• Title/Summary/Keyword: Infrared thermal imaging system

Search Result 109, Processing Time 0.031 seconds

The Effect of Electrical Stimulation on the Changes of Skin Temperature in Normal and Low Back Pain Patients (전기자극이 정상인과 요통환자의 체표면 온도 변화에 미치는 영향)

  • Park, Don-Mork;Lim, Jung-Do
    • Journal of Korean Physical Therapy Science
    • /
    • v.5 no.4
    • /
    • pp.817-830
    • /
    • 1998
  • The purpose of this study is to investigate the relationship between effects of TENS (Transcutaneous Electrical Nerve Stimulation) and IFC(Interferrential Current Therapy) to the change of body surface temperature. Cases are 22 normal persons and 22 patients with low back pain. Digital Infrared Thermal Imaging system was used for the detection of body surface temperature. 50Hz in frequency and 25-35mA in intensity were applied to TENS and IFC, 15 and 10 minutes on each. The results were follows ; 1. TENS and IFC has on effect of decreasing surface temperature, which would be from cardiovascular factors. (P<0.001) 2. The influence of IFC to the body surface temperature is greater than TENS, and it seems to be vasoconstriction of sympathetic activity. 3. There were no significant differences of body surface temperature between the two groups before and after electrical stimulation.

  • PDF

A study on the performance characteristics of rotary type Stirling cryocooler (일체형 스터링 냉동기의 설계, 제작 및 성능특성에 관한 연구)

  • Park, S.J.;Hong, Y.J.;Kim, H.B.;Kim, Y.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.1
    • /
    • pp.54-58
    • /
    • 2006
  • Stirling cryocooler is relatively compact, reliable, commercially available. and uses helium as a working fluid. Over the past decade and a half, there has been rapid development of Stirling cryocooler, mainly for military and space applications. Stirling cryocoolers have been widely used lot the cooling of infrared sensors and high temperature superconducting filters to the temperature of the liquid nitrogen. The Stirling cryocooler with the rotary compressor is applicable to the cooling device for the compact mobile thermal imaging system, because the cryocoolers have the compact structure and light weight. In this paper, integral Stirling cryocooler is designed, manufactured and fabricated, and performance characteristics are investigated. This cooler delivers approximately 0.6W cooling at 80K for 20W of input power from 24V DC power supply.

Development and Possibility Evaluation of Thermal Imaging Camera for Medical Monitoring of Body Temperature (열화상카메라 개발을 통한 의료용 체열진단 가능성 평가)

  • Ryu, Seong Mi;Kim, Hye-Jeong
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.20 no.1
    • /
    • pp.57-62
    • /
    • 2015
  • Recently, thermography camera have been using for body-temperature monitoring. We report on fabrication of prototype thermography camera using the chalcogenide-glass lens and the camera test by analysis of thermal image. In this work, it was found out that thermography camera discerned body-temperature between 20 and $50^{\circ}C$ with noise equivalent temperature difference(NETD) of 87.7mK. It is confirmed that thermography camera using the chalcogenide-glass lens is applicable to the body-temperature monitoring system.

Development of MODIS Data Application System

  • Lim, Hyo-Suk;Lee, Seon-Gu;Seo, Doo-Cheon;Lee, Dong-Han;Kim, Mi-Na;Kim, Yong-Seung
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.347-351
    • /
    • 2002
  • The Moderate Resolution Imaging Spectroradiometer (MODIS) on the Earth Observing System (EOS) Terra and Aqua satellites, launched in 1999 and 2002, is directly received by Korea Aerospace Research Institute (KARI) ground station facility. BURI engineers develop a system to receive direct broadcast downlink from MODIS to provide near-realtime, remotely-sensed, spaceborne data to the user community in Korea. MODIS scans a swath width of 2330 km that is sufficiently wide to cover Korean peninsular, Yellow and East Sea at once. The MODIS has 36 spectral bands between 0.415 fm and 14.235 $\mu$m, i.e. through the visible into the thermal infrared. MODIS has been observed active fires, floods, smoke transport, dust storms, severe storms since February of 2000. The KARI is preparing for distribution of direct broadcasted MODIS data to users in Korea. The MODIS database system will be designed and developed by KARI engineer for data service from year of 2003. MODIS data user group will be organized from $\.{O}$ctober to December 2002.

