• 제목/요약/키워드: Inner Groove

검색결과 68건 처리시간 0.033초

수직관 흡수기의 물질전달에 미치는 계면활성제의 영향 (Influence of Surfactant on Mass Transfer of Vertical Absorber)

  • 권오경;윤정인;윤재호
    • 대한기계학회논문집B
    • /
    • 제27권5호
    • /
    • pp.604-611
    • /
    • 2003
  • This study was concerned with the enhancement of mass transfer by surfactant added to the aqueous solution of LiBr. Different vertical inner tubes were tested with and without an additive of normal octyl alcohol. The test tubes were a bare tube, groove tube, corrugate tube and inserted spring tubes. The additive concentration of normal octyl alcohol as a surfactant is about 0.08mass%. The Sherwood number was measured as a function of film Reynolds number 20~200. The experimental results were compared with those which use no surfactant. The enhancement of mass transfer by Marangoni convection effect which was generated by addition of the surfactant is proved for each testing tube Especially, it is clarified that the tube with the spring has the highest enhancement effect. A correlation of the experimental mass transfer data for the bare, groove, corrugate and insert spring tubes results expressed as the form of Sh=cㆍ Re$_{f}$ $^{n}$ .

Residual stress distribution analysis in a J-groove dissimilar metal welded component of a reactor vessel bottom head using simulation and experiment

  • Dong-Hyun Ahn;Jong Yeon Lee;Min-Jae Choi;Jong Min Kim;Sung-Woo Kim;Wanchuck Woo
    • Nuclear Engineering and Technology
    • /
    • 제56권2호
    • /
    • pp.506-519
    • /
    • 2024
  • To simulate the verification process using materials from a decommissioned reactor, a mock-up of the bottom-mounted instrument nozzle in the Kori 1 reactor, where the nozzle was attached to a plate by J-groove dissimilar metal welding, was fabricated. The mock-up distortion was quantified by measuring the plate surface displacement after welding. The residual stresses formed on the support plate surface and the inner surface of the nozzle were then analyzed using the hole-drilling method, contour method, and neutron diffraction. Welding simulations were performed using a 3D finite element method to validate the measured results. The measured and computed stress distributions on the support plate exhibited reasonable agreement. Conversely, the stresses on the inside of the nozzle were found to have an indisputable difference in the contour method and neutron diffraction measurements, which demonstrated strong tensile and compressive hoop stresses, respectively. The possible origins of such differences were investigated and we have provided some suggestions for a precise evaluation in the simulation. This study is expected to be useful in future research on decommissioned reactors.

가토의 두개골에서 Pore의 유무에 따른 티타늄 반구에서의 골형성 능 (The Bone Formation Potency on the Titanium Cap According to the Pore on the Rabbit Calvarium)

  • 박정표;오철중;정승곤;박홍주;오희균;유선열;국민석
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제35권1호
    • /
    • pp.18-24
    • /
    • 2013
  • Purpose: This study is performed to determine the effects of titanium cap with various sizes of pores on bone formation during guided bone regeneration (GBR). Methods: Calvaria from 10 adult male rabbits were chosen as the recipient sites. A trephine bur with a diameter of 10 mm was used to form one round groove on each side of sagittal suture of the cranium, and a round bur with a diameter of 1.5 mm was used to form 6 small holes on the inner circles of round grooves to induce bleeding. In the control group, bone graft was not conducted, and closed titanium cap was fixed in the round groove. Bone graft was not performed in groups 1 and 2, but fixed on titanium caps with 0.2 mm, and 0.5 mm sized pores, respectively. For groups 3, 4, and 5, a synthetic bone graft material (${\beta}$-tricalcium phosphate, Cerasorb$^{(R)}$, Germany) was transplanted, and titanium caps without pore, with 0.2 mm and 0.5 mm sized pore were fixed, respectively. The animals were sacrificed 4 weeks after, and clinical, radiographical, and histomorphometrical evaluation of bone regeneration was performed. Results: In all groups, there were no clinical signs of infection, inflammation or wound dehiscence. Radiographic evaluation revealed well-defined semi-circular radiopacity inside the titanium cap of groups 3, 4, and 5. Histologically, the inner surface of the hemisphere was evenly lined with newly formed bone tissue, as well as grafted bone material in the group 3. In groups 4 and 5, the insertion of connective tissue was observed along the inner surface. However, the overall surface area between the grafts with different holes yielded no statistical significance in the histomorphometrical evaluation. Conclusion: Although the total area of newly formed bone showed no significant difference, excellent bone formation tendency was observed histologically when closed caps were used with bone graft was accompanied.

