• Title/Summary/Keyword: Inner length

Search Result 760, Processing Time 0.039 seconds

The Effect of the diameter and anastomotic angles on the compliance and the stress distribution of the end-to-side anastomosis (직경 및 문합각도가 단측 문합의 컴플라이언스 및 응력분포에 미치는 영향)

  • Han, G.J.;Kim, Y.H.;Kim, H.S.;Ann, S.C.;Jang, W.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.334-337
    • /
    • 1997
  • Von Mises stress and compliance distribution was evaluated using a finite element analysis on the end-to-side anastomosis of an artery with length of $20\sim24mm$, inner diameter of 4mm, thickness of 0.5mm and a PTFE graft with length of 10mm, inner diameter of 2mm, thickness of 0.2mm when the anastomotic angle was taken from $30^{\circ}\sim90^{\circ}$ in every $10^{\circ}$ and the diameter ratio from $0.1\sim1$ in every 0.1. The inner pressure of $1330dyne/mm^2$ was applied inside the 2 conduits. It was found that the compliance whose magnitude is larger on the acute angle anastomotic side than on the acute angle side became larger as the anastomotic angle became smaller and the diameter ratio larger and that the equivalent stress on the acute angle anastomotic side was larger than that on the abtuse angle side and became larger as the anastomotic angle and the diameter ratio became larger.

  • PDF

The Effect of the Diameter and Anastomotic Angle on the Compliance and the Stress Distribution of the End-to-side Anastomosis. (직경 및 문합각도가 단측 문합의 컴플라이언스 및 응력분포에 미치는 영향)

  • 한근조;김영호
    • Journal of Biomedical Engineering Research
    • /
    • v.19 no.2
    • /
    • pp.183-188
    • /
    • 1998
  • Von Mises stress and compliance distribution was evaluated using a finite element analysis on the end-to-side anastomosis of an artery with length of 20-24mm, inner diameter of 4mm, thickness of 0.5mm and a PTFE graft with length of 10mm, inner diameter of 2mm, thickness of 0.2mm when the anastomotic angle was taken from 30$^{\circ}$~90$^{\circ}$ in every 10$^{\circ}$ and the diameter ratio from 0.1-1 in every 0.1. The inner pressure of 1330 dyne/$\textrm{mm}^2$ was applied inside the 2 conduits. It was found that the compliance whose magnitude is larger on the acute angle anastomotic side than on the abtuse angle side became larger as the anastomotic angle became smaller and the diameter ratio larger and that the equivalent stress on the acute angle anastomotic side was larger than that on the abtuse angle side and became larger as the anastomotic angle and the diameter ratio became larger.

  • PDF

An Ergonomic Study on Functional Utility of Movement in Sleeves (소매의 동작기능성에 관한 인간공학적 연구)

  • 최해주
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.19 no.5
    • /
    • pp.826-841
    • /
    • 1995
  • This study is concerned with the functional utility of movement in sleeve from an ergonomic viewpoint. Experiments were carried out which include 43 upper extremity segments, 21 motions and 35 female subjects. The major conclusions of the study are. 1. The expansion rate of upper extremity was higher in length than in circumference mesurements. The amounts of expansion were, especially high (more than 60mm) for inner arm length, axillary arm circumference, and outer arm length. Therefore, a lot of ease is necessary for these parts. On the other hand, armhole circumference, forearm circumference, and wrist circumference had low rates of expansion. The sleeve cap length was also contracted in all motions. 2. The expansion rate and the range of expansion and contraction were higher in the upper arm than in the forearm. The main points of expansion were the axillary and elbow parts. The segment of maximum expansi (rate of 44.8%) was Iii of axillary parts. As the body surface expands mainly in some segments, it is desirable to allow ease to the main segments of expansion. 3. In a basic sleeve, necessary ease was lacking in the measurements for outer arm length and axillary arm circumference, while it was too large in armhole circumference, forearm circumference, wrist circumference, and sleeve cap length. Therefore, a basic sleeve is inadequate as a functional sleeve for hard work in point of functional utility of movement. Wider application of these findings would lead to an improvement in the comfort of workers.

