• Title/Summary/Keyword: Initial drug resistance

Search Result 41, Processing Time 0.024 seconds

Function identification of bovine Nramp1 promoter and intron 1

  • Hao, Linlin;Zhang, Libo;Li, Mingtang;Nan, Wang;Liu, Songcai;Zhong, Jifeng
    • Animal cells and systems
    • /
    • v.15 no.3
    • /
    • pp.227-233
    • /
    • 2011
  • The Nramp1/Slc11a1 locus encodes a proton-coupled divalent cation transporter, expressed in late endosomes/lysosomes of macrophages, that constitutes a component of the innate immune response to combat intracellular pathogens and it was shown to play an important role in regulating inherent immunity. The previously identified Z-DNA forming polymorphic repeat(GT)n in the promoter region of the human Nramp1 gene does act as a functional polymorphism influencing gene expression. Research has shown that INF-${\gamma}$, TNF-${\alpha}$, IL-$1{\beta}$ and bacteria LPS increase the level of Nramp1 expression. However, the molecular mechanism for Nramp1 gene regulation is unclear. In this research, bovine Nramp1 5'-flanking region (-1748~+769) was cloned and analyzed by bioinformatics. Then to find the core promoter and the cis-acting elements, deletion analysis of promoter was performed using a set of luciferase reporter gene constructs containing successive deletions of the bovine Nramp1 5'-flanking regions. Promoter activity analysis by the dual luciferase reporter assay system showed that the core promoter of Nramp1 was located at +58~-89 bp. Some positive regulatory elements are located at -89~-205 bp and -278~-1495 bp. And the repressor elements were in region -205~-278 bp, intron1 and -1495~-1748 bp. LPS-responsive regions were located at -1495~-1748 bp and -278~-205 bp. The present study provides an initial effort to explore the molecular mechanism of transcriptional activation of the bovine Nramp1 gene and should facilitate further studies to decode the complex regulatory process and for molecular breeding for disease resistance in bovines.

Pretreatment Neutrophil-to-Lymphocyte Ratio and Smoking History as Prognostic Factors in Advanced Non-Small Cell Lung Cancer Patients Treated with Osimertinib

  • Park, Ji Young;Jang, Seung Hun;Lee, Chang Youl;Kim, Taehee;Chung, Soo Jie;Lee, Ye Jin;Kim, Hwan Il;Kim, Joo-Hee;Park, Sunghoon;Hwang, Yong Il;Jung, Ki-Suck
    • Tuberculosis and Respiratory Diseases
    • /
    • v.85 no.2
    • /
    • pp.155-164
    • /
    • 2022
  • Background: The remarkable efficacy of osimertinib in non-small cell lung cancer (NSCLC) with acquired T790M mutation has been widely documented in clinical trials and real-world practice. However, some patients show primary resistance to this drug. Even patients who initially show a favorable response have inconsistent clinical outcomes later. Therefore, the aim of this study was to identify additional clinical predictive factors for osimertinib efficacy. Methods: A prospective cohort of patients with acquired T790M positive stage IV lung adenocarcinoma treated with osimertinib salvage therapy in Hallym University Medical Center were analyzed. Results: Sixty-one eligible patients were analyzed, including 38 (62%) women and 39 (64%) who never smoked. Their mean age was 63.3 years. The median follow-up after treatment with epidermal growth factor receptor (EGFR) tyrosine kinase inhibitors (TKIs) was 36.0 months (interquartile range, 24.7-50.2 months). The majority (n=45, 74%) of patients were deceased. Based on univariate analysis, low baseline neutrophil-to-lymphocyte ratios (NLR), age ≥50 years, never-smoking history, stage IVA at osimertinib initiation, and prolonged response to previous TKIs (≥10 months) were associated with a significantly longer progression-free survival (PFS). Multivariate analysis showed that never-smoking status (hazard ratio [HR], 0.54; 95% confidence interval [CI], 0.30-0.98; p=0.041) and a baseline NLR less than or equal to 3.5 (HR, 0.23; 95% CI, 0.12-0.45; p<0.001) were independently associated with a prolonged PFS with osimertinib. Conclusion: Smoking history and high NLR were independent negative predictors of osimertinib PFS in patients with advanced NSCLC developing EGFR T790M resistance after the initial EGFR-TKI treatment.

