cores, which is considered the earliest stages of star formation. The well-fitted SED with a Bonnor-Ebert sphere suggests that L1527 IRS might have collapsed from a Bonnor-Ebert sphere rather than a singular isothermal sphere.

  • PDF

Laser Peening Application for PWR Power Plants (비등수형 원자로 발전소에의 레이저 피닝 적용기술)

  • Kim, Jong-Do;SANO, Yuji
    • Journal of Welding and Joining
    • /
    • v.34 no.5
    • /
    • pp.13-18
    • /
    • 2016
  • Toshiba has developed a laser peening system for PWRs(pressurized water reactors) as well after the one for BWRs(boiling water reactors), and applied it for BMI(bottom-mounted instrumentation) nozzles, core deluge line nozzles and primary water inlet nozzles of Ikata Unit 1 and 2 of Shikoku Electric Power Company since 2004, which are Japanese operating PWR power plants. Laser pulses were delivered through twin optical fibers and irradiated on two portions in parallel to reduce operation time. For BMI nozzles, we developed a tiny irradiation head for small tubes and we peened the inner surface around J-groove welds after laser ultrasonic testing (LUT) as the remote inspection, and we peened the outer surface and the weld for Ikata Unit 2 supplementary. For core deluge line nozzles and primary water inlet nozzles, we peened the inner surface of the dissimilar metal welding, which is of nickel base alloy, joining a safe end and a low alloy metal nozzle. In this paper, the development and the actual application of the laser peening system for PWR power plants will be described.

Calculation of Maximum Allowabel Temperature Difference for Life Design of Valve Casings for Steam Turbines of Fossil Power Plants (화력발전용 증기터빈 밸브 케이싱의 수명 설계를 위한 최대허용온도차 계산)

  • Ha, Joon-Wook;Kim, Tae-Woan;Lee, Boo-Youn
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.8
    • /
    • pp.46-52
    • /
    • 1999
  • Large valves for steam turbines of fossil power plants are exposed to a severe mechanical and thermal loading resulting from steam with high pressure and high temperature. Valve casings are designed to withstand such a loading. During the operation of a plant, temperatures at inner and outer surface of the casings are measured and steam flow is controlled so that the measured difference is lower than the maximum allowable value determined in the design stage. In this paper, a method is presented to calculate the maximum allowable temperature difference at the inner and outer surface of valve casings for steam turbines of fossil power plants. The finite element method is used to analyze distribution of temperature and stresses of a casing under the operating condition. Low cycle fatigue and creep rupture are taken into consideration to determine the maximum allowable temperature difference. The method can be usefully applied in the design stage of the large valves for the steam turbines, contributing to safe and reliable operation of the fossil power plants.

  • PDF

Experimental Simulation of Iron Oxide Formation on Low Alloy Steel Evaporator Tubes for Power Plant in the Presence of Iron Ions

  • Choi, Mi-Hwa;Rhee, Choong-Kyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.11
    • /
    • pp.2577-2583
    • /
    • 2009
  • Presented are the formation of iron oxide layers on evaporator tubes in an actual fossil power plant operated under all volatile treatment (AVT) condition and an experimental simulation of iron oxide formation in the presence of ferrous and ferric ions. After actual operations for 12781 and 36326 hr in the power plant, two iron oxide layers of magnetite on the evaporator tubes were found: a continuous inner layer and a porous outer layer. The experimental simulation (i.e., artificial corrosion in the presence of ferrous and ferric ions at 100 ppm level for 100 hr) reveals that ferrous ions turn the continuous inner oxide layer on tube metal to cracks and pores, while ferric ions facilitate the production of porous outer oxide layer consisting of large crystallites. Based on a comparison of the oxide layers produced in the experimental simulation with those observed on the actually used tubes, we propose possible routes for oxid layer formation schematically. In addition, the limits of the proposed corrosion routes are discussed in detail.

Exergetic design and analysis of a nuclear SMR reactor tetrageneration (combined water, heat, power, and chemicals) with designed PCM energy storage and a CO2 gas turbine inner cycle

  • Norouzi, Nima;Fani, Maryam;Talebi, Saeed
    • Nuclear Engineering and Technology
    • /
    • v.53 no.2
    • /
    • pp.677-687
    • /
    • 2021
  • The tendency to renewables is one of the consequences of changing attitudes towards energy issues. As a result, solar energy, which is the leader among renewable energies based on availability and potential, plays a crucial role in full filing global needs. Significant problems with the solar thermal power plants (STPP) are the operation time, which is limited by daylight and is approximately half of the power plants with fossil fuels, and the capital cost. Exergy analysis survey of STPP hybrid with PCM storage carried out using Engineering Equation Solver (EES) program with genetic algorithm (GA) for three different scenarios, based on eight decision variables, which led us to decrease final product cost (electricity) in optimized scenario up to 30% compare to base case scenario from 28.99 $/kWh to 20.27 $/kWh for the case study. Also, in the optimal third scenario of this plant, the inner carbon dioxide gas cycle produces 1200 kW power with a thermal efficiency of 59% and also 1000 m3/h water with an exergy efficiency of 23.4% and 79.70 kg/h with an overall exergy efficiency of 34% is produced in the tetrageneration plant.