• 제목/요약/키워드: Infrared light source

검색결과 114건 처리시간 0.022초

Cloud-Type Classification by Two-Layered Fuzzy Logic

  • Kim, Kwang Baek
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제13권1호
    • /
    • pp.67-72
    • /
    • 2013
  • Cloud detection and analysis from satellite images has been a topic of research in many atmospheric and environmental studies; however, it still is a challenging task for many reasons. In this paper, we propose a new method for cloud-type classification using fuzzy logic. Knowing that visible-light images of clouds contain thickness related information, while infrared images haves height-related information, we propose a two-layered fuzzy logic based on the input source to provide us with a relatively clear-cut threshold in classification. Traditional noise-removal methods that use reflection/release characteristics of infrared images often produce false positive cloud areas, such as fog thereby it negatively affecting the classification accuracy. In this study, we used the color information from source images to extract the region of interest while avoiding false positives. The structure of fuzzy inference was also changed, because we utilized three types of source images: visible-light, infrared, and near-infrared images. When a cloud appears in both the visible-light image and the infrared image, the fuzzy membership function has a different form. Therefore we designed two sets of fuzzy inference rules and related classification rules. In our experiment, the proposed method was verified to be efficient and more accurate than the previous fuzzy logic attempt that used infrared image features.

음압에 의해 생성된 멍 촬영을 위한 적외선 광원과 필터 조합에 관한 연구 (Combination of Infrared Light Source and Barrier Filter for Suction Bruise Photography)

  • 김주은;김지연;전소영;김은아;유제설
    • 한국콘텐츠학회논문지
    • /
    • 제16권11호
    • /
    • pp.693-698
    • /
    • 2016
  • 학대나 폭력을 입증할 수 있는 증거 중 하나인 멍은 크게 외력에 의한 것과 음압에 의한 것으로 나뉜다. 외력에 의해 생성된 멍에 관한 연구는 많지만, 음압에 의해 생성된 멍에 관한 연구는 적다. 적외선 광원으로 멍을 촬영한 선행연구들을 살펴보면 하나의 적외선 광원과 필터만을 사용하여 실험했다는 문제점이 있다. 본 실험의 연구자들은 적외선 광원과 필터의 조합에 따라 멍의 촬영 결과물이 다른 양상을 보일 것으로 생각하였다. 따라서 세 종류의 적외선 광원과 다섯 종류의 적외선 필터를 사용하여 음압에 의해 생성된 멍을 촬영하는데 최적의 조합을 찾고자 하였다. 그 결과 750 nm 영역을 포함하는 텅스텐과 이 영역을 투과시키는 필터인 Kodak Wratten #18A를 사용했을 때 가장 좋은 결과를 얻을 수 있었다.

Near-Infrared Light Propagation in an Adult Head Model with Refractive Index Mismatch

  • Kim, Seung-Hwan;Lee, Jae-Hoon
    • ETRI Journal
    • /
    • 제27권4호
    • /
    • pp.377-384
    • /
    • 2005
  • We investigate near-infrared light (NIR) propagation in a model of an adult head using an extensive Monte Carlo (MC) simulation. The adult head model is a four-layered slab which consists of a surface layer, a cerebrospinal fluid layer, a gray-matter layer, and a white-matter layer. We study the effects of a refractive index mismatch on the model, calculating the intensity of detected light, mean flight time, and partial mean flight time of each layer for various refractive indices of the cerebrospinal fluid layer as functions of source-detector spacing. The Monte Carlo simulation shows that the refractive index mismatch presents very rich results including rapidly decaying intensity of detected light and a peak and cross-over in the partial mean flight time with source-detector spacing. We also investigate spatial sensitivity profiles at various source-detector spacings, discussing the index mismatch effect on the model.