  • PDF

A Study on Performance of Dual Swirl Injector with Different Recess Length (이중 스월 분사기의 Recess 길이에 따른 성능 평가)

  • 김태한;조남춘;금영탁
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.7 no.2
    • /
    • pp.62-69
    • /
    • 2003
  • Swirl injectors have the advantage of stable combustion, high efficiency, and insensibility to variable O/F ratio. Recess length is the length from outer orifice tip to inner orifice tip. It is the very important variable of performance of swirl type injector Recess length have influence on collision, mixing, spray, and combustion of propellants. This study investigated on the engine performance with the change of recess length through CFD, cold flow test, and combustion test. In result, we could confirm the change of engine performance with the change of recess length. And we found that performance forecast process through CFD, cold flow test is the right process through combustion test.

Structural Properties of Naked and Covered Barley Starches (쌀보리와 겉보리 전분의 분자구조적 성질)

  • Choi, Jun-Bok;Lee, Shin-Young
    • Korean Journal of Food Science and Technology
    • /
    • v.21 no.1
    • /
    • pp.80-85
    • /
    • 1989
  • The structural properties of covered and naked barley starches and those components were investigated. ${\beta}-amylosis\;limit(%)$ of covered and naked barley starches were 58.6 and 56.3%, respectively and those of their amyloses and amylopectins were 87.0, 77.7, 57.6 and 52.0%, respectively. The ratios of outer chain length ${\overline{OCL}}$ and inner chain length${\overline{ICL}}$ for amylopectins of covered and naked barley were about 2.2:1 and 2.0:1, respectively. The elution curves by Sephadex G-75 after debranching starches with pullulanase were similar patterns for two starches and yielded two peaks consisting of amylose component${\overline{dp}}>55$ and bimodal amylopectin components of ${\overline{dp}_(35-45)$ and ${\overline{dp}}(10-20)$ hydrolysates. Also, hydrolysis products by sequential hydrolysis with pullulanase and ${\beta}-amylase$ contained 0.03-0.5% non-hydrolyzed peak components of ${\overline{dp}}>55$. The elution profiles of ${\beta}-amylase$ hydrolysates yielded two peaks consisting of the inner components${\overline{dp}}>55$ and the outer chain components of amylopectin${\overline{dp}}>10$ regardless of samples. However, ${\overline{dp}}$ distributions of ${\overline{dp}>55}$ hydrolysates exhibited the significant differences due to the varieties.

  • PDF

A New Record of Tarsonemid Mite, Stenotarsonemus spinki (Acari, Tarsonemidae) and Its Damage on Rice in Korea (한국 미기록 벼먼지응애, Steneotarsonemus spinki와 그 피해)

  • 조명래;김덕수;임대준;나승용;임명순
    • Korean journal of applied entomology
    • /
    • v.38 no.2
    • /
    • pp.157-164
    • /
    • 1999
  • A tarsonemid mite. Stet~rotc~r.sot~rrrs~puin.sk i Smiley 1967. is an important rice pest in major rice producing countries of Thailand. Philippine. China, and Taiwan. S. spinki was found first time in Korea from rice grown in environment controlled greenhouse. Rice fed by the mite showed damage symptoms of deformed panicles and inflorescence, lesions on the inner surface of leaf sheath, and browning of rice hulls. Females of S. .spi~lkwi as 263.0 pni (246.5-284.6f 12.2) in body length and 92.4 pm (79.5- 104.9 t 7.6) in body width. Body was elongate and broadest in region of hysterosoma. Body color was pale brown. Legs were robust except for the legs IV which were typical tarsonemid female legs terminating in a whiplike seta two times the length of the leg. Male of S. spir~kiw as 196.5 pm ( 176.5-222.8 + 15.8) in body length and 109.3 ym (98.6- 1 17.7 + 6.4) in body width. Anterior ends of apodemes 111 were extended further than apodemes IV. Femur IV had large inner median lateral flange. and inner anterior and outer median setae were short about equal length. Tarsal claw was stout and curved ventrally.

