• Title/Summary/Keyword: Inlet plane

Search Result 95, Processing Time 0.024 seconds

Cavitation in Pump Inducer with Axi-asymmetrical Inlet Plate Observed by Multi-cameras

  • Kim, Jun-Ho;Atono, Takashi;Ishizaka, Koichi;Watanabe, Satoshi;Furukawa, Akinori
    • International Journal of Fluid Machinery and Systems
    • /
    • v.3 no.2
    • /
    • pp.122-128
    • /
    • 2010
  • The attachment of inducer in front of main impeller is a powerful method to improve cavitation performance; however, cavitation surge oscillation with low frequency occurs with blade cavity growing to each throat section of blade passage simultaneously. Then, one conceptual method of installing suction axi-asymmetrical plate has been proposed so as to keep every throat passage away from being unstable at once, and the effect on suppression of the oscillation were investigated. In the present study, cavitation behaviors in the inducer is observed with distributing multi-cameras circumferentially, recording simultaneously and reconstructing multi-photos on one plane field as moving a linear cascade. Observed results are utilized for discussion with other measuring results as casing wall pressure distribution. Then the suppression mechanism of oscillation by installing axi-asymmetrical inlet plate will be clarified in more details.

Optimum Blind Control to Prevent Glare Considering Potential Time Error (잠재적 시간 오차에 따른 현휘의 발생 방지를 위한 최적 블라인드 제어)

  • Seong, Yoon-Bok
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.2
    • /
    • pp.74-86
    • /
    • 2012
  • For the improvement of environmental comfort in the buildings with the blind control, the objective of this study is to prevent the direct glare caused by the daylight inlet. During the process of solar profile prediction, time are significant factors that may cause error and glare during the blind control. This research proposes and evaluates the correction and control method to minimize prediction error. For the local areas with different longitude and local standard meridian, error occurred in the process of the time conversion from local standard time to apparent solar time. In order to correct error in time conversion, apparent solar time should be recalculated after adjusting the day of year and the equation of time. To solve the problems by the potential time errors, control method is suggested to divide the control sections using the calibrated fitting-curve and this method is verified through simulations. The proposed correction and control method, which considered potential time errors by loop lop leap years, could solve the problems about direct glare caused by daylight inlet on the work-plane according to the prediction errors of solar profile. And also these methods could maximize daylight inlet and solar heat gain, because the blocked area on windows could be minimized.

Heat/Mass Transfer Characteristics on the Squealer Tip Surface of a Turbine Rotor Blade (터빈 동익 스퀼러팁 표면에서의 열(물질)전달 특성)

  • Moon, Hyun-Suk;Lee, Sang-Woo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.1
    • /
    • pp.35-42
    • /
    • 2009
  • The flow and heat/mass transfer characteristics on the squealer tip surface of a high-turning turbine rotor blade have been investigated at a Reynolds number of $2.09{\times}10^5$, by employing the oil-film flow visualization and naphthalene sublimation technique. The squealer rim height-to-chord ratio and tip gap height-to-chord ratio are fixed as typical values of $h_{st}/c$ = 5.5% and h/c = 2.0%, respectively, for turbulence intensities of Tu = 0.3% and 15%. The results show that the near-wall flow phenomena within the cavity of the squealer tip are totally different from those over the plane tip. There are complicated backward flows from the suction side to the pressure side near the cavity floor, in contrast to the plane tip gap flows moving toward the suction side after flow separation/reattachment. The squealer tip provides a significant reduction in tip surface thermal load with less severe gradient compared to the plane tip. In this study, the tip surface is divided into six different regions, and transport phenomena at each region are discussed in detail. The mean thermal load averaged over the squealer cavity floor is augmented by 7.5 percents under the high inlet turbulence level.

