• Title/Summary/Keyword: Inlet Cover Plate

Search Result 4, Processing Time 0.028 seconds

A Fracture Analysis on the Ceramic Dome with Different Geometry under Impact (충격을 받는 세라믹돔의 기하형상에 따른 파괴해석)

  • Kwon, Sun-Guk;Lee, Yung-Shin;Kim, Jae-Hoon;Lee, Jung-Hee;Yoon, Su-Jin
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.706-710
    • /
    • 2008
  • The experiment of dome port cover under shock impact is performed with shock tube. The dome port cover blocked intake air duct up from the solid propellant during air breathing vehicle speed reach Mach 2.0. When the air breathing vehicle reach Mach 2.0, the inlet cover is removed and the dome port cover is broken to pieces by detonator or pressure of inlet air. Thus the dome port cover not only must stand the pressure of combustion chamber but also easy to break from the RAM pressure. In this study, a fracture evaluation on the $Al_2O_3$ ceramic spherical dome and circular plate port under impact has been presented. Ceramic were supported by the rigid body and a couple of O-ring. The Mooney-Rivlin model have been used to describe behaviors of both O-ring. And spherical dome and circular plate fracture results of the LS-DYNA code using Johnson-Holmquist(JH-2) constitutive equation was compared.

  • PDF

Improvements of Inflow Controller Installed in Storm Overflow Diverging Tank for CSOs Control (우수토실에 설치된 월류수 제어를 위한 유입유량조절장치의 개선효과)

  • Lim, Bong-Su;Park, Youn-Hae;Kim, Tae-Eung
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.4
    • /
    • pp.428-435
    • /
    • 2015
  • This study was carried out to evaluate the performance of a inflow controller for the control of combined sewer overflows (CSOs). Because of the inflow controller could be adjusted manually by predicting the maximum amount of peak flow, the mechanical adjustment of this controller was higher than the existing fixed-type controller in field application. Standardizing the relationship between the flow and the clearance and angle of an inlet cover plate on the inflow conditions can selected to the optimum conditions for the on-site. It was concluded that BOD pollutant loading at the region in which inflow controller was installed had shown the removal efficiency rate of 42%.

The Flow Analysis and Evaluation of the Peristaltic Micropump (마이크로 정량펌프의 유동해석과 작동성능 평가)

  • 박대섭;최종필;김병희;장인배;김헌영
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.2
    • /
    • pp.195-202
    • /
    • 2004
  • This paper presents the fabrication and evaluation of mechanical behavior for a peristaltic micropump by flow simulation. The valve-less micropump using the diffuser/nozzle is consists of the lower plate, the middle plate, the upper plate and the tube that connects inlet and outlet of the pump. The lower plate includes the channel and the chamber, and the plain middle plate are made of glass and actuated by the piezoelectric translator. Channels and a chamber on the lower plate are fabricated on high processability silicon wafer by the DRIE(Deep Reactive Ion Etching) process. The upper plate does the roll of a pump cover and has inlet/outlet/electric holes. Three plates are laminated by the aligner and bonded by the anodic bonding process. Flow simulation is performed using error-reduced finite volume method (FVM). As results of the flow simulation and experiments, the single chamber pump has severe flow problems, such as a backflow and large fluctuation of a flow rate. It is proved that the double-chamber micropump proposed in this paper can reduce the drawback of the single-chamber one.

Performance Tests on Parallel Plate Type Solar Air Heater (공기식 평행판형 태양집열기 성능실험)

  • Cha Jong Hee;Song Hi Yul
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.6 no.4
    • /
    • pp.255-261
    • /
    • 1977
  • This study was concerned with the performance of solar air heater using parallel channels. Heat transmission model was developed and fabricated to increase the economic feasibility for solar heating system by using the cheap zinc plate. The prformance was discussed as a function of mass flow rate, and plate, inlet and outlet temperatures. Experimental results show that heat transmission model is sufficient for the analysis of thermal characteristics of air heater and collection efficiency is better than the domestic water heater, as the range 32-49 percent. Collection efficiency in the 2 layers of glass cover is better than that in 1 layer, so it is considered better to use the 2 layers of glass cover during the cold winter season in Korea.

  • PDF