• Title/Summary/Keyword: Initial Velocity

Search Result 1,086, Processing Time 0.023 seconds

Histopathological and Neurobehavioral Characterization in Adult Mice Exposed to Traumatic Brain Injury (C57BL/6 쥐 외상성 뇌손상 모델에서 뇌 손상 정도에 따른 조직병리학적 변화 및 신경행동학적 특징)

  • Oh, Ki Young;Choi, Dong Won;Jang, Moon Soon;Lee, Ji Han;Kim, Sang Chul;Park, Jung Soo;Lee, Suk Woo;Kim, Hoon
    • Journal of The Korean Society of Emergency Medicine
    • /
    • v.28 no.5
    • /
    • pp.457-466
    • /
    • 2017
  • Purpose: Traumatic brain injury (TBI) is a significant cause of morbidity and mortality worldwide. Severity of the initial insult is one of the most significant factors affecting outcome following TBI. In order to investigate the mechanisms of cellular injury and develop novel therapeutic strategies for TBI, we designed a standardized animal TBI model and evaluated histological and functional outcomes according to the degree of impact severity. Methods: Male adult C57Bl/6 mice underwent controlled cortical impact (CCI) at varying depths of deflection (1.0-2.0 mm). We performed hematoxylin and eosin staining at 7 days after recovery from TBI. Neurobehavioral characterization after TBI was analyzed by the Barnes maze test, passive avoidance test, open field test, rotarod test, tail suspension test, and light/dark test. Results: We observed a graded injury response according to the degree of deflection depths tested (diameter, 3 mm; velocity, 3 m/s; and duration, 500 ms) compared to sham controls. In the Barnes maze test, the severe TBI (2 mm depth) group showed reduced spatial memory as compared with the sham and mild TBI (1 mm depth) groups at 7 days after TBI. There was a significant difference in the results of the open field test and light/dark test among the three groups. Conclusion: Our findings demonstrate that the graded injury responses following TBI resulted in differential histopathological and behavioral outcomes in a mouse experimental CCI model. Thus, a model of CCI with histologic/behavioral outcome analysis may offer a reliable and convenient design for preclinical TBI research involving mice.

Uncoupled Solution Approach for treating Fluid-Structure Interaction due to the Near-field Underwater Explosion (근거리 수중폭발에 따른 유체-구조 상호작용 취급을 위한 비연성 해석방법)

  • Park, Jin-Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.10
    • /
    • pp.125-132
    • /
    • 2019
  • Because the water exposed to shock waves caused by an underwater explosion cannot withstand the appreciable tension induced by the change in both pressure and velocity, the surrounding water is cavitated. This cavitating water changes the transferring circumstance of the shock loading. Three phenomena contribute to hull-plate damage; initial shock loading and its interaction with the hull plate, local cavitation, and local cavitation closure then shock reloading. Because the main concern of this paper is local cavitation due to a near-field underwater explosion, the water surface and the waves reflected from the sea bottom were not considered. A set of governing equations for the structure and the fluid were derived. A simple one-dimensional infinite plate problem was considered to verify this uncoupled solution approach compared with the analytic solution, which is well known in this area of interest. The uncoupled solution approach herein would be useful for obtaining a relatively high level of accuracy despite its simplicity and high computational efficiency compared to the conventional coupled method. This paper will help improve the understanding of fluid-structure interaction phenomena and provide a schematic explanation of the practical problem.

A simple approach to refraction statics with the Generalized Reciprocal Method and the Refraction Convolution Section (GRM과 RCS 방법을 이용한 굴절파 정적 시간차를 구하는 간단한 방법)

  • Palmer Derecke;Jones Leonie
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.1
    • /
    • pp.18-25
    • /
    • 2005
  • We derive refraction statics for seismic data recorded in a hard rock terrain, in which there are large and rapid variations in the depth of weathering. The statics corrections range from less than 10 ms to more than 70 ms, often over distances as short as 12 receiver intervals. This study is another demonstration of the importance in obtaining accurate initial refraction models of the weathering in hard rock terrains in which automatic residual statics may fail. We show that the statics values computed with a simple model of the weathering using the Generalized Reciprocal Method (GRM) and the Refraction Convolution Section (RCS) are comparable in accuracy to those computed with a more complex model of the weathering, using least-mean-squares inversion with the conjugate gradient algorithm (Taner et al., 1998). The differences in statics values between the GRM model and that of Taner et al. (1998) systematically vary from an average of 2ms to 4ms over a distance of 8.8 km. The differences between these two refraction models and the final statics model, which includes the automatic residual values, are generally less than 5 ms. The residuals for the GRM model are frequently less than those for the model of Taner et al. (1998). The RCS statics are picked approximately 10 ms later, but their relative accuracy is comparable to that of the GRM statics. The residual statics values show a general correlation with the refraction statics values, and they can be reduced in magnitude by using a lower average seismic velocity in the weathering. These results suggest that inaccurate average seismic velocities in the weathered layer may often be a source of short-wavelength statics, rather than any shortcomings with the inversion algorithms in determining averaged delay times from the traveltimes.