PIV measurement of step cavity with driven flow (구동류를 갖는 계단 캐비티의 PIV계측)

  • 조대환;김진구;이영호
    • Journal of Ocean Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.113-119
    • /
    • 1998
  • An experimental study was carried out in a three-dimensional cubic cavity driven by 2-dimensional plane Poiseuille flow for three kinds of Reynolds number, $10^4$, 3 $\times$ $10^4$ and 5 $\times$ $10^4$ based on the cavity width and cavity inlet mean flow velcoity. Instant simultaneous velocity vectors at whole field were measured by 2-D PIV system. Laser based illumination and two-frame grey-level cross correlation algorithm are adopted. Severe unsteady flow fluctuation within the cavity are remarkable at above Re = 3 $\times$ $10^4$ Reynolds numbers and sheared mixing layer phenomena are also found at the region where inlet driving Poiseuille flow is collided with the clock-wise rotating main primary vortex at upper center area. Instant velocity profiles reveal that deformed forced vortex formation is observed throughout the separate two areas.

  • PDF

An Experimental Study on the Pressure and Temperature Distribution in a Plain Journal Bearing (저어널베어링의 압력 및 온도분포에 관한 실험적 연구)

  • 신영재;김경웅
    • Tribology and Lubricants
    • /
    • v.4 no.1
    • /
    • pp.69-73
    • /
    • 1988
  • The effects of journal speed and bearing load on pressure distribution and the temperature distribution of bearing surface are investigated experimentally. The journal bearing which has 219.94mm diameter, length-to-diameter ratio of L/D=0.8 and clearance ratio of 0.004 is used. Journal has a built-in pressure transducer for the measurement of pressure distribution in the mid plane of bearing. Bearing surface temperatures are measured at 60 points. The bearing load is varied from 300 N to 5900 N and journal speed from 300 rpm to 2500 rpm. As the load is increased under constant speed, the location of maximum pressure moves to the site of minimum film thickness, and maximum pressure and absolute value of minimum pressure are increased. The temperature distribution in vicinity of oil inlet shows that heated lubricant's carry-over exists around the oil inlet.

Surface Modification Using CVD-SiC (화학증착 탄화규소에 의한 표면 개질)

  • 김한수;최두진;김동주
    • Journal of the Korean Ceramic Society
    • /
    • v.33 no.7
    • /
    • pp.761-770
    • /
    • 1996
  • Silicon carbide (SiC) films were deposited by low pressure chemical vapor deposition (LPCVD) using MTS (CH3SICl3) in a hydrogen atmosphere onto graphite substrates. Depletion effects of reactants which usually occur in the hot wall horizaontal reactor were increased with deposition temperature and pressure. Below 50 torr of total pressure (111) plane was preferenctially grown irrespectrive of deposition temperature and deposition site. Over 50 torr of total pressure however (220) plane was preferentially deposited under 130$0^{\circ}C$ and at inlet site. The surface morphologies of SiC films were uniform at all deposition sites under low pressure but greatly changed with pressure. It shows that a facet structure which was formed above 125$0^{\circ}C$ played an important role in the changed of preferred orientation and surface roughness.

  • PDF

The performance of combined heat and power plant according to gas turbine air mass flow rate change (가스터빈 공기량 조절에 따른 열병합발전 성능 변화)

  • Kim, Jae-Hoon;Moon, Seung-Jae
    • Plant Journal
    • /
    • v.18 no.2
    • /
    • pp.32-40
    • /
    • 2022
  • In this study, we investigated the operation data of combined heat and power in accordance with the change of the inlet guide vane with partial load. The partial load 80% could close the inlet guide vane up to 24%, and the exhaust gas temperature could be increased by 52℃. The partial load 90% could close the inlet guide vane up to 12%, and the exhaust gas temperature could be increased by 23℃. At 80% of partial load with the thermal load tracking mode, the output could be increased up to 5.68 MW, the combined cycle efficiency increased by 0.73%, and the combined heat and power efficiency increased by 1.81%. At 90% of the partial load, the output could be increased up to 2.55 MW, the combined cycle efficiency increased by 0.32%, and the combined heat and power efficiency increased by 0.72%.

