• Title/Summary/Keyword: Initial center

Search Result 3,408, Processing Time 0.033 seconds

Design and Characteristics Analysis of the 78 kWe Grade Synchronous Generator for Disused Diesel Engines

  • Youn, Jun-Seop;Kim, Hae-Joong;Kim, Youn-Hwan;Moon, Jae-Won
    • Journal of Magnetics
    • /
    • v.22 no.1
    • /
    • pp.122-132
    • /
    • 2017
  • This study dealt with the design process of the 78 kW permanent magnet synchronous generator for engines. After the calculation of the basic dimensions through a theoretical method in the process of initial model design, FEA (finite-element analysis) and a d,q-axis equivalent circuit were used to identify the generator characteristics depending on the number of poles. With the use of the space harmonic analysis method, the back-EMF (electromotive force) and THD were checked, and then the number of slots was determined. In addition, the most optimized generator dimensions were determined through a sizing optimization technique. Based on this, the optimum model with enhanced efficiency, material costs, and temperature characteristics was derived, and the availability of the design method was confirmed through a comparative analysis of the initial and optimum models.

Initial Growth of Nb on Cu(100) studied by STM and Density Functional Theory

  • Lee, Joon-Hee;Ryang, Kyung-Deuk;Son, Chul-Woo;Lyo, In-Whon;Kang, Jin-Ho;Kang, Myung-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.159-159
    • /
    • 2000
  • Initial growth mode of Nb on Cu(100) is studied by scanning tunneling microscopy (STM) and density functional theory. Nb/Cu is immiscible at room temperature, but isolated Nb atoms are expected to be incorporated up to the second layer by DFT. STM shows that Nb atoms mix with Cu atoms in the first layer at room temperature and diffuse into the second layer upon annealing. In the second layer, Nb/induced features are preferentially found at step edges and appear as bright dots surrounded by dark rings. Details of comparison between experiment and theory will be discussed.

  • PDF

Outcomes of open neck injuries

  • Noh, Dongsub;Choi, Jin Ho
    • Journal of Trauma and Injury
    • /
    • v.35 no.3
    • /
    • pp.168-172
    • /
    • 2022
  • Purpose: The neck is a particularly critical region for penetrating injuries due to the close proximity of the trachea, esophagus, blood vessels, and the spinal cord. An open neck injury has the potential for serious morbidity and mortality. The purpose of this study is to evaluate the assessment and management of open neck injuries. Methods: In this retrospective study, open neck injury patients who were admitted to the Trauma Center of Daejeon Eulji Medical Center, Eulji University between December 2015 and December 2017 were analyzed for epidemiology, the mechanism of trauma, the injured organ, complications, and mortality. Results: Thirty-two patients presented with open neck injuries. All patients underwent computed tomographic angiography to evaluate their injuries once their vital signs stabilized. Among these patients, 27 required surgical treatment. The most commonly injured organ was the airway. There were five deaths, and the main cause of death was bleeding. Mortality was associated with the initial systolic blood pressure at the hospital and Glasgow Coma Scale. Conclusions: Mortality from open neck injuries was associated with initial systolic blood pressure at the hospital and Glasgow Coma Scale.

Clinical Factors and Perioperative Strategies Associated with Outcome in Preinjury Antiplatelet and Anticoagulation Therapy for Patients with Traumatic Brain Injuries

  • Pang, Chang Hwan;Lee, Soo Eon;Yoo, Heon
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.3
    • /
    • pp.262-270
    • /
    • 2015
  • Objective : Long-term oral anticoagulation or antiplatelet therapy has been used with increasing frequency in the elderly. These patients are at increased risk of morbidity and mortality from expansion of intracranial hemorrhage. We conducted a single-center retrospective case control study to evaluate risk factors associated with outcomes and to identify the differences in outcome in traumatic brain injury between preinjury anticoagulation use and without anticoagulation. Methods : A retrospective study of patients who underwent craniotomy or craniectomy for acute traumatic cerebral hemorrhage, between January 2005 and December 2014 was performed. Results : A consecutive series of 50 patients were evaluated. The factors significantly differed between the two groups were initial Prothrombin Time-International Normalized Ratio, initial platelet count, initial Glasgow Coma Scale score, and postoperative intracranial bleeding. Mean Glasgow Outcome Scale (GOS) score were similar between the two groups. In the patient with low-energy trauma only, no significant differences in GOS score, postoperative bleeding and many other factors were observed. The contributing factors to postoperative bleeding was preinjury anticoagulation and its adjusted odds ratio was 12 [adjusted odds ratio (OR), 12.242; p=0.0070]. The contributing factors to low GOS scores, which mean unfavorable neurological outcomes, were age (adjusted OR, 1.073; p=0.039) and Rotterdam scale score for CT scans (adjusted OR, 3.123; p=0.0020). Conclusion : Preinjury anticoagulation therapy contributed significantly to the occurrence of postoperative bleeding. However, preinjury anticoagulation therapy in the patients with low-energy trauma did not contribute to the poor clinical outcomes or total hospital stay. Careful attention should be given to older patients and severity of hemorrhage on initial brain CT.

