• Title/Summary/Keyword: Infrared diode

Search Result 123, Processing Time 0.023 seconds

Trends in Broadband Terahertz Detector Technology (광대역 테라헤르츠 검출 소자 기술 동향)

  • Shin, J.H.;Choi, D.H.;Lee, E.S.;Moon, K.W.;Park, D.W.;Joo, K.I.;Kim, M.G.;Choi, K.S.;Lee, I.M.;Park, K.H.
    • Electronics and Telecommunications Trends
    • /
    • v.35 no.4
    • /
    • pp.53-64
    • /
    • 2020
  • The terahertz (THz) region lies in between the millimeter and infrared spectral bands. A THz wave has the characteristics of non-invasiveness and non-ionization due to low photon energies, while having high penetrability in dielectrics. In addition, since the resonance frequencies of various molecules are included in the THz band, research on the application of spectral analysis and non-destructive testing has been widely studied. Towards this end, the research and development of THz detectors has become increasingly important in order to assess their applications in different areas such as astronomy, security, industrial non-destructive evaluations, biological applications, and wireless communications. In this report, we summarize the operating principles, characteristics, and utilization of various broadband technologies in THz detection devices. Further, we introduce the development status of our Schottky barrier diode technology as one of the broadband THz detectors that can be easily adopted as direct detectors in many fields of applications.

Characteristics of Ni/SiC Schottky Diodes Grown by ICP-CVD

  • Gil, Tae-Hyun;Kim, Han-Soo;Kim, Yong-Sang
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.3
    • /
    • pp.111-116
    • /
    • 2004
  • The Ni/SiC Schottky diode was fabricated with the $\alpha$-SiC thin film grown by the ICP-CVD method on a (111) Si wafer. $\alpha$-SiC film has been grown on a carbonized Si layer in which the Si surface was chemically converted to a very thin SiC layer achieved using an ICP-CVD method at $700^{\circ}C$. To reduce defects between the Si and $\alpha$-SiC, the surface of the Si wafer was slightly carbonized. The film characteristics of $\alpha$-SiC were investigated by employing TEM (Transmission Electron Microscopy) and FT-IR (Fourier Transform Infrared Spectroscopy). Sputterd Ni thin film was used as the anode metal. The boundary status of the Ni/SiC contact was investigated by AES (Auger Electron Spectroscopy) as a function of the annealing temperature. It is shown that the ohmic contact could be acquired beyond a 100$0^{\circ}C$ annealing temperature. The forward voltage drop at 100A/cm was I.0V. The breakdown voltage of the Ni/$\alpha$-SiC Schottky diode was 545 V, which is five times larger than the ideal breakdown voltage of the silicon device. As well, the dependence of barrier height on temperature was observed. The barrier height from C- V characteristics was higher than those from I-V.

In Vivo Enhanced Indocyanine Green-Photothermal Therapy for a Subconjunctival Tumor

  • Kim, Chang Zoo;Lee, Sang Joon;Hwang, Sang Seok;Chae, Yu-Gyeong;Kwon, Daa Young;Ko, Taek Yong;Kim, Jun Hyeong;Jung, Min Jung;Masanganise, Rangarirai;Oak, Chulho;Ahn, Yeh-Chan
    • Current Optics and Photonics
    • /
    • v.5 no.3
    • /
    • pp.311-321
    • /
    • 2021
  • Indocyanine green (ICG) is a dye approved for use in clinical diagnostics. ICG remains in the intravascular space following intravenous administration, due to its ability to rapidly bind to the plasma proteins, and its therapeutic potential has been studied in well-vascularized cutaneous tumors. Here we have evaluated the clinical response of a subconjunctival tumor to photothermal therapy (PTT) using an ICG-enhanced near-infrared diode laser and its adverse effects, in a rabbit. 22 male New Zealand white rabbits with subconjunctival tumors were enrolled (control group 6, laser-only group 8, laser-with-ICG group 8). Rabbits in the laser-with-ICG group received ICG (twice, 2 mg/kg each time, intravenously) directly followed by irradiation with a diode laser (λ = 810 nm). Rabbits in the laser-only group were irradiated with the diode laser. ICG angiography, ultrasonography, and pathologic examination were performed to evaluate PTT response at specific time points (0, 2, and 4 weeks after PTT). Two weeks after initial treatment, the eight rabbits treated by laser with ICG showed a 100% response rate. There was no clinical response in both laser-only and control groups. ICG-PTT is a potential and effective palliative therapeutic modality for subconjunctival tumors.

