• Title/Summary/Keyword: Infrared lamp

Search Result 118, Processing Time 0.022 seconds

A Background Subtraction Algorithm for Fence Monitoring Surveillance Systems (담장 감시 시스템을 위한 배경 제거 알고리즘)

  • Lee, Bok Ju;Chu, Yeon Ho;Choi, Young Kyu
    • Journal of the Semiconductor & Display Technology
    • /
    • v.14 no.3
    • /
    • pp.37-43
    • /
    • 2015
  • In this paper, a new background subtraction algorithm for video based fence monitoring surveillance systems is proposed. We adopt the sampling based background subtraction technique and focus on the two main issues: handling highly dynamic environment and handling the flickering nature of pulse based IR (infrared) lamp. Natural scenes from fence monitoring system are usually composed of several dynamic entities such as swaying trees, moving water, waves and rain. To deal with such dynamic backgrounds, we utilize the confidence factor for each background value of the input image. For the flickering IR lamp, the original sampling based technique is extended to handle double background models. Experimental results revealed that our method works well in real fence monitoring surveillance systems.

Comparison of the Effects of Luminous Lamp, and Nonluminous Lamp Radiation on Experimental Pain Threshold Sensitivity (발광·무광 적외선등 조사가 실험적 통증역치에 미치는 효과 비교)

  • Lim, In-Hyuk;Lee, Jeong-Weon;Cho, Su-Won
    • Physical Therapy Korea
    • /
    • v.9 no.3
    • /
    • pp.1-9
    • /
    • 2002
  • The purpose of this study was to compare the experimental pain threshold when used in luminous lamp radiation and nonluminous lamp radiation with healthy person. Thirty normal subjects were randomly assigned two groups: a luminous lamp radiation group, and a nonluminous lamp radiation group. The infrared lamps were applied on L3 for thirty minutes. Each group was measured for experimental pain threshold and local temperature before, 15 and 30 minute radiation. For statistical differences in change of the experimental pain threshold and local temperature due to differences in lamp ray was compared using the independent t-test. And, General linear model for profile plots test was used. The results were as: 1. Local temperature was significantly increased in the nonluminous lamp group (p<.01). 2. Experimental pain thershold was significantly increased in the luminous lamp group (p<.05),(p<.01). This study indicate that luminous lamp radiation was more effects of increase experimental pain thershold than nonluminous lamp radiation. Further study is needed to compare the effects of after period radiation.

  • PDF

A study on the Drying Characteristics of NIR Dryer (근 적외선 건조기의 건조특성에 대한 연구)

  • Jang, Yeong-Suk
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.1
    • /
    • pp.21-27
    • /
    • 2004
  • Near Infrared Ray (NIR) are primarily of interest to the high energy physicist. It is the intermediate portion of the spectrum, which extends from approximately 0.8 to 1.5 ${\mu}m$ and include a portion of the all of infrared, that is thermal radiation and is pertinent to heat transfer. It is important to study that temperature distribution of the drying materials by surface encompasses a range of NIR wave lengths. This study is to investigate the characteristics of NIR dryer by experimental results. it was made a comparison with various textiles, velocity ratio and distance of lamp and textiles. In case of spongy type textile the drying performance is the superior of all. The 0.15m distance drying effect of improvement 30% more than 0.26m distance between lamp and textiles. As the contained water increases, the drying speed for textile can be increased.

Non-dispersive infrared carbon dioxide sensor with an externally exposed optical cavity (광 도파관이 외부로 노출된 구조를 가지는 비분산적외선 이산화탄소 센서)

  • Jung, Dong Geon;Lee, Junyeop;Do, Nam Gon;Jung, Daewoong
    • Journal of Sensor Science and Technology
    • /
    • v.30 no.6
    • /
    • pp.456-460
    • /
    • 2021
  • In this study, a Non-Dispersive Infrared (NDIR) Carbon Dioxide (CO2) sensor with an externally exposed optical cavity is proposed for improving sensitivity. NDIR CO2 sensors with high performance must use a lamp-type infrared (IR) source with a strong IR intensity. However, a lamp-type IR source generates high thermal energy that induces thermal noise, interfering with the accuracy of the CO2 concentration measure. To solve this problem, the optical cavity of the NDIR CO2 sensor is exposed to quickly dissipate heat. As a result, the proposed NDIR CO2 sensor has a shorter warm-up time and a higher sensitivity compared to the conventional NDIR CO2 sensor.

Electrical characteristics of 28W fluorescent lamp ballast using piezoelectric transformer (압전트랜스포머를 이용한 28W 형광등 안정기의 전기적 특성)

  • 황상모;이정선;류주현;홍재일;정영호;손은영;박창엽
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.198-202
    • /
    • 2001
  • In this study, contour vibration mode piezoelectric transformer with size of 27.5${\times}$27.5${\times}$2.6mm$^3$ using PNW-PMN-PZT ceramic was fabricated. And the piezoelectric transformer was adopted to fluorescent lamp ballast circuit. Electrical characteristics of the piezoelectric transformer were investigated for fluorescent lamp ballast application. The electrical properties and characteristic temperature rise were measured using oscilloscope and infrared temperature sensor. A 28W fluorescent lamp was successfully driven by the fabricated ballast circuit. After driving the lamp using ballast circuit for 24 min, the output power, efficiency and characteristic temperature rise of piezoelectric transformer showed the appropriate values of 28.85[W], 86.3[%] and 15[$^{\circ}C$], respectively.