The Etiologic Agents and Clinical Outcomes of Adult Community-acquired Pneumonia in Jeju (제주지역 성인 지역사회획득 폐렴의 원인균 및 임상양상)

  • Jeon, Bong-Hee;Kim, Miok;Kim, Jeong Hong;Shin, Sang Yop;Lee, Jaechun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.66 no.5
    • /
    • pp.358-364
    • /
    • 2009
  • Background: The appropriate empirical antimicrobial choice in the treatment of community-acquired pneumonia (CAP) should be advocated by community-based information on the etiologic pathogens, their susceptibility to antimicrobials, clinical characteristics and outcomes. Jeju is a geographically isolated and identical region in Korea. However, there is no regional reference on adult CAP available. This study investigated the etiologic agents and clinical outcomes of adult patients diagnosed with CAP in Jeju, Korea, to help guide the empirical antimicrobial choice. Methods: A prospective observational study for one year in a referral hospital in Jeju, Korea. Patients diagnosed with CAP were enrolled with their clinical characteristics. Microbiological evaluations to identify the etiologic agents in the adult patients with CAP were performed with blood culture, expectorated sputum smear and culture, antibody tests for mycoplasma, chlamydophila, and antigen tests for legionella and pneumococcus. The clinical outcomes of the initial empirical treatment were analyzed. Results: Two hundred and three patients with mean age of 64 and 79 females were enrolled. Ten microbials from 90 cases (44.3%) were isolated and multiple isolates were confirmed in 30. Among the microbial isolates, S. pneumoniae (36.3%) was the most common, followed by M. pneumoniae (23.0%), C. pneumoniae (17.0%), S. aureus (9.6%) and P. aeruginosa (5.9%). The initial treatment failure (23.8%) was related to the isolation of polymicrobial pathogens, elevated inflammatory markers, and the presence of pleural effusion. Among the 30 isolates of S. pneumoniae, 16 (53.3%) were not susceptible to penicillin, and 19 isolates (63.3%) to erythromycin and clarithromycin. However, 29 isolates (96.7%) were susceptible to levofloxacin and ceftriaxone. Conclusion: S. pneumoniae, M. pneumoniae, S. aureus, and P. aeruginosa are frequent etiologic agents of adult CAP in Jeju, Korea. The clinical characteristics and antibiotic resistance should be considered when determining the initial empirical antimicrobial choice. Respiratory quinolone or ceftriaxone is recommended as an empirical antimicrobiotic in the treatment of adult CAP in Jeju, Korea.

The Difference of History Associated with Occupation of Pulmonary Tuberculosis (폐결핵 환자의 직업에 따른 병력의 차이)

  • Song, Sun-Dae;Kim, Cheon-Tae;Koh, Seok-Shin
    • Journal of agricultural medicine and community health
    • /
    • v.20 no.2
    • /
    • pp.149-156
    • /
    • 1995
  • This study was performed for 182 rural persons of patients who had admitted at National Masan Tuberculosis Hospital from 21th Feb to 18th Aug, 1994. We investigated diseased history based on the data according to the kind of occupation. The results were summarized as follows : The most common occupation was no occupation(35.2%). The most common age group was 5th decade(25.3%). By the age, the most common group in cases of no occupation was over 7th decade and under 5th decade, and agriculture was over 7th decade and 6th decade. Male(83.5%) were more than female, but wasn't significantly different. The most common group in the level of education was over the graduate of high school. The group that have ever drunken(p<0.05) and smoked(p<0.01) was significantly different in labour, service, agriculture, others. Family history, combined disease, symptom were no significantly different by occupation. Both lung fields on the chest X-ray was the most common site of invasion(82.4%). In the tests of AFB smear and culture, the differences according to the occupation were not. At the time of admission, the most common group in the state of treatment was initial treatment. The multi-drug resistance tuberculosis was no significantly different by occupation.

