• Title/Summary/Keyword: Initial operating condition

Search Result 140, Processing Time 0.026 seconds

Commissioning results of the KSTAR helium refrigeration system (KSTAR 저온헬륨설비 시운전 결과)

  • Cho, K.W.;Chang, H.S.;Park, D.S.;Joo, J.J.;Moon, K.M.;Kim, Y.S.;Bak, J.S.;Yang, S.H.;Fauve, E.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.1
    • /
    • pp.64-68
    • /
    • 2009
  • To keep the superconducting (SC) magnet coils of KSTAR at proper operating conditions, not only the coils but also other cold components, such as thermal shields (TS), magnet structures, SC bus-lines (BL), and current leads (CL) must be maintained at their respective cryogenic temperatures. A helium refrigeration system (HRS) with an exergetic equivalent cooling power of 9kW at 4.5K without liquid nitrogen $(LN_2)$ pre-cooling has been manufactured and installed for such purposes. In this proceeding, we will present the commissioning and initial operation results of the KSTAR HRS. Circuits which can simulate the thermal loads and pressure drops corresponding to the cooling channels of each cold component of KSTAR have been integrated into the helium distribution system of the HRS. Using those circuits, the performance and the capability of the HRS, to fulfill the mission of establishing the appropriate operating condition for the KSTAR SC magnet coils, have been successfully demonstrated.

A Study on the Fatigue Crack Evaluation Method of Railway Bogie Frame (철도차량 대차를 피로균열 평가법 연구)

  • Jun, Hyun-Kyu;Seo, Jung-Won;Lee, Dong-Hyong;Kim, Hyeong-Jin
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.1
    • /
    • pp.16-24
    • /
    • 2009
  • In this study, fatigue crack growth rate of a cracked railway bogie frame under variable amplitude loading is predicted by applying linear elastic fracture mechanics. For this purpose, we find the critical points by reference surveying on cracked railway bogie frames. And we make an effective load history by synthesizing the dynamic load measured from the critical points of railway bogie frame during commercial line operation and the static load calculated from structural analysis. Crack growth analyses are performed at the 3 critical points under the commercial operation loading condition by assuming an initial crack size as 40 mm. and the results are compared with the experimental results from Japanese railway bogie frame crack growth case. From the analysis results, we find that around 500,000 km operating distance is necessary to bring crack growth from the initial crack to unstable crack. And it takes around 3.8 normal operating years. We conclude that it is enough time to detect the crack between normal maintenance period.

A Study on the Release Characteristics of VOCs from Heat Recovery Ventilation System (폐열회수형 환기장치의 휘발성유기화함물 배출 특성에 관한 연구)

  • Kwak, Kyung-Min;Bai, Cheol-Ho;Kim, Jee-Yong;Chu, Euy-Sung
    • Clean Technology
    • /
    • v.13 no.4
    • /
    • pp.281-286
    • /
    • 2007
  • VOCs from the heat recovery ventilation system (total heat exchanger) are measured in this study. Two different types of element (L and M type) from heat recovery ventilating system are tested to study the intial release characteristics of VOCs under KS cooling and heating standard conditions. VOCs are measured for the various flow rates and different operating times. Considering errors in the test method and the measuring instrument, the tested heat recovery ventilating systems was found to release 6 major VOCs, such as acetic acid, 2-butanone (MEK), 2-(methylthio )ethylamine, toluene, styrene, and x-acids (Ion 57). The concentrations of released VOCs are not quite much affected by operating conditions. The results show much larger VOCs concentrations in the cooling mode than in the heating mode, due to the high operating temperatures.

  • PDF

Air-Water Countercurrent Flow Limitation in a Horizontal Pipe Connected to an Inclined Riser

  • Kang, Seong-Kwon;Chu, In-Cheol;No, Hee-Cheon;Chun, Moon-Hyun;Sung, Chang-Kyung
    • Nuclear Engineering and Technology
    • /
    • v.31 no.6
    • /
    • pp.548-560
    • /
    • 1999
  • An experimental investigation has been peformed to examine the effects of various geometrical parameters and an initial operating condition on the air-water countercurrent How limitation (CCFL) in a simulated PWR hot leg. A total of 118 experimental data for the onset of CCFL and zero liquid penetration were obtained for various combinations of test parameters. It was observe that the CCFL can be classified into three different categories: (the onset of CCFL, (the partial liquid delivery, and (r) the zero liquid penetration. The observed mechanisms of the onset of CCFL were different depending on the inlet water flow rate. The parametric effects of pipe diameter, horizontal pipe length, horizontal pipe length-to-diameter (L/D) ratio, and initial water level in the horizontal pipe of the test section on the onset of air-water CCFL were also examined. An empirical correlation for the onset of CCFL in a horizontal pipe connected to an inclined riser was developed in terms of Wallis flooding parameters for the low inlet water flow rate region. Comparisons of the present empirical correlation with the air-water CCFL data of large pipe diameters show that the present correlation agrees more closely with the experimental data than the existing CCFL correlations.

