An Experimental Study on the Replication Ratio of Micro Patterns of 7 inch LGP using Injection/Compression and RHCM (사출/압축 및 RHCM 기술이 7인치 도광판 마이크로 패턴 전사성에 미치는 영향에 대한 실험적 연구)

  • Cho, S.W.;Kim, J.S.;Hwang, C.J.;Yoon, K.H.;Kang, J.J.
    • Transactions of Materials Processing
    • /
    • v.20 no.1
    • /
    • pp.11-16
    • /
    • 2011
  • Recently, according to the rapid development of display, many display applications, such as, cellular phone, navigation, monitor and LCD TV have been changed from CRT type to LCD type. BLU(Back Light Unit) is one of main parts in LCD unit and generally, it consists of a light source, a reflective sheet, a LGP(Light Guide Plate), a diffuser sheet, and two prism sheets. The most important component of BLU is a light guide plate, which diffuses the input light to the TFT-LCD module uniformly. The LGP is usually made by injection molding process, and it has numerous optical micro patterns on the surface. In the present study the micro-patterned stamper which has cylindrical shape was fabricated by using the UV-LiGA process. And the replication characteristics have been compared among three different kinds of injection molding process; general injection molding, injection/compression molding and RHCM(Rapid Heating and Cooling Molding). Average replication ratios of CIM and ICM were 19.1% and 64.6%, respectively. On the other hand, the average replication ratio of RHCM process showed the higher value of 98.4% among these. It show that maintaining the mold surface above $T_g$ could increase the replication ratio of micro patterns substantially.

Computational Thermo-Fluid Analysis for the Effects of Helium Injection Methods on Glass Fiber Cooling Process in an Optical Fiber Manufacturing System (광섬유 냉각장치의 헬륨 주입기 설계를 위한 전산열유동해석)

  • Park, Shin;Kim, Kyoungjin;Kim, Dongjoo;Park, Junyoung;Kwak, Ho Sang
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.2
    • /
    • pp.124-130
    • /
    • 2014
  • In a mass manufacturing system of optical fibers, the sufficient cooling of glass fibers freshly drawn from a draw furnace is essential, asinadequately cooled glass fibers can lead to poor resin coating on the fiber surface and possibly fiber breakage during the process. In order to improve fiber cooling at a high drawing speed, it is common to use a helium injection into a glass fiber cooling unit in spite of the high cost of the helium supply. The present numerical analysis carried out three-dimensional thermo-fluid computations of the cooling gas flow and heat transfer on moving glass fiber to determine the cooling performance of glass fiber cooling depending on the method of helium injection. The results showed that afront injection of helium is most effective compared to a uniform or rear injection for reducing air entrainment into the unit and thus cooling the glass fibers at a high fiber drawing speed. However, above a certain amount of injected helium, there was no more increase of the cooling effect regardless of the helium injection method.

Effect of Botulinum Toxin type A and Occlusal Splint on Masseter Muscle Evaluated with Computed Tomographic Measurement (전산화 단층촬영으로 평가한 교근에 대한 보툴리눔 A형 독소주사와 교합안정장치의 효과)

  • Jang, Hee-Young;Kang, Seung-Chul;Kim, Seong-Taek;Kim, Chong-Youl;Choi, Jong-Hoon
    • Journal of Oral Medicine and Pain
    • /
    • v.30 no.2
    • /
    • pp.247-255
    • /
    • 2005
  • The purpose of this study is to evaluate the effect of botulinum toxin type A on masseter muscle atrophy and the extent of masseter muscle affected from the injection site in relation to injection dose, with and without occlusal splint therapy through computed tomographic measurement. 32 volunteers were divided into four groups - group 25U (injection dose of 25 unit), group 25Us (injection dose of 25 unit with occlusal splint), group 35U (injection dose of 35 unit), group 35Us (injection dose of 35 unit with occlusal splint). Each group consisted of 8 people. 3 positions (position 1, 2, 3 - 10mm, 20mm and 40mm from the inferior border of the mandible, respectively) were selected for the evaluation of the masseter muscle change. The following results were obtained. 1. The thickness and the cross-sectional area of the masseter muscle had reduced in all groups except for the right side thickness at position 3 of group 25U and group 25Us, and the right side thickness as well as the left side cross-sectional area at position 3 of group 35Us. In group 35Us, the thickness and the cross-sectional area of the masseter muscle had reduced significantly in all positions (P < 0.05). 2. There was no significant difference in the masseter muscle change between the injection dose of 25unit and that of 35unit. 3. The groups with occlusal splint showed greater reduction of the masseter muscle thickness than the other groups (P < 0.05). From the above results, botulinum toxin type A injection together with occlusal splint therapy in the treatment of masseter muscle hypertrophy would be clinically effective.

A Study on the Development of an Electronic Control Unit for a Gasoline Engine using Microcomputer (마이크로컴퓨터를 이용한 가솔린 기관용 전자제어장치의 개발에 관한 연구)

  • Kim, T.H.;Cho, J.H.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.3 no.6
    • /
    • pp.224-237
    • /
    • 1995
  • An ECU(Electronic Control Unit) with 16 bit microcomputer has been developed. This system includes hardware and software for more precise control on fuel injection, ignition timing, and idle speed. This control system employs an air flow sensor of the hot wire type, a direct ignition system, an idle speed control system using a solenoid valve, and a crank angle sensor. Especially, the crank angle sensor provides two separate signals: One is the position signal(POS) which indicates 180 degree pulses per revolution, and the other is the reference signla(REF) that represents each cylinder individually. The conventional engine control system requires at least two engine revolutions in order to identify the cylinder number. However, the developed engine control system can recognize the cylinder number within a quarter of an engine revolution. Therfore, the developed engine control system has been able to control fuel injection and ignition timing more quickly and accurately, Furthermore, the number of misfire reduces during the cold start.

  • PDF

Effects of Central GABA and Glutamate on Blood Pressure and Single Unit Spikes in the RVLM of Rats

  • Park, Jae-Sik;Lee, Zee-Ihn;Jang, Jae-Hee;Ahn, Dong-Kuk
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.6 no.3
    • /
    • pp.149-154
    • /
    • 2002
  • The blood pressure (BP) is regulated by the nervous system and humoral factors, such as renin- angiotensin system, vasopressin and others. In the present study, we examined the central effects of glutamate and GABA on the cardiovascular regulation by injection of these substances into the lateral ventricle and also investigated the relationship between these central effects and the action of angiotensin II (Ang). Male Sprague Dawley rats, $350{\sim}400$ g, were anesthetized with urethane and instrumented with an arterial catheter for direct measurement of BP and heart rate (HR), and an guide cannula in the lateral ventricle for drug injection. A glass microelectode was inserted into the rostral ventrolateral medulla (RVLM) for recording single unit spikes. Barosensitive neurons were identified by changes of single unit spikes in RVLM following intravenous injection of nitroprusside and phenylephrine. The effects of GABA and glutamate injected into the lateral ventricle were studied in single neuronal activity of the RVLM in addition to changes in BP and heart rate, and compared the results before and after treatment with intravenous losartan, nonpeptide Ang II-type 1 receptor antagonist (1 mg/100 g BW). Intracerebroventricular administration of GABA decreased systolic blood pressure (SBP) and HR, but increased the firing rates in the RVLM. However, intracerebroventricular glutamate injection produced effects opposite to GABA. After pretreatment of intravenous losartan, the central effects of GABA on BP and firing rate in the RVLM were significantly attenuated and that of glutamate showed a tendency of attenuation. These results suggested that central GABA and glutamate regulated BP and firing rates in RVLM were inversely related to BP change. The central effects of GABA or glutamate on the autonomic nervous function were modulated by humoral factor, Ang II, by maintaining BP.

Korean Pharmacopuncture Meets Austrian High-Tech Acupuncture - A Short Review Article Including a Bibliometric Analysis of Pharmacopuncture over the Last 15 Years - Pharmacopuncture and Europe

  • Litscher, Daniela;Litscher, Gerhard;Kang, Dae-In
    • Journal of Pharmacopuncture
    • /
    • v.16 no.1
    • /
    • pp.7-11
    • /
    • 2013
  • Objective: Pharmacopuncture, a new therapy in traditional medicine, has attracted significant attention since its introduction to the Western world. This short review article employs a database analysis to examine the profile of publication activity related to pharmacopuncture. Methods: Three databases were searched: PubMed, Embase, and Cochrane. About 300 papers related to the topic "pharmacopuncture" were found in these three most-commonly-used databases. Results: Fourteen papers are described in detail and are discussed in the context of the research performed at the Medical University of Graz, especially by the Frank Bahr Research Group "Auriculomedicine and Pharmacopuncture." Conclusion: High-tech research methods concerning future pharmacopuncture studies are briefly discussed.

Evaluation of system design modifications for full system decontamination of Kori Unit 1

  • Kim, HakSoo;Kim, JeongJu;Kim, ChoRong
    • Nuclear Engineering and Technology
    • /
    • v.54 no.10
    • /
    • pp.3949-3956
    • /
    • 2022
  • Kori Unit 1 is planning a system decontamination project to reduce radiation exposure of decommissioning workers, prevent the spread of contamination and down-grade the level of classification of radioactive waste. The system decontamination range for Kori Unit 1 will be the entire primary system, including RCS, CVCS and RHRS. Some system design modifications are required for the system decontamination operation. In this paper, major system design modifications were evaluated based on the conditions that system restoration is needed after completion of system decontamination. The major system design modifications are CIDF connection location to system, system decontamination operating pressure control, RCP seal water injection and formation of letdown flow. It was evaluated that there was no negative effect on the system due to the system design modifications. However, as the RCP seal water is injected into the system in the oxidation process, the concentration of the oxidizing agent is diluted. Therefore, the oxidizing agent injection and system decontamination operation procedures should be developed to address the dilution effect of the oxidizing agent. The system design modifications dealt in this paper will be finally confirmed through on-site investigation in the future, and if necessary, the system design modifications will be re-evaluated.

Estimation of the Effective Hydraulic Conductivity in the Granite Area as an Equivalent Continuum Medium (등연속체매질로서의 화강암지역의 유효수리전도도 산출)

  • 김경수;김천수;배대석
    • The Journal of Engineering Geology
    • /
    • v.12 no.3
    • /
    • pp.319-332
    • /
    • 2002
  • This study is focused on the characterization of an effective hydraulic conductivity in each hydrogeologic unit assumed as an equivalent continuum medium in the granitic area. Four boreholes of 3" diameter were installed and a Multi-packer system was facilitated in the selected borehole. Various in-situ tests including the fracture logging, constant injection and fall-off tests, slug and pulse tests were carried out. A hydrogeologic unit was defined into the upper and lower zones based on the variation of fracture properties and hydraulic conductivities. The difference of the result obtained by the various hydraulic tests and the effective characterization techniques on rock mass permeability are also discussed. The effective hydraulic conductivity of the upper unit was measured by two times(5.27E-10 m/s~7.57E-10 m/s) that of the lower unit(2.45E-10 m/s~6.81E-10 m/s)through the constant injection and fall-off tests.