  • PDF

Effects of Dynamic Tubing Gait Training on Postural Alignment, Gait, and Quality of Life in Chronic Patients with Parkinson's Disease : Case Study (동적탄력튜빙 보행훈련 프로그램이 만성 파킨슨병 환자의 자세정렬과 보행능력과 삶의 질에 미치는 영향 : 사례연구)

  • Lee, Dong-Ryul
    • Journal of Korea Entertainment Industry Association
    • /
    • v.15 no.8
    • /
    • pp.363-377
    • /
    • 2021
  • The present study investigated the effects of dynamic tubing gait training(I and II) on the postural alignment, gait, and quality of life in chronic patients with Parkinson's disease. This study is based on the case study that recruited a total of 3 patients with chronic Parkinson's disease (Hoehn and Yahr Stage of 1 to 3 each one person). Dynamic tubing gait training (I and II) applied to chronic patients with Parkinson's disease for 25 sessions, 30 minutes a day, 5 days a week, over 5 weeks period. To investigate the effects of this study, evaluating using the postural alignment test, muscle activity tests, gait analysis, and quality of life scale for patient with Parkinson's disease. After the intervention of Dynamic tubing gait training (I and II), Trunk flexion was decreased. Also, during walking from initial contact (IC) to mid stance (Mst), muscle activity of Quadriceps, Hamstring, and Tibialis Anterior (TA) was increased and muscle activity of Gastrocnemius was decreased. The muscle activation of Erector Spinae (ES T12, L3) was increased in the H&Y I and III stages and decreased in the H&Y II stage. Length of gait line, single support line, ant/post position and lateral symmetry of center of pressure (COP) parameters improved. The spatio-temporal gait parameters including of step length, stride length, and velocity was increased, and cadence decreased. Further the quality of life of patients with Parkinson's disease was improved. Based on these findings, Dynamic tubing gait training (I and II) could be applied as a new approach to improve posture, gait, quality of life in chronic patients with Parkinson's disease for more than 5 years, whose drug resistance is halved.

6-Month Short-Course Chemotherapy for Tuberculous Pleural Effusion (결핵성 흉막염에서의 6개월 단기 치료)

  • Kim, Tae-Hyung;Kim, Kyoung-A;Lim, Chae-Man;Lee, Sang-Do;Koh, Youn-Suck;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.3
    • /
    • pp.509-518
    • /
    • 1998
  • Background: Short-course chemotherapy for 6 months is well established for pulmonary tuberculosis. However, little is known about the efficacy of the short-course chemotherapy for tuberculous pleural effusion. Tuberculous pleural effusion itself may be self-limiting without any treatment, but about two thirds of the patients with tuberculous pleural effusion may subsequently develop pulmonary tuberculosis within 5 years. After completing treatment for tuberculous pleural effusion. prolonged follow-up is necessary for evaluating the efficacy of the treatment There is still no report on the efficacy of 6-month regimens for tuberculous pleural effusion in Korea, where the incidence of tuberculous disease and drug resistance is high. We studied the efficacy of 6 month short-course chemotherapy comparing with 9 month chemotherapy. Method : Retrospective study was done through medical record review in 238 patients with tuberculous pleural effusion who admitted to Asan Medical Center during May 1989-May 1993. The diagnosis of tuberculous pleural effusion was made by bacteriologic or histopathologic study. Results: Among 238 patients, 38 patients were dropped out during follow-up period. In 2 patients, second line drugs were prescribed according to known drug resistance results. And, in 23 patients, treatment longer than 9 months was done due to accompanying extrapulmonary tuberculosis or durg resistance. In 8 patients, treatment regimen was changed due to hepatotoxicity. Remaining 167 cases (70.2%) completed the treatment as scheduled ; 6 month chemotherapy in 88 cases and 9 month chemotherapy in 79 cases. In 60 patients (35.9%) with pleural effusion only in chest X-ray finding, sputum smear or culture for M.tuberculosis was positive in 6 cases (10.0%), and in 63 patients (37.7%) with radiologically inactive pulmonary tuberculosis, sputum smear or culture was positive in 18 cases (28.6%). In 44 patients (26.3%) with radiologically active pulmonary tuberculosis, the sputum smear or culture was positive in 24 cases (54.5%). In 6-month chemotherapy group (n=88), during mean 23 months (range; 1~61months) follow-up period, pulmonary tuberculosis developed in 1 case (1.4%). In 9-month chemotherapy group(n=79), during mean 23 months (range; 3~70months) follow-up period, pulmonary tuberculosis developed in 2 cases (2.5%). All the cases who developed pulmonary tuberculosis also showed active pulmonary tuberculosis on initial chest X-ray before treatment Conclusion: In patients with tuberculous pleural effusion, the incidence of pulmonary tuberculosis after 6 month chemotherapy showed no difference from that after 9 month chemotherapy. Thus, 6 month short-course chemotherapy seems to be an effective treatment for tuberculous pleural effusion.

