• Title/Summary/Keyword: Infrared thermometer

Search Result 70, Processing Time 0.023 seconds

Characteristics of Insulation Degradation in Epoxy Mold Type BCT (에폭시 몰드형 BCT의 절연열화 특성)

  • Song, Jae-Joo;Lee, Jung-Choi;Lim, Sung-Hun;Ko, Seok-Cheol;Han, Byung-Sung
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.10
    • /
    • pp.902-908
    • /
    • 2005
  • Various stresses (such as electrical stress, mechanical stress, environmental and electrochemical stress, and defects of structure) result in insulation degradation of epoxy mold type insulators. Since the insulation degradation of BCT(Bushing Current Transformer) and bushing proceeds during fabrication process or operation time due to these causes, various methods to reduce the degradation in their insulation ability have been suggested. In this paper, we investigated surface temperature increment of these insulators due to PD(partial discharge). After the voltage applied into the insulator to generate the artificial PD, the surface temperature of the insulator was measured with non-contact thermometer using infrared rays. It was confirmed through the analysis based on PD experiments that the procession in the insulation degradation of the insulator could be estimated through the measurement of the surface temperature in the insulator.

A study on dynamic behavior of bidirectional SMA Actuator with forced-cooling (강제공냉 차동식 형상기억합금 액츄에이터의 동작특성에 관한 연구)

  • 정상화;김현욱;차경래
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.10a
    • /
    • pp.47-52
    • /
    • 2003
  • In the recent years, as the research and the development of micro and precision machinery become active, the interest of micro actuators using SMA(Shape Memory Alloy) has been increased. The dynamic characteristic analysis of SMA is necessary for actuator application and many common researches report the material characteristics of SMA sufficiently. However, the research on dynamic characteristics is very deficient. In this paper, the helical spring are fabricated with NiTi SMA wire of high resistivity. The force, response speed, temperature, and displacement are measured by digital force gauge, infrared thermometer, and laser displacement sensor so that the dynamic characteristics of this SMA is analyzed. Also, bidirectional actuator was fabricated and experimented fir its performance.

  • PDF

A study on the Dynamic Characteristics of Bidirectional Acutator using Shape Memory Alloy (형상기억합금을 이용한 차동식 액츄에이터의 동특성연구)

  • 정상화;김현욱;장우양;김경석;차경래;나윤철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.755-758
    • /
    • 1997
  • In the recent years, as the research and the development of micro and precision machinery become active, the interest of micro actuators using SMA(Shape Memory Alloy) has been increased. The dynamic characteristic analysis of SMA is necessary for actuator application and many common researches report the material characteristics of SMA sufficiently. However, the research of dynamic characteristics is very deficient. In this paper, the helical spring is fabricated with NiTi SMA wire of high resistivity The force, response speed, temperature, and displacement are measured by digital force gauge, infrared thermometer, and laser displacement sensor so that the dynamic characteristics of this SMA actuator is analyzed.

  • PDF

A study on the Improvement of the Performance of Biodirectional SM Actuator (NiTi 형상기억합금을 이용한 차동식 액츄에이터의 동작성능 향상을 위한 연구)

  • Jeong, Sang-Hwa;Kim, Hyon-Uk;Cha, Kyoung-Rae;Song, Suk;Shin, Byung-Su;Lee, Kyoung-Hyoung
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.346-351
    • /
    • 2003
  • In the recent years, as the research and the development of micro and precision machinery become active, the interest of micro actuators using SMA(Shape Memory Alloy) has been increased. The dynamic characteristic analysis of SMA is necessary for actuator application and many common researches report the material characteristics of SMA sufficiently. However, the research on dynamic characteristics is very deficient. In this paper, the helical spring are fabricated with NiTi SMA wire of high resistivity. The force, response speed, temperature, and displacement are measured by digital force gauge, infrared thermometer, and laser displacement sensor so that the dynamic characteristics of this SMT is analyzed. Also, bidirectional actuator was fabricated and experimented for its performance

