• 제목/요약/키워드: Initiation crack

검색결과 821건 처리시간 0.026초

Experimental and numerical analyses on determination of indirect (splitting) tensile strength of cemented paste backfill materials under different loading apparatus

  • Komurlu, Eren;Kesimal, Ayhan;Demir, Serhat
    • Geomechanics and Engineering
    • /
    • 제10권6호
    • /
    • pp.775-791
    • /
    • 2016
  • The indirect tensile strengths (ITSs) of different cemented paste backfill mixes with different curing times were determined by considering crack initiation and fracture toughness concepts under different loading conditions of steel loading arcs with various contact angles, flat platens and the standard Brazilian test jaw. Because contact area of the ITS test discs developes rapidly and varies in accordance with the deformability, ITSs of curing materials were not found convenient to determine under the loading apparatus with indefinite contact angle. ITS values increasing with an increase in contact angle can be measured to be excessively high because of the high contact angles resulted from the deformable characteristics of the soft paste backfill materials. As a result of the change of deformation characteristics with the change of curing time, discs have different contact conditions causing an important disadvantage to reflect the strength change due to the curing reactions. In addition to the experimental study, finite element analyses were performed on several types of disc models under various loading conditions. As a result, a comparison between all loading conditions was made to determine the best ITSs of the cemented paste backfill materials. Both experimental and numerical analyses concluded that loading arcs with definite contact angles gives better results than those obtained with the other loading apparatus without a definite contact angle. Loading arcs with the contact angle of $15^{\circ}$ was found the most convenient loading apparatus for the typical cemented paste backfill materials, although it should be used carefully considering the failure cracks for a valid test.

해저터널의 특성을 고려한 계측 개념 및 관리 방안 (Management and concept of the monitoring system considering the characteristics of subsea tunnels)

  • 박의섭;신희순;천대성;정용복
    • 한국터널지하공간학회 논문집
    • /
    • 제15권5호
    • /
    • pp.523-536
    • /
    • 2013
  • 해저터널은 육상의 지하구조물과 달리 시공 및 운영 중의 안전성을 확보하기 위해서는 기존의 육상터널에 적용된 응력과 변위계측과 더불어 해저터널의 특성을 고려한 계측이 필수적으로 요구된다. 따라서 해저터널의 안정성을 평가하고자 NATM에 적용되는 개념을 정리하고, 계측계획 수립을 위한 관측 시스템(observation system), 터널의 안전관리를 위한 임계변형률 이론과 국부적으로 발생하는 암석과 지보재의 파괴나 균열의 생성을 파악할 수 있는 미소파괴음 계측을 소개하고, 이러한 방법들을 사용한 해저터널 계측 및 관리방안을 제시하였다.

In-situ Raman Spectroscopic Study of Nickel-base Alloys in Nuclear Power Plants and Its Implications to SCC

  • Kim, Ji Hyun;Bahn, Chi Bum;Hwang, Il Soon
    • Corrosion Science and Technology
    • /
    • 제3권5호
    • /
    • pp.198-208
    • /
    • 2004
  • Although there has been no general agreement on the mechanism of primary water stress corrosion cracking (PWSCC) as one of major degradation modes of Ni-base alloys in pressurized water reactors (PWR's), common postulation derived from previous studies is that the damage to the alloy substrate can be related to mass transport characteristics and/or repair properties of overlaid oxide film. Recently, it was shown that the oxide film structure and PWSCC initiation time as well as crack growth rate were systematically varied as a function of dissolved hydrogen concentration in high temperature water, supporting the postulation. In order to understand how the oxide film composition can vary with water chemistry, this study was conducted to characterize oxide films on Alloy 600 by an in-situ Raman spectroscopy. Based on both experimental and thermodynamic prediction results, Ni/NiO thermodynamic equilibrium condition was defined as a function of electrochemical potential and temperature. The results agree well with Attanasio et al.'s data by contact electrical resistance measurements. The anomalously high PWSCC growth rate consistently observed in the vicinity of Ni/NiO equilibrium is then attributed to weak thermodynamic stability of NiO. Redox-induced phase transition between Ni metal and NiO may undermine the integrity of NiO and enhance presumably the percolation of oxidizing environment through the oxide film, especially along grain boundaries. The redox-induced grain boundary oxide degradation mechanism has been postulated and will be tested by using the in-situ Raman facility.