  • PDF

적외선 복사에 의한 시료의 온도상승과 온도분포 측정 (Measurements of Temperature Rise and Temperature Distribution of Samples by Infrared Radiation)

  • 한종성;김기훈;김훈
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.133-137
    • /
    • 2003
  • When a light is projected upon a material, part of its radiation energy is absorbed and the rest is reflected or transmitted according to the nature of the material. The molecules of the substance absorbing a light obtains the radiation energy to the wavelength of the light to make photochemical degradation by ultraviolet ray or thermal reactions like physical damage by infrared ray. The degree of damage by radiation energy varies to the substances of materials, the spectral power distribution of the light source and the duration of irradiation. Because the damage brings about a devaluation of material and once damaged, it is irretrievable, it is necessary to minimize the damage and conserve the native quality of a material by a protective lighting system. A measuring system was set up to measure the temperature rise of each sample by infrared radiation from light sources. And the temperature rise and temperature distribution by various infrared lamps were measured with varying time.

  • PDF

Conversion of Organic Carbon in Food Processing Wastewater to Photosynthetic Biomass in Photo-bioreactors Using Different Light Sources

  • Suwan, Duangkamon;Chitapornpan, Sukhuma;Honda, Ryo;Chiemchaisri, Wilai;Chiemchaisri, Chart
    • Environmental Engineering Research
    • /
    • 제19권3호
    • /
    • pp.293-298
    • /
    • 2014
  • An anaerobic photosynthetic treatment process utilizing purple non-sulfur photosynthetic bacteria (PNSB) was applied to the recovery of organic carbon from food processing wastewater. PNSB cells, by-product from the treatment, have high nutrition such as proteins and vitamins which are a good alternative for fish feed. Effects of light source on performance of anaerobic photosynthetic process were investigated in this study. Two bench-scale photo-bioreactors were lighted with infrared light emitting diodes (LEDs) and tungsten lamps covered with infrared transmitting filter, respectively, aiming to supply infrared light for photosynthetic bacteria growth. The photo-bioreactors were operated to treat noodle-processing wastewater for 323 days. Hydraulic retention time (HRT) was set as 6 days. Organic removals in the photo-bioreactor lighted with infrared LEDs (91%-95%) was found higher than those in photo-bioreactor with tungsten lamps with filter (79%-83%). Biomass production in a 150 L bench-scale photo-bioreactor was comparable to a 8 L small-scale photo-bioreactor in previous study, due to improvement of light supply efficiency. Application of infrared LEDs could achieve higher treatment performance with advantages in energy efficiency and wavelength specifity.

세상에서 가장 얇은 그래핀 발광 소자 (The World's Thinnest Graphene Light Source)

  • 김영덕
    • 진공이야기
    • /
    • 제4권3호
    • /
    • pp.16-20
    • /
    • 2017
  • Graphene has emerged as a promising material for optoelectronic applications including as ultrafast and broadband photodetector, optical modulator, and nonlinear photonic devices. Graphene based devices have shown the feasibility of ultrafast signal processing for required for photonic integrated circuits. However, on-chip monolithic nanoscale light source has remained challenges. Graphene's high current density, thermal stability, low heat capacity and non-equilibrium of electron and lattice temperature properties suggest that graphene as promising thermal light source. Early efforts showed infrared thermal radiation from substrate supported graphene device, with temperature limited due to significant cooling to substrate. The recent demonstration of bright visible light emission from suspended graphene achieve temperature up to ~3000 K and increase efficiency by reducing the heat dissipation and electron scattering. The world's thinnest graphene light source provides a promising path for on-chip light source for optical communication and next-generation display module.

NEW DEVELOPED PORTABLE NEAR INFRARED (NIR) SYSTEM USING MICROSPECTROMETER

  • Woo, Young-Ah;Ha, Tae-Kyu;Kim, Jae-Min;Kim, Hyo-Jin
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1123-1123
    • /
    • 2001
  • In recent years, a miniature spectrometer has been extensively developed due to the marriage of fiber optics and semiconductor detector array. This type of miniature spectrometer has advantages of low price and robustness due to the capability of mass production and no moving parts are required such as lenses, mirrors and scanning monochromator. These systems are ideal for use in teaching labs, process monitoring and field analyses. A portable near infrared (NIR) system has been developed for qualitative and quantitative analysis. This system includes a tungsten halogen lamp for light source, a fiber optics connected a light source, and a sample module to the microspectrometer, The size of spectrometer can be as small as 2.5 cm x 1.5 cm x 0.1 cm. Wavelength ranges can be chosen as 360-800 nm, 800-1100 nm and 1100-1900 nm depending on the type of detector. The software consists of various tools for multivariate analysis and pattern recognition techniques. To evaluate the system, long and short-term stability, wavelength accuracy, and stray light have been investigated and compared with conventional scanning type NIR spectrometer. This developed system can be sufficiently used for quantitative and qualitative analysis for various samples such as agricultural product, herbal medicine, food, petroleum, and pharmaceuticals, etc.

  • PDF

복사조도의 번동에 따른 온도 및 적외선복사량의 변화 (A Change in the Temperature and Infrared Radiation as a Variation of Irradiance)

  • 한종성;김기훈;김훈
    • 조명전기설비학회논문지
    • /
    • 제19권2호
    • /
    • pp.28-34
    • /
    • 2005
  • 적외선복사에 의한 열적 반응은 물질의 온도상승이나 온도하강 등의 과정을 통하여 물질의 물리적 손상을 초래한다. 본 연구에서는 광원의 적외선복사에 의한 시료의 온도상승과 적외선복사량을 측정할 수 있는 측정시스템을 구축하고, 전시조명용으로 많이 사용하는 광원들을 대상으로 각 광원의 복사조도를 변화시키면서 온도변화와 적외선 복사량의 변화를 각각 측정하였다. 측정의 결과를 토대로 복사조도와 온도 및 적외선복사량간의 함수관계를 파악하고, 복사조도의 변동에 따른 온도변화 및 적외선복사량의 변화를 비교, 분석하였다.

적외선 복사에너지에 의한 시료의 물리적 손상 측정 (Measurement of Physical Demage of Samples by Infrared Radiation)

  • 정동선;김기훈;한종성;김훈
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.131-135
    • /
    • 2004
  • The molecules of the substance absorbing a light obtains the radiant energy to the wavelength of the light to make thermal reactions or photochemical reactions. Specially, thermal reactions by infrared radiation brings about physical damage by temperature rise process or temperature drop process of the material. In this study, a measuring system was set up to measure the temperature rise and temperature drop of each sample by infrared radiation from light source. And a physical demage of samples by infrared radiation were measured using the measuring system.

  • PDF

Infrared Light Absorbance: a New Method for Temperature Compensation in Nondispersive Infrared CO2 Gas Sensor

  • Yi, Seung Hwan
    • 센서학회지
    • /
    • 제29권5호
    • /
    • pp.303-311
    • /
    • 2020
  • Nondispersive infrared CO2 gas sensor was developed after the simulation of optical cavity structure and assembling the optical components: IR source, concave reflectors, Fresnel lens, a hollow disk, and IR detectors. By placing a hollow disk in front of reference IR detector, the output voltages are almost constant value, near to 70.2 mV. The absorbance of IR light, Fa, shows the second order of polynomial according to ambient temperatures at 1,500 ppm. The differential output voltages and the absorbance of IR light give a higher accuracy in estimations of CO2 concentrations with less than ± 1.5 % errors. After implementing the parameters that are dependent upon the ambient temperatures in microcontroller unit (MCU), the measured CO2 concentrations show high accuracies (less than ± 1.0 %) from 281 K to 308 K and the time constant of developed sensor is about 58 sec at 301 K. Even though the estimation errors are relatively high at low concentration, the developed sensor is competitive to the commercial product with a high accuracy and the stability.