• Title/Summary/Keyword: Injection Material

Search Result 1,137, Processing Time 0.032 seconds

Usefulness Comparative Experimental Study of the CT and MR Imaging in the Dog Clonorchiasis (잡견 간흡충증의 전산화단층촬영과 자기공명영상의 유용성에 관한 실험적 연구)

  • Goo, Eun-Hoe;Kweon, Dae-Cheol;Kim, Dong-Sung;Choi, Chun-Kyu
    • Journal of radiological science and technology
    • /
    • v.26 no.3
    • /
    • pp.33-39
    • /
    • 2003
  • Purpose : Be aware of clinical possibilities on image quality by comparison of contrast-enhanced dynamic CT and MR imaging applied of MIP technique after the experimentally induced clonorchasis infection in dogs. Materials and Method : Twenty mongrel dogs prepared in zoo-laboratory were followed up with serial CT scans and MR imaging for 13 weeks after the experimental infection in liver. Two-phase helical CT was acquired in the supine position with the following scanning parameters. After the injection of contrast material, the arterial phase was initiated using a bolus-racking method. The portal phase scan was started 15 seconds after the arterial phase scan. CT protocol was determined after single level dynamic scans. MR imaging used the CP body coil and images get a 2D image using HASTE, FLASH, TSE pulse sequence. Bile duct MR imaging were obtained in three plans. Then each image was post processed by using target MIP algorithm. Two experimentation above, as a method of evaluation, one pathologist, three radiologist and five radiological technologist were analyzed visually for evaluation of following findings, enhancement of the bile duct wall, dilatation of bile duct tip, liver parenchyma, background suppression. Results : Five dogs was died of a disease after the infection, the rest one else shows the chronic dilatation of the intrahepatic bile duct with CT and MR imaging. Contrast administration of CT shows the contrast-enhanced of the bile duct walls with live parenchyma. MR imaging calculated of CNR and CR from pulse sequence for comparative evaluation and shows the pattern of the intrahepatic bile duct, dilatation of bile duct tip using MIP technique. CNR of the clonorchiasis, HASTE was $16{\pm}0.83$, TSE $7.06{\pm}3.0$, FLASH $1.19{\pm}0.2$ and CR, HASTE was 73.3%, TSE 62.3%, FLASH 6.4%. Conclusion : CT and MR imaging is very usefulness in diagnosis of dog clonorchiasis.

  • PDF

A Study on the Knowledge and Attitude about Tuberculosis on Elementary School student in Seoul (서울 시내 일부 국민학교 6학년 학생들의 결핵에 대한 지식 및 실태에 관한 연구)

