• Title/Summary/Keyword: Injection Unit

Search Result 362, Processing Time 0.03 seconds

Construction and actual material test of prism LGP not using function characteristic optical sheet for production of high brightness Back Light Unit

  • Han, J.M.;Yoon, D.K.;Park, D.S.;Oh, Y.S.;Bae, K.W.;Kim, Y.H.;Lim, Y.J.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1233-1235
    • /
    • 2004
  • We have designed High Performance Prism LGP in 17 inch TFT-LCD. In test result to embody high brightness BLU in case of LGP of base and upper surface with 17 inch, thickness 8mm adding prism construct, it is superior brightness improvement than previous that of printing form about some 20% and in this course to embody actual material it succeeded prism LGP production by 17 inch injection form process.

  • PDF

Thermal Viscoelastic Analysis of Plastic Part Considering Residual Stress (온도 및 잔류응력을 고려한 플라스틱 부품의 점탄성 해석)

  • Moon, H.I.;Kim, H.Y.;Choi, C.W.;Jeong, K.S.
    • Transactions of Materials Processing
    • /
    • v.17 no.7
    • /
    • pp.496-500
    • /
    • 2008
  • Plastics is commonly used in consumer electronics because of it is high strength per unit mass and good productivity. But plastic parts are usually distorted after injection molding due to the residual stress after filling, packing, cooling process, and etc. And plastic material is to be deteriorated according to various temperature conditions and operating time, which can be characterized by stress relaxation and creep. The viscoelastic behavior of plastic materials in time domain can be expressed by the Prony series of the commercial code, ABAQUS. In the paper, the process to predict the post deformation under cyclic thermal loadings was suggested. The process was applied to the real panel, and the deformation predicted by the analysis was compared with that of real test, which showed the possibility of applying the suggested process to predict the post deformation of plastic product under thermal loadings.

A Study on the Multipurpose Three Phase Synthetic Testing Circuit for A.C. E.H.V. Circuit Breakers (초고압전력용차단기에 대한 다목적합성실험회의에 관한 연구)

  • 변성봉;정재길;윤병도;류형기
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.12
    • /
    • pp.1296-1305
    • /
    • 1990
  • Common enclosure type SF6 circuit breakers have been developed in many countries for their compact design and economical merits, but their performance testing method is one of the difficult problems because of the limitation of testing capacity. This paper studies a three phase synthetic testing circuit which consists of 4-unit circuits based on the current injection method. This new synthetic testing circuit can be used in both ways of three phase testing up to 242kV rating and single phase testing up to 800kV rating.

  • PDF

The optimum simulation and real test of double prismatic Light-guide plate for a high brightness LCD backlight unit

  • Yoon, D.K.;Park, D.S.;Oh, Y.S.;Bae, K.W.;Kim, K.H.;Lim, Y.J.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1503-1506
    • /
    • 2005
  • This dissertation represents method concerning high performance prism LGP design in 17 inch TFT-LCD. By means of developing LGP with total size of 8mm that has prism on both upper side and bottom side, it is superior to previous printing way in gaining high brightness. It can realize actual material simulation on prism LGP production using 17inch injection process and about 20% luminance enhancement is achieved based on such method.

  • PDF

Diagnosis and Treatment of Early Ankle Osteoarthritis (초기 발목관절염의 진단과 치료)

  • Sang, Gyo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.21 no.4
    • /
    • pp.117-121
    • /
    • 2017
  • The incidence of arthritis in the ankle is relatively low compared to other joints. On the other hand, it receives a lot of pressure per unit area, is vulnerable to damage, and arthritis can arise after trauma. Early ankle arthritis can be considered a case of osteophyte subchondral sclerosis without narrowing of the joint space. Conservative treatment, such as weight control, insole use, drug use, and injection therapy for early ankle arthritis, is effective and can be considered before surgical treatment. Nevertheless, if pain is persistent, surgical treatment to remove bony spurs is effective. Ensuring that there is no other cause of pain when deciding whether to perform an operation is very important.

A Study on the Flow Characteristics of Mixer by Impeller Types (임펠러 형상에 따른 교반기의 유동특성에 관한 연구)

  • 양창조;최민선;이영호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.7
    • /
    • pp.899-905
    • /
    • 2003
  • Mixers are used in several industrial applications where it is necessary to strongly mix reactants in a short period of time (eg. reaction injection molding, ceramics manufacturing, crystallization). However, despite their widespread use, mixing flow characteristics in these systems have not been rigorously investigated. Influence of blade shapes on the mixing time and the power consumption per unit volume in two kinds of impeller including the mixing effects are studied by PIV experiment. A series of the experiments were carried out to achieve a better mixing effect in simple baffle arrangement and tall vessel with modified impellers(two kinds of blades : pitched blade turbine and rushton turbine). Results show that periodic vortex from the mixing layer is predominant and related unsteady flow characteristics prevail over the entire region.

