• Title/Summary/Keyword: Initial impoundment

Search Result 6, Processing Time 0.023 seconds

A Study on the Face Slab Deformation of Concrete Faced Rockfill Dams During Initial Impoundment (초기 담수 중 콘크리트 표면차수벽형 석괴댐의 슬래브 거동에 관한 연구)

  • Won, Myoung Soo;Kim, Hyeong Joo;Jung, Young Chae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.1
    • /
    • pp.129-139
    • /
    • 2015
  • Concrete-Face Rock-Fill Dams (CFRDs) are rock-fill dams with watertight-concrete slabs on its upstream slope instead of its central earth cores. The design for CFRDs are still largely empirical and typically based on past experiences. This paper presents a description of the concrete face slabs and leakage behaviors of two post-constructed CFRDs based on the data gathered through instrumentation during the initial impoundment. The results show that the strain on the concrete face slab and the horizontal displacements of the vertical slab joints are slightly affected by both the seasonal temperature change and water loading during the initial impoundment. The deformation of perimetric joints are less affected by the temperature change, however it is significantly affected by the water loading during the initial impoundment. The leakage rate is significantly affected by the hydrostatic load and the deformation of the perimetric joints.

Water Quality Assessment for pre and post-Impoundment of 6 Multipurpose Dam Reservoirs in Korea (국내 6개 다목적댐 저수지의 담수 전·후 수질 비교평가)

  • Park, Jae-Chung;Shin, Jae-Ki;Song, Young-Il;Jeong, Yong-Moon;Song, Sang-Jin
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.1
    • /
    • pp.89-96
    • /
    • 2011
  • This study was carried out to assess the variations of water quality caused by the dam construction on the river. Six dams-Yongdam, Miryang, Hoengseong, Boryeong, Jangheung and Buan- constructed recently in Korea were selected for the study. Chemical oxygen demand(COD) was increased in the initial stage of water storage at dams compared to the lotic(river) environment, but after 3 years it was maintained lower and stabilized concentrations. Five dams except for Jangheung Dam were maintained Ia~Ib grade conditions under the water quality criteria of Korea. The concentrations of total nitrogen(T-N) were decreased under the lentic(reservoir) environment compared to the river status. Total phosphorus(T-P) was decreased 13~63% at the reservoir condition. We concluded that increase of COD concentration was due to the debris organic materials of the land, but temporary phenomenon. T-N and T-P concentrations were decreased at the lentic condition compared to the lotic.

Centrifuge Test for Simulating Behavior of CFRD During Initial Impoundment (초기 담수시 CFRD 거동 모사를 위한 원심모형실험)

  • Seo, Min-Woo;Kim, Yong-Seong
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.10
    • /
    • pp.109-119
    • /
    • 2007
  • As the number of CFRD constructions increases, the necessity of an accurate assessment on its behavior also has been increasing. The performance of concrete faced rockfill dam (CFRD) under different water levels is a great concern of dam engineers and designers in the world. However, domestic research on CFRD design and construction has not been performed sufficiently. This study deals with three centrifuge model tests, mainly investigates quantitatively the deformation of the concrete faced slabs and settlements on the crest with different face slab stiffness. The prototype of a centrifugal model dam is half size of domestic CFRD dam. Detailed material preparation, model design, model set-up, model instrumentation and testing procedures are presented. In order to simulate the prototype concrete faced slab, three kinds of thin fiberglass plates with different thickness were adopted in three model tests. Finally, the centrifuge test results were compared with field measurements of domestic dams, which showed that the centrifuge tests were performed successfully.

An experimental study on tailings deposition characteristics and variation of tailings dam saturation line

  • Wang, Guangjin;Tian, Sen;Hu, Bin;Kong, Xiangyun;Chen, Jie
    • Geomechanics and Engineering
    • /
    • v.23 no.1
    • /
    • pp.85-92
    • /
    • 2020
  • This study adopted soil test and laboratory physical model experiments to simulate the tailings impoundment accumulation process according to the principle of similarity. Relying on the practical engineering, it analyzed the tailings deposition characteristics on dry beach surface during the damming process, as well as the variation rules of dam saturation line. Results suggested that, the tailings particles gradually became finer along the dry beach surface to inside the impoundment. The particle size suddenly changed at the junction between the deposited beach and the water surface, which displayed an obvious coarsening phenomenon. Besides, the deposited beach exhibited the vertical feature of coarse upward and fine downward on the whole. Additionally, in the physical model, the saturation line elevated with the increase in dam height, and its amplitude was relatively obvious within the range of 1.0-4.5 m away from the initial dam. Under flood condition, the saturation line height was higher than that under normal condition on the whole, with the maximum height difference of 4 cm. This study could provide an important theoretical basis for further studies on dam failure experiments and the evolution rules of leaked tailings flow.