  • PDF

A clinical study on patients with Cold Hypersensitivity on hands and feet and their autonomic nervous system function using of Heart Rate Variability(HRV) (수족냉증 환자의 실태 및 HRV(Heart Rate Variability)를 이용한 자율신경계 기능 평가 연구)

  • Kim, Eun-Sook;Hwang, Jae-Ho;Lee, Jin-Moo;Lee, Chang-Hoon;Cho, Jung-Hoon;Jang, Jun-Bock;Lee, Kyung-Sub;Choi, Jae-Ho
    • Journal of Oriental Medical Thermology
    • /
    • v.5 no.1
    • /
    • pp.1-13
    • /
    • 2006
  • Objectives : This study was designed to analyze basic data for cold hypersensitivity patients with a questionnaire and investigate correlation between cold hypersensitivity and Heart Rate Variability(HRV). Methods : 49 patients who complain of cold hypersensitivity on hands and feet in ambulatory care were investigated in Oriental Gynecology, Kyunghee Oriental Medical Center and Women medical center, Kangnam Koreana hospital from May 1, 2006 to October 20, 2006. All patients were asked to answer a questionnaire. After careful I examination to rule out other disease which may affect Digital Infrared Thermal Imaging(DITI) and HRV data, patients were taken thermography for the diagnosis of cold hypersensitivity Based on the result of thermography, the patients were divided into two groups(Objective cold hypersensitivity and Subjective cold hypersensitivity). Then, these two groups were compared using HRV data which was measured in the supine position for 5 minutes. Results: 1. For most patients, cold hypersensitivity first developed during puberty. 2. The parts of the body that felt cold first time were hands and feet. 3. The cold sensation was increased in winter or at bedtime Showing that the sensation can be changed according to the level of coldness. 4. Among women who sufferfrom cold hypersensitivity, very few of them were treated. 5. More than half of cold hypersensitivity patients's family member also had a cold hypersensitivity. 6. The decrease in mean values of LF/HF ratio was observed in objective cold hypersensitivity group than subjective cold hypersensitivity group and the decrease was significant(P=0.014) when examined by Student t-test. Conclusions : It is necessary that the cold hypersensitivity patients should be treated carefully considering the facts mentioned above. And it can be suggested that dysautinomia be related with cold hypersensitivity and be evaluated by HRV.

  • PDF

Fabrication of Silicon Window for Low-price Thermal Imaging System (저가형 열영상 시스템을 위한 실리콘 윈도우 제작)

  • Sung, Byung Mok;Jung, Dong Geon;Bang, Soon Jae;Baek, Sun Min;Kong, Seong Ho
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.264-269
    • /
    • 2015
  • An infrared (IR) bolometer measures the change of resistance by absorbing incident IR radiation and generates a signal as a function of the radiation intensity. Since a bolometer requires temperature stabilization and light filtering except for the infrared rays, it is essential for the device to be packaged meeting conditions that above mentioned. Minimization of heat loss is needed in order to stabilize temperature of bolometer. Heat loss by conduction or convection requires a medium, so the heat loss will be minimized if the medium is a vacuum. Therefore, vacuum packaging for bolometer is necessary. Another important element in bolometer packaging is germanium (Ge) window, which transmits IR radiation to heat the bolometer. To ensure a complete transmittance of IR light, anti-reflection (AR) coatings are deposited on both sides of the window. Although the transmittance of Ge window is high for IR rays, it is difficult to use frequently in low-price IR bolometer because of its high price. In this paper, we fabricated IR window by utilizing silicon (Si) substrate instead of Ge in order to reduce the cost of bolometer packaging. To enhance the IR transmittance through Si substrate, it is textured using Reactive Ion Etching (RIE). The texturing process of Si substrate is performed along with the change of experimental conditions such as gas ratio, pressure, etching time and RF power.

A Study on Wear-type Defects of Part and Materials in Wind Power Generation (풍력발전기 부품소재의 마모결함 검출에 관한 연구)

  • Kim, Sung-Hyun;Choi, Seung-Hyun;Jung, Na-Ra;Yoon, Cheon-Han;Kim, Jae-Yeol
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.6
    • /
    • pp.989-995
    • /
    • 2013
  • Unlike fossil-or nuclear fuel-based power generation, wind power generation using inexhaustible wind energy is a pollution-free, hazardless power generation method. In this study, ultrasound thermography is used for fabricating specimens of wind power generator bearings and wind power generator supplement flanges, and an optimally designed ultrasound horn and ultrasound excitation system are used for detecting damage to part materials of a wind power generation setup. In addition, thermal flow analysis and ultrasonic thermography imaging are comparatively analyzed for improving the detection reliability in terms of surface and internal defects of part materials and for verifying the developed system's field applicability and reliability.