Effects of Emphasized Initial Contact Auditory Feedback Gait Training on Balance and Gait in Stroke Patients (뇌졸중 환자의 초기 접지기를 강조한 청각적-피드백 보행훈련이 균형능력과 보행기능에 미치는 영향)

  • Kim, Jung-Doo;Cha, Yong-Jun;Youn, Hye-Jin
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.10 no.4
    • /
    • pp.49-57
    • /
    • 2015
  • PURPOSE: This study aimed to investigate the effect of emphasized initial contact gait training on balance and gait ability in hemiplegia patients. METHODS: Twenty-four hemiplegic patients were randomly allocated to an experimental group or control group. All participants received 30-min neurodevelopmental treatment. Furthermore, the experimental group received initial contact-emphasized auditory feedback gait training, whereas the control group received gait training without auditory feedback. The intervention was performed 3 times per week, 20 min per each time, for a total of 6 weeks. Balance was assessed using the center of pressure path length, center of pressure velocity, and limitation of stability path length, whereas gait ability was assessed using the 10-m walking test and functional gait assessment. RESULTS: In both groups, center of pressure path length and center of pressure velocity significantly decreased after training. Compared to the control group, the experimental group showed a 10% significant improvement (p<.05). In the limitation of stability path length of both sides, the experimental group showed a significant increase compared to that before intervention. Compared to the control group, the experimental group showed a 7% significant improvement in results of the 10-m walking test and functional gait assessment (p<.05). CONCLUSION: Emphasized Initial contact gait training is considered an effective treatment for improving gait ability and balance ability in stroke patients.

Initial Firing Angle Control of Parallel Multi-Pulse Thyristor Dual Converter for Urban Railway Power Substations

  • Kim, Sung-An;Han, Sung-Wo;Cho, Yun-Hyun
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.674-682
    • /
    • 2017
  • This paper presents an optimal initial firing angle control based on the energy consumption and regenerative energy of a parallel multi-pulse thyristor dual converter for urban railway power substations. To prevent short circuiting the thyristor dual converter, a hysteresis band for maintaining a zero-current discontinuous section (ZCDS) is essential during mode changes. During conversion from the ZCDS to forward or reverse mode, the DC trolley voltage can be stabilized by selecting the optimal initial firing angle without an overshoot and slow response. However, the optimal initial firing angle is different depending on the line impedance of each converter. Therefore, the control algorithm for tracking the optimal initial firing angle is proposed to eliminate the overshoot and slow response of DC trolley voltage. Simulations and experiments show that the proposed algorithm yields the fastest DC voltage control performance in the transient state by tracking the optimal firing angle.

Finding an initial solution and modifying search direction by the centering force in the primal-dual interior point method (원쌍대 내부점기법에서 초기해 선정과 중심화 힘을 이용한 개선 방향의 수정)

  • 성명기;박순달
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1996.04a
    • /
    • pp.530-533
    • /
    • 1996
  • This paper deals with finding an initial solution and modifying search direction by the centrering force in the predictor-corrector method which is a variant of the primal-dual barrier method. These methods were tested with NETLIB problems. Initial solutions which are located close to the center of the feasible set lower the number of iterations, as they enlarge the step length. Three heuristic methods to find such initial solution are suggested. The new methods reduce the average number of iterations by 52% to at most, compared with the old method assigning 1 to initial valurs. Solutions can move closer to the central path fast by enlarging the centering force in early steps. It enlarge the step length, so reduces the number of iterations. The more effective this method is the closer the initial solution is to the boundary of the feasible set.