  • PDF

Determination of an Test Condition for IR Thermography to Inspect a Wall-Thinning Defect in Nuclear Piping Components (원전 배관 감육 결함 검사를 위한 IR 열화상시험 조건 결정)

  • Kim, Jin-Weon;Yun, Won-Kyung;Jung, Hyun-Chul;Kim, Kyeong-Suk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.1
    • /
    • pp.12-19
    • /
    • 2012
  • This study conducted infrared (IR) thermography tests using pipe and plate specimens with artificial wall-thinning defects to find an optimal condition for IR thermography test on the wall-thinned nuclear piping components. In the experiment halogen lamp was used to heat the specimens. The distance between the specimen and the lamp and the intensity of halogen lamp were regarded as experimental parameter. When the distance was set to 1~2 m and the lamp intensity was above 60 % of full power, a single scanning of IR thermography detected all artificial wall-thinning defects, whose minimum dimension was $2{\Theta}=90^{\circ}$, d/t=0.5, and $L/D_o=0.25$, within the pipe of 500 mm in length. Regardless of the distance between the specimen and the lamp, the image of wall-thinning defect in IR thermography became distinctive as the intensity of halogen lamp increased. The detectability of IR thermography was similar for both plate and pipe specimens, but the optimal test condition for IR thermography depended on the type of specimen.

Fabrication of a polymerase chain reaction micro-reactor using infrared heating

  • Im, Ki-Sik;Eun, Duk-Soo;Kong, Seong-Ho;Shin, Jang-Kyoo;Lee, Jong-Hyun
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.5
    • /
    • pp.337-342
    • /
    • 2005
  • A silicon-based micro-reactor to amplify small amount of deoxyribonucleic acid (DNA) has been fabricated using micro-electro-mechanical systems (MEMS) technology. Polymerase chain reaction (PCR) of DNA requires a precise and rapid temperature control. A Pt sensor is integrated directly in the chamber for real-time temperature measurement and an infrared lamp is used as external heating source for non-contact and rapid heating. In addition to the real-time temperature sensing, PCR needs a rapid thermocycling for effective PCR. For a fast thermal response, the thermal mass of the reactor chamber is minimized by removal of bulk silicon volume around the reactor using double-side KOH etching. The transparent optical property of silicon in the infrared wavelength range provides an efficient absorption of thermal energy into the reacting sample without being absorbed by silicon reactor chamber. It is confirmed that the fabricated micro-reactor could be heated up in less than 30 sec to the denaturation temperature by the external infrared lamp and cooled down in 30 sec to the annealing temperature by passive cooling.

Characterization of Soldering Property on Heating Condition by Infrared Lamp Soldering Process for C-Si Photovoltaic Modules (적외선 램프 가열방식을 이용한 태양전지 셀의 솔더링 공정 및 열처리 조건 별 특성 평가)

  • Son, Hyoun Jin;Lee, Jung Jin;Kim, Sung Hyun
    • Current Photovoltaic Research
    • /
    • v.4 no.2
    • /
    • pp.59-63
    • /
    • 2016
  • A key point of a soldering process for photovoltaic (PV) modules is to increase an adhesive strength leading a low resistivity between ribbon and cell. In this study, we intended to optimize a heating condition for the soldering process and characterize the soldered joint via physical and chemical analysis methods. For the purpose, the heating conditions were adjusted by IR lamp power, heating time and hot plate temperature for preheating a cell. Since then the peel test for the ribbon and cell was conducted, consequently the peel strength data shows that there is some optimum soldering condition. In here, we observed that the peel strength was modified by increasing the heating condition. Such a soldering property is affected by a various factors of which the soldered joint, flux and bus bar of the cell are changed on the heating condition. Therefore, we tried to reveal causes determining the soldering property through analyzing the soldered interface.

Infrared Assisted Freeze-Drying (IRAFD) to Produce Shelf-Stable Insect Food from Protaetia brevitarsis (White-Spotted Flower Chafer) Larva

  • Khampakool, Apinya;Soisungwan, Salinee;You, SangGuan;Park, Sung Hee
    • Food Science of Animal Resources
    • /
    • v.40 no.5
    • /
    • pp.813-830
    • /
    • 2020
  • In this study, the potential of infrared assisted freeze-drying (IRAFD) was tested for the production of shelf-stable edible insects: Protaetia brevitarsis larva (larva of white-spotted flower chafer). The IRAFD system was customized using an infrared lamp, K-type thermocouple, controller, and data acquisition system. The infrared lamp provided the sublimation energy for rapid freeze-drying (FD). The IRAFD conditions were continuous IRAFD-5.0 kW/㎡ and IRAFD-5.0 kW/㎡ at different weight reduction (WR) (10%, 20%, and 30%). The continuous IRAFD reduced the drying time to 247 min compared to the 2,833 min duration of FD (p<0.05). The electrical energy could be reduced by more than 90% through infrared radiation during FD (p<0.05). The Page model resulted in the best prediction among the tested drying kinetic models. In terms of quality, IRAFD showed significantly lower hardness, chewiness, and higher protein levels than hot air drying and FD (p<0.05). IRAFD better preserved the glutamic acid (6.30-7.29 g/100 g) and proline (3.84-5.54 g/100 g). The external product appearance after IRAFD exhibited more air pockets and volume expansion, which might result in a good consumer appeal. In conclusion, this study reports the potential of IRAFD in producing shelf-stable and value-added edible insects.