Effects on the Thermal Changes of Kok-Chi$(LI_{11})$ and Yong-Hyang$(LI_{20})$ Following Acupuncture on Hap-Kok $(LI_{4})$ in Man (합곡(合谷)$(LI_4)$ 자침(刺鍼)이 곡지(曲池)$(LI_{11})$와 영향(迎香)$(LI_{20})$ 영역(領域) 온도변화(溫度變化)에 미치는 영향(影響))

  • Song, Jae-Soo;An, Seong-Hun;Kim, Jae-Hyo;Kim, Kyung-Sik;Sohn, In-Chul
    • The Journal of Korean Medicine
    • /
    • v.19 no.2
    • /
    • pp.271-295
    • /
    • 1998
  • This study was performed from October 1997 to March 1998 on 42 healthy students to observe the effects of acupuncture at Hap-kok (LI4) according to the meridian and qi-xue(氣血) phenomenon of oriental medicine's theory. Skin temperature on the Kok-Chi(LI11) and Yong-Hyang(LI20) were measured by D. I. T. I. (Digital Infrared Thermograph Imaging) before acupuncture stimulation, 1min after and after acupuncture stimulation during 10 min. 1. In healthful man, average skin temperature about Kok-Chi area was in low than Yong-Hyang, and temperature change for 10 min was decreased significantly. 2. In Kok-Chi, the temperature decrease index of execution was shown in low than control. 3. When the temperature of Yong-Hyang(left) was higher, the index was shown in high than control. 4. When the temperature of Kok-Chi (left) was higher, execution temperature change was decreased significantly than control. The above results indicates that D. I. T. I. was a useful method to observe follow-up the effects and changes by acupuncture stimulation on objective evaluation of phenomenon for the meridian system. Thus, acupuncture on LI4 affects to thermal changes of ST25 and LI4, but exact examination of thermal changes on ST25 will have to be.

  • PDF

DEVELOPMENT OF THE MECHANICAL STRUCTURE OF THE MIRIS SOC (MIRIS 우주관측카메라의 기계부 개발)

  • Moon, B.K.;Jeong, W.S.;Cha, S.M.;Ree, C.H.;Park, S.J.;Lee, D.H.;Yuk, I.S.;Park, Y.S.;Park, J.H.;Nam, U.W.;Matsumoto, Toshio;Yoshida, Seiji;Yang, S.C.;Lee, S.H.;Rhee, S.W.;Han, W.
    • Publications of The Korean Astronomical Society
    • /
    • v.24 no.1
    • /
    • pp.53-64
    • /
    • 2009
  • MIRIS is the main payload of the STSAT-3 (Science and Technology Satellite 3) and the first infrared space telescope for astronomical observation in Korea. MIRIS space observation camera (SOC) covers the observation wavelength from $0.9{\mu}m$ to $2.0{\mu}m$ with a wide field of view $3.67^{\circ}\times3.67^{\circ}$. The PICNIC HgCdTe detector in a cold box is cooled down below 100K by a micro Stirling cooler of which cooling capacity is 220mW at 77K. MIRIS SOC adopts passive cooling technique to chill the telescope below 200 K by pointing to the deep space (3K). The cooling mechanism employs a radiator, a Winston cone baffle, a thermal shield, MLI (Multi Layer Insulation) of 30 layers, and GFRP (Glass Fiber Reinforced Plastic) pipe support in the system. Optomechanical analysis was made in order to estimate and compensate possible stresses from the thermal contraction of mounting parts at cryogenic temperatures. Finite Element Analysis (FEA) of mechanical structure was also conducted to ensure safety and stability in launching environments and in orbit. MIRIS SOC will mainly perform Galactic plane survey with narrow band filters (Pa $\alpha$ and Pa $\alpha$ continuum) and CIB (Cosmic Infrared Background) observation with wide band filters (I and H) driven by a cryogenic stepping motor.

Clinical Study on a Case of Cervical Myelopathy (경추증성 척수증 환자 1례에 대한 임상적 고찰)

  • Lee, Ok-ja;Yoon, Min-young;Kim, Hong-hun;Cho, Nam-geun
    • Journal of Acupuncture Research
    • /
    • v.20 no.4
    • /
    • pp.220-229
    • /
    • 2003
  • Objective : Cervical myelopathy is one of the most severe disease, as well as a common diesaes. However, its clinical study and report about efficiency of oriental treatment are absolutely insufficient. Therefore, we report the treatment about 1 case of Cervical myelopathy like followings. Methods : From November 27th, 2002 to January 11th, 2003, we observed patient hospitalized because of cervical myelopathy, and for its valuation, JOA score(Japanese Orthopedic Association score), Nutric grading, VAS(visual analog scale), and D.I.T.I(Digital Infrared Thermal Imaging)were used. Results : After being hospotalized for 50 days, the patients' JOA score, Nuric grading system, and VAS were improved each from 7 to 13, from grade IV to grade II, and from 8 to 2. Conclusions : We considered that oriental treatment has an useful effect on cervical myelopathy patients' treatment and recovery. But continuous studies, such as comparative studies accompanied by more treatment case.

  • PDF