• 제목/요약/키워드: Injection of resonant frequency

검색결과 14건 처리시간 0.023초

pH변화에 대한 Palmitic Acid LB막의 유기가스 반응특성 (The Response Properties of Organic Gas for the Palmitic Acid LB films by the Effect of pH)

  • 강기호;김정명;장정수;권영수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.317-319
    • /
    • 2000
  • We fabricated the QCM with Langmuir-Blodgett(LB) film deposited at the different subphase pH and investigated the resonant frequency response by the injection of organic gas response. In the $\pi$-A isotherms, the monolayer on the air/water interface had different limiting area per molecule and showed more condensed status as increasing the subphase pH. When palmitic acid LB film was deposited on the QCM, the resonant frequency shift was proportional to the deposited layer and had more resonant frequency shift in the case of the higher pH range as expected. In the resonant frequency for the injection of organic gas, it has been improved in the case of LB film fabricated at the lower subphase pH range and dependant upon the molecular weight of organic gas.

  • PDF

ZVS를 이용한 공진전류 주입형 고주파 공진 인버터의 특성해석 (Characteristic analysis of the resonant current injection type high frequency resonant inverter using ZVS)

  • 원재선;김해준;조규판;김동희;배영호;민병재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.1038-1040
    • /
    • 2001
  • A half-bridge type resonant current injection type high frequency resonant inverter using ZVS(Zero-Voltage-Switching) used as power source of induction heating at high frequency is presented in this paper. This proposed inverter can reduce distribution of the switching current because of using the current of serial resonant circuit to the input current of the parallel one. The analysis of the proposed circuit is generally described by using the normalized parameters, the principle of basic operating and the its characteristics are estimated by the parameters such as switching frequency and load resistance. According to the calculated characteristics value, this paper proves the validity of theoretical analysis through the Pspice.

  • PDF

Study on an Optimal Control Method for Energy Injection Resonant AC/AC High Frequency Converters

  • Su, Yu-Gang;Dai, Xin;Wang, Zhi-Hui;Tang, Chun-Sen;Sun, Yue
    • Journal of Power Electronics
    • /
    • 제13권2호
    • /
    • pp.197-205
    • /
    • 2013
  • In energy injection resonant AC-AC converters, due to the low frequency effect of the AC input envelope and the low energy injection losses requirement, the constant and steady control of the high frequency AC output envelope is still a problem that has not been solved very well. With the aid of system modeling, this paper analyzes the mechanism of the envelope pit on the resonant AC current. The computing methods for the critical damping point, the falling time and the bottom value of the envelope pit are presented as well. Furthermore, this paper concludes the stability precondition of the system AC output. Accordingly, an optimal control method for the AC output envelope is put forward based on the envelope prediction model. This control method can predict system responses dynamically under different series of control decisions. In addition, this control method can select best series of control decisions to make the AC output envelope stable and constant. Simulation and experimental results for a contactless power transfer system verify the control method.

Three-Phase AC-to-DC Resonant Converter Operating in High Power Factor Mode in High-Voltage Applications

  • Chaudhari, Madhuri A.;Suryawanshi, Hiralal M.;Kulwal, Abhishek;Mishra, Mahesh K.
    • Journal of Power Electronics
    • /
    • 제8권1호
    • /
    • pp.60-73
    • /
    • 2008
  • In this paper a three-phase ac-to-dc resonant converter with high input power factor and isolated output is proposed. To improve the input power factor of the converter, high frequency current is injected into the input of the three-phase diode bridge rectifier. It is injected through an impedance network consisting of a series of L-C branches from the output of the high frequency three-phase inverter. A narrow switching frequency variation is required to regulate the output voltage. A design example with different design curves is illustrated along with the component ratings. Experimental verification of the converter is performed on a prototype of 3 kW, 1000 V output, operating above 300 kHz. Experimental results confirm the concept of the proposed converter. Narrow switching frequency variation is required to regulate the output voltage.

Primary Current Generation for a Contactless Power Transfer System Using Free Oscillation and Energy Injection Control

  • Li, Hao Leo;Hu, Aiguo Patrick;Covic, Grant Anthony
    • Journal of Power Electronics
    • /
    • 제11권3호
    • /
    • pp.256-263
    • /
    • 2011
  • This paper utilizes free oscillation and energy injection principles to generate and control the high frequency current in the primary track of a contactless power transfer system. Here the primary power inverter maintains natural resonance while ensuring near constant current magnitude in the primary track as required for multiple independent loads. Such energy injection controllers exhibit low switching frequency and achieve ZCS (Zero Current Switching) by detecting the high frequency current, thus the switching stress, power losses and EMI of the inverter are low. An example full bridge topology is investigated for a contactless power transfer system with multiple pickups. Theoretical analysis, simulation and experimental results show that the proposed system has a fast and smooth start-up transient response. The output track current is fully controllable with a sufficiently good waveform for contactless power transfer applications.

