• Title/Summary/Keyword: Injection Amount

Search Result 884, Processing Time 0.024 seconds

A Study on the Combustion Characteristics of Ultra High Pressure Fuel Injection System in a Diesel Engine(I) (초고압 연료분사장치 디젤기관의 연소특성에 관한 연구(I))

  • Choi, D.S.;Rhee, Kyung-Tai
    • Journal of ILASS-Korea
    • /
    • v.4 no.1
    • /
    • pp.34-44
    • /
    • 1999
  • The purposes of this study were to evaluate engine performance and to analyze smoke emission characteristics for varied injection pressures and engine operating conditions of an electronically-controlled ultra high pressure fuel injection system(UHPFIS). It was discovered that the engine performance with the present UHPFIS was far better than what was initially expected. And the UHPFIS permitted engine operation at air/fuel ratios richer than 20 : 1 without increasing smoke emissions. It was discovered that the indicated mean effective pressure was increased, while the specific fuel consumption and the amount of soot were decreased, as the fuel rail pressures were improved atomization of the fuel spray. As the intake air temperature was increased from $38\sim205^{\circ}C$ in 38 degree increments, the indicated mean effective pressure was dropped while the specific fuel consumption was increased.

  • PDF

Prediction of Core Shift using Injection Molding CAE program (사출성형 CAE 프로그램을 이용한 코어 휨의 예측)

  • Moon, Jeong-Yeon;Kwak, Min-Hyuk;Park, Tae-Won;Jeong, Yeong-Deug
    • Design & Manufacturing
    • /
    • v.8 no.2
    • /
    • pp.7-11
    • /
    • 2014
  • The Core-Shift is often generated on injection mold which have thin and long core. And Core-Shift brings out problems for thickness variation and product ejecting process. In this study, analysis of Core-Shift was performed according to change of materials of core(steel P-20, Be-Cu) and various polymers(PP, PC) by using MoldFolw MPI 6.1 which is commercial injection molding analysis program. As the results of analysis, the magnitude of Core-Shift was increased as being use polymer had lower fluidity and lower rigidity core. In the future, we will study the relationship between amount of Core-Shift and ejecting force.

  • PDF

In-Cylinder Fuel Behavior According to Fuel Injection Timing and Port Characteristics in an SI Engine : Part III-With High Swirl (가솔린 엔진에서 연료분사시기와 포트특성에 따른 실린더 내 연료거동 : Part III - 고와류의 경우)

  • 엄인용;조용석
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.3
    • /
    • pp.18-26
    • /
    • 2001
  • This paper is the third of 3 companion papers which investigate axial stratification process. In-cylinder fuel behavior has been investigated in the port injected SI engine by visualizing for the purpose of understanding stratification. Planar laser light sheet from an Nd:YAG laser has been illuminated through the transparent quartz cylinder of the single cylinder optical engine and the Mie scattered light has been captured through the quartz window in the piston head with an ICCD camera. Fuel has been replaced with an air-ethanol mixture to utilize atomized fuel spray for the visualization purposes. This results have been compared with steady flow concentration measurement. In high swirl port, the most fuel remains at combustion chamber and upper cylinder region without being affected by injection timing. The macro-distributed state is not changed but the difference of the amount of fuel around the spark plug varies according to injection timing, which determines LML.

  • PDF

A Study on Warpage of Injection molded Fiber Reinforced Plastic Composities (사출성형된 섬유강화 플라스틱 복합재의 뒤틀림에 관한 연구(이론과 실험 결과의 비교))

  • 조선형
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.03b
    • /
    • pp.136-142
    • /
    • 1999
  • The injection molded part shrinks in the process of solidification by the amount of the coefficient of linear thermal expansion multiplied by the temperature difference between the coefficient of linear thermal expansion multiplied by the temperature difference between the room temperature and the temperature at which the solid structure is formed in the mold And it is called warpage for this type of deformation that shrinkage are not uniform throughout the injection molded part. To predict warpage phenomena in the articles the results obtained theoretically from the change of mold temperature fiber content of composites have been compared with exsperimental results.

  • PDF

A Study of Fluoride Injection in Water Supply (상수도수 불소투입에 관한 연구)

  • Kim, Sung-Soon;Lee, Yang-Kyoo;Kim, Gab-Jin;Seo, Seong-Won
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.10 no.4
    • /
    • pp.73-84
    • /
    • 1996
  • Fluoride was first introduced into the drinking water of residents of Grand Rapids, Michigan in 1945 for the prevention of dental caries. Ever since, growing numbers of communities favor fluoridation. Now, over 7000 communities in the United States are adding F(0.7~1.2ppm) to their drinking water. The most effective to prevent tooth decay is putting lower concentrated fluoride(F, 0.7~1.2ppm) into drinking water. However, exact fluoride injection amount have not been decided, because the research of the fluoride injection effect was insufficient. Therefore, after separating fluoridation and non-fluoridation into public water supplies, we investigated concentration of fluoride, alkalinity, Al, Ca, Mg, evaporation residuals in APT, domestic, commercial area. Then, we decided allowable concentration of fluoride, injection point of fluoride in water supply system, cost effectiveness.