Prototype Implementation of VLC Upstream Transmission Using Focused IR-LED (집광된 IR-LED를 이용한 가시광 통신 상향 전송 프로토타입 구현)

  • Jang, Yunseon;Choi, Kyungmook;Ju, MinChul;Park, Youngil
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37C no.9
    • /
    • pp.784-790
    • /
    • 2012
  • In this paper, we propose a upstream transmission method to extend coverage in visible light communication (VLC) systems. We extend transmission distance by using focused infrared(IR) light emitting diodes(LEDs). Since the focused light covers just limited area, it might have a difficulty in transmitting data if the transmitter and receiver are not properly aligned. To solve this problem, we arrange multiple IR-LEDs in different direction and select a single best performing IR-LED among multiple IR-LEDs. Also, the transmission performance is periodically checked and another IR-LED is reselected to support the required quality of service (QoS) and to minimize battery consumption required by a mobile terminal.

Gaze Detection by Wearable Eye-Tracking and NIR LED-Based Head-Tracking Device Based on SVR

  • Cho, Chul Woo;Lee, Ji Woo;Shin, Kwang Yong;Lee, Eui Chul;Park, Kang Ryoung;Lee, Heekyung;Cha, Jihun
    • ETRI Journal
    • /
    • v.34 no.4
    • /
    • pp.542-552
    • /
    • 2012
  • In this paper, a gaze estimation method is proposed for use with a large-sized display at a distance. Our research has the following four novelties: this is the first study on gaze-tracking for large-sized displays and large Z (viewing) distances; our gaze-tracking accuracy is not affected by head movements since the proposed method tracks the head by using a near infrared camera and an infrared light-emitting diode; the threshold for local binarization of the pupil area is adaptively determined by using a p-tile method based on circular edge detection irrespective of the eyelid or eyelash shadows; and accurate gaze position is calculated by using two support vector regressions without complicated calibrations for the camera, display, and user's eyes, in which the gaze positions and head movements are used as feature values. The root mean square error of gaze detection is calculated as $0.79^{\circ}$ for a 30-inch screen.

A Study on Welding Union by Welding Fume Shape Measurement (용접 Fume 형상 측정에 따른 용접 결합에 관한 연구)

  • Kim J.Y.;Choi C.J.;Kwak N.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.35-36
    • /
    • 2006
  • In Nd:YAG laser welding, evaluation methods of welding flaw are various. But, the method due to fume shape is difficult to classification of welding flaw. The Nd:YAG laser process is known to have high speed and deep penetration capability to become one of the most advanced welding technologies. At the present time, some methods are studied for measurement of fume shape by using high-speed camera and photo diode. This paper describes the machining characteristics of SM45C carbon steel welding by use of an Nd:YAG laser. In spite of its good mechanical characteristics, SM45C carbon steel has a high carbon contents and suffers a limitation in the industrial application due to the poor welding properties. In this study, fume shape was measured by infrared thermal camera that is non-contact/non-destructive thermal measurement equipment through change of laser generating power, speed, focus. Weld was performed on bead-on method. Measurement results are compared as two equipments. Here, two results are composed of measurement results of fume quantities due to fume shape by infrared thermal camera and inspection results of weld bead include weld flaws by ultrasonic inspector.

  • PDF

Fabrication of an IrDA transceiver module for wireless infrared communication system OPR 1002 (850nm 적외선을 이용한 근거리 무선통신 시스템용 송수신 모듈 제작)

  • 김근주
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.1B
    • /
    • pp.175-182
    • /
    • 2000
  • (A hybrid-type wireless infrared data communication module was fabricated by using the light emitting andabsorption diodes with the one-chip of integrated digital circuits. The light emitting diode with the peak spectrum of 850 nm was made from compound semiconductor material of AIGaAs and shows high speed signal transmission with the delay time of 60 nsec for the light direction angle of 30". The Si PIN photodiode showsthe good absorption rate for the range of wavelength of 450-1050 nm and convex-type epoxy lens was utilized for the spectrum filtering on the visible-range spectrum below 750 nm, The data transmission speed is 115.2 kbps and the fabricated module satisfies on the IrDA 1.0 SIR standard requirements.)ments.)