  • PDF

The Short Term Efficacy of Entecavir Therapy in Chronic Hepatitis B (만성 B형 간염 환자에서 엔테카비어의 단기 치료 효과)

  • Kim, Hyun;Chae, Hee-Bok;Jeon, Won-Joong;Park, Seon-Mee;Youn, Sei-Jin;Eun, Jong-Ryul;Lee, Heon-Ju
    • Journal of Yeungnam Medical Science
    • /
    • v.25 no.1
    • /
    • pp.31-40
    • /
    • 2008
  • Background/Aims : Entecavir is a synthetic nucleoside analogue, cyclopentyl guanine nucleoside, which has a potent antiviral effect and the least viral breakthrough in hepatitis B virus (HBV) replication. Entecavir has been available in Korea since 2007 but there are few reports on its effects. The aim of this study was to evaluate the virological response (VR) and biochemical response (BR) to entecavir in HBV patients at 3, 6 and 9 months after treatment with entecavir. Materials and Methods : Thirty-three chronic hepatitis B patients who took entecavir for at least 9 months were enrolled. We investigated VR and BR by retrospectively reviewing medical records. Patients who satisfied the following criteria were chosen: 1) initial alanine aminotransferase (ALT) levels = 1.5upper limit of normal (ULN) and 2) initial HBV DNA levels = $5\;log_{10}\;copies/ml$. We measured ALT levels every 3 months until month 9. HBV DNA was measured every 2 or 3 months by polymerase chain reaction (PCR) method. Results : Most patients taking entecavir showed good BR (ALT < 40 IU/L). The BR rates were 61%, 73% and 67% at months 3, 6 and 9, respectively. VR (HBV DNA < $5\;log_{10}\;copies/ml$ or 2 log lower than initial HBV DNA) rates were 82%, 91% and 91% at months 3, 6 and 9, respectively. Undetectable HBV DNA (HBV DNA < 4 log10 copies/ml) rates were 49%, 73% and 85% at months 3, 6 and 9, respectively. Two patients presented with virological breakthrough without adverse effects until month 9. Conclusions : Entecavir showed good BR and VR from month 3 and these effects continued through the 9-month observation period. This suggests that entecavir is also a good choice for the first line treatment of chronic hepatitis B (CHB). Further studies are needed to determine the long-term efficacy and drug resistance of entecavir in Korean CHB patients.