Numerical Analysis on the Turbulence Patterns in The Scour Hole at The Downstream of Bed Protection (하상보호공 직하류부 세굴공의 난류양상에 관한 수치해석적 연구)

  • Lee, Jaelyong;Park, Sung Won;Yeom, Seongil;Ahn, Jungkyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.5
    • /
    • pp.20-26
    • /
    • 2019
  • Where hydraulic structures are to be installed over the entire width of a river or stream, usually a bed protection structure is to be installed. However, a local scour occurs in which the river bed downstream of the river protection system is eroded due to the influence of the upstream flow characteristics. This local scour is dominant in the flow and turbulence characteristics at the boundary of the flow direction and in the material of the bed materials, and may gradually become dangerous over time. Therefore, in this study, we compared the turbulence patterns in the local scour hole at the downstream of the river bed protection with the results of the analysis of the mobile bed experiment, and compared with the application of OpenFoam, a three dimensional numerical analysis model. The distribution of depth-averaged relative turbulence intensities along the flow direction was analyzed. In addition to this result, the stabilization of scour hole was compared with the bed shear stress and Shields parameter, and the results were compared by changing the initial turbulent flow conditions. From the results, it was confirmed that the maximum depth of generation of the three-stage was dominantly developed by the magnitude of depth-averaged relative turbulence intensity rather than the mean flow velocity. This result also suggests that design, construction or gate control are needed to control the depth-averaged relative turbulence intensities in order to reduce or prevent the local scour faults that may occur in the downstream part of the bed protection.

CFD Simulations of the Trees' Effects on the Reduction of Fine Particles (PM2.5): Targeted at the Gammandong Area in Busan (수목의 초미세먼지(PM2.5) 저감 효과에 대한 CFD 수치 모의: 부산 감만동 지역을 대상으로)

  • Han, Sangcheol;Park, Soo-Jin;Choi, Wonsik;Kim, Jae-Jin
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.5_3
    • /
    • pp.851-861
    • /
    • 2022
  • In this study, we analyzed the effects of trees planted in urban areas on PM2.5 reduction using a computational fluid dynamics (CFD) model. For realistic numerical simulations, the meteorological components(e.g., wind velocity components and air temperatures) predicted by the local data assimilation and prediction system (LDAPS), an operational model of the Korea Meteorological Administration, were used as the initial and boundary conditions of the CFD model. The CFD model was validated against, the PM2.5 concentrations measured by the sensor networks. To investigate the effects of trees on the PM2.5 reduction, we conducted the numerical simulations for three configurations of the buildings and trees: i) no tree (NT), ii) trees with only drag effect (TD), and iii) trees with the drag and dry-deposition effects (DD). The results showed that the trees in the target area significantly reduced the PM2.5 concentrations via the dry-deposition process. The PM2.5 concentration averaged over the domain in DD was reduced by 5.7 ㎍ m-3 compared to that in TD.

Effects of Dynamic Tubing Gait Training on Postural Alignment, Gait, and Quality of Life in Chronic Patients with Parkinson's Disease : Case Study (동적탄력튜빙 보행훈련 프로그램이 만성 파킨슨병 환자의 자세정렬과 보행능력과 삶의 질에 미치는 영향 : 사례연구)