  • Kim, Eun-Hee
    • Research in Community and Public Health Nursing
    • /
    • v.5 no.2
    • /
    • pp.181-202
    • /
    • 1994
  • This study was conducted in order to grasp the condition of the student's knowledge and attitude about tuberculosis. And to offer the basic materials for the prevent tuberculosis in elementary school. The objects were comprised 395 of volunteered 6th grade students who study in two elementary schools. The material of this study was the questionaire(chronbach $\alpha=.9016$) suited to the purposed of this research which has been made through studying references. All the questionaire were collected immediately without explanation. The data was collected from 13rd to 25th of May on 1994. Analysis of the data was done utilizing SPSS for percentage, mean, ANOVA and pearson-Correlation Coefficient. The Result are as follows; 1. General features of the objects of study. Sex distribution was similar. Salary of 1000-1500 thousand won were highest (40.2%), nuclear family was highest (87.1%), fathers of graduated high school were the highest(44.0%), mothers of graduated high school were the highest(56.8%). And there was nobody about tuberculosis patient in one's close relatives were highest(95.4%). 2. The conditions of attitude about tuberculosis. Having experience of tuberculin test were highest(59.0%). Less than 9mm indulation among the tuberculin tested group were 85.1%, more than indulation were 14.9%. Have a B. C. G. injection among the less than 9mm indulation were 83.2%. Leave alone among the more than 10mm indulation were 56.0%. Think it too much trouble to do not tuberculine test were 63.0%. Do not take a chest X-ray in the past were 60.3%. And take a chest X-ray in the past were 39.7%. Health educated group was 74.3%. If tuberculosis sign was developed, notified to parent was 73.8%. 3. The condition of knowledge about tuberculosis. When 5 points was given to 'very affiming' and 1 point was given to 'very deny', the total average was 3.54. And symptom of tuberculosis secion was 3.67, vaccination of tuberculosis section was 3.66, tuberculine test section was 3.56, epidemiology of tuberculosis section was 3.54, infection of tuberculosis section was 3.38. And every section showed affirmative correlation(P<.001). 4. Correlation between the general features and attitude variables. High incomed group may have more attitude on tuberculin test than low incomed group($x^2=16.$ 190, P<.01). High educated group may have more attitude on tuberculin test than low educated group(Father : $x^2=28.530$, P<.001, Mother: $x^2=26.060$, P<.001). High educated group may have more attitude on health education than low educated group(Father: $x^2=20.$ 767, P<.000, Mother: $x^2=10.639$, P<.05). Nuclear family may have more attitude on notify to parent than others($x^2=51.45$, P<.000). Tuberculosis patient in one's close associates have more attitude on notify to parent than others($x^2=51.$ 45, P<.000). 5. Difference between the general features and knowledge of tuberculosis. High incomed group were highest score in knowledge (F=3.99, P<.01). High educated group were highest score in knowledge(Father : F=8.81, P<.000, Mother: F=9.09, P<.000). 6. Difference between the attitude and knowledge of tuberculosis. Tuberculin tested group were highest score in knowledge(t=9.88, P<.000). Taken chest X-ray group were highest score in knowledge (t=2.07, P<.05). Received health education group were highest score in knowledge(t=6.83, P<.000). Notified symptoms to teachers and parent group were highest score in knowledge(F=3.89, P<.01).

  • PDF

A Study on Accounting for Nursing Cost by Korean Diagnosis Related Groups (K - DRGs) (종합병원(綜合病院)의 간호행위양상(看護行爲樣相)에 따른 간호원가(看護原價) 산정(算定)에 관(關)한 연구(硏究))