실리콘 중공 가스켓의 대변형에 관한 연구 (A Study on the Large Deformation of Silicon Rubber Gasket with Hollow Circular Section)

  • 이태원
    • 한국정밀공학회지
    • /
    • 제20권11호
    • /
    • pp.150-157
    • /
    • 2003
  • In this paper, the large deformation of hollow silicon rubber gasket is treated. The frictional contact occurs between groove and the outer part of hollow gasket, and the frictional self-contact exists in the inner parts of hollow gasket. The silicon rubber has the nonlinear elastic behavior and its material property is approximately incompressible. Hence, the stress analysis requires an existence of a strain energy function, which is usually defined in terms of invariants or stretch ratio such as generalized Mooney-Rivlin and Ogden model. Considering large compressive deformation and friction, Mooney-Rivlin 3rd model and Coulomb's friction model are assumed. The numerical analysis is obtained by the commercial finite element program MARC. But, due to large deformation, the elements degenerate in the inner parts of hollow gasket. This means that the analysis of subsequent increments is carried out with a very poor mesh. In order to continue the analysis with a sufficient accuracy, it is necessary to use new finite element modeling by remesh. Experiments are also performed to show the validity of present method. As a conclusion, numerical results by this research have good agreements with experiments.

비등수형 원자로 발전소에의 레이저 피닝 적용기술 (Laser Peening Application for PWR Power Plants)

  • 김종도;유지 사노
    • Journal of Welding and Joining
    • /
    • 제34권5호
    • /
    • pp.13-18
    • /
    • 2016
  • Toshiba has developed a laser peening system for PWRs(pressurized water reactors) as well after the one for BWRs(boiling water reactors), and applied it for BMI(bottom-mounted instrumentation) nozzles, core deluge line nozzles and primary water inlet nozzles of Ikata Unit 1 and 2 of Shikoku Electric Power Company since 2004, which are Japanese operating PWR power plants. Laser pulses were delivered through twin optical fibers and irradiated on two portions in parallel to reduce operation time. For BMI nozzles, we developed a tiny irradiation head for small tubes and we peened the inner surface around J-groove welds after laser ultrasonic testing (LUT) as the remote inspection, and we peened the outer surface and the weld for Ikata Unit 2 supplementary. For core deluge line nozzles and primary water inlet nozzles, we peened the inner surface of the dissimilar metal welding, which is of nickel base alloy, joining a safe end and a low alloy metal nozzle. In this paper, the development and the actual application of the laser peening system for PWR power plants will be described.

한국산 꿩 난관깔때기의 조직학적 연구 (Histological Studies of the Infundibulum of the Oviduct of the Korean Native Pheasants(Phasianus colchicus korpowi))

  • 최성도;이영훈;김인식;양홍현
    • 한국가금학회지
    • /
    • 제26권3호
    • /
    • pp.171-177
    • /
    • 1999
  • This study was conducted for the histological observation of the infundibulum of the oviduct of the laying Korean native pheasants. The results are as follows : 1. The infundibular wall is composed of the epithelium, lamina propria, muscle layer(inner circular and outer longitudinal muscle), and serosa. The funnel lip is divided into the inner, and outer lip of the epithelium and muscle layer. 2. The epithelium of the funnel lip and most region of the cranial part of the funnel are composed of ciliated columnar cells. In the surface and lateral part of the folds, ciliated cells and non-ciliated secretory cells tend to alternate in the epithelium of the caudal funnel and the necks, but are also found in groups of the simple cuboidal epithelium at the bases of the grooves between the ridges and tubular glands found in the subepithelium. 3. The secretory material of the non-ciliated secretory cills contains PAS-positive and alcian blue-positive granules, and these materials show purple colour in the basic fuchsin-methylene blue stain. 4. The cells of the glandular groove and tubular gland of the neck portion of the oviduct mostly show weak PAS-positive, and alcian blue stain negative reaction. The tubular gland cells of the infndibulum contain pink of purple colour granules, and without reaction in the anterior neck portion of the infundibulum in basic fuchsin and methylene blue stain.