SiC 강화 CFRP 복합재의 파괴거동에 관한 음향방출 적용 (AE Application for Fracture Behavior of SiC Reinforced CFRP Composites)

  • 류영록;윤유성;권오헌
    • 한국안전학회지
    • /
    • 제31권3호
    • /
    • pp.16-21
    • /
    • 2016
  • Carbon Fiber Reinforced Plastic(CFRP) composite with a higher specific strength and rigidity is more excellent than conventional metallic materials or other organic polymer of FRP. It has been widely used in vehicles, aerospaces and high technology industries which are associated with nuclear power fields. However, CFRP laminated composite has several disadvantages as like a delamination, matrix brittleness and anisotropic fibers that are the weak points of the crack initiation. In this present work, the reinforced silicon carbide(SiC) particles were added to the interlayer of CFRP laminates in order to mitigate the physical vulnerability affecting the cracking and breaking of the matrix in the CFRP laminated composite because of excellent specific strength and thermal shock resistance characteristics of SiC. The 1wt% of SiC particles were spread into the CFRP prepreg by using a spray coating method. After that, CFRP prepregs were laminated for the specimen. Also, the twill woven type CFRP prepreg was used because it has excellent workability. Thus the mechanical and fracture behaviors of the twill woven CFRP laminated composite reinforced with SiC particles were investigated with the acoustic emission(AE) method under a fracture test. The results show that the SiC particles enhance the mechanical and fracture characteristics of the twill CFRP laminate composite.

석회암공동 상부 기초의 안정성 검토를 위한 모형실험 연구 (Stability Investigation of a Foundation Located above Limestone Cavities Using Scaled Model Tests)

  • 김종우;허석
    • 터널과지하공간
    • /
    • 제26권6호
    • /
    • pp.493-507
    • /
    • 2016
  • 본 연구에서는 축소모형실험을 통해 석회암 공동 상부에 존재하는 구조물 기초의 안정성을 검토하였다. 공동의 형상은 단축장축비율 1/3인 타원형으로 가정하고, 공동의 심도, 위치, 경사, 크기, 개수를 변화시킨 5가지 그룹, 12개 모형들을 실험하였다. 실험결과로서 모형별 균열개시압력, 최대압력, 변형거동, 파괴양상, 침하곡선을 구하였으며, 공동의 제반 조건들이 기초의 안정성에 어떠한 영향을 미치는지를 알아보았다. 무공동 모형은 전단파괴를 보였으나, 공동 포함 모형들은 관입파괴만 발생한 경우, 전단파괴와 관입파괴가 함께 발생한 경우, 전단파괴가 이중으로 발생한 경우 등의 다소 복잡한 파괴형식을 보였다. 공동의 심도가 작을수록, 크기가 클수록, 개수가 많을수록 기초의 안정성은 감소하였다. 공동의 일부가 기초저면의 직하부에 놓일 때는 부등침하가 관찰되었고, 공동들의 분포상태에 따라 침하곡선은 다른 형태를 보였다.

LTCC 기술을 이용한 가스센서 구현 (Realization of gas sensor using LTCC(Low Temperature Cofired Ceramic) technology)

  • 전종인;최혜정;이영범;김광성;박정현;김무영;임채임;문제도
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.369-370
    • /
    • 2005
  • LTCC (Low Temperature Cofired Ceramic) technology is one of technologies which can realize SIP (System-In-a-Package). In this paper realization of gas sensor using LTCC technology was described. In the conventional gas sensor structure, wire bonding method is generally used as an interconnection method whereas in the LTCC sensor structure, via was used for the interconnection. As sensing materials, $SnO_2$ was adopted. The effect of frit glass portion on the adhesion of the sensing material to the LTCC substrate and the electrical conductivity of the sensing material were analyzed. AgPd, PdO, Pt was added to the sensing material as an additive for improving the gas sensitivity and electrical conductivity and the effect of the amount of additives in the sensing material on the electrical conductivity was investigated. The effect of the amount of frit glass in the termination on the sensor performance, especially mechanical integrity, was considered and the crack initiation and propagation in the boundary between the sensing material and the termination was studied.

  • PDF

직접Quenching 열간 단조용 비조질강의 기계적 성질에 미치는 Quenching온도 및 냉각속도의 영향 (Effect of Quenching Temperature and Cooling Rate on the Mechanical Properties of Direct Quenched Micro-Alloyed Steel for Hot Forging)

  • 신정호;류영주;김병옥;고인용;이오연
    • 한국재료학회지
    • /
    • 제22권10호
    • /
    • pp.513-518
    • /
    • 2012
  • Recently, automobile parts have been required to have high strength and toughness to allow for weight lightening or improved stability. But, traditional micro-alloyed steel cannot be applied in automobile parts. In this study, we considered the influence of quenching temperature and cooling rate for specimens fabricated by vacuum induction furnace. Directly quenched micro-alloyed steel for hot forging can be controlled according to its micro structure and the heat-treatment process. Low carbon steel, as well as alloying elements for improvement of strength and toughness, was used to obtain optimized conditions. After hot forging at $1,200^{\circ}C$, the ideal mechanical properties (tensile strength ${\geq}$ 1,000 MPa, Charpy impact value ${\geq}\;100\;J/cm^2$) can be achieved by using optimized conditions (quenching temperature : 925 to $1,050^{\circ}C$, cooling rate : ${\geq}\;5^{\circ}C/sec$). The difference of impact value according to cooling rate can be influenced by the microstructure. A fine lath martensite micro structure is formed at a cooling rate of over $5^{\circ}C/sec$. On the other hand, the second phase of the M-A constituent microstructure is the cause of crack initiation under the cooling rate of $5^{\circ}C/sec$.