  • Oh, Hyo-Sook
    • Journal of Korean Public Health Nursing
    • /
    • v.3 no.2
    • /
    • pp.5-46
    • /
    • 1989
  • The current medical payment Insurance Rates in Korea stipulate charges for medical treatment by the doctor, pharmaceutist, medical technician and maternity nurse. But unfortunately didn't specify those charges for nursing done by the professional nurse. Only basic nursing fee is accounted insufficiently in current medical insurance fee schedule. therefore, Being face with covering entire people by medical insurance by 1991, It seems that the problems pertaining to operating the hospital and medical insurance system would be incessantly expanded in that no mention is made of medical charges rendered by major medical producer service in the current system, For that reason, this study made an attempt to clarify the importance the professional nursing puts of the current medical payment. The purpose of this study was to accounting nursing fee which diveded into the current medical fee schedule. (Method) 1. Data collection; Importance and difficulties in nursing activities was conducted in 'S' National University Hospital. Total nursing activities were selected 72 items which included direct care and indirect care. This study was conducted to evaluating the degree of importance and difficulties according to nursing activities through questionnaire to 204 RN. and so relative difficulties (acuity) were computered because the nursing cost level of each nursing service was differently established by the equivalent coefficient according to degree of relative difficulty and time required. 2. Calculation of cost according to nursing activities; After 47 nursing activities were selected in General surgery nursing units, calculation of nursing cost was as follows Cost of Nursing activity = (relative difficulty X Average hourly wage and benefits of nurse) + material cost of nursing -t- Average nursing administration cost So, Calculated cost by nursing activities was compared to current non-insured and insurance rate. 3. Calculation of nursing cost by K - DRG ; Total of 578 patients who were hospitalized in General Surgery units from January to March 1988 ware classified by K - DRG After estimation of total nursing cost based on the K-DRG, verified the appropriateness of basic nursing fee in medical insurance rate (Results) 1. Analysis of degree of importance and difficulties were 4.16 and 3.67 based on 5 point scale. This score were judged that it is worthy specifying the nursing fee 2. The nursing cost of 47 nursing service items in general surgery patients showed that the average cost of nursing activity was \1374.5 and The lowest cost was \217 of 'oral administration nursing' item, The highest cost was \11,025 of 'saline enematill clear' item 3. The result of comparison between the calculated cost by nursing activities against the current non-insured and insurance rate showed that 13 items(27.7%) involved to payment of insurance rate, 9 items(19.1%) involved to non-insured rate, remainder 25 items (53.2%) were not charged anywhere of total 47 nursing activities 4. When calculated cost by nursing activities was 100. current insurance rate was 62.3, non-insured rate was 176.6. Therefore this showed that most of non-insured rate were higher than calculated nursing cost. The insurance rate, however, were lower than it. Reim-bursement was imputed to non-insured patients. So the current rate system became estrainged from cost system. When Remainder 25 items of nursing activities compared' to \1390 of daily basic nursing fee per patient belonged to payment as a insurance fee schedule, basic nursing fee schedule was 1-2% of calculated cost of nursing activities. Therefore it showed that nursing fee was not counted adequately in it. 5. Nursing cost by K-DRG estimated in chart review based on counting number of nursing activities and length of stay The result showed that average amount of total nursing cost was \183828.1 Comparison of nursing cost calculated by K- DRG and basic nursing fee schedule showed that only 12.3% of nursing cost was charged (Conclusion) From the above research result, It is fact that nursing prime cost should be estimated more accurately and included adequately in current medical payment system. The payment system of nursing activities should be introduced not only nursing activities of drug administration and injection fee belonged to insurance fee schedule but also most nursing activities belonged not to mekical fee schedule. Even if introducing payment system of nursing activities, It should be estimated scientific method of Accounting nursing cost So nurses could offer nursing care of good quality, thereby they could make a great contribution not merely to the convalescence of the patient but to the promotion of the people's health.

  • PDF

A Study on the Stability and Sludge Energy Efficiency Evaluation of Torrefied Wood Flour Natural Material Based Coagulant (반탄화목분 천연재료 혼합응집제의 안정성 및 슬러지 에너지화 가능성 평가에 관한 연구)

  • PARK, Hae Keum;KANG, Seog Goo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.48 no.3
    • /
    • pp.271-282
    • /
    • 2020
  • Sewage treatment plants are social infrastructure of cities. The sewage distribution rate in Korea is reaching 94% based on the sewage statistics based in the year of 2017. In Korean sewage treatment plants, use of PAC (Poly Aluminum Chloride) accounts for 58%. It contains a large amount of impurities (heavy metal) according to the quality standards, however, there have been insufficient efforts to reinforce the standards or technically improve the quality, which resulted in secondary pollution problems from injecting excessive coagulant. Also, the increase in the use of chemicals is leading to the increases in the annual amount of sewage sludge generated in 2017 and the need to reuse sludge. As such, this study aims to verify the possibility of reusing sludge by evaluating the stability of heavy metals based on the injection of coagulant mixture during water treatment which uses the torrefield wood powder and natural materials, and evaluating the sedimentation and heating value of sewage sludge. As a result of analyzing heavy metals (Cr, Fe, Zn, Cu, Cd, As, Pb, and Ni) from the coagulant mixture and PAC (10%), Cr, Cd, Pb, Ni, and Hg were not detected. As for Zn, while its concentration notified in the quality standards for drinking water is 3 mg/L, only a small amount of 0.007 mg/L was detected in the coagulant mixture. Maximum amounts of over double amounts of Fe, Cu, and As were found with PAC (10%) compared to the coagulant mixture. Also, an analysis of sludge sedimentation found that the coagulant mixture showed a better performance of up to double the speed of the conventional coagulant, PAC (10%). The dry-basis lower heating value of sewage sludge produced by injecting the coagulant mixture was 3,378 kcal/kg, while that of sewage sludge generated due to PAC (10%) was 3,171 kcal/kg; although both coagulants met the requirements to be used as auxiliary fuel at thermal power plants, the coagulant mixture developed in this study could secure heating values 200 kal/kg higher than the counterpart. Therefore, utilization of the coagulant mixture for water treatment rather than PAC (10%) is expected to be more environmentally stable and effective, as it helps generating sludge with better stability against heavy metals, having a faster sludge sedimentation, and higher heating value.