  • PDF

The Practical Method and Experimental Verification of Temperature Estimation in the Permanent Magnet of Electric Machine

  • Kang, Kyongho;Yu, Sukjin;Lee, Geunho;Lee, Byeong-Hwa
    • Journal of Magnetics
    • /
    • v.20 no.4
    • /
    • pp.421-426
    • /
    • 2015
  • This paper presents a practical method for estimation of average temperature in the permanent magnet (PM) of electric machine by using finite element analysis (FEA) and dynamo load experiment. First of all, the temperature effect of PM to the torque has been employed by FEA in order to evaluate the Temperature-Torque characteristic curve. The 1st order polynomial equation which is torque attenuation coefficient is derived by the FEA result of the Temperature-Torque curve. Next, torque saturation test with constant current condition is performed by dynamo load experiment. Then, the temperature trend can be estimated by adding the initial starting temperature using the torque attenuation coefficient and torque saturation curve. Lastly, estimated temperature is validated by infrared thermometer which measures temperature of PM surface. The comparison between the estimated result and experimental result gives a good agreement within a deviation of maximum $8^{\circ}C$.

Comparison of Junction Temperature for Top-Emitting Organic Light-Emitting Diodes Fabricated on Different Substrates

  • Juang, Fuh-Shyang;Tsai, Yu-Sheng;Wang, Shun-Hsi;Chen, Chuan-Hung;Cheng, Chien-Lung;Liao, Teh-Chao;Chen, Guan-Wen
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1148-1151
    • /
    • 2009
  • A self-designed, written in labview, Organic Light-Emitting Diode junction temperature measuring program was used to calculate the internal junction temperature for devices during operation, and an infrared thermometer was used to measure the backside temperature of the device substrate, to discuss the effects of the junction and substrate temperature difference to the characteristics of the device.

  • PDF

Effect of Aceclofenac on the Skeletal Muscle (Aceclofenac이 골격근 형태에 미치는 효과)

  • Song, Myung-Soo;Kim, Tea-Yeal;Yoon, Hee-Jong;Jang, Ki-Yen
    • Journal of Korean Physical Therapy Science
    • /
    • v.7 no.2
    • /
    • pp.597-605
    • /
    • 2000
  • There has been several usual ways to cure pain in osteological muscle: use oral medicine or injection, or apply medicine to a sore place. The purpose of this study was to examine, by using thermometer and digital infrared thermographic imaging, how much the permeation of aceclofenac, an anodyne and antiphlogistic, into sore skin brought a change to skin temperature after that was' applied to it. The findings of this study were as below; 1. A cream made of aceclofenac yielded $0.61^{\circ}C$ difference in temperature, but the difference wasn't statistically significant. 2. An aceclofenac to which oleic acid was added went through microemulsion and applied, and there was $0.3^{\circ}C$ change in temperature, the biggest significant difference(P<.05), after approximately 15 minutes passed. 3. An aceclofenac to which labrasol was added went through microemulsion and applied, and there was a growing rise in temperature with the lapse of time. After 30 minutes passed, the final temperature showed $1.25^{\circ}C$ rise, which was a significant change(P<.05). 4. As the temperature was measured by digital infrared thermographic imaging, there was about $3.97^{\circ}C$ fall, the biggest change, which was significant(P<.05). The findings of this study suggested that the application of aceclofenac to sore skin caused a change in skin temperature, as that permeated into it.

  • PDF

Experimental Study of the Oven Dried Soil Weight Measurement Using Singularity Analysis (특이점 분석에 의한 노건조된 흙의 건조무게 측정에 관한 실험적 연구)

