• 제목/요약/키워드: Injection current

검색결과 1,047건 처리시간 0.02초

인젝터 구동 전류 패턴 변화가 솔레노이드 타입 커먼레일 인젝터 분사율 특성에 미치는 영향에 대한 컴퓨터시뮬레이션 (A Computer Simulation of Injection Rate Characteristics of Solenoid Type Common Rail Injector According to Injector Driving Current Patterns)

  • 이충훈
    • 한국분무공학회지
    • /
    • 제24권3호
    • /
    • pp.114-121
    • /
    • 2019
  • The effect of injector driving current pattern on fuel injection rate of solenoid diesel common rail injector was studied by computer simulation. The time resolved fuel injection rate and injected quantity per stroke of a common rail injector driven with the five current patterns were computer simulated. The fuel injection rate and injected quantity per stroke according to the rail pressure and fuel injection period were also computer simulated. When the common rail injector was driven with the five driving current patterns of peak & hold, there was no difference in the fuel injection rate in the peak section regardless of all the current patterns of the five cases. On the other hand, the magnitude of the hold current value influenced the injection rate and injected quantity per stroke. That is, in the current pattern of three cases where the hold current value is equal to or more than a constant value of the peak current value, the fuel injection rates for the given common rail rail pressure and injection period are same one another. On the other hand, the current pattern of the two cases, in which the hold current value is smaller than a certain value, there is a large fluctuation in the fuel injection rate.

Variable-magnitude Voltage Signal Injection for Current Reconstruction in an IPMSM Sensorless Drive with a Single Sensor

  • Im, Jun-Hyuk;Kim, Sang-Il;Kim, Rae-Young
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1558-1565
    • /
    • 2018
  • Three-phase current is reconstructed from the dc-link current in an AC machine drive with a single current sensor. Switching pattern modification methods, in which the magnitude of the effective voltage vector is secured over its minimum, are investigated to accurately reconstruct the three-phase current. However, the existing methods that modify the switching pattern cause voltage and current distortions that degrade sensorless performance. This paper proposes a variable-magnitude voltage signal injection method based on a high frequency voltage signal injection. The proposed method generates a voltage reference vector that ensures the minimum magnitude of the effective voltage vector by varying the magnitude of the injection signal. This method can realize high quality current reconstruction without switching pattern modification. The proposed method is verified by experiments in a 600W Interior permanent magnet synchronous machine (IPMSM) drive system.

전류주입식 능동전력 필터를 위한 최적주입방법의 해석 (Analysis of Optimized Injection Method for Active Power Filter of Current Injection Type)

  • 박민호;최규하
    • 대한전기학회논문지
    • /
    • 제35권7호
    • /
    • pp.296-303
    • /
    • 1986
  • The active filter of current injection type is the device which eliminates the harmonics in ac line by injecting the harmonic compensating current into the ac side. And its harmonic reduction performance is entirely dependent on the control scheme of the current-fed inverter and the harmonic compensating current becomes the PWM wave by the inverter. This PWM compensating current can be determined by selecting the switching function properly which eliminates the harmonics up to any order with using no independent sources. The new injection current model is derived by the proposed method which is called the optimized injection method. The overall characteristics of the proposed method are investigated through digital computation and the feasibility is proved with experimental results obtained from the Z-80 microcomputer control of the active filter.

  • PDF

능동형 교류 전력 필터에 의한 고조파 보상전류의 새로운 주입방식 (A New Injection Method of Harmonic Compensation Current by Active AC Power Filter)

  • 박민호;최규하
    • 대한전기학회논문지
    • /
    • 제34권9호
    • /
    • pp.361-367
    • /
    • 1985
  • A new injection method is proposed for active power filters to eliminate AC harmonics in ac input current of nonlinear loads such as rectifiers. By injecting the PWM current determined by the proposed injection method, all the harmonics up to order nn can be eliminated to exactly zero. This PWM injection current can be generated by sampling total harmonic wave at the rate of M and the sampled values are converted into the proposed PWM wave with N pulse-width variables and adjustable current magnitude Im. These variables are deetermined by solving a set of N nonlinear harmonic equations and the harmonic-elimination characteristics of the new injection are investigated through digital computer sinmulation. Also by comparing between the simulated results and the ones synthesized by data stored in EPROM, the possibility of the suggested injection method can be shown.

  • PDF

Consideration of the Carrier Based Signal Injection Method in Three Shunt Sensing Inverters for Sensorless Motor Control

  • Jung, Sungho;Ha, Jung-Ik
    • Journal of Power Electronics
    • /
    • 제16권5호
    • /
    • pp.1791-1801
    • /
    • 2016
  • This paper considers a carrier based signal injection method for use in the three shunt sensing inverter (TSSI) for sensorless motor control. It also analyzes the loss according to the injection axis of the voltage signal. To remove both the phase current and rotor position sensors, a sensorless method and a phase current reconstruction method can be simultaneously considered. However, an interaction between the two methods can be incurred when both methods inject voltage signals simultaneously. In this paper, a signal injection based sensorless method with the 120° OFF Discontinuous PWM (DPWM) is implemented in a TSSI to avoid this interaction problem. Since one leg does not have a switching event for one sampling period in the 120° OFF DPWM, the switching loss is altered according to the injection axis. The switching loss in the d-axis injection case can be up to 32% larger than that in the q-axis injection case. Other losses according to the injection axis are also analyzed.