Comparison of Effectiveness about Image Quality and Scan Time According to Reconstruction Method in Bone SPECT (영상 재구성 방법에 따른 Bone SPECT 영상의 질과 검사시간에 대한 실효성 비교)

  • Kim, Woo-Hyun;Jung, Woo-Young;Lee, Ju-Young;Ryu, Jae-Kwang
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.9-14
    • /
    • 2009
  • Purpose: Nowadays in the nuclear medicine, many studies and efforts are being made to reduce the scan time, as well as the waiting time to be needed to execute exams after injection of radionuclide medicines. Several methods are being used in clinic, such as developing new radionuclide compounds that enable to be absorbed into target organs more quickly and reducing acquisition scan time by increase the number of Gamma Camera detectors to examine. Each medical equipment manufacturer has improved the imaging process techniques to reduce scan time. In this paper, we tried to analyze the difference of image quality between FBP, 3D OSEM reconstruction methods that commercialized and being clinically applied, and Astonish reconstruction method (A kind of Iterative fast reconstruction method of Philips), also difference of image quality on scan time. Material and Methods: We investigated in 32 patients that examined the Bone SPECT from June to July 2008 at department of nuclear medicine, ASAN Medical Center in Seoul. 40sec/frame and 20sec/frame images were acquired that using Philips‘ PRECEDENCE 16 Gamma Camera and then reconstructed those images by using the Astonish (Philips’ Reconstruction Method), 3D OSEM and FBP methods. The blinded test was performed to the clinical interpreting physicians with all images analyzed by each reconstruction method for qualitative analysis. And we analyzed target to non target ratio by draws lesions as the center of disease for quantitative analysis. At this time, each image was analyzed with same location and size of ROI. Results: In a qualitative analysis, there was no significant difference by acquisition time changes in image quality. In a quantitative analysis, the images reconstructed Astonish method showed good quality due to better sharpness and distinguish sharply between lesions and peripheral lesions. After measuring each mean value and standard deviation value of target to non target ratio with 40 sec/frame and 20sec/frame images, those values are Astonish (40 sec-$13.91{\pm}5.62$ : 20 sec-$13.88{\pm}5.92$), 3D OSEM (40 sec-$10.60{\pm}3.55$ : 20 sec-$10.55{\pm}3.64$), FBP (40 sec-$8.30{\pm}4.44$ : 20 sec-$8.19{\pm}4.20$). We analyzed target to non target ratio from 20 sec and 40 sec images. And we analyzed the result, In Astonish (t=0.16, p=0.872), 3D OSEM (t=0.51, p=0.610), FBP (t=0.73, p=0.469) methods, there was no significant difference statistically by acquisition time change in image quality. But FBP indicates no statistical differences while some images indicate difference between 40 sec/frame and 20 sec/frame images by various factors. Conclusions: In the circumstance, try to find a solution to reduce nuclear medicine scan time, the development of nuclear medicine equipment hardware has decreased while software has marched forward at a relentless. Due to development of computer hardware, the image reconstruction time was reduced and the expanded capacity to restore enables iterative methods that couldn't be performed before due to technical limits. As imaging process technique developed, it reduced scan time and we could observe that image quality keep similar level. While keeping exam quality and reducing scan time can induce the reduction of patient's pain and sensory waiting time, also accessibility of nuclear medicine exam will be improved and it provide better service to patients and clinical physician who order exams. Consequently, those things make the image of department of nuclear medicine be improved. Concurrent Imaging - A new function that setting up each image acquisition parameter and enables to acquire images simultaneously with various parameters to once examine.