Effect of First-Stage Growth Manipulation and Polarity of SiC Substrates on AlN Epilayers Grown Using Plasma-Assisted Molecular Beam Epitaxy

  • Le, Duy Duc;Kim, Dong Yeob;Hong, Soon-Ku
    • 한국재료학회지
    • /
    • 제24권5호
    • /
    • pp.266-270
    • /
    • 2014
  • Aluminum nitride(AlN) films were grown on the C-face and on the Si-face of (0001) silicon carbide(SiC) substrates using plasma-assisted molecular-beam epitaxy(PA-MBE). This study was focused on first-stage growth manipulation prior to the start of AlN growth. Al pre-exposure, N-plasma pre-exposure, and simultaneous exposure(Al and N-plasma) procedures were used in the investigation. In addition, substrate polarity and, first-stage growth manipulation strongly affected the growth and properties of the AlN films. Al pre-exposure on the C-face and on the Si-face of SiC substrates prior to initiation of the AlN growth resulted in the formation of hexagonal hillocks on the surface. However, crack formation was observed on the C-face of SiC substrates without Al pre-exposure. X-ray rocking-curve measurements revealed that the AlN epilayers grown on the Si-face of the SiC showed relatively lower tilt and twist mosaic than did the epilayers grown on the C-face of the SiC. The results from the investigations reported in this paper indicate that the growth conditions on the Si-face of the SiC without Al pre-exposure was highly preferred to obtain the overall high-quality AlN epilayers formed using PA-MBE.

탄소섬유 복합재료의 모드1 및 모드 2 층간파괴인성치에 관한 연구 (A Study on Mode 1 and Mode 2 Interlaminar Fracture Toughness of Carbon Fiber Reinforced Plastics)

  • 김재동;고성위
    • 수산해양기술연구
    • /
    • 제31권3호
    • /
    • pp.272-278
    • /
    • 1995
  • 강도가 각각 다른 세 종류의 프리프레그를 사용하여 일방향 CFRP를 적층하였으며, 모드 I과 모드 II 실험을 통하여 층간 파괴인성치를 고찰하였고, 또한 적층 섬유방향을 변화시킨 사교적층판의 그것도 함께 고찰하였으며, 이를 요약하면 다음과 같다. 1) 임계에너지 방출률 G 하(IC)의 값을 컴플라이언스 법, 수정 컴플라이언스 법, 그리고 보이론에 의해 계산하여 비교 검토한 결과 본 연구에서 사용한 수정식에 의한 값들이 거의 일치하였다. 2) G 하(IC) 값은 대체로 프리프레그의 C, B, A재의 순으로 높게 나타났으며, G 하(II C)의 값을 세가지 식에 의해 계산하여 비교 검토한 결과 거의 일치하였다. 3) 사교적층판의 경우 G 하(IC) 값은 [0/90] 하(6s), [0/45] 하(6s), [0/45/90] 하(6s)의 순으로 높게 나타났으며, G 하(II C)는 [0/90] 하(6s), [0/45/90] 하(6s), [0/45] 하(6s)의 순으로 높게 나타났다. 4) 사교적층판과 일방향의 임계에너지 방출률을 비교하였을 때, 모드 I의 경우 일방향의 결과가 다소 높았으며, 모드 II의 경우는 [0/45] 하(6s)의 결과는 거의 일치함을 알 수 있었다.

  • PDF

척추교정 티타늄 앵커나사 파단 손상원인 분석 (Failure Analysis of Ti alloy Screws in Fixing Fractured Spines)

  • 최병학;김문규;김승언;심윤임;이영진;정효태;최원열
    • 대한금속재료학회지
    • /
    • 제49권12호
    • /
    • pp.983-988
    • /
    • 2011
  • Failure analyses of the screws in spinal fixation devices were carried out. The fractured screws were retrieved from a patient who had spinal surgery in the thoracic vertebrae from number 10 to 15. The failure occurred one month after the removal of the braces. Microstructures and fracture surfaces were examined by optical and scanning electron microscopy. The microstructures of the screws corresponded to annealed Ti-6Al-4V bar. However, in the vicinity of the screw surface, there was an insufficient number of fine precipitates. Fracture surfaces showed typical fatigue failure modes. Regarding the fact that no machining defects were detected, fatigue crack initiation might have been caused by the lack of precipitates near the screw surfaces. Only the fourth of five fixed screws was severely stress-concentrated by the action of the spinal bones, while the stress of the 4th screw was decreased to half of its acceptable level when the screw was supplemented by one more, which might have been fixed in the 6th vertebra under the 5th position by the switching of its position. The stress simulation was conducted by ANSYS with 3D CAD of PRO/E in order to understand the stress concentration behavior and to provide an effective spinal surgery guide.