  • Sukjoo Kim
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.3
    • /
    • pp.5-14
    • /
    • 2023
  • The dry unit weight of the soil can be obtained by measuring the weight of the oven dried soil. According to the Korean Industrial Standards (KS F), oven dried soil at 110±5℃ continuously increases in weight when exposed to air. However, there is no regulation on the weight measurement time of oven dried soil, making it difficult to accurately measure the dry weight. In this study, a method to easily determine the dry weight was presented through the analysis of the weight singularity that appears during weight measurement. The weight singularity represents the smallest value among the measured weights, and is the weight at which the effect of moisture absorption in the air of the sample is minimized. In the course of the experiment, a container was selected using a statistical analysis method, and a photograph of the soil samples were presented using an optical microscope. In addition, the temperature of the weight singularity was measured using a non-contact infrared thermometer. As a result of analyzing the weight singularity of six types of soil, including Jumunjin sand, Naeseong stream sand, Yecheon weathered granite soil, Jeju sand, Sabkha sand, and Ulleung sand, the weight singularity of oven dried sample appeared between 8 and 27 seconds after weight measurement, and the temperature ranged from 103.4 to 108.13℃. The weight decrease rate of the singularity was 0.0066 to 0.0085% depending on the soil samples.

Development of Airborne Remote Sensing System for Monitoring Marine Meteorology (Sea Surface Wind and Temperature) (연안 해양기상(해상풍, 수온) 관측을 위한 항공기 원격탐사 시스템)

  • Kim, Duk-Jin;Cho, Yang-Ki;Kang, Ki-Mook;Kim, Jin-Woo;Kim, Seung-Hee
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.18 no.1
    • /
    • pp.32-39
    • /
    • 2013
  • Although space-borne satellites are useful in obtaining information all around the world, they cannot observe at a suitable time and place. In order to overcome these limitations, an airborne remote sensing system was developed in this study. It is composed of a SAR sensor and a thermal infrared sensor. Additionally GPS, IMU, and thermometer/hygrometer were attached to the plane for radiometric and geometric calibration. The brightness of SAR image varies depending on surface roughness, and capillary waves on the sea surface, which are easily generated by sea winds, induce the surface roughness. Thus, sea surface wind can be estimated using the relationship between quantified SAR backscattering coefficient and the sea surface wind. On the other hand, thermal infrared sensor is sensitive to measure object's temperature. Sea surface temperature is obtained from the thermal infrared sensor after correcting the atmospheric effects which are located between sea surface and the sensor. Using these two remote sensing sensors mounted on airplane, four test flights were carried out along the west coast of Korea. The obtained SAR and thermal infrared images have shown that these images were useful enough to monitor coastal environment and estimate marine meteorology data.

Experimental Interpretation of Heat Transmits Pattern on Warm Needling (온침의 열전달 특성에 대한 실험적 해석)

  • Yang, Seung-Bum;Park, Soon-Jae;Lee, Jae-Gun;Jung, Ji-Chul;Kim, Jae-Hyo
    • Korean Journal of Acupuncture
    • /
    • v.34 no.3
    • /
    • pp.109-115
    • /
    • 2017
  • Objectives : Many researches have studied warm needling technique to standardize its treatment by temperature measurement and material differences in the effectiveness. The purpose of this study is to compare the temperature changes of the acupuncture needle shaft during the combustion process of the moxa stick to determine the heat transfer pattern of the warn needling. Methods : A moxa stick($7{\times}8mm$) was connected to one side of the needle shaft using a stainless steel needle(ø 0.3 mm, ø 0.5 mm, ø 0.8 mm, shaft length 40 mm) with the needle handle removed. During the warm needling, temperature changes of the needle shaft were observed with an infrared camera(Flir E30) and an infrared thermometer(TESTO 845). Results : In the normal condition, heat transmit of needle shaft increased at spots 10 mm and 25 mm below the moxa stick. The amount of heat transmit increased with the diameter of needle shaft. However, when the heat shield was installed to exclude radiant heat from the moxa stick, heat transfer was less at 10 mm below the moxa stick and no temperature change was observed at 25 mm below the moxa stick. Heat transfer by warm needling does not reach the end of needle shaft even in ø 0.8 mm needle. Conclusions : It is suggested that the radiant heat of moxa stick results in the heat transmit of acupuncture needle shaft. Thus, radiant heat transmit must be considered as one of the heat transfer characteristics of the warm needling.