  • PDF

$^{99m}Tc-MAG_3$ Elimination Index on Normal Functioning Transplanted Kidney ($^{99m}Tc-MAG_3$ 제거지수를 이용한 이식신장의 기능평가)

  • Jeon, Woo-Jin;Kim, Ju-Heon;Park, Mi-Ok;Lee, Hee-Jung;Hyun, Jung-Ae;Zeon, Seok-Kil
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.79-83
    • /
    • 1995
  • Purpose : We analysed $^{99m}Tc-MAG_3$ renal scans to evaluate renal function of transplanted kidney and to detect various renal transplant complications, measuring the ratio of renal radioactivity at three minutes to that at 20 minutes(elimination index). Material and Methods : The fifty seven renal transplantation recipients were studied. There were 50 normal functioning transplanted kidneys as group I and 7 abnormal function-ing transplanted kidney, including 5 cases of acute renal rejection, 2 cases of acute tubular necrosis as group IIl. The protocol consisted of: (1) $^{99m}Tc-MAG_3$ 740MBq injection intravenously : (2) sequential imaging for 2min(60two-second images) followed by 30min(30 sixty-second images) : (3) drawing of region of interest(ROI) on renal imaging; (4) time-activity corves were generated from renal ROI after background subtraction, and time of maximum activity($T_{max}$) and half time of maximal peak radioactivity($T_{1/2}$) were produced in the renogram curve. (5) EI through Bischof-Delaloye method as determined on the renogram curve. Results : Normal group( I ) shows mean EI of 2.21(95.0% Confidence limit of 2.01-2.87), $T_{max}$ of 154 sec, $T_{1/2}$ of 1,139 sec. Abnormal group(II) shows mean EI of 0.74, $T_{max}$ of 1,466 sec, $T_{1/2}$ of 19,224 sec. The EI, $T_{max}$, $T_{1/2}$, BUN and serum creatinine values are significantly different between normal group(I) and abnormal group(II) (p<0.0001). Conclusion : By measuring EI with $^{99m}Tc-MAG_3$, renal function of transplanted kidney could be easily evaluated and various complications could be detected early.

  • PDF

Mycelial Culture of Lentinus edodes Alleviates Rat Liver Toxicity Induced by Carbon Tetrachloride and Ethanol (표고버섯균사체의 사염화탄소 및 알콜로 처리된 흰쥐 간기능 보호 효과)

  • Ha, Yeong-L.;Kim, Young-S.;Ahn, Chae-R.;Kweon, Jung-M.;Park, Cherl-W.;Ha, Young-K.;Kim, Jeong-O.
    • Journal of Life Science
    • /
    • v.20 no.1
    • /
    • pp.133-141
    • /
    • 2010
  • The protective effect of a mixed powder from solid-cultured and liquid-cultured Lentinus edodes mycelia (2:1, w/w) (designate LED) on the carbon tetrachloride ($CCl_4$)- and ethanol-induced hepatotoxicity of male Sprague-Dawley (SD) rat was investigated. In the $CCl_4$-induced rat hepatotoxicity experiment, rats of 4 groups (6 rats/group) were administere with Normal (0.2 ml distilled water), Control (0.2 ml distilled water), LED (LED 200 mg/kg BW + 0.2 ml distilled water), and Silymarin (200 mg/kg BW + 0.2 ml distilled water), p.o., daily for 2 weeks. Afterwards, all groups except for the Normal group were subjected to abdominal injection with $CCl_4$ ($CCl_4$ : corn oil, 1:1 v/v; 0.5 ml/kg BW). For the ethanol- induced rat hepatotoxicity experiment, rats were divided into 5 groups (5 rats/group): Normal; Pair-fed control (PFC); Control (ethanol); LED (ethanol + LED 200 mg/kg BW); and Silymarin (ethanol + silymarin 200 mg/kg BW). Rats of the Normal and PFC groups were fed a basal liquid diet, and rats of the Control, LED, and Silymarin groups were fed a liquid ethanol diet containing LED or Silymarin. Eight weeks later, blood and liver samples were collected to analyze biomarkers. In $CCl_4$-induced SD rats, LED elevated hepatic superoxide dismutase (SOD), catalase, and glutathione peroxidase (GSH peroxidase) activities and thiobarbituric reactive substances (TBARS) were reduced, resulting in the reduction of glutamate-oxalate transaminase (GOT), glutamate-pyruvate transaminase (GPT) and lactic dehydrogenase (LDH) activities in plasma. Similar results of these enzymes and biochemical markers in both liver tissues and plasma were seen in ethanol-induced hepatotoxicity of SD rats. In addition, elevated alcohol dehydrogenase (ADH) activity and reduced expression of cytochrome p450 mixed monooxygenase enzyme (CYP2E1) were seen in liver tissues from ethanol-treated rats by LED treatment. These effects of LED were similar to those of Silymarin. In in vitro experiments, LED showed antioxidant activity in a 2,2-diphenyl-1-picrylhydrazyl (DPPH) system and mouse liver mitochondria system induced by NADPH/$Fe^{2+}$ and cumine hydroperoxide (CuOOH). These results indicate that LED protected SD rat hepatotoxicity, induced by $CCl_4$ and ethanol, through its antioxidative activity and might be useful as a material for protection from hepatoxicity in humans.