  • PDF

Quantification of Skin Moisture in Hairless Mouse by using a Portable NIR System and a FT NIR Spectrometer (Photo Diode Array형의 휴대용 근적외 분광기와 FT 근적외 분광기를 이용한 Hairless Mouse 피부 수분 정량)

  • Suh, Eun-Jung;Woo, Young-Ah;Kim, Hyo-Jin
    • YAKHAK HOEJI
    • /
    • v.49 no.2
    • /
    • pp.115-121
    • /
    • 2005
  • In this study, the performance of a portable NIR system and a FT NIR spectrometer were compared to determine water content of hairless mouse skin. The stratum corneum parts wer e separated from the epidermal tissues by trypsin solution. NIR diffuse reflectance spectra of hairless mouse skin were acquired using a fiber optic probe. In the near infrared, water molecules show two clear absorption bands at 1450 nm from first overtone of O-H stretching and 1940 nm from the combination involving O-H stretching and O-H deformation. It was found that the variations of O-H absorption band according to water content. Partial least squares regression (PLSR) was applied to develop a calibration model. The PLS model showed a good correlation between NIR predicted value and the absolute water content of separated hairless mouse skin, in vitro. For both the portable and the FT NIR spectrometer, These studies showed the possibility of a rapid and nondestructive skin moisture measurement using NIR spectroscopy. The portable NIR spectrometer with a photodiode arrays-microsensor could be more rapidly applied for the determination of water content with comparable accuracy with the performance of a FT spectrometer .

Blood Flow and Skin Temperature Increases by Monochromatic Infrared Energy Irradiation

  • Lee, Jae-Hyoung;Kim, Gi Won
    • The Journal of Korean Physical Therapy
    • /
    • v.24 no.3
    • /
    • pp.202-207
    • /
    • 2012
  • Purpose: The purpose of this study was to determine the effect of monochromatic infrared energy (MIRE) on the blood flow of the superficial radial artery and local skin temperature in healthy subjects. Methods: Forty healthy volunteers were recruited and randomly assigned to MIRE group (n=20) and placebo group (n=20). The MIRE group received a 890 nm MIRE irradiation on the forearm using two therapy pads for 30 minutes. The therapy pad was composed of an array of 60 diodes. MIRE unit was set at bar 8, that corresponds to a diode power of 10 mW and a power density of $63mW/cm^2$. The placebo group received sham MIRE. Peak blood flow velocity (PBFV), mean blood flow velocity (MBFV), and skin temperature (ST) were measured pre- and post-MIRE irradiation. Results: There was a significant difference in PBFV (p<0.001), MBFV (p<0.001), and ST (p<0.001) between the pre- and post-treated values in the MIRE group. In contrast, no significant difference was found between the pre- and post-treated values in the placebo group. There was significant difference in mean change values from baseline of PBFV (p<0.001), MBFV (p<0.001), and ST (p<0.001) between the MIRE group and the placebo group. There was a significant increase in PBFV (p<0.001), MBFV (p<0.001), and ST (p<0.001) following MIRE irradiation. Conclusion: The arterial blood flow and local skin temperature of the forearm in the healthy subjects were significantly increased following MIRE irradiation.

Measurement of Stride Length Using Optical Method (광학적 분석방법을 이용한 보폭측정)

  • Jung, Gu-In;Jun, Jae-Hoon;Lee, Kang-Hwi;Song, Min-Sun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.6
    • /
    • pp.1116-1122
    • /
    • 2008
  • Since conventional methods for measuring stride length(distance) are many weaknesses, optical methods have been developed to measure stride length(distance) of human pedestrians. IR(Infrared) elements and Power LED(Light Emitting Diode) with two types of lens were used to correlate detected light intensity with stride length(distance). The suggested methods in this study are simple, convenient, and cost effective. The results can be used to analyze walking patterns of normal and disabled men, and to monitor the recovering processes of the disabled patients.