  • Lee, Dong-Ryul
    • Journal of Korea Entertainment Industry Association
    • /
    • v.15 no.8
    • /
    • pp.363-377
    • /
    • 2021
  • The present study investigated the effects of dynamic tubing gait training(I and II) on the postural alignment, gait, and quality of life in chronic patients with Parkinson's disease. This study is based on the case study that recruited a total of 3 patients with chronic Parkinson's disease (Hoehn and Yahr Stage of 1 to 3 each one person). Dynamic tubing gait training (I and II) applied to chronic patients with Parkinson's disease for 25 sessions, 30 minutes a day, 5 days a week, over 5 weeks period. To investigate the effects of this study, evaluating using the postural alignment test, muscle activity tests, gait analysis, and quality of life scale for patient with Parkinson's disease. After the intervention of Dynamic tubing gait training (I and II), Trunk flexion was decreased. Also, during walking from initial contact (IC) to mid stance (Mst), muscle activity of Quadriceps, Hamstring, and Tibialis Anterior (TA) was increased and muscle activity of Gastrocnemius was decreased. The muscle activation of Erector Spinae (ES T12, L3) was increased in the H&Y I and III stages and decreased in the H&Y II stage. Length of gait line, single support line, ant/post position and lateral symmetry of center of pressure (COP) parameters improved. The spatio-temporal gait parameters including of step length, stride length, and velocity was increased, and cadence decreased. Further the quality of life of patients with Parkinson's disease was improved. Based on these findings, Dynamic tubing gait training (I and II) could be applied as a new approach to improve posture, gait, quality of life in chronic patients with Parkinson's disease for more than 5 years, whose drug resistance is halved.

Progressive Evaluation of Concrete Deterioration Caused by Chloride-Induced Steel Corrosion Using Impact-Echo Testing (충격 반향 신호 모니터링을 통한 철근 부식 진전에 따른 콘크리트 상태 평가)

  • Rizky Pitajeng;Julfikhsan Ahmad Mukhti;Seong-Hoon Kee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.28 no.3
    • /
    • pp.37-46
    • /
    • 2024
  • This study investigates the evolution of concrete damage due to chloride-induced steel corrosion through Impact-echo (IE) testing. Three reinforced concrete specimens, each measuring 1500 mm in length, 400 mm in width, and 200 mm in thickness, were fabricated using three concrete mixture proportions of blended cement types: ordinary Portland cement, ground granulated blast-furnace slag and fly ash. Steel corrosion in the concrete was accelerated by impressing a 0.5 A current following a 35-day cycle of wet-and-dry saturation in a 3% NaCl solution. Initial IE data collected during the saturation phase showed no significant changes, indicating that moisture had a minimal impact on IE signals and highlighting the slow progress of corrosion under natural conditions. Post-application of current, however, there was a noticeable decline in both IE peak frequency and the P-wave velocity in the concrete as the duration of the impressed current increased. Remarkably, progressive monitoring of IE proves highly effective in capturing the critical features of steel-corrosion induced concrete deterioration, such as the onset of internal damages and the rate of damage propagation. These results demonstrate the potential of progressive IE data monitoring to enhance the reliability of diagnosing and prognosticating the evolution of concrete damage in marine environment.

The Reliability and Convergent Validity of the 180 ° Turn Test in Stroke Patients and the Effects of Turn Direction on Time and Step Count (뇌졸중 환자의 180 ° 회전 검사의 신뢰도와 수렴 타당도 및 회전 방향이 소요시간과 걸음 수에 미치는 효과 )

  • Sung-Heon An;Byoung-Kwon Lee
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.12 no.3
    • /
    • pp.189-199
    • /
    • 2024
  • Purpose : This study aimed to investigate the test-retest reliability, minimal detectable change (MDC), and the effect of turning direction on the time and number of steps taken during the 180 ° turn test in subacute stroke patients. Additionally, it examined the concurrent validity of the 180 ° turn test. Methods : The study included 28 subacute stroke patients. The test-retest reliability of the 180 ° turn test according to the direction of rotation (paretic and non-paretic sides) by comparing the consistency between the initial assessment and a reassessment conducted 7 days later. Concurrent validity was examined by assessing the correlation of the 180 ° turn test with the Fugl-Meyer assessment of lower extremity (FMA-L/E), Berg balance scale (BBS), 10-meter walk test (10 mWT), and timed up and go test (TUG). Results : The ICC for the time taken to turn 180 ° to the affected and unaffected sides were 0.971 and 0.918, respectively, indicating excellent reliability. The ICC for the number of steps were 0.944 and 0.932, respectively. The MDC for the time taken were 0.33 seconds (affected side) and 0.67 seconds (unaffected side). The MDC for the number of steps were 0.49 (affected side) and 0.63 (unaffected side). The paired t-test showed the limited community ambulator group took significantly longer to turn to the unaffected side (p<.048). Significant correlations were found between the 180 ° turn test and FMA-L/E (r= -0.395 to -0.416), BBS (r= -0.622 to -0.684), 10 mWT (r= 0.720 to 0.730), and TUG (r= 0.684 to 0.790) (p<.05 to .01). Conclusion : The 180 ° turn test demonstrated excellent test-retest reliability and high validity when correlated with other functional measures in subacute stroke patients. MDC values indicated high reliability. Faster walking speeds (≥0.95 m/s) were unaffected by turning direction, while slower speeds (<0.58 m/s) showed significant effects. The 180 ° turn test is a simple, sensitive, and reliable tool for evaluating turning ability in subacute stroke patients.

