• Title/Summary/Keyword: Initial Fire Source

Search Result 17, Processing Time 0.022 seconds

An Relational Analysis between Humidity, Temperature and Fire Occurrence using Public Data (공공데이터를 이용한 습도 및 온도와 실화 발생 간의 관계분석)

  • Song, Dong-Woo;Kim, Ki-Sung;Lee, Su-Kyung
    • Fire Science and Engineering
    • /
    • v.28 no.2
    • /
    • pp.82-90
    • /
    • 2014
  • According to recent government's 3.0 operating paradigm for the opening and sharing of public information, relationship between humidity, temperature and fire occurrence were analyzed using the data in National Weather Service and National Emergency Management Agency. In order to analyze the relationships between humidity, temperature and fire occurrence, hourly frequency of fire occurrence compared with humidity and temperature ranges was suggested as an analysis method. Tendencies of fire occurrence frequencies were examined through this and characteristics of detailed attributes could be statistically identified. Results about hourly frequencies of fire occurrence by classifying the humidity ranges in each region showed increasing frequencies in all areas where the humidity is lower. Hourly frequencies of fire occurrence according to temperature ranges were identified to be similar in each area as well. In addition, characteristics of objects' attributes were analyzed including types of fire, igniting source of fire, initial complex, reasons of fire occurrence, and distinctive directions were suggested. Suggested method in this paper could be practically used when suggesting the frequency in each category in fire occurrence statistics of National Fire Information System.

Characteristics of Thermal and Fluid Flows for Different Fire Locations in Underground Combined Cycle Power Plant (화원 위치에 따른 지하 복합 발전 플랜트 내 열유동 특성 연구)

  • Sung, Kun Hyuk;Bang, Joo Won;Lee, Soyeong;Ryou, Hong Sun;Lee, Seong Hyuk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.5
    • /
    • pp.716-722
    • /
    • 2017
  • The present study numerically investigates the effect of obstacles located in the trajectory of fire plume flow on heat flow characteristics by using Fire Dynamics Simulation (FDS) software in an underground combined cycle power plant (CCPP). Fire size is taken as 10 MW and two different locations of fire source are selected depending on the presence of an obstacle. As the results, when the obstacle is in the trajectory of fire plume, hot plume arrives at the ceiling about 5 times slower in the upper of the fire in comparison to the results without obstacle. In addition, the average propagation time of ceiling jet increases by about 70 % with the distance from the ceiling in the upper of the fire, and it increases mainly about 4 times at the distance of 10 m. Consequently, it is noted that the analysis of heat flow characteristics in the underground CCPP considering fire scenarios is essential to develop the fire detection system for initial response on evacuation and disaster management.

Analysis Method for Damage Patterns of Low Voltage Switches for PL Judgment (PL 판정을 위한 저압용 스위치의 소손 패턴 해석기법)

  • Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.24 no.5
    • /
    • pp.136-141
    • /
    • 2010
  • The purpose of this study is to examine the structure and heat generation mechanism of low voltage switches used to turn on or off the power supply to an indoor lighting system and investigate how the fixtures and movable contacts of the switches are damaged depending on the types of energy sources in order to secure the judgment base for expected PL disputes. Based on the Korean Standard (KS) testing method for incombustibility, this study applied a general flame to the switch. In addition, current was supplied to the switch using the PCITS (Primary Current Injection Test System). The ambient temperature and humidity were maintained at $22{\pm}2^{\circ}C$ and 40~60% respectively while performing the test. It is thought that the switch generated heat due to a defective connection of the wire and clip, insulation deterioration and defective contact of the movable contact, etc. The surface of the switch damaged by the general flame was uniformly carbonized. When the flame source was removed, the fire on the switch was extinguished naturally. From the result obtained by disassembling the switch carbonized by the general flame, it could be seen that fixtures and movable contacts remained in comparatively good shape but the enclosure, clip support, movable contact, indicating lamp, etc. showed carbonization and discoloration. In the case of the switch damaged by overcurrent, the clip connecting the wires, clip support, etc. showed almost no trace of damage, but the fixtures, movable contact, indicating lamp, etc. were severely carbonized. That is, the sections with high contact resistance were intensively damaged and showed a damage pattern indicating that carbonization progressed from the inside to the outside. Therefore, it is possible to judge the initial energy source by analyzing the characteristics of the carbonization pattern and the metal fixtures of damaged switches.

A Numerical Study on Smoke Behavior of Fishing Vessel Engine Room (어선 기관실의 연기 거동에 관한 수치해석 연구)

  • JANG, Ho-Sung;JI, Sang-Won
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.5
    • /
    • pp.683-690
    • /
    • 2021
  • The ventilation system of the engine room of a ship is generally installed to supply the combustion air necessary for the internal combustion engine and to remove the heat source generated in the engine room, and it must satisfy the international standard (ISO 8861) for the design conditions and calculation standards for the ventilation of the ship engine room. The response delay of the ventilation system including the fire detector is affected by the airflow formed inside the area and the location of the fire detector. In this study, to improve the initial fire detection response speed of a fire detector installed on a fishing vessel and to maintain the sensitivity of the installed detector, the smoke behavior was simulated using the air flow field inside the engine room, the amount of combustion air in the internal combustion engine, and the internal pressure of the engine room as variables. Analysis of the simulation results showed that reducing the flow rate in the air flow field and increasing the vortex by reducing the internal pressure of the engine room and installing a smoke curtain would accelerate the rise of the ceiling of the smoke component and improve the smoke detector response speed and ventilation system.