Composition and Evaluation of the Thermal Desorption-Gas Chromatographic System for the Measurement of Volatile Organic Compounds in Air (공기 중 휘발성 유기화합물의 측정을 위한 열탈착-분석시스템의 구성 및 평가)

  • 이수형;송희남;김희갑
    • Environmental Analysis Health and Toxicology
    • /
    • v.17 no.1
    • /
    • pp.63-71
    • /
    • 2002
  • The thermal desorption-gas chromatographic (TD-GC) system has been constructed for the measurement of volatile organic compounds. The thermal desortion unit is composed of four major parts: 1) the control part; 2) the thermal desorption part; 3) the focusing part; and 4) the injection part. The peltier element was introduced to the focusing part for the temperature of the focusing tube to reach-35$^{\circ}C$. The system was tested for the linearity of the calibration curves and reproducibility of instrumental analyses using some disinfection by-products (DBPs) and BTXs (benzene, toluene and p-xylene). The coefficients of determination (r$^2$) for all the calibration curves made were higher than 0.998, and the coefficients of variation (CV) for triplicate measurements were all within 10%. The system also has been tested for field applicability. The analysis of field samples showed that there was no breakthrough problem in the sampling system and that the system could be applied to field measurements.

Optimization of Heavy-Duty Diesel Engine Operating Parameters Using Micro-Genetic Algorithms (유전알고리즘을 이용한 대형 디젤 엔진 운전 조건 최적화)

  • Kim, Man-Shik;Liechty, Mike P.;Reitz, Rolf D.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.2
    • /
    • pp.101-107
    • /
    • 2005
  • In this paper, optimized operating parameters were found using multi-dimensional engine simulation software (KIVA-3V) and micro-genetic algorithm for heavy duty diesel engine. The engine operating condition considered was at 1,737 rev/min and 57 % load. Engine simulation model was validated using an engine equipped with a high pressure electronic unit injector (HEUI) system. Three important parameters were used for the optimization - boost pressure, EGR rate and start of injection timing. Numerical optimization identified HCCI-like combustion characteristics showing significant improvements for the soot and $NO_X$ emissions. The optimized soot and $NO_X$ emissions were reduced to 0.005 g/kW-hr and 1.33 g/kW-hr, respectively. Moreover, the optimum results met EPA 2007 mandates at the operating point considered.

THE DEVELOPMENT OF FAN COIL UNIT MOTOR WITH PLASTIC FRAME (합성수지 프레임을 이용한 휀코일 유니트 모터 개발)

  • Lee, Sun-Hwi
    • Proceedings of the KIEE Conference
    • /
    • 1987.11a
    • /
    • pp.61-66
    • /
    • 1987
  • The metals has been used to the electric motor frame and brackets. The purpose of this project is to substitute engineering plastic doter frame for metal because of the demand for small size and environmental reliability. As a result of considering of mechanical strength, heat and injection characteristic of engineering plastics. PBT GF 30 has been selected as the material of electric motor frame including brackets. Design of the frame has been carried out on enough consideration of mechanical strength, heat-resisting and endurance. For the prevention of lower efficiency, the length of airgap between stator and rotor is reduced and for the reduction of vibration, slot combination is changed and the length of stator is increased.

  • PDF

A Modeling and Simulation Implementation on the Power Line Disturbances by Loss of Contact for the High-Speed Railway Vehicle (고속전철 주행시 이선에 따른 전원외란 현상 모델링 및 시뮬레이션 구현)

  • Kim, Jae-Moon;Kim, Yang-Soo;Chang, Chin-Young;Gimm, Yoon-Myoung
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1137-1142
    • /
    • 2008
  • In this paper, an effect on power conversion unit in high-speed railway vehicle by loss of contact between a catenary system and pantograph suppling electrical power to high-speed railway vehicle are investigated. One of the most important needs accompanied by increasing the speed of high-speed railway vehicle is reduced that arc phenomenon by loss of contact brings out EMI. in case of high-speed railway vehicle using electrical power, as comparison with diesel rolling stock, PLD(Power Line Disturbance) such as harmonic, transient voltage and current, EMI, dummy signal injection etc usually occur. To analysis the effect on loss of contact, it is necessary electrical modeling system between the contact line and the pantograph according to the loss of contact. Therefore analytical model of a contact line and a pantograph is constructed to simulate the behaviour of loss of contact. The reliability of the modeling system is verified by simulation implementation on kinds of loss of contact.

  • PDF