Clinical Utility of Turbo Contrase-Enhanced MR Angiography for the Major Branches of the Aortic Arch (대동맥궁 주요 분지들의 고속 조영증강 자기공명혈관조영술의 임상적 유용성)

  • Su Ok Seong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.2 no.1
    • /
    • pp.96-103
    • /
    • 1998
  • Purpose : To assess the clinical utility of turbo contrast-enhanced magnetic resonance angiography(CE MRA) in the evaluation of the aortic arch and its major branches and to compare the image quality of CE MRA among different coils used. Materials and Methods : Turbo three-phase dynamic CE MRA encompassing aortic arch and its major branches was prospectively performed after manual bolus IV injection of contrast material in 29 patients with suspected cerebrovascular diseases at 1.0T MR unit. the raw data were obtained with 3-D FISH sequence (TR 5.4ms, TE 2.3ms, flip angle 30, slab thickness 80nm, effective slice thickness 4.0mm, matrix size $100{\times}256$, FOV 280mm). Total data acquisition time was 4. to 60 seconds. We subjectively evaluated the imge quality with three-rating scheme : "good" for unequivocal normal finding, "fair" for relatively satisfactory quality to diagnose 'normal' despite intravascular low signal, and "poor" for equivocal diagnosis or non-visualization of the origin or segment of the vessels due to low signal or artifacts which needs catheter angiography. At the level of the carotid bifurcation, it was compared with conventional 2D-TOF MRA image. Overall image quality was also compared visually and quantitatively by measuring signal-to-noise ratios (SNRs) of the ascending aorta, the innominate artery and both common carotid arteries among the three different coils used(CP body array(n=12), CP neck array(n=9), and head-and-neck(n=8). Results : Demonstration of the aortic arch and its major branches was rated as "good" in 55% (16/29) and "fair" in 34%(10/29). At the level of the carotid bifurcation, image quality of turbo CE MRA was same as or better than conventional 2D-TOF MRA in 65% (17/26). Overall image quality and SNR were significantlygreater with CP body array coil than with CP neck array or head-and-neck coil. Conclusions : Turbo CE MRA can be used as a screening exam in the evaluation of the major branches of the aortic arch from their origin to the skull base. Overall imagequality appears to be better with CP body array coil than with CP neck array coil or head-and-neck coil.