  • PDF

Changes of Cytosolic $Ca^{2+}$ under Metabolic Inhibition in Isolated Rat Ventricular Myocytes

  • Kang, Sung-Hyun;Kim, Na-Ri;Joo, Hyun;Youm, Jae-Boum;Park, Won-Sun;Warda, Mohamed;Kim, Hyung-Kyu;Von Cuong, Dang;Kim, Tae-Ho;Kim, Eui-Yong;Han, Jin
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.9 no.5
    • /
    • pp.291-298
    • /
    • 2005
  • To characterize cytosolic $Ca^{2+}$ fluctuations under metabolic inhibition, rat ventricular myocytes were exposed to $200{\mu}M$ 2,4-dinitrophenol (DNP), and mitochondrial $Ca^{2+}$, mitochondrial membrane potential (${\Delta}{\Psi}m$), and cytosolic $Ca^{2+}$ were measured, using Rhod-2 AM, TMRE, and Fluo-4 AM fluorescent dyes, respectively, by Laser Scanning Confocal Microscopy (LSCM). Furthermore, the role of sarcolemmal $Na^+$/$Ca^{2+}$ exchange (NCX) in cytosolic $Ca^{2+}$ efflux was studied in KB-R7943 and $Na^+$-free normal Tyrode's solution (143 mM LiCl ). When DNP was applied to cells loaded with Fluo-4 AM, Fluo-4 AM fluorescence intensity initially increased by $70{\pm}10$% within $70{\pm}10$ s, and later by $400{\pm}200$% at $850{\pm}45$ s. Fluorescence intensity of both Rhod-2 AM and TMRE were initially decreased by DNP, coincident with the initial increase of Fluo-4 AM fluorescence intensity. When sarcoplasmic reticulum (SR) $Ca^{2+}$ was depleted by $1{\mu}M thapsigargin plus $10{\mu}M ryanodine, the initial increase of Fluo-4 AM fluorescence intensity was unaffected, however, the subsequent progressive increase was abolished. KB-R7943 delayed both the first and the second phases of cytosolic $Ca^{2+}$ overload, while $Na^+$-free solution accelerated the second. The above results suggest that: 1) the initial rise in cytosolic $Ca^{2+}$ under DNP results from mitochondrial depolarization; 2) the secondary increase is caused by progressive $Ca^{2+}$ release from SR; 3) NCX plays an important role in transient cytosolic $Ca^{2+}$ shifts under metabolic inhibition with DNP.

In Situ Observation of Initial Rusting Process of Steel Containing Al Using Synchrotron Radiation X-Rays

  • Morimoto, J.;Yamashita, M.;Uchida, H.;Doi, T.;Kamimura, T.;Miyuki, H.;Konishi, H.;Mizuki, J.
    • Corrosion Science and Technology
    • /
    • v.7 no.2
    • /
    • pp.112-118
    • /
    • 2008
  • We observed initial rusting process of steel containing Al under wet/dry cyclic condition with NaCl solution film using in situ X-ray diffraction spectroscopy at SPring-8 synchrotron radiation facility. It was found that mass fraction of iron oxides such as ${\alpha}-FeOOH$, ${\beta}-FeOOH$ and ${\gamma}-FeOOH$ varied with Al content. Some kinds of Al oxides were also found at the initial stage of corrosion. Those corrosion products might affect the corrosion process and corrosion rate of the steel.

Single-axis Flat Electro-Magnetic Actuator using Shorted Turn for Fast Initial Response (평판형 전자기 엑츄에이터의 초기응답속도 향상을 위한 쇼티트 턴에 관한 연구)

  • Hwang, Ki-Il;Kim, Jin-Ho
    • Journal of the Korean Magnetics Society
    • /
    • v.19 no.6
    • /
    • pp.222-226
    • /
    • 2009
  • This paper presents the new design of flat electromagnetic actuator. Novel shorted turn and copper center pole are placed into existent design in order to reduce the inductance of coil and accelerate the initial response. Finite element analysis using commercial electromagnetic solver “MAXWELL” is performed to simulate the improvement of dynamic characteristics such as fast initial response and so on.