Extent of Subprosthetic Pannus after Aortic Valve Replacement: Changes Over Time and Relationship with Echocardiographic Findings (대동맥판막치환술 후 발생한 판막하 판누스(Pannus): 시간에 따른 변화 및 심초음파 소견)

  • Mi Yeon Park;Hyun Jung Koo;Hojin Ha;Joon-Won Kang;Dong Hyun Yang
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.5
    • /
    • pp.1151-1163
    • /
    • 2020
  • Purpose This study aimed to evaluate changes of subprosthetic pannus on cardiac CT and determine its relationship to echocardiographic findings in patients with mechanical aortic valve replacement (AVR). Materials and Methods Between April 2011 and November 2017, 17 AVR patients (56.8 ± 8.9 years, 12% male) who showed pannus formation on CT and had undergone both follow-up CT and echocardiography were included. The mean interval from AVR to the date of pannus detection was 10.5 ± 7.1 years. In the initial and follow-up CT and echocardiography, the pannus extent and echocardiographic parameters were compared using paired t-tests. The relationship between the opening angle of the prosthetic valve and the pannus extent was evaluated using Pearson correlation analysis. Results The pannus extent was significantly increased on CT (p < 0.05). The peak velocity (3.9 ± 0.8 m/s vs. 4.2 ± 0.8 m/s, p = 0.03) and mean pressure gradient (36.4 ± 15.5 mm Hg vs. 42.1 ± 15.8 mm Hg, p = 0.03) were significantly increased. The mean opening angles of the mechanical aortic leaflets were slightly decreased, but there was no statistical significance (73.1 ± 8.3° vs. 69.4 ± 12.1°, p = 0.12). The opening angle of the prosthetic leaflets was inversely correlated with the pannus extent (r = -0.57, p < 0.001). Conclusion The pannus extent increases over time, increasing transvalvular peak velocity and the pressure gradient. CT can be used to evaluate the pannus extent associated with hemodynamic changes that need to be managed by surgical intervention.

Respiratory air flow transducer calibration technique for forced vital capacity test (노력성 폐활량검사시 호흡기류센서의 보정기법)

  • Cha, Eun-Jong;Lee, In-Kwang;Jang, Jong-Chan;Kim, Seong-Sik;Lee, Su-Ok;Jung, Jae-Kwan;Park, Kyung-Soon;Kim, Kyung-Ah
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.5
    • /
    • pp.1082-1090
    • /
    • 2009
  • Peak expiratory flow rate(PEF) is a very important diagnostic parameter obtained from the forced vital capacity(FVC) test. The expiratory flow rate increases during the short initial time period and may cause measurement error in PEF particularly due to non-ideal dynamic characteristic of the transducer. The present study evaluated the initial rise slope($S_r$) on the flow rate signal to compensate the transducer output data. The 26 standard signals recommended by the American Thoracic Society(ATS) were generated and flown through the velocity-type respiratory air flow transducer with simultaneously acquiring the transducer output signal. Most PEF and the corresponding output($N_{PEF}$) were well fitted into a quadratic equation with a high enough correlation coefficient of 0.9997. But only two(ATS#2 and 26) signals resulted significant deviation of $N_{PEF}$ with relative errors>10%. The relationship between the relative error in $N_{PEF}$ and $S_r$ was found to be linear, based on which $N_{PEF}$ data were compensated. As a result, the 99% confidence interval of PEF error was turned out to be approximately 2.5%, which was less than a quarter of the upper limit of 10% recommended by ATS. Therefore, the present compensation technique was proved to be very accurate, complying the international standards of ATS, which would be useful to calibrate respiratory air flow transducers.