  • PDF

Enhancement of Sensitivity of Human Lung Cancer Cell Line to TRAIL and Gefitinib by IGF-1R Blockade (폐암세포주에서 IGF-1R 억제를 이용한 TRAIL 및 gefitinib에 대한 감수성 증가를 위한 연구)

  • Lee, Yoon-Jin;Park, Mi-Young;Kang, Young-Ae;Kwon, Sung-Youn;Yoon, Ho-Il;Lee, Jae-Ho;Lee, Choon-Taek
    • Tuberculosis and Respiratory Diseases
    • /
    • v.63 no.1
    • /
    • pp.42-51
    • /
    • 2007
  • Background: TRAIL is a cytokine that selectively induces apoptosis in various cancer cell lines. Gefitinib is new targeted drug applied in lung cancer that selectively inhibits EGFR tyrosine kinase. However, lung cancers have shown an initial or acquired resistance to these drugs. This study examined the effect of IGF-1R and its blockade on enhancing the sensitivity of lung cancer cell lines to TRAIL and gefitinib. Methods: Two lung cancer cell lines were used in this study. NCI H460 is very sensitive to TRAIL and gefitinib. On the other hand, A549 shows moderate resistance to TRAIL and gefitinib. The IGF-1R blockade was performed using adenoviruses expressing the dominant negative IGF-1R and shRNA to IGF-1R and AG1024 (IGF-1R tyrosine kinase inhibitor). Results: The adenovirus expressing dominant negative IGF-1R(950st) induced the increased expression of defective IGF-1R on the lung cancer cell surface, and the adenovirus-shIGF-1R effectively decreased the level of IGF-1R expression on cell surface. The genetic blockade of IGF-1R by the adenovirus-dnIGF-1R and AG1024 increased the sensitivity of A549 cells to TRAIL. The reduction of IGF-1R by transduction with ad-shIGF-1R also increased the sensitivity of the A549 cells to gefitinib. Conclusion: The blockade of IGF-1R through various mechanisms increased the sensitivity of the lung cancer cell line that was resistant to TRAIL and gefitinib. However, further studies using other cell lines showing acquired resistance as well as in vivo animal experiments will be needed.

Bibliographic Study on the Therapy of Lung Cancer by Integrated Oriental and Western Medicine (폐암(肺癌)의 동서의결합치료(東西醫結合治療)에 관(關)한 문헌적(文獻的) 고찰(考察))

  • Whang, Choong-Yeon
    • The Journal of Korean Medicine
    • /
    • v.16 no.2 s.30
    • /
    • pp.177-194
    • /
    • 1995
  • The following conclusions were obtained after bibliographic investigation on the therapy of lung cancer by western, oriental, and integrated oriental and western medicine. 1. Lung cancer is classified into small cell lung cancer(SCLC) or non small cell lung cancer(NSCLC) in the treatment by western medicine, and applied with the means of surgery, radiotherapy and chemotherapy alone or combined, depending on the stage and the symptom. 2. Treatment by oriental medicine includes the means of strengthening body resistance to dispel pathogenic factors(扶正祛邪), combined approach of reinforcement and expulsion(攻補兼施), and reinforcing both qi and blood(氣血雙補), depending on the initial, middle, and terminal stage. And also treatment based on differentiation of symptom(辨證施治) is applied according to the type of symptom; deficiency of qi of both lung and spleen(肺脾氣虛), heat symptom of lung by deficiency of yin(肺熱陰虛), stagnation of damp-phlegm and blood(濕痰瘀阻), stagnation of qi and blood(氣血瘀滯), deficiency of both qi and yin(氣陰兩虛). Single or combined herb drug is used according to the symptom. 3. Treatment by integrated oriental and western medicine improved survival rate and quality of life. It promoted recovery and improved survival rate in the patients receiving surgery. Integrated radiotherapy and oriental medicine treatment reduced adverse effect by radiotherapy and improved therapeutic effect and survival rate. Integrated chemotherapy with oriental medicine treatment reduced side effect by chemotherapy and improved quality of life and survival rate. These results suggest that therapy of lung cancer should be applied with integrated oriental and western medicine from diagnosis to treatment for promoting therapeutic effect. And further study on this therapy should be ensued.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF