• Title/Summary/Keyword: Infrared thermal imaging system

Search Result 109, Processing Time 0.024 seconds

The performance evaluation of Stirling cryocooler for thermal imaging system (III) : Thermal environmental test (열상장비용 스터링 극저온 냉동기 특성평가 (III) : 열환경시험)

  • 김양훈;박성제;홍용주;김효봉;고득용;이승홍;나종문
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.163-166
    • /
    • 2003
  • This paper presents the results of a series of performance tests for the Stilting cryocooler. Infrared sensor systems incorporating cryocoolers are required to be qualified to the appropriate environmental specification. Linear drive Stilting cryocooler have matured to the stage of undergoing formal qualification test program The thermal environmental test of the Stilting cryocooler is presented in this paper. We performed that low and high temperature keeping test from -4$0^{\circ}C$ to +6$0^{\circ}C$ and operating test at high and low temperature cyclic range with acceptance tests performed at scheduled intervals. Cooling capacity was determined as a function of cooler components temperatures at the compressor, hot end and cold tip. Tests performed on this cooler have been successful with a measured cooling performance of more than 0.8W@80K for 23$^{\circ}C$ ambient temperature with 40 $W_{ac}$ input power.

  • PDF

Development of Smart-phone based Thermal Imaging Diagnostic System for Monitoring Disc Pads of Crane (크레인 디스크 패드 모니터링을 위한 스마트폰 기반의 열영상 진단 시스템 개발)

  • Oh, Yeon-Jae;Park, Kyoung-Wook;Kim, Eung-Kon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.9 no.12
    • /
    • pp.1397-1404
    • /
    • 2014
  • Grab cranes are used for multi-purpose when the sand and soil are deposited into harbor wharf or the undersea construction is performed. Among the components of crane grab, the wire drum and disc brake pad are key expendables and have disadvantages that lot of heat is generated and very expensive when replacing them. In this study, the thermal image analysis for the disc brake, which works with wire drum of the crane is suggested. The suggested system performs the pad thermal diagnosis through the thermal image using the characteristics that the disc and pad surface temperatures are distributed abnormally before the brake failure and the disc pad damage. Therefore, the damage by the failure can be prevented by discovering the abnormality of the machine parts before failure and the life cycle of the pad and the cost can be extended and saved by operating the crane performing constant checkup for the overload.

Conceptual Design Study of NISS onboard NEXTSat-1

  • Jeong, Woong-Seob;Park, Sung-Joon;Park, Kwijong;Lee, Dae-Hee;Moon, Bongkon;Pyo, Jeonghyun;Park, Youngsik;Kim, Il-Joong;Park, Won-Kee;Lee, Duk-Hang;Park, Chan;Ko, Kyeongyeon;Nam, Ukwon;Han, Wonyong;Im, Myungshin;Lee, Hyung Mok;Lee, Jeong-Eun;Shin, Goo-Hwan;Chae, Jangsoo
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.2
    • /
    • pp.82.2-82.2
    • /
    • 2013
  • The NISS (Near-infrared Imaging Spectrometer for Star formation history) onboard NEXTSat-1 is being developed by KASI. The NISS will perform the imaging low-resolution spectroscopic observation in the near-infrared range for nearby galaxies, low background regions, starforming regions and so on. The off-axis reflecting telescope with a wide field of view (2 deg. ${\times}$ 2 deg.) will be operated in the wavelength range from 0.95 to $3.8{\mu}m$. In order to reduce thermal noise, a telescope and a HgCdTe infrared sensor will be cooled down to 200K and 80K, respectively. To evade a stray light outside a field of view and use limited space efficiently, the NISS adopted the off-axis reflective optical system. The primary and secondary mirrors, optomechanical part and mechanical structure were designed to use the same material. It will lessen the degradation of optical performance due to a thermal variation. The purpose of NISS is the observation of cosmic near-infrared background in the wide wavelength range as well as the detection of near-infrared spectral lines in nearby galaxies, cluster of galaxies and star forming regions. It will give us less biased information on the star formation history. In addition, we will demonstrate the space technologies related to the development of the Korea's leading near-infrared instrument for the future large infrared telescope, SPICA.

  • PDF

Implementation of BSCT $320{\times}240$ IR-FPA for Uncooled Thermal Imaging System (비냉각 열 영상 시트템용 BSCT $320{\times}240$ IR-FPA의 구현)

  • Kang, Dae-Seok;Shin, Gyeong-Uk;Park, Jae-U;Yoon, Dong-Han;Song, Seong-Hae;Han, Myeong-Su
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.11
    • /
    • pp.7-13
    • /
    • 2002
  • BSCT 320${\times}$240 IRFPA detector module is implemented, which is a key component in uncooled thermal imaging systems. The detector module consists of two parts, infrared sensitive pixel array and read-out integrated circuit(ROIC). The BSCT 320${\times}$240 pixels are made by laser scribe process and 10-${\mu}m$ micro-bump to satisfy 50-${\mu}m$ pitch and 95-% fill-factor. The ROIC has been designed to electrically address the pixels sequentailly and to improve signal-to-noise ratio with single transistor amplifier, HPF, tunable LPF and clamp circuit. The fabricated hybrid chip of detector and ROIC has been mounted on the TEC built-in ceramic package for more stable operation and tested for lots of electrical and optical properties. The IRFA sample has shown successful properties and met with good results of fill-factor, detectivity and responsivity.

Manufacture of Aspheric Lens Using Thermal Image Optics (열영상 광학계용 비구면 렌즈 제작)

  • Kim, Dae-Jung;Gu, Hal-Bon;Kim, Shang-Suk;Kim, Jeong-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.191-194
    • /
    • 2003
  • Through using aspheric lens can result in advantages such as an improved optical transfer function, a reduced distortion path or the realization of special image field curvatures. Using the diamond turning method for generating aspherics, the company claim to be able to generate surfaces with a form error of less than $0.33\;{\mu}\;m$ and a surface roughness of less than $0.025\;{\mu}\;m$. In this paper, we are manufacturing thermal image aspheric lens. Thermal image system is electro-optical imaging device which can make visible the difference of infrared energy naturally emitted by objected. In the result of aspherical surface, the form accuracy of about $0.24\;{\mu}\;m$ P-V was obtained and the surface roughness Ra $0.004\;{\mu}\;m$. Also, a brief review of Ultra-precision system Korea photonics technology institute(KOPTI) is present in this paper.

  • PDF

Ultra Precision Machining Technique for Optical System Parts (초정밀 가공기를 활용한 광학계 부품 가공기술)

  • Yang, Sun-Choel;Kim, Sang-Hyuk;Huh, Myung-Sang;Chang, Ki-Soo;Park, Soon-Sub;Won, Jong-Ho;Kim, Geon-Hee
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.2
    • /
    • pp.13-19
    • /
    • 2012
  • Ultra Precision Machining Techniques, such as manufacturing Micro Lens Array(MLA), off-axis mirror, $F-{\theta}$ lens for laser printer, are achieved, based on technologies in consequence of development of modern high-precision machining mechanism. Above all, FTS(Fast Tool Servo) and STS(Slow Tool Servo) are more innovative technologies for reducing time and development costs. In this paper, it is described that MLA machining technique by FTS, off-axis mirror machining technique by STS, optics for observing space, and development of infrared aspheric lens for a thermal imaging microscope.

Common Optical System for the Fusion of Three-dimensional Images and Infrared Images

  • Kim, Duck-Lae;Jung, Bo Hee;Kong, Hyun-Bae;Ok, Chang-Min;Lee, Seung-Tae
    • Current Optics and Photonics
    • /
    • v.3 no.1
    • /
    • pp.8-15
    • /
    • 2019
  • We describe a common optical system that merges a LADAR system, which generates a point cloud, and a more traditional imaging system operating in the LWIR, which generates image data. The optimum diameter of the entrance pupil was determined by analysis of detection ranges of the LADAR sensor, and the result was applied to design a common optical system using LADAR sensors and LWIR sensors; the performance of these sensors was then evaluated. The minimum detectable signal of the $128{\times}128-pixel$ LADAR detector was calculated as 20.5 nW. The detection range of the LADAR optical system was calculated to be 1,000 m, and according to the results, the optimum diameter of the entrance pupil was determined to be 15.7 cm. The modulation transfer function (MTF) in relation to the diffraction limit of the designed common optical system was analyzed and, according to the results, the MTF of the LADAR optical system was 98.8% at the spatial frequency of 5 cycles per millimeter, while that of the LWIR optical system was 92.4% at the spatial frequency of 29 cycles per millimeter. The detection, recognition, and identification distances of the LWIR optical system were determined to be 5.12, 2.82, and 1.96 km, respectively.

Clinical Case Study of Facial Nerve Palsy Using Facial Acupuncture (안면 성형침을 이용한 안면신경마비 치험 2례)

  • Chu, Min-Gyu;Jo, Hee-Guen;Choi, Jin-Bong;Kim, Sun-Jong;Park, Kyung-Mi;Cho, Gook-Ryung;Lee, Hyun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.5
    • /
    • pp.1188-1192
    • /
    • 2009
  • Facail nerve palsy is a common disease in the face. This disease is treated by many methods. But it is not treated by Facial Acupunture. Therefore we performed to evaluate the effect of Facial Acupuncture with oriental dedical treatment in facail nerve palsy. This clinical study was carried out 2 caese of facail nerve palsy which had been admitted our hospital. In this study the patients were treated by Facail Acupuncture. Other treatment were herbal medication, regabilitative therapy. H-B scale(House-Brackmann facial nerve grading system) and Digital Infrared Thermal Imaging were measured from admission to discharge. After being treated by our methods, Patients' H-B scale and Inequality of Facial DITI were improved in cases compared to existing. In the study, The treatment of facial nerve palsy using Facial acupuncture was more effective, especially H-B scale, Digital Infrared Thermal Imaging and treatment period, compared to existing.

The Introduction to MODIS Ground Pre-processing System and Application Fields (MODIS 처리시스템 및 활용분야 소개)

  • 서두천;임효숙;전정남;김재관
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2003.04a
    • /
    • pp.271-276
    • /
    • 2003
  • The Moderate Resolution Imaging Spectroradiometer (MODIS) on the Earth Observing System (EOS) of Terra and Aqua satellites, launched in December 1999 and May 2002, has been directly received by Korea Aerospace Research Institute (KARI) ground station facility from July 2002. MODIS scans a swath width of 2330 km that is sufficiently wide to cover Korean peninsular, Yellow and East Sea at once. The MODIS has 36 spectral bands between 0.415 $\mu\textrm{m}$ and 14.235 $\mu\textrm{m}$, i.e., through the visible into the thermal infrared. MODIS has been observed active fires, floods, smoke transport, dust storms, severe storms since February of 2000. The satellite imagery obtained through the MODIS will be utilized for many application such as national territorial management, agriculture, natural environment, atmosphere and ocean, etc. In this study is to introduce various application field of MODIS imagery and data processing system.

  • PDF

OPTO-MECHANICAL DESIGN OF THE KASINICS (KASINICS의 광기계부 설계)

  • Yuk, I.S.;Lee, S.L.;Jin, H.;Seon, K.I.;Pak, S.;Lee, D.H.;Nam, U.W.;Moon, B.K.;Cha, S.M.;Han, J.Y.;Kyeong, J.M.;Kim, K.H.;Yang, J.S.
    • Publications of The Korean Astronomical Society
    • /
    • v.20 no.1 s.24
    • /
    • pp.143-149
    • /
    • 2005
  • KASI (Korea Astronomy and Space Science Institute) is developing the near-infrared camera system named KASINICS (KASI Near-Infrared Camera System) which will be installed at the 60cm f/13.5 Ritchey-Chretien telescope of the Sobaeksan Optical Astronomy Observatory (SOAO). The camera system is optimized for JHKL bands and has a 6 arcmin FOV. The optical system consists of two spherical mirrors and a 8-position filter wheel. With the exception for the dewar window, all optical elements are cooled inside cryogenic dewar. Since the Offner system is adopted to prevent thermal noises from outside of the telescope primary mirror, the secondary mirror of the Offner system acts as a cold Lyot stop. The optical performance does not change by temperature variations because the Aluminum mirrors contract and expand homogeneously with its mount. We finished the design and fabrication of the optical parts and are now aligning the optical system. We plan to have a test observation on 2006 January.