마이크로스트립 커플러 구조를 이용한 BCI 프로브 Emulator (BCI Probe Emulator Using a Microstrip Coupler)

  • 정원주;김소영
    • 한국전자파학회논문지
    • /
    • 제25권11호
    • /
    • pp.1164-1171
    • /
    • 2014
  • Bulk Current Injection(BCI) 테스트는 전류 주입 프로브를 사용하여 측정하고자 하는 Integrated Circuit(IC)에 전류를 주입하여 Electromagnetic Compatibility(EMC) 규격을 충족시키는지 시험하는 방법이다. 본 논문에서는 국제전기표준회의에서 제정한 IEC 62132-part 3에서 규정하는 BCI 테스트의 전류 주입 프로브를 대체하여, RF 잡음을 인가할 수 있는 마이크로스트립 커플러 구조를 제안하였다. 전통적으로 높은 전원 전압을 사용하는 자동차 IC 테스트에 사용되어 오던 BCI 전류 주입 프로브를 저 전압을 사용하는 저 전력 IC의 테스트에 사용할 수 있는 마이크로스트립 커플러 구조를 개발하여 그 유효성을 100 MHz에서부터 1,000 MHz까지의 주파수 영역에서 비교 및 검증하였다. 또한, 주파수에 따라 전류 주입 프로브를 통한 RF 잡음 인가와 마이크로스트립 커플러 구조를 통한 RF 잡음 인가 시 규정한 노이즈를 얻는데 필요한 전력을 dBm 단위로 측정, 비교하여 마이크로스트립 커플러 구조를 이용한 경우에 더 적은 전력으로 필요한 RF 잡음을 주입할 수 있음을 확인하였다.

금속-산화막-반도체(MOS) 소자에서의 전자주입에 따른 느린 준위의 전류 응답 특성 연구 (The Electron Injection-induced Slow Current Transients in Metal-Oxide-Semiconductor Capacitors)

  • 최성우;전현구;안병철;노관종;노용한
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 추계종합학술대회 논문집
    • /
    • pp.216-219
    • /
    • 1999
  • A simple two-terminal cyclic current-voltage(I-V) technique is used to measure the current-transients in MOS capacitors. Distinct charging/discharging currents were measured and analyzed as a function of (1) the hold time. (2) the gate polarity during the FNT electron injection, (3) the injection fluence and (4) the annealing time after the injection had stopped. Discharging and charging current-transients were strongly dependent upon the conditions for forming the inversion layer and the density of interface traps caused during the FNT electron injection, respectively. Several tentative mechanisms were suggested in the current work.

  • PDF

CIM(Current Injection Method)을 이용한 Charge-Pump 방식의 Plasma Backlight용 고압Inverter (Charge-Pump High Voltage Inverter for Plasma Backlight using Current Injection Method)

  • 장준호;강신호;이경인;이준영
    • 전력전자학회논문지
    • /
    • 제12권5호
    • /
    • pp.386-393
    • /
    • 2007
  • 본 논문에서는 CIM(Current Injection Method)을 이용한 charge-pump방식의 plasma backlight용 고압 inverter회로를 제안한다. 고압 inverter에서 에너지 회수회로의 채용은 새로운 시도로서 에너지회수 이외에도 noise에 의한 시스템의 불안정성과 방전안정화에 기여하고 있다. charge-pump방식으로 스위치류의 내압을 저감하므로 cost면에서 매우 유리한 조건을 확립하였으며 CIM(Current Injection Method)방식의 적용으로 high speed 에너지 회수를 가능하게 하였다. 그리고 제안회로의 동작을 모드별로 해석하였으며, 실제 32" 패널에 적용하여 실험함으로써 제안한 회로의 유용성을 입증하였다.

직렬접속형 다이오드 정류기 시스템의 전류주입에 의한 고조파 저감 (Drawing Sinusoidal Input Currents of Series-Connected Diode Rectifiers by A Current Injection Technique)

  • 오준용;최세완;김영석;원충연
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권11호
    • /
    • pp.640-645
    • /
    • 1999
  • This paper proposes a new series-connected diode rectifier which draws sinusoidal input currents. The proposed rectifier system is configured by adding an auxiliary circuit to the conventional 12-pulse series-connected diode rectifier and employing a current injection technique. A low kVA($0.02P_{\circ}$(PU) ) active current source injects a triangular current into the interphase reactor of the diode rectifier. The current injection results in near sinusoidal input current from the utility with less than 1% THD. The resulting system is suitable for high voltage and high power applications. Experimental and simulation results are provided from a 220V, 3kVA prototype rectifier system.

  • PDF

Primary Current Generation for a Contactless Power Transfer System Using Free Oscillation and Energy Injection Control

  • Li, Hao Leo;Hu, Aiguo Patrick;Covic, Grant Anthony
    • Journal of Power Electronics
    • /
    • 제11권3호
    • /
    • pp.256-263
    • /
    • 2011
  • This paper utilizes free oscillation and energy injection principles to generate and control the high frequency current in the primary track of a contactless power transfer system. Here the primary power inverter maintains natural resonance while ensuring near constant current magnitude in the primary track as required for multiple independent loads. Such energy injection controllers exhibit low switching frequency and achieve ZCS (Zero Current Switching) by detecting the high frequency current, thus the switching stress, power losses and EMI of the inverter are low. An example full bridge topology is investigated for a contactless power transfer system with multiple pickups. Theoretical analysis, simulation and experimental results show that the proposed system has a fast and smooth start-up transient response. The output track current is fully controllable with a sufficiently good waveform for contactless power transfer applications.