  • PDF

The Introduction of Railroad Pass for One Day in Seoul Metro (서울메트로 1일 승차권 도입 방안 연구)

  • Lee, Dong-Wook;Lee, Tai-Sik;Ryu, Jong-Won;Chung, Chul
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1221-1226
    • /
    • 2007
  • The subway with the initial constructive expense which is enormous together is the public transportation means where the many expense is expended in the operation and maintenance civil official. Seoul Metro until initial opening to traffic after present time cannot escape every year deficit to be, the cause is a possibility of seeking from the fare system which is short in transportation prime cost. Currently Seoul Metro is operating with the distance proportional fare system the passenger ticket system which is simple (usual volume, group volume and fixed amount volume, affection renunciation, charge free volume). When the biased characteristic of the user it plans considering from the goods development side for the variety for and a deficit solution, against the fare system systematic it researches and solution plan politically. Financial of the subway operation agency young the investigation against the present condition of the hazard subway fare system which is solved the bud with problem point a fare system from the research which it sees consequently and improvement program under analyzing the man with underdeveloped genital organ. Base on the reporter to analyze the introduction plan which with the character which will reach it follows with the necessity of introduction of the 1st passenger ticket (24 hour volume).

  • PDF

Thermally-induced Mechanical Behavior of the Press-fitted Cylindrical Structure (죄임새 결합된 원통구조물의 열전도에 의한 기계적 특성변화)

  • 김선민;이선규
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.7
    • /
    • pp.139-148
    • /
    • 1998
  • Internal and external heat sources will cause to deform to machine elements in the contact joint of structure, which results in the change of contact pressure distribution different from initial assembly. Heat induced variations of contact pressure will change the static and dynamic properties such as contact stiffness, damping as well as contact heat conduction in the structure In order to design and control the intelligent machine tool operating in variant conditions more sophisticatedly, the good prediction for the changes of prescribed properties are strongly required especially in the contact elements adjacent to the rotational or linear bearing. This paper presents some computational and experimental results in regard to static and dynamic characteristics of the press-fitted bush and shaft assembly which is a model of the bearing innerrace and shaft assembly. In the condition of heat generation on the outer surface of the bush, the effects of changes in the negative clearance and the heat flux on pressure distribution and dynamic properties are investigated. Results of this study show that the edge effect of the bush and the initial clearance have effects on the transient dynamic characteristics significantly.

  • PDF

Preliminary Investigation on Spread-Rebound Regime of an Electrically Charged Droplet (전기적으로 대전된 액적의 스프레드-리바운드 거동 영역에 대한 기초 연구)

  • Ryu, Sung-Uk;Lee, Sang-Yong
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2067-2072
    • /
    • 2007
  • Understanding of the impinging behavior of an electrically charged spray is essential in determining appropriate operating conditions for electro-spraying of paints, surface coating materials and insecticides. In the present work, as an initial step, the wall impact of an electrically charged droplet has been experimentally investigated. The charged drops were directed on the surface of a paraffin wax, and the impinging behavior was visualized and recorded using a CCD camera to identify the impingement regime. The spread-rebound boundary for the charged drop turned out to be smaller compared to that for an electrically neutral droplet under the same surface condition. The shift of the transition criterion is considered to be due to the discrepancy between the maximum spread ratio of the electrically charged droplet and that of the neutral droplet.

  • PDF

A Study on Relationship between Ignition Systems and the Performances of Gasoline Engines (I) (점화시스템의 종류와 가솔린 엔진 성능과의 상관관계에 대한 연구 (I))

  • SunWoo, Myoung-Ho;Song, Jeong-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.966-969
    • /
    • 1998
  • Fast burning achieves higher efficiency, and reduces cycle variations which is able to improve vehicle driveability. Furthermore, the greater resistance to knock with fast burning can allow the fuel economy advantages associated with higher compression ratio to be realized. One way of increasing the combustion speed is to enhance the performance of ignition systems which were able to reduce the early period of combustion. It is well known that shortening the initial stage of combustion also reduces the cyclic variations. This literature survey deals with the papers which have studied the ignition process or various ignition systems. Those systems increasing the combustion speed, extending the lean misfire limit, reducing the exhaust gas and stabilizing the operating condition of the spark ignition engine by modifying the ignition process or increasing ignition energy.

  • PDF

Validation and Development of Artificial Sky Dome Facilities with a Heliodon (인공 천공돔과 헬리오돈의 개발 및 성능실험 사례 연구)

  • Kim, Jeong-Tai;Kim, Gon
    • KIEAE Journal
    • /
    • v.3 no.1
    • /
    • pp.21-29
    • /
    • 2003
  • Scale model measurements should be conducted under an actual sky or in a simulated sky where conditions can be held constant. A number of successful attempts have been made to develop artificial sky domes with man-made sun emulators. With reference to formerly-developed examples, sky simulator facility has recently been activated in oder to provide desirable sky conditions for teaching and studies. The structure is a 6m-diameter dome and promises to set various condition for energy related and lighting research activities. The sky dome is also equipped a heliodon, the tilt table, to facilitate additive direct sun impact under clear skies. Shading studies, using scale models with the heliodon, reveal how a building's design blocks or permits light's passage to the interior; solar access studies, and tests of the reflection and transmittance characteristics of new daylighting technologies. The design and construction specification and the initial operating experience with a building configuration are reported.

Probabilistic Remaining Life Assessment Program for Creep Crack Growth (크리프 균열성장 모델에 대한 확률론적 수명예측 프로그램)

  • Kim, Kun-Young;Shoji, Tetsuo;Kang, Myung-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.6
    • /
    • pp.100-107
    • /
    • 1999
  • This paper describes a probabilistic remaining life assessment program for the creep crack growth. The probabilistic life assessment program is developed to increase the reliability of life assessment. The probabilistic life assessment involves some uncertainties, such as, initial crack size, material properties, and loading condition, and a triangle distribution function is used for random variable generation. The resulting information provides the engineer with an assessment of the probability of structural failure as a function of operating time given the uncertainties in the input data. This study forms basis of the probabilistic life assessment technique and will be extended to other damage mechanisms.

  • PDF