고분자 감웅성 LB막을 이용한 One-channel 가스센서의 개발연구 (A Study on Development of One-channel Gas Sensor Using Polymeric Sensitive LB Films)

  • 강현욱;김정명;권영수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.261-263
    • /
    • 1996
  • The study on the development of one-channel gas sensor using the quartz crystal analyzer were attempted. The adsorption and desorption behavior of organic gases were investigated using the resonant frequency and resistance method of quartz crystal. The sensitive materials were deposited on the quartz crystal analyzer(QCA) by using Langmuir-Blodgett method. To investigate the response characteristics of organic vapours and response mechanism, resonant frequency-resonant resistance (F-R) diagram was used. In our experimental results, the response mechanism between sensitive LB film and organic vapours was obtained using F-R diagram. And the position of each organic vapour were different as to the kind and injection amount. Thus F-R diagram can be applied to one-channel gas sensor using the QCA and useful to analyze the response mechanism between organic vspours and sensitive LB films.

  • PDF

광주입 방법을 이용한 밀리미터파 신호 생성 (Optical Millimeter-wave Signal Generation using Injection Locking Scheme)

  • Kim, Jung-Tae
    • 한국정보통신학회논문지
    • /
    • 제7권5호
    • /
    • pp.1076-1081
    • /
    • 2003
  • 본 논문에서는 반도체레이저를 이용한 밀리미터파 대역의 신호를 생성하는 방법에 대해 제안하였다. 광대역에서의 밀리미터파 신호를 얻기 위해서는 윈하는 공진 주파수대역의 신호를 얻기 위해는 서브 하모닉의 좁은 신호 성분의 하모닉 신호인 다중의 신호를 서로 beating하여 원하는 주파수 대역의 신호를 얻을 수 있다. 따라서 본 논문에서는 반도체레이저를 사용한 광주입 방법을 통하여 실제적으로 원하는 주파수 대역의 신호를 얻기 위해 실험적으로 고찰하였으며, 신호 성분의 성능을 구하기 위해 phase noise 성분을 측정하였다.

Electronic Ballast Using a Symmetrical Half-bridge Inverter Operating at Unity-Power-factor and High Efficiency

  • Suryawanshi Hiralal M.;Borghate Vijay B.;Ramteke Manojkumar R.;Thakre Krishna L.
    • Journal of Power Electronics
    • /
    • 제6권4호
    • /
    • pp.330-339
    • /
    • 2006
  • This paper deals with novel electronic ballast based on single-stage power processing topology using a symmetrical half-bridge inverter and current injection circuit. The half-bridge inverter drives the output parallel resonant circuit and injects current through the power factor correction (PFC) circuit. Because of high frequency current injection and high frequency modulated voltage, the proposed circuit maintains the unity power factor (UPF) with low THD even under wide variation in ac input voltage. This circuit needs minimum and lower sized components to achieve the UPF and high efficiency. This leads to an increase in reliability of ballast at low cost. Furthermore, to reduce cost, the electronic ballast is designed for two series-connected fluorescent lamps (FL). The analysis and experimental results are presented for ($2{\times}36$ Watt) fluorescent lamps operating at 50 kHz switching frequency and input line voltage (230 V, 50 Hz).

감응성막의 유기가스 응답특성 분석 (The Analysis of Organic Gas Response Characteristic for Polymer Coating Materials)

  • 김정명;권영수;유승엽;최용성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.417-419
    • /
    • 1995
  • Polymer-coated piezoelectric crystals were applied to analyze response characteristic of organic gases. AT-cut quartz crystal with 9 MHz resonant frequency can measure mass of 1 nanogram. Flow type gas-sensing system was used in this experiment. Flow type gas-sensing system has very simple apparatus and shows very fast frequency response for injection of organic gas. We have made parameter using relaxation ratio of frequency response for organic gas. Consequently, we found that the parameter had no relation with quantity of gas injection and dipping.

  • PDF

A Capacitance Estimation of Film Capacitors in an LCL-Filter of Grid-Connected PWM Converters

  • Heo, Hong-Jun;Im, Won-Sang;Kim, Jang-Sik;Kim, Jang-Mok
    • Journal of Power Electronics
    • /
    • 제13권1호
    • /
    • pp.94-103
    • /
    • 2013
  • A capacitor deterioration of LCL-filter grid-connected PWM converters is progressed by the self-healing mechanism. It leads to the degradation of the filter performance and drop of power factor. Thus, it is required to diagnose fault-point of capacitors and determine the replacement time. Typically, the fault of capacitors is determined when the capacitance is reduced up to 80% from initial value. This paper proposes algorithm to the determine capacitor replacement time of an LCL filter. The algorithm takes the advantage of change of the response on the injected resonant frequency corresponding to 80% value from the initial capacitance. The results of the algorithm are demonstrated through simulations and experiments.