  • PDF

Electromagnetic characteristics of non-inductively wound coil according to gap length between layers (무유도 초전도 한류 코일의 층간 간격에 따른 전자기적 특성 연구)

  • Yang, Seong-Eun;Park, Dong-Keun;Chang, Ki-Sung;Kim, Young-Jae;Ahn, Min-Cheol;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.822_823
    • /
    • 2009
  • Superconducting fault current limiters (SFCLs) provide one of the most effective solutions to cope with enormous increase of fault current level. The 13.2 kV/ 630 A class resistive SFCL using coated conductor (CC) was developed and its short-circuit test was successful. Successful commercialization of the SFCL requires that no loss is produced by impedance of limiting coil during normal operation. Since the limiting coil consists of inner layer and outer layer, gap length between the layers is an important parameter to analyze the electromagnetic characteristics of coil. This paper deals with the electromagnetic characteristics of coil according to gap length through the simulation and analysis in comparison with experiment results.

  • PDF

Two New Species of Echiuricopus n. gen. (Copepoda, Poecilostomatoida) Associated with Echiurans from the Yellow Sea

  • Kim, Il-Hoi
    • Animal Systematics, Evolution and Diversity
    • /
    • v.32 no.1
    • /
    • pp.9-20
    • /
    • 2016
  • Two new species of poecilostomatoid copepods associated with echiurans are described from an intertidal mud flat in the Yellow Sea. A new genus Echiuricopus is created to accommodate two new species, E. aprilis and E. tenuipes. Major differences between the two new species are displayed in body length, length of caudal ramus seta I, length/width ratio of leg 5 exopod, and armature of the first antennular segment. Echiuricopus n. gen. is closely related to the genus Goidelia Embleton, 1901, but is distinguished from the latter chiefly by having seven caudal setae, a claw-like process on the first antennular segment, one claw-like process on the maxillary syncoxa, the absence of an inner coxal seta on legs 1-4, different armatures on legs 1-4, and an elongate leg 5 exopod.

The calculation of stress intensity factors by the surface integral method

  • Jin, Chi-Sub;Jang, Heui-Suk;Choi, Hyun-Tae
    • Structural Engineering and Mechanics
    • /
    • v.3 no.6
    • /
    • pp.541-553
    • /
    • 1995
  • The determination of the stress intensity factors is investigated by using the surface integral defined around the crack tip of the structure. In this work, the integral method is derived naturally from the standard path integral J. But the use of the surface integral is also extended to the case where body forces act. Computer program for obtaining the stress intensity factors $K_I$ and $K_{II}$ is developed, which prepares input variables from the result of the conventional finite element analysis. This paper provides a parabolic smooth curve function. By the use of the function and conventional element meshes in which the aspect ratio (element length at the crack tip/crack length) is about 25 percent, relatively accurate $K_I$ and K_{II}$ values can be obtained for the outer integral radius ranging from 1/3 to 1 of the crack length and for inner one zero.

Current Sharing and AC Loss of a Multi-Layer HTS Power Transmission Cable with Variable Cable Length (다층 고온초전도 송전케이블의 길이에 따른 층별 전류분류 및 교류손실 계산)

  • Lee, Ji-Kwang;Cha, Guee-Soo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.1
    • /
    • pp.10-14
    • /
    • 2001
  • The superconducting transmission cable is one of interesting part in power application using high temperature superconducting wire. One important parameter in HTS cable design is transport current sharing because it is related with current transmission capacity and loss. In this paper, we calculate self inductances of each layer and mutual inductances between two layers from magnetic field energy, and current sharing of each layer for 4-layer cable using the electric circuit model which contain inductance and resistance (by joint and AC loss). Also, transport current losses which are calculated by monoblock model and Norris equation are compared. As a results, outer layer has always larger transport current than inner layer, and current capacity of each layer is largely influenced by resistance per unit cable length. As a conclusion, for high current uniformity and low AC loss, we have to decrease inductances themselves or those differences.

  • PDF