Design Optimization of an Ozone Contactor Using Ozone Contactor Model (OCM) Software

  • Kim, Doo-Il;Lee, Chae-Young;Joe, Woo-Hyeun;Lee, Seock-Heon
    • Environmental Engineering Research
    • /
    • v.14 no.4
    • /
    • pp.244-249
    • /
    • 2009
  • Designing an ozone contactor is complicated because the residual ozone, log C. parvum inactivation, and bromate formation should be optimized with fluctuating water quality. OCM software was developed to assist a plant designer or an operator to fulfill the sophisticated optimization required in the design or operation of a new or an existing plant. In this article, numerical simulations were carried out using the OCM software for the design of a new ozone contactor under diverse design factors (i.e., three pHs, three temperatures, low and high dispersion numbers, and four and ten cells with complete mixing) with kinetic parameters obtained from the sand-filter effluent of a water treatment plant treating water from the Paldang impoundment. The results of the simulation suggested that a high residual ozone concentration at low pH and low temperature would be challenging, and PFR-like hydrodynamics could lower the residual ozone concentration. The inactivation of C. parvum oocysts increased at a lower pH. A lower dispersion number and more cell division increased the inactivation efficiency. Bromate was instantaneously formed during the initial ozonation stage. The effluent concentration was much lower than the regulatory levels imposed by the USEPA because of the low bromide level in raw water.

Water-Blooms (Green-Tide) Dynamics of Algae Alert System and Rainfall-Hydrological Effects in Daecheong Reservoir, Korea (대청호 조류경보제의 녹조현상 동태와 강우-수문학적 영향)

  • Shin, Jae-Ki;Kang, Bok-Gyoo;Hwang, Soon-Jin
    • Korean Journal of Ecology and Environment
    • /
    • v.49 no.3
    • /
    • pp.153-175
    • /
    • 2016
  • Daecheong Reservoir has suffered eutrophication and water-blooms by blue-green algae from initial impoundment, and algae alert system (AAS) was introduced in 1997. The purpose of this study was to investigate the effect of rainfall and hydrological factors in increase or decrease variability of green-tide and prolonged AAS, studied and analyzed the current situation of AAS has been operating for 19 years (1997~2015) in Daecheong Reservoir. The total issued number of AAS was 46 times, the most frequent period in August and September were 22 times (752 days) and 16 times (431 days), respectively, it accounted for 82.6%. Many number and frequency during this period were significantly associated with rainfall, various discharge and water level. Rainfall and hydrological events are associated with the rainy season of monsoon-Changma and the typhoon, it was concentrated in June~September, total rainfall in this period accounted for 69.9% of the annual rainfall. An increase in inflows was dependent on the intensity, frequency and the amount of rainfall. Accounted for 68.4% of the total annual inflow, it was a time when the most rapidly changing hydrological variability in the reservoir. The total outflow was closely related to rainfall, and compared the distinctive characteristics of hydropower generation and watergate-spillway discharge. In addition, the upreservoir zone of Daecheong Reservoir could be vulnerable to green-tide by regulating discharge of the upstream dam. The issue of AAS was strongly related to the with and without of watergate-spillway discharge. The watergate-spillway discharge had a total of 25 times, it was maximum 17 days from July to September in the year. And the opening times and each duration of the watergate were 1~4 times and the range of 3~37 days, respectively. When the watergate opened, the issue of AAS was maintained to 13 years and the movement of water bodies and green-tide was great about five times than that of non-open, had a profound effect on prolonged AAS within reservoir. In Daecheong Reservoir, Chusori (CHU) area of the So-ok Stream was still showing serious symptoms green-tide levels in the summer, but Janggye (JAN) waters of the main reservoir was pointed out that more important. AAS will be operated by an absolutely consider the rainfall and hydrological effects around the watergate-spillway discharge. The measures of green-tide will be included in the limnological studies more suited to the characteristics of the watershed and reservoir of the our country. Finally, from now on, we will prepare the systematic management and guidelines for vulnerable zone water-blooms that are the source within the reservoir before the monsoon rather than waiting for the arrival of green-tide on the operating stations of AAS.