Evaluation of Smoke Control Performance of Ventilation System Using by Hot Smoke Test (Hot Smoke Test를 이용한 주차장 환기설비의 제연 성능평가)

  • Joung, Suckhwan
    • Journal of Korean Society of Disaster and Security
    • /
    • v.12 no.2
    • /
    • pp.47-56
    • /
    • 2019
  • Recently, in order to overcome the difficulty of entering a fire source due to the occurrence of a large amount of smoke in the event of a fire in a parking lot, it has used that a method of discharge smoke using air supply, exhaust fans and jet fans installed for ventilation of parking lots. In this study, the variation of flow in the smoke layer was observed using CCTV under two conditions, in which only the air supply fan operates and the manned fan operates together, and the temperature around the plume was compared to Albert eq. to assess its suitability as a parking lot ventilation performance evaluation method. As a result, it was found that the smoke layer could be disturbed if the Jet Fan was operated at the same time, which could lead to the possibility of an initial evacuation disturbance. However, the additional operation of the Jet Fan has been confirmed by the observation CCTV that the emission performance is improved, which is believed to help conduct the suppression operation. The temperature around the plume was measured and compared to Alpert eq, and was analyzed to be about $2^{\circ}C$ lower at the center axis of the plume and $9.0^{\circ}C$ higher at 8 m in the direction of the discharge of smoke. The results of temperature measurements around the plume were lower than the maximum temperature expected in AS 4391 and did not exceed the expected temperature risk caused by the experiment. As with these results, the temperature risk from the progression of hot smoke tests is foreseeable, so it will be available as one of the general evaluation methods for assessing smoke control performance in a parking lot without relevant criteria.

Seed Quality, Germinability and Initial Growth of Pterocarpus erinaceus (African Rosewood). How Important are Mother Tree Size, Source and Timing of Fruit Harvest?

  • Tiika, Richard J.;Issifu, Hamza;Baatuuwie, Bernard Nuoleyeng;Nasare, Latif Iddrisu;Husseini, Rikiatu
    • Journal of Forest and Environmental Science
    • /
    • v.35 no.2
    • /
    • pp.69-77
    • /
    • 2019
  • Pterocarpus erinaceus is a multipurpose tree species indigenous to semi-arid and Guinean-savanna woodlands of Africa. Natural regeneration on the savanna is being hampered by higher fire frequencies and other land use changes. Simultaneously, demand for timber from the species on the international market is on the rise, raising conservation concerns. To ensure sustainability, good quality seeds, sources of which have not received much research focus, are needed for afforestation. This study investigated how seed quality, germinability and initial seedling growth of P. erinaceus might be influenced by land-use type, mother tree size as well as source and timing of fruit harvest, using both correlational and experimental approaches. The results showed that up to 94.6% of all harvested fruits contained seeds, with no differences found between fruits harvested from cultivated and non-cultivated lands. Percentage of (sound) unblemished seeds was found to be higher for fruits harvested early March (47.3%) than fruits from late April (39.5%). Percentage sound seeds was 41.4% for dispersed fruits (i.e. detached fruits picked from under mother trees) which was not found to differ from undispersed fruits (i.e. fruits harvested while still attached to mother trees) at 45.5%. Also, the influence of fruit harvest time was not found to be different for dispersed and undispersed fruits. Correlations between seed set (proportion of fruits containing seeds) and mother tree size (both tree height and DBH) were found to be very low and non-significant for both dispersed and undispersed fruits. Across mother trees, mean emergence percent was 79.7%, and mean seedling height at three weeks following emergence was 5.32 cm. Both emergence percentage and seedling height were not found to differ among mother trees, but seeds from dispersed fruits had a higher emergence percent (85%) than seeds from undispersed fruits (74%). Implications of findings are discussed.

Thermal Stability and Critical Ignition Temperature of RPF (RPF의 열적 안정성과 한계발화온도)

  • Lim, Woo-Sub;Choi, Jae-Wook
    • Fire Science and Engineering
    • /
    • v.22 no.1
    • /
    • pp.99-104
    • /
    • 2008
  • It is important to understand thermal characteristic as a method to estimate the new materials, because spontaneous ignition characterized by causing combustion in the low temperature without ignition source. If can not find out the thermal characteristics of materials, it is frequent that causes of fires could not be found. The danger level of spontaneous ignition material should be estimated and by closely studying its thermal characteristic. However, RPF(Refuse Paper & Plastic Fuel) is a solid matter and getting increasesa year by year because it is an economy profit as alternative energy for limited fossil fuels. Some time RPF occur a fire in the cases of its production process and conservation. Therefore study for thermal stability and critical ignition temperature of RPF was so imperative that the experiment by means of Bombe Calorimeter, TG-DTA, MS80, SIT-II, and Wire Basket Test was implemented. As a result, RPF had a caloric value 26.4-28.3 MJ/kg, and its initial pyrolysis temperature was $192^{\circ}C$ at heating rate 2 K/min. With the result of analysis by MS 80 which is an instrument measuring microscopic calory, pure RPF not containing water has higher caloric value than RPF containing 20% water. Also, SIT-II which is an instrument of insulated auto-ignition was ignited by $118.5^{\circ}C$. This temperature is lower than that of Wire Basket Test. The critical ignition temperature was calculated by Frank-Kamenetskii equation can cause ignition at $80^{\circ}C$ when conserved in the height of 10 m by the standard of infinity slab.