  • PDF

A Study on Improvement of Birefringence Characteristics of Injection-Molded Plastic Parts by Rapid Mold Heating (급속 금형가열에 의한 사출성형품의 복굴절특성 개선에 관한 연구)

  • Park, Keun;Kim, Byung H.
    • Transactions of Materials Processing
    • /
    • v.16 no.4 s.94
    • /
    • pp.229-233
    • /
    • 2007
  • The present work focuses on the prediction of birefringence in injection-molded part and its improvement by rapid mold heating. To calculate birefringence, flow-induced residual stress is computed through a fully three-dimensional injection molding analysis. Then the stress-optical law is applied from which the order of birefringence can be evaluated and visualized. The birefringence patterns are predicted for a rectangular plate with a variation of mold temperature, which shows that the amount of molecular orientation and birefringence level decreases with an increase of mold temperature. The effect of mold temperature on the order of birefringence is also studied for a thin-walled rectangular strip, and the relevant results are compared with experimental measurements. Both predicted and experimental patterns of birefringence are in agreements on the observation that the birefringence level diminishes significantly when the mold temperature is raised over the glass transition temperature.

Durability Properties of Liquid Phase LPG Injection System with Various Qualities of LPG Fuels (LPG연료품질에 따른 LPG액상분사방식의 내구특성연구)

  • 김창업;오승묵;강건용
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.5
    • /
    • pp.73-78
    • /
    • 2004
  • The liquid phase LPG injection (LPLi) system (the third generation technology) has been considered as one of the next generation fuel supply systems for LPG vehicles, since it has a very strong potential to accomplish the higher power, higher efficiency, and lower emission characteristics than the mixer type(the second generation technology) fuel supply system. To investigate the durability property of core part of injector in liquid phase LPG injection system, leakage test, SEM test of injectors and analysis of unvaporized fuel components with various LPG fuel qualities were tested. The experimental results showed that no serious problem in durability test using favorable LPG fuel quality, while high leakage amount due to the large scratches in the needle and nozzle of the injector were found using LPG fuel with highly containing olefin components, especially butadiene species.

Probability Adjustment Scheme for the Dynamic Filtering in Wireless Sensor Networks Using Fuzzy Logic (무선 센서 네트워크에서 동적 여과를 위한 퍼지 기반 확률 조절 기법)

  • Han, Man-Ho;Lee, Hae-Young;Cho, Tae-Ho
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2008.08a
    • /
    • pp.159-162
    • /
    • 2008
  • Generally, sensor nodes can be easily compromised and seized by an adversary because sensor nodes are hostile environments after dissemination. An adversary may be various security attacks into the networks using compromised node. False data injection attack using compromised node, it may not only cause false alarms, but also the depletion of the severe amount of energy waste. Dynamic en-route scheme for Filtering False Data Injection (DEF) can detect and drop such forged report during the forwarding process. In this scheme, each forwarding nodes verify reports using a regular probability. In this paper, we propose verification probability adjustment scheme of forwarding nodes though a fuzzy rule-base system for the Dynamic en-route filtering scheme for Filtering False Data Injection in sensor networks. Verification probability determination of forwarding nodes use false traffic rate and distance form source to base station.

  • PDF

Changes of Aldosterone Secretion Rate Following Furosemide Administration in Normotensive Subjects with High Sodium Intake (Furosemide 투여후 Aldosterone 분비율의 변동)

  • Sung, Ho-Kyung;Ryu, Yong-Wun;Koh, Joo-Hwan
    • The Korean Journal of Nuclear Medicine
    • /
    • v.10 no.1
    • /
    • pp.55-60
    • /
    • 1976
  • Marked augmentation of urinary aldosterone excretion following furosemide administration was observed in previous experiment. In this study, author measured the changes of aldosterone secretion after furosemide administration in normotensive young volunteers with high sodium intake. After intravenous injection of $1.2-^3H-aldosterone$, urine samples were collected in course of time until 24 hours after the injection. Furosemide administration was done at 30 minutes prior to aldosterone injection. Specific activities of $^3H-aldosterone$ during and after diuresis were measured and aldosterone secretion rates were calculated dividing the doses by specific activities. Results were as followed 1. Furosemide resulted in a marked increase in urinary aldosterone excretion. 2. Furosemide lead to an increase in both sodium and potassium excretion. 3. Aldosterone secretion rate was also increased during furosemide diuresis, but the rate was smaller than that of urinary excretion. 4. Continuous modest increase in aldosterone secretion rate was shown after diuresis and total excess amount of aldosterone secretion for 24 hrs was equivalent to the amount of aldosterone excretion produced by diruesis. 5. Abrupt marked loss of circulating aldosterone produced by diuresis was supplemented by long lasting increase in secretion for over twenty four hours.

  • PDF

The Usability Evaluation of Application that is Developed the Dynamic Kidney Phantom System in Nuclear Medicine

  • Kim, Jae-Hyun;Lee, Juyoung;Park, Hoon-Hee
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.16 no.2
    • /
    • pp.15-24
    • /
    • 2014
  • Currently commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desires to evaluate the usefulness of nuclear medicine imaging. The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using 99mTc-pertechnate. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn five times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Depending on the speed of injection, radioisotope was a lot of integrated and emissions up when adjusting the pressure of the pump as 30 stroke, it was the least integrated and emissions up when adjusting as 40 stroke. The integration of the left & right kidney was not reached in the amount of the highest when adjusting as 10 stroke. In the changes according to the amount of the radioactive isotope, 0.6 mCi(22.2 MBq), 0.8 mCi (29.6 MBq)was showed up similar tendency but, in the result of the injection 0.8 mCi, it was showed up counts close to double of 0.6 mCi. In the result of the differently injection speed of the left & right kidney, as a result of different conditions that injection speed was 20 stroke through left kidney phantom, the injection speed was 30 stroke through right kidney phantom, it was enough difference in the resulting image can be easily distinguished with the naked eye. Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

  • PDF