  • PDF

Measurement of Inward Turbulent Flows Subject to Plane Rate of Strain in a Rotating 90 Deg. Curved Duct of Variable Cross-Section (단순변형율 조건 하의 회전하는 가변단면 $90^{\circ}$ 곡덕트 내 내향 난류유동 측정)

  • Kim, Dong-Chul;Choi, Young-Don
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.765-770
    • /
    • 2000
  • Hot-wire measurements are reported on the developing turbulent flows subject to plane rate of strain in a rotating $90^{\circ}$ dog bend. The cross-section of the bend varies from $100mm{\times}50mm$ rectangular shape at the bend inlet gradually to the $50mm{\times}100mm$ shape at the bend outlet with remaining a constant area. Data signals from the rotating test section are transmitted through a slip ring to the personal computer which is located at the outside of the rotating disc. 3-dimensional velocity and 6 Reynolds stress components were calculated from the equations which correlate the fluctuating and mean voltage values measured with rotating a slant type hot-wire into 6 orientations. The effects of Coriolis and centrifugal forces on the mean motions and turbulence structures are investigated with respect to rotational speed.

  • PDF

Measurement of Outward Turbulent Flows Subject to Plane Rate of Strain in a Rotating 90 Deg. Curved Duct of Variable Cross-Section (단순변형률 조건 하의 회전하는 가변단면 $90^{\circ}$ 곡덕트내 외향 난류유동 측정)

  • Oh, Chang-Min;Choi, Young-Don
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.5
    • /
    • pp.623-631
    • /
    • 2000
  • Hot-wire measurements were carried out on the developing turbulent flows subject to plane rate of strain in a rotating curved duct. The cross-section of the curved duct varies from 100mm${\times}$50mm rectangular shape at the bend inlet gradually to the 50mm${\times}$100mm rectangular shape at the bend outlet. Experimental setup consists of the test section of $90^{\circ}$ curved duct, rotating disc of 1.95m diameter, Ag-Ni precision slip ring, automatic traversing mechanism, variable speed motor, centrifugal blower, orifice flowmeter and hot-wire anemometer. Data signals from the rotating curved duct are transmitted through the slip ring to the computer which is located at the outside of the rotating disc. 3-dimensional velocity and 6 Reynold stresses components were obtained from the fluctuating and mean voltage measured by the slant type hot-wire probe rotating into 6 orientations. We investigate the effects of Coriolis and centrifugal forces on the turbulence structure.

Flow Analysis due to the Configuration of Automotive Spoiler (자동차 스포일러의 형상에 따른 유동해석)

  • Han, Moonsik;Cho, Jaeung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.6
    • /
    • pp.677-683
    • /
    • 2016
  • In this study, the pressures due to air resistances on the models of 1, 2, 3 and 4 as the automotive bodies grafted on various spoilers are investigated through the flow analysis. Model 1 has the flat type and model 2 has the shape that a flat plane is projected. Model 3 is attached with the slanted plate and model 4 has the shape that two slanted plates are installed on both sides. At the flow streams on the models of 1, 2, 3 and 4, the flow velocities are shown to become highest above the roofs of automotive bodies. The maximum flow velocities are also shown at the beginning points at the roofs of car bodies on the side planes of automotive bodies. The maximum pressures of 102,500 to 102,553 Pa as air resistances are shown at the bumpers of the front car bodies. The flow velocities on the inlet and middle planes become nearly same at the models of 1, 2, 3 and 4. But these velocities on the inlet plane at model 2 projected with the spoiler of flat plate become lower than the models of 1, 3 and 4. The air streams throughout the models become uniform at all models. The flow stream is shown most uniformly at model 2 projected with the spoiler of flat plate. But the flow stream is shown most irregularly at model 3 projected with the spoiler of slanting plate. By using the result of this flow analysis, it is thought to reduce the power of car effectively in driving by changing the configuration of automotive spoiler.