  • PDF

대형 크랭크축 리프팅 핀의 경량화를 위한 강도평가 연구 (A Study of Strength Evaluation of Crankshaft Lifting Pin for Reducing Weight)

  • 전병영;김병주;박종두
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.7-12
    • /
    • 2004
  • Large-sized pins are usually used to lift and handle large low speed diesel engine crankshaft. There has then been a need to reduce and optimize the weight of the traditionally used pins. Making an hole by cutting the inside of the pin out was investigated in view of static and fracture strength. To compensate the stress increase caused by the introduction of the inner hole, the groove in the circumferential direction pre-existing on the pin is to be removed. Finite element analysis was carried out for both the original model and weight reduced model. Stress intensity factors for semi-elliptical defects assumed on the pin for the original model and weight reduced model was calculated using the ASME method and compared with the fracture toughness test result of the pin material. The diameter of the cutting hole for the revised model was determined based on the analysis results.

  • PDF

A Study on the Failure Mode of the Rolling Bearing with Defective Balls

  • Hyun, J.S.;Park, T.J.
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 proceedings of the second asia international conference on tribology
    • /
    • pp.305-306
    • /
    • 2002
  • In this paper, the endurance life of the rolling bearings with defective balls and their failure (flaking) phenomena are presented. It was found that the lives of ball bearings with defective balls were shorter than that of calculated L10 life as well as that of normal bearings in spite of the using standard bearing components. Although the bearings were assembled with defective balls, whereas the other parts were qualified new ones, the main failures were occurred on the inner ring raceways. Moreover, the failures were on the center of the groove curvature and the severity of failure is similar to the order of initial defect depth of the balls. These shows that the defects on the bearings can affect the life of tribologically contacted mating parts.

  • PDF

이중 O링의 접촉거동 해석에 관한 수치적 연구 (A Numerical Study on the Contact Behavior Analysis of Double Layer O-rings)

  • 김청균;조승현
    • Tribology and Lubricants
    • /
    • 제19권1호
    • /
    • pp.9-14
    • /
    • 2003
  • The sealing performance of an elastomeric O-ring using the double layered material has been analyzed fer the contact stress behaviors that develop between the O-ring seal and the surfaces with which it comes into contact. The leakage of an O-ring will occur when the pressure differential across the seal Just exceeds the initial (or static) peak contact stress. The contact stress behaviors that develop in compressed O-rings, in common case of dovetail grooved geometry, are investigated using the finite element method. The FE analysis includes material hyperelasticity and axisymmetry. The computed FEM results show that the contact stress behaviors are related to the ratio of diameter between the inner ring and the outer ring, and the temperature of vacuum chamber.

복합소재 O-링 접합계면의 단열특성에 관한 컴퓨터 시뮬레이션 (Computer Simulation on Insulation Characteristics of Composite Material O-rings)

  • 김청균;김성원;조승현
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 제35회 춘계학술대회
    • /
    • pp.291-295
    • /
    • 2002
  • O-ring seal is usual component part in various mechanical apparatus for sealing that makes efficient performance of the equipments. The sealing performance of O-ring is affected in environments of the O-rings, like that applied pressure, working temperature, pre-compressed ratio and materials. In this paper, a pressurized, compressed elastomeric bi-polymer O-ring inserted into a rectangular groove is analyzed numerically using the MARC finite element program. The calculated FEM results showed that bi-polymer O-ring that is manufactured by NBR for an inner and FFKM for an outer ring shows a low temperature distribution among various bi-polymer O-ring models. But, the normal contact stress between the flange and upper part of the O-ring is small compared to other bi-polymer model.

  • PDF