  • PDF

Optimal Level for the Protection of Carbon Tetrachloride-induced Sprague-Dawley Rat Liver Damage by Mycelial Cultures of Lentinus edodes (Sprague-Dawley 쥐의 사염화탄소 유도 간 손상에 대한 표고버섯균사체의 효과)

  • Jang, Wook-J.;Kim, Young-S.;Ha, Yeong-L.;Park, Cherl-W.;Ha, Young-K.;Kim, Jeong-O.
    • Journal of Life Science
    • /
    • v.20 no.5
    • /
    • pp.782-788
    • /
    • 2010
  • The protective effects of a powder mixed with solid-cultured and liquid-cultured Lentinus edodes mycelia (2 : 1, w/w) (designate LED) with different doses of carbon tetrachloride ($CCl_4$) on induced hepatotoxicity in male Sprague-Dawley (SD) rats was investigated. The rats were divided into seven groups (6 rats/group) and the following substances were administered orally to each group: Vehicle (0.2 ml distilled water), Control (0.2 ml distilled water), LED (LED 100, 200, 300 and 400 mg/kg BW in 0.2 ml distilled water), and Silymarin (200 mg/Kg BW in 0.2 ml distilled water). After two weeks of daily administration, all groups except for the Vehiclegroup were subjected to abdominal injection with $CCl_4$ ($CCl_4$ : corn oil, 1 : 1 v/v; 0.5 ml/kg BW). One day later, blood and liver samples were collected to analyze biomarkers. All LED treatments elevated hepatic superoxide dismutase (SOD), catalase and glutathione peroxidase (GSH peroxidase) activities, and reduced thiobarbituric reactive substances (TBARS), tumor necrosis factor-$\alpha$ (TNF-$\alpha$), interleukin-$1{\beta}$ (IL-$1{\beta}$) and interleukin-6 (IL-6), resulting in the reduction of glutamate-oxalate transaminase (GOT), glutamate-pyruvate transaminase (GPT) and lactic acid dehydrogenase (LDH) activities in plasma. These results indicate that LED effectively protected SD rat hepatotoxicity induced by $CCl_4$ through its antioxidative activity and reduction of some cytokines. The highest efficacy was found in LED 200 mg/kg BW, showing potential as a useful material for protection from hepatotoxicity in humans.

$^{99m}Tc$-Tetrofosmin Scintimammography in Suspected Breast Cancer Patients: Comparison with $^{99m}Tc$-MIBI (유방암이 의심되는 환자에서 $^{99m}Tc$-Tetrofosmin을 이용한 유방스캔: $^{99m}Tc$-MIBI와 비교)

  • Kim, Seong-Jang;Kim, In-Ju;Kim, Yong-Ki;Bae, Young-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.2
    • /
    • pp.119-128
    • /
    • 2000
  • Purpose: The aim of this study was to investigate the diagnostic role of $^{99m}Tc$-Tetrofosmin in detection of breast cancer and compared with that of $^{99m}Tc$-MIBI. Material and Methods: Forty-eight patients with a clinically palpable mass or abnormal mammographic or ultrasonographic findings had $^{99m}Tc-MIBI\;and\;^{99m}Tc$-Tetrofosmin scintimammographies after intravenous injection of 925 MBq of radiopharmaceuticals. The scintimammographs were correlated with histopathologic findings. Results: Thirty-three patients were diagnosed with breast cancer and 15 patients with benign breast diseases. The numbers of true positive, true negative, false positive, and false negative cases of $^{99m}Tc$-MIBI scintimammography were 29, 10, 5, and 4 respectively. The sensitivity, specificity, positive predictive value, and negative predictive value of $^{99m}Tc$-MIBI scintimammographies were 87.8%, 66.7%, 85.3%, and 71.4% respectively. The numbers of true positive, true negative, false positive, and false negative cases of $^{99m}Tc$-Tetrofosmin were 31,10, 5, and 2 respectively. The sensitivity, specificity, positive predictive value, negative predictive value of $^{99m}Tc$-Tetrofosmin were 93.9%, 66.7%, 86.1%, and 73.3% respectively. One patient was false negative in both $^{99m}Tc-MIBI\;and\;^{99m}Tc$-Tetrofosmin acintimammographies and its size was 0.5 cm. Conclusion: $^{99m}Tc-Tetrofosmin\;and\;^{99m}Tc-MIBI$ were non-invasive and useful in detection of breast cancer and $^{99m}Tc$-Tetrofosmin was comparable to the $^{99m}Tc$-MIBI